• Title/Summary/Keyword: Opening Strength

검색결과 385건 처리시간 0.041초

스트럿-타이 모델에 의한 개구부를 갖는 깊은 보의 극한강도 예측 (Prediction of Ultimate Strength of Concrete Deep Beams with an Opening Using Strut-and-Tie Model)

  • 지호석;송하원;변근주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.189-194
    • /
    • 2001
  • In this study, ultimate strength of concrete deep beams with an opening is predicted by using Strut-and-Tie Model with a new effective compressive strength. First crack occurs around an opening by stress concentration due to geometric discontinuity. This results in decreasing ultimate strength of deep beams with an opening compared with general deep beams. With fundamental notion that ultimate strength of deep beam with an opening decreases as a result of reduction in effective compressive strength of a concrete strut, an equivalent effective compressive strength formula is proposed in order to reflect ultimate strength reduction due to an opening located in a concrete strut. An equivalent effective compressive strength formula which can reflect opening size and position is added to a testified algorithm of predicting ultimate strength of concrete deep beams. Therefore, ultimate strength of concrete deep beam with an opening is predicted by using a simple and rational STM algorithm including an equivalent effective compressive strength formula, not by finite element analysis or a former complex Strut-and-Tie Model

  • PDF

Ultimate strength of simply supported plate with opening under uniaxial compression

  • Yu, Chang-Li;Lee, Joo-Sung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제4권4호
    • /
    • pp.423-436
    • /
    • 2012
  • Unstiffened plates are integral part of all kinds of structures such as ship and offshore oil platforms. Openings are unavoidable and absolutely reduce the ultimate strength of structures. In this study, the finite element analysis package, ABAQUS, is used to analyze the behavior of unstiffened plate with rectangular opening. The rectangular opening form is divided into two cases. In case1, opening depth is constant, but opening width is varied. Meanwhile, in case2 opening width is fixed and opening depth is varied. Besides, for the two different form opening, the effect of plate slenderness parameter (${\beta}$), opening area ratio (AR) and opening position ratio (PR) on the ultimate strength of plate with opening under axial compression are presented. It has been found that the ultimate strength of plate ofcase1is much more sensitive to the plate slenderness parameter (${\beta}$) and opening area ratio (AR) than that of case2. However, for case1, opening position (PR) almost has no effect on the ultimate strength, whereas, regardingcase2, the influence of opening position (PR) depends on the plate slenderness parameter (${\beta}$). Based on nonlinear regression analysis, three design formulae are not only developed but also approved reasonably for the practical engineering design.

Ultimate Strength of 10 MW Wind Turbine Tower Considering Opening, Stiffener, and Initial Imperfection

  • Santos, Ralph Raymond;Cho, Sung-Jun;Park, Jong-Sup
    • 국제강구조저널
    • /
    • 제18권4호
    • /
    • pp.1318-1324
    • /
    • 2018
  • This paper evaluates the effects of door opening, collar stiffener, and initial imperfection on the ultimate strength of a 10 MW wind tower. The lower segment of the tower was modeled to investigate the ultimate strength using steel cylindrical shell elements of finite element program ABAQUS. The wind tower was classified into three categories; without opening nor stiffener (C1), with opening but no stiffener (C2), and with opening and stiffener (C3). The C2 and C3 were further divided into long axis and short axis categories depending on the position of the opening. Result from linear and nonlinear analyses shows that the bigger the opening the bigger the reduction in strength and the same thing goes for the initial imperfection ratio or ovality of the shell. Also, there is a significant decreased in strength as the initial imperfection ratio increases by as high as 18.08%.

다공 H 형강보의 보강효과에 관한 실험적 연구 (An Experimental Study on Reinforcing Effectiveness of H-Shaped Steel Beams with Rectangular Web Openings)

  • 김진무
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권3호
    • /
    • pp.213-222
    • /
    • 1999
  • On condition that opening located at high shear strength position in H-shaped steel beams with web opening, beams are structurally to be frailed so necessity and efficiency of vertical reinforcement to add horizontal reinforcement already published ahead study. Up to the present study of web opening beams, limited one opening which located in comparatively small shear strength position. But frequently opening area is enlargement by necessity, so width of opening is larger by limit of depth or increasing number of opening. This study carry out experiment to make efficient reinforcing method about strength and deformation of steel beams with web openings. Parameters of this study are openings location, ratio of opening width within opening height and various reinforcing types.

  • PDF

Ultimate uniaxial compressive strength of stiffened panel with opening under lateral pressure

  • Yu, Chang-Li;Feng, Ji-Cai;Chen, Ke
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제7권2호
    • /
    • pp.399-408
    • /
    • 2015
  • This paper concentrated on the ultimate uniaxial compressive strength of stiffened panel with opening under lateral load and also studied the design-oriented formulae. For this purpose, three series of well executed experiments on longitudinal stiffened panel with rectangular opening subjected to the combined load have been selected as test models. The finite element analysis package, ABAQUS, is used for simulation with considering the large elasticplastic deflection behavior of stiffened panels. The feasibility of the numerical procedure is verified by a good agreement of experimental results and numerical results. More cases studies are executed employing nonlinear finite element method to analyze the influence of design variables on the ultimate strength of stiffened panel with opening under combined pressure. Based on data, two design formulae corresponding to different opening types are fitted, and accuracy of them is illustrated to demonstrate that they could be applied to basic design of practical engineering structure.

