Properties of the Load-Sensing Hydraulic System from a Viewpoint of Control (제어관점에서의 부하감지형 유압시스템의 특성)

  • 김성동
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.3
    • /
    • pp.738-750
    • /
    • 1994
  • The load-sensing hydraulic system which was developed to improve energy efficiency of conventional hydraulic systems has its own properties. The instability of system responses, linearity of a servo valve, robustness for variation of external load, and dynamic interference between hydraulic motors are such properties which have much to do with control properties of the system. The load-sensing hydraulic system has instability tendancy because the load-sensing mechanism makes a positive feedback loop between the motor part and the pump part. A flow property of the servo valve can be said to be linear because the flow through the valve has nothing to do with a load pressure and the flow is strictly proportional to a valve opening which is adjusted by a valve command signal. The resultant control property can be said to be robust because the steady-state control performance is independent to the load actuated on the motor shaft. In the case when one pump simultaneously drives more than two hydraulic motors, the pump outlet pressure is determined by a hydraulic motor of the largest load pressure among all of the hydraulic motors, and, thus, the other motors are dominated by the largest load pressure. That is, the other motors can be said to be interfered by the motor of the largest load pressure.

Examination of Cavitation-Induced Surface Erosion Pitting of a Mechanical Heart Valve Using a Solenoid-Actuated Apparatus

  • Lee, Hwan-Sung;Hwang, Sung-Won;Katsuyuki Yamamoto
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.9
    • /
    • pp.1339-1348
    • /
    • 2003
  • Several factors, including peak dp/dt of the ventricular pressure and maximum closing velocity of leaflet have been studied as indices of the cavitation threshold. In the present study, just before closing velocity of the leaflet has been studied as indices of the cavitation threshold, and cavitation erosion on the surface of a mechanical valve was examined by focusing on squeeze flow and the water hammer phenomenon during the closing period of the valve. A simple solenoid-actuated test device that can directly control the valve closing velocity was developed, and opening-closing tests of 3,000 and 40,000 cycles were performed at various closing velocities. There was a closing velocity threshold to occur erosion pitting of valve surface, and its value was about 0.4 m/s in this study. Cavitation-induced erosion pits were observed only in regions where squeeze flow occurred immediately before valve closure On the other hand, the number of the pits was found to be closely related to an area of water hammer-induced pressure wave below the critical pressure defined by water vapor pressure. Therefore, it was concluded that cavitation is initiated and augmented by the two pressure drops due to squeeze flow and water hammer phenomenon, respectively.

Experimental study on compression wave propagating in a sudden reduction duct (급축소관을 전파하는 압축파에 관한 실험적 연구)

  • Kim, Hui-Dong;Matsuo, Kazuyasu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.9
    • /
    • pp.1139-1148
    • /
    • 1997
  • Compression waves propagating in a high-speed railway tunnel develops large pressure fluctuations on the train body or tunnel structures. The pressure fluctuations would cause an ear discomfort for the passengers and increase the aerodynamic resistance of trains. As a fundamental research to resolve the pressure wave phenomenon in the tunnel, experiments were carried out by using a shock tube with an open end. A blockage to model trains inside the tunnel was installed on the lower wall of shock tube, thus forming a sudden cross-sectional area reduction. The compression waves were obtained by the fast opening gate valve instead of a conventional diaphragm of shock tube and measured by the flush mounted pressure transducers with a high sensitivity. The experimental results were compared with the previous theoretical analyses. The results show that the ratio of the reflected to the incident compression wave at the sudden cross-sectional area reduction increases but the ratio of the passing to the incident compression wave decreases, as the incident compression wave becomes stronger. This experimental results are in good agreements with the previous theoretical ones. The maximum pressure gradient of the compression wave abruptly increases but the width of the wave front does not vary, as it passes over the sudden cross-sectional area reduction.

Comparison of Wind Pressure Coefficient and Wind Load Standard for Cladding in a Retractable Dome Roof by Wind Tunnel Test (풍동 실험을 통한 개폐식 돔 지붕의 외장재용 풍압 계수와 풍하중 기준 비교)

  • Cheon, Dong-jin;Kim, Yong-Chul;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.3
    • /
    • pp.125-132
    • /
    • 2018
  • The biggest impact on the cladding design of buildings is wind loads. Wind tunnel tests were conducted to examine the applicability of current wind load standards about membrane retractable roof spatial structure. A dome model with a circular shape that is retractable to the center of the dome was made (Opening ratio = 0, 10, 30, 50). In addition, height adjustable turntables were made and tested with five patterns with H/D = 0.1, 0.2, 0.3, 0.4 and 0.5. The maximum wind pressure coefficient and the minimum wind pressure coefficient for the cladding were analyzed and the experimental wind pressure coefficient were compared with the current wind load standards, KBC2016 and AIJ-RLB(2015). The experimental value and the reference value of the enclosed roof were very similar and showed possibility of application, but opened roof case was found that the reference value was underestimated.

Aging Characteristics of Low Pressure LPG Regulators for Domestic Use (가정용 LPG 저압조정기의 경년특성에 관한 연구)

  • Kim Young-Gyu;Kwon Jeong-Rock
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.1
    • /
    • pp.58-63
    • /
    • 1999
  • Experimental works were carried out to evaluate how the lapse of time affects the performance characteristics and the service life of low pressure LPG regulators for domestic use. Experimental results showed that the operating pressure of safety devices deviated from the opening pressure value and the closing pressure value from just 1 year after service, and the operating pressure of regulators used for 7${\~}$8 years notably deviated from the reference value of the adjusting pressure and the closing pressure. And the material properties of springs and diaphragms deteriorated after 5${\~}$6 years of service. Thus, it is estimated that low pressure LPG regulators have approximately 6 years of service life. However, it is highly recommended that regulators exceeding 5 years of service should be replaced for the safety of consumer and accident prevention even if they are operating normally.

  • PDF

Sluice Gates Control Monitoring of Oil Pressure-Machine Using FDC Tuning Control Technique (FDC 동조제어기법을 이용한 유압-기계식 수문 제어 모니터링)

  • Heo, Gwanghee;Kim, Chunggil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.4A
    • /
    • pp.337-342
    • /
    • 2010
  • Generally most sluice gates are closed and opened by a mechanical winch, a winch using an oil-pressure, or a winch mixing both. Because of their size and structure, they should be safely operated with more than two pulling devices helping each other. At the moment of their opening and closing, there usually occur some additional loads to the structure which cannot be exactly measurable at the stage of designing. Such additional loads can cause the sluice gate to be unbalanced and make it hard to open and close the gate, and by also overloading a winch, they can inflict a significant damage to the safety of the sluice gate. This paper explains a FDC(Force-Displacement Control) system which simultaneously considered the oil-pressure and displacement in order to evenly distribute the force and make a winch balanced at the opening and closing motion. This FDC system was implemented by means of the PID(Proportional Integral Derivative) function of XG 5000 program. It was experimented on a model of the sluice gate winch with the hydraulic oil pressure cylinder. The experiments showed that the developed FDC system made the winch of hydraulic oil pressure cylinder open and close cooperatively in spite of various external loads. Therefore the FDC system is proven effective when it is applied to a winch of sluice gate.

Verifying the Suitability or Unsuitability of the Opening Force Criteria Applied to Air Pressurized Access Door to a Smoke Control Zone (급기 가압 제연구역 출입문에 적용되는 개방력 기준의 적합성 여부에 관한 연구)

  • Lee, Jae-Ou;Choi, Chung-Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5820-5825
    • /
    • 2014
  • The aim of this study was to verify the suitability or unsuitability of Korean body types by measuring the opening force criteria of an air pressurized access door to a smoke control zone. The opening force criteria were verified by comparing the NFSC 501A, NFPA 92A and BS-EN 12101-6 based on the body standards information from the Korean Agency for Technology and Standards. When measuring the opening forces, the posture of the body should be standing upright and pushing an access door with the right hand, which is a criterion for designing doors. As a result of analyzing the actual measurement results, the pushing force of men and women in their 30's was the maximum value and the forces in those in their 60's was the minimum value. In addition, the deviations in the pushing forces varied considerably. As a result of comparing the NFSC 501A, the men showed lower values than the criteria in every gender and age variable except for the 20's, 30's and 50's variable. A comparison of the criteria of NFPA 92A showed that the mean of the measured values from every gender and age was also lower than the criteria. In addition, when comparing the criteria of BS-EN 12101-6, it was found that the men in every age variable were higher than the criteria. On the other hand, the women in every age variable were lower than the criteria. Therefore, considering the Korean body type against the Western body type, it was decided that the opening force of an access door to a smoke control area to make a downward adjustment should be 110 N in the local criteria. Furthermore, the criteria should consider the characteristics of buildings and users because an optional application of the international standard is not necessarily suitable for local situations.

Solving the Problems Caused by Stack Effect in a High-rise Residential Building through Field Measurement and Simulation; Case Study (실측과 시뮬레이션을 통한 초고층 주거건물에서의 연돌효과 문제의 해결)

  • Koo Sung-Han;Jo Jae-Hun;Yeo Myoung-Souk;Kim Kwang-Woo
    • Journal of the Korean housing association
    • /
    • v.16 no.4
    • /
    • pp.73-80
    • /
    • 2005
  • A high-rise residential building experienced stack effect problems during the winter such as difficulties in opening residential entrance doors and whistling noise from elevator doors generated by airflow. Field measurements were carried out on the building and the problems were verified by the analysis of the measurement results from three points of view: the total stack pressure difference, pressure distribution on each floor, and the location of the neutral pressure level. Based on the analysis of the three key parameters, possible solutions were proposed, such as zoning vertical shafts, lessening the airflow from the entrance doors on basement floors and lobby floor by installing vestibules, improving the airtightness of exterior walls, and installing separation doors where the problems occur. Simulations of proposed solutions were conducted and the effects of reducing the pressure difference were evaluated. Stack effect problems in a high-rise residential building were verified through field measurements and could be mitigated by the solutions which were drawn from the analysis of the field measurements and the simulation results.

Balancing air flow at terminal in CAV duct system with DPM method (정풍량방식 덕트에서 이중압력측정방법을 이용한 취출구 풍량조정)

  • 이대우;박명식;박영우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.1
    • /
    • pp.66-78
    • /
    • 1998
  • Adequate ventilation with the proper amount of air to the right place is important factor to achieve a good Indoor air climate. Thus it is of prime importance that the ventilation system is working properly. This requires reliable pressure loss calculation to balance the air flow through duct systems. So a computer program for balancing CAV duct system is developed In this study. The results of CAV duct system is compared with the "Balans" code developed by Larsen from Norway. To obtain the pressure drop characteristics of damper at duct terminal, some experiments are performed using DPM(Dual Pressure Measurement) system. To adjust the resistance of damper, present study suggests that some special diffusers should be designed and damper producers should give the data of air flow vs. pressure drop to the customs when they manufacture the damper. One of the results concludes that the working time can be reduced from several minutes to several seconds per damper in the present experimental site, if the DPM system and the air volume adjusting process are used.

  • PDF

Behaviour of Nak-dong River Sand on Cyclic Stress History (낙동강 모래의 반복응력이력에 의한 거동)

  • 김영수;박명렬;김병탁;이상복
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.295-302
    • /
    • 2000
  • Earthquakes not only produce additional load on the structures and underlying soil, but also change the strength characteristics of the soil. Therefore, in order to analyze soil structures for stability, the behaviour after earthquake must be considered. In this paper, a series of cyclic triaxial tests and monotonic triaxial tests were carried out to investigate the undrained shear strength and liquefaction strength characteristics of Nak-Dong River sand soils which were subjected to cyclic loading. The sample was consolidated in the first stage and then subjected to stress controlled cyclic loading with 0.1Hz. After the cyclic loading, the cyclic-induced excess pore water pressure was dissipated by opening the drainage valve and the sample was reconsolidated to the initial effective mean principal stress(p/sub c/'). After reconsolidation, the monotonic loading or cyclic loading were applied to the specimen. In the results, the undrained shear strength and liquefaction strength characteristics depended on the pore pressure ratio(Ur=U/p/sub c/'). The volume change following reconsolidation can be a function of cyclic-induced excess pore water pressure and the maximum double amplitude of axial strain.

  • PDF