• 제목/요약/키워드: Opening/closing time

검색결과 139건 처리시간 0.025초

출입문용 자동개폐장치를 설치한 실내체육관의 피난안전성 분석 (Analysis of the Evacuation Safety of Indoor Stadiums with Automatic Opening/Closing Exit Installations)

  • 안재천;공하성
    • 대한안전경영과학회지
    • /
    • 제22권3호
    • /
    • pp.15-21
    • /
    • 2020
  • This study analyzed the evacuation time in indoor stadiums when exits that automatically open/close when the fire sensor is triggered are installed as a means to improve the problem of closing certain exits. Firstly, when spectators on the 2nd floor stands exit through the 1st floor exits, the RSET of all inhabitants was 529.8 seconds when the automatic opening/closing exits are broken and employees are not present. Secondly, when spectators on the 2nd floor stands exit through the 1st floor exits, the RSET of all inhabitants was 445 seconds when the automatic opening/closing exits with 750mm width are working but employees are not present. Lastly, when spectators on the 2nd floor stands exit through the 1st floor exits, the RSET of all spectators was 337 seconds when the automatic opening/closing exits with 1,500mm width are working and employees are present. As a result, it was revealed that the evacuation time is shortened when the automatic opening/closing exits are working. Additional comparative studies with actual simulations of people evacuating an indoor stadium and firefighting simulations considering smoke flow are necessary.

중등학교 교실의 이산화탄소(CO2) 관리를 위한 지능형 창호개폐 작동 프로세스 (Intelligent and Responsive Window Opening-Closing Operation Process for Carbon Dioxide(CO2) Management of Secondary School Classroom)

  • 최윤영;이현수
    • 교육시설 논문지
    • /
    • 제25권4호
    • /
    • pp.19-30
    • /
    • 2018
  • The school classroom is a common living place where students spend 7 to 14 hours a day to prepare for their careers. Therefore, if the ventilation of the classroom is not properly performed, it may lead to the deterioration of learning ability due to the unclear air. The concentration of carbon dioxide in the classroom is reported to be high, and the increase in carbon dioxide concentration has a negative effect on the learner's academic performance. In this context, the purpose of this study is to propose a methodology for intelligent and responsive window opening-closing operation process that can reduce the concentration of $CO_2$ in the classroom in order to build a support space that can create an effective teaching-learning environment for adolescents. The specific objectives are as follows. First of all, we define the concept of window opening-closing operation. Secondly, twe develop the operation process of window opening-closing. Thirdly, we develop an algorithm for real-time window opening and closing (process) (Window Opening-Closing Operation Process). Finally, we verify the intelligent responsive window opening-closing operation process through developing examples of window opening-closing operation process using the parametric design program. This study is a preliminary study to develop algorithms necessary for window opening-closing operation. Based on the first-order algorithm, We simulated window opening-closing operations according to a hypothetical scenario. As a result, This study can show that the window is open and close depending on the $CO_2$ concentration, but the $CO_2$ concentration in the room is higher than outdoors. Consequentially, we suggest that it is necessary to develop an algorithm to supplement these results because window is often not working when the temperature difference between indoor and outdoor in winter is large.

Transient simulation and experiment validation on the opening and closing process of a ball valve

  • Han, Yong;Zhou, Ling;Bai, Ling;Xue, Peng;Lv, Wanning;Shi, Weidong;Huang, Gaoyang
    • Nuclear Engineering and Technology
    • /
    • 제54권5호
    • /
    • pp.1674-1685
    • /
    • 2022
  • The ball valve is an important device in the pipeline transportation system of nuclear power plants. Its operational stability and safety directly affect the normal working of nuclear power plants. In this study, the transient numerical simulation of the opening and closing process of a ball valve was conducted on the basis of the flow interruption capability experiment of the ball valve by using the moving mesh method and inlet and outlet variable boundary conditions. The flow rate and pressure difference with time of the opening and closing process of the ball valve were studied. The internal flow characteristics of the ball valve under different relative openings were analyzed in conjunction with the typical back-step flow structure. Results show that the transient numerical results agree well with the experimental results. The internal flow characteristics of the ball valve are similar at the same opening during opening and closing process. At small opening, the spool and outlet channels easily form a back-step flow structure. The disappearance and generation of backflow vortices during opening and closing occur at 85% opening and 75% opening, respectively. With the decrease in opening degree, the difference in vortex core area in the flow channel of the ball valve spool in the opening and closing process gradually appears. The research results provide some reference value for the design and optimization of ball valves.

수동운전방식에서의 PSD 출입문 신호반응 시간 개선 방안 연구 (PSD Door Response Time Improving Method in Train Manual Operation Mode)

  • 이무호;김찬겸;이석종;이수영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.559-571
    • /
    • 2008
  • Platform Screen Door(PSD) has been installed and operated at seoul subway line $1\sim4$ in the manual train operation mode(ATS/ATC) by SeoulMetro since 2005. SeoulMetro uses the wireless (RF) communication system and the train door detection system for the link between the train and PSD doors opening/closing motion in the manual train operation mode. For the convenience and safety of passengers, the train doors and the PSD doors opening/closing shall be synchronized as much as possible. In ATO(Automatic Train Operation) mode which provides the interface between train control system and PSD system, ATO signaling system makes the train doors and PSD doors open/close command signals systematically, so PSD doors can be opened/closed almost simultaneously with the train doors. But, in the manual train control(ATS/ATC) mode, PSD system needs to detect the train doors open/close operation and make PSD open/close command signals to actuate PSD doors. These PSD open/close commanding process cause time delay of PSD doors opening/closing motion in response to the train doors opening/closing motion. Sometimes the response delay time can be over 1 second, which is not proper to operate PSD, and need to be reduced This paper presents the reduction method of the PSD response delay time to improve the convenience and safety of passengers.