유공 합성보의 극한강도식의 제안 (Ultimate Strength of Composite Beams with Unreinforced Web Opening)

  • 김창호;박종원;김희구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.369-374
    • /
    • 1999
  • A practical approach of calculating the ultimate strength of composite beams with unreinforced web opening is proposed. In this method, the slab shear contribution at the opening is calculated as the smaller of the shear strength of the slab and the pullout capacity of the shear connectors at the high moment end. A simple interaction equation is used to predict the ultimate strength under simultaneous bending moment and shear force. Strength prediction by the proposed method is compared with previous test results and the predictions by other analytical method. The comparison shows that the proposed method predicts the ultimate capacity with resonable accuracy.

  • PDF

고강도 철근콘크리트 유공보의 역학적 거동에 관한 실험적 연구 (An Experimental Study on Mechanical Behavior of High Strength Concrete Beam with Circular Opening)

  • 구범모;박강근;윤승현;김용태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.609-614
    • /
    • 2000
  • This paper is an experimental study of the normal strength concrete beam and high strength concrete beam for the analysis of bending and shear behavior. In building structure, the story height can be minimized by providing openings in beams which serves for the utility equipments passing through. The dead space in false ceiling increase construction cost, the good ceiling system such as beam with opening give to economical merits because of a substantial reduction in materials and construction cost. For the analysis on the mechanical behavior of the reinforced high strength and normal strength concrete beams with circular opening in the web, the stress concentration of the circular opening, crack pattern and reinforcing methods were studied. Twenty test pieces with different reinforcing methods and difference concrete strength were tested and their resisting forces and load deflection curves were defined in this study.

  • PDF

교통개방을 위한 에폭시 아스팔트 콘크리트의 강도 예측모델 개발 (A Development of Strength Prediction Model of Epoxy Asphalt Concrete for Traffic Opening)

  • 백유진;조신행;박창우;김낙석
    • 대한토목학회논문집
    • /
    • 제32권6D호
    • /
    • pp.599-605
    • /
    • 2012
  • 교통개방시점의 예측은 공사 계획을 위해 중요하며 이를 위해 에폭시 아스팔트 혼합물의 양생에 따른 강도를 예측하는 것이 필요하다. 본 연구에서는 에폭시 아스팔트 혼합물의 양생온도와 시간에 따른 마샬안정도를 측정하고 이를 이용해 강도 발현식을 구하였으며, 변화하는 온도와 강도에 따른 반응속도를 반영할 수 있도록 화학적 반응속도론을 이용하여 에폭시 아스팔트 강도 예측모델을 개발하였다. 예측모델을 사용하여 에폭시 아스팔트 포장이 적용된 국내 교량에 대해 교통개방시기를 예측하였다. 2009년~2011년의 기상조건에 따라 가정된 포장체 온도를 사용한 예측결과는 실제 교통개방일과 17일의 차이가 발생했으나 이는 2012년의 실제 기상상태와의 차이 때문이다. 실제 측정된 포장 온도를 예측모델에 대입할 경우 2일의 교통개방가능일 차이가 있었으며, 상관관계 분석 결과 R2가 0.95로 실제 강도값과 매우 유사한 결과를 얻을 수 있었다. 기상상태와 포장체의 온도에 대한 충분한 데이터를 확보한다면 에폭시 아스팔트 강도 예측모델을 사용하여 상당히 신뢰도 있는 교통개방 가능 시기의 예측이 가능한 것으로 나타났다.

유공판의 좌굴강도에 관한 연구 (A Study on the Buckling Strength of Plate Panels with Opening)

  • 김을년;최익흥;권진칠;백점기
    • 대한조선학회논문집
    • /
    • 제47권2호
    • /
    • pp.210-224
    • /
    • 2010
  • The aim of the present study is to investigate the buckling strength of plates and stiffened panels with opening under transverse thrust and shear actions. It is observed that the existing design formulation for critical-buckling strength of plates are not valid for perforated plates, because the current design formulation trends can significantly overestimate or underestimate the load-carrying capacity of plates when plates have large opening and/or are thick. A series of eigen value and elastic.plastic large deflection finite element analyses are carried out with varying the aspect ratio of plate, the opening size and location on plate until and after the ultimate strength is reached. Based on the results obtained from the present study, closed-form design formulations for the elastic buckling strength of plates and stiffened panels with opening are derived. The derived design formulations are considered plasticity correction of the material and verified by experimental tests and results of nonlinear finite element computations.

An investigation into the shear strength of SFRC beams with opening in web using NFEM

  • Karimi, Mohammad;Hashemia, Seyed Hamid
    • Computers and Concrete
    • /
    • 제21권5호
    • /
    • pp.539-546
    • /
    • 2018
  • Making a transverse opening in concrete beams in order to accommodate utility services through the member instead of below or above of that, sometimes may be necessary. It is obvious that inclusions of an opening in a beam decreases its flexural and shear strengths. Fabricated steel bars are usually used to increase the capacity of the opening section, but details of reinforcements around the opening are dense and complex resulting in laborious pouring and setup process. The goal of this study was to investigate the possibility of using steel fibers in concrete mixture instead of complex reinforcement detailing order to strengthen opening section. Nonlinear finite element method was employed to investigate the behavior of steel fiber reinforced concrete beams. The numerical models were validated by comparison with experimental measurements tested by other investigators and then used to study the influence of fiber length, fiber aspect ratio and fiber content on the shear performance of SFRC slender beams with opening. Finally, it was concluded that the predicted shear strength enhancement is considerably influenced by use of steel fibers in concrete mixture but the effect of fiber length and fiber aspect ratio wasn't significant.