  • PDF

부속실 출입문 크기 변화를 고려한 개방 및 폐쇄조건 분석 (An Analysis of the Opening and Closing Condition with Various Fire Door Size in the Pressurized Room)

  • 유우준;남준석;유홍선
    • 한국화재소방학회논문지
    • /
    • 제25권2호
    • /
    • pp.132-137
    • /
    • 2011
  • 부속실 단독가압의 제연설비 구역에서 계단실 출입문의 크기 변화가 개방 및 폐쇄조건에 미치는 영향을 분석하기 위해서 자동폐쇄장치의 구조와 저항모멘트의 관계를 정리하였으며, 부속실 출입문의 크기 변화를 고려하여 개방력과 폐쇄력을 측정하였다. 그 결과 부속실 출입문의 크기가 증가할수록 개방 및 폐쇄조건에 도달하기 위한 힘의 크기는 증가하였으며, 폐쇄시간, 회전속도, 회전각도와 힘의 관계, 자동폐쇄장치의 효율을 고려한 부속실 출입문의 설계범위가 존재함을 확인하였다.

Zigbee와 적외선 센서를 활용한 밸브 개폐 모니터링 시스템 설계 및 구현 (Valve monitoring system design and implementation using an infrared sensor and ZigBee)

  • 심현;오재철
    • 한국전자통신학회논문지
    • /
    • 제10권1호
    • /
    • pp.73-80
    • /
    • 2015
  • 화학공장과 같이 위험지역에 설치된 밸브장치는 폭발의 위험을 방지하기 위해 방화 방폭장치로 밀폐되어 있다. 본 논문에서는 방폭장치로 인해 외부전원장치를 사용할 수 없는 밸브장치에 적외선센서와 Zigbee 센서를 이용하여 위험지역의 밸브의 열림도를 측정하여 개폐여부를 확인하고, 밸브 개폐 작동시간을 로그화하여 운전 관리자가 공장을 관리 통제할 수 있는 저전력 모니터링 시스템을 제안한다. 전력관리기능을 적용하기 위해 개선된 비동기LPL 알고리즘을 적용한 전력제어 릴레이보드를 개발하고, 이를 적용한 방폭형 지능형 밸브시스템과 공장 밸브 개폐모니터링 시스템을 설계하고 이를 구현 및 테스트 하였다.

수문개폐에 따른 낙동강 하구둑 하류부의 해양물리환경변화 (Variations of Physical Oceanographic Environment Caused by Opening and Closing the Floodgate in Nakdong Estuary)

  • 김기철;양한섭;김차겸;문창호;장성태
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제2권2호
    • /
    • pp.49-59
    • /
    • 1999
  • 낙동강 하구역은 담수와 해수가 만나 복잡한 순환양상을 보이는 지역이다 낙동강 하구역은 하구둑의 건설로 혼합체계와 순환양상이 많이 변하였다. 논 연구에서는 낙동강 하구둑 하류부의 해양 물리 환경 변화론 하구둑의 수문개폐에 초점을 맞춰 분석하였다. 관측과 분석에는 3가지의 경우로 나누었다. 1. 평상시 (조시에 따라 수문 개폐) 2. 홍수시 (수문 완전 개방) 3. 갈수시(수문이 완전히 닫혔을시).

  • PDF

유무선 카운팅 연동형 AI 영상분석 비상문 개폐 시스템 개발 (Development of AI Image Analysis Emergency Door Opening and Closing System linked Wired/Wireless Counting)

  • 강철수;홍지연;김봉현
    • 디지털정책학회지
    • /
    • 제1권2호
    • /
    • pp.1-8
    • /
    • 2022
  • 위험상황 발생 시 비상구 역할을 하는 옥상은 소방법상 화재를 대비하여 개방되어 있어야 한다. 그러나, 옥상 문 개방 시 불법적인 출입, 범죄, 투신 등 각종 사건, 사고 발생의 장소가 되고 있다. 그러다보니, 범죄 및 각종 사건, 사고의 방지를 위하여 시설관리 측면에서 옥상 출입문을 폐쇄하는 것이 현실이다. 이에, 정부에서는 옥상 출입문에 전자식 자동개폐장치 설치를 의무화하는 내용의 주택건설기준 등에 관한 규정 입법을 추진하고 있다. 따라서, 본 논문에서는 지능형 비상문 개폐장치 시스템을 제안하였다. 이를 위해, 유무선 출입 카운팅 및 AI 영상분석을 연동하여 지능형 비상문 개폐 시스템을 개발하였다. 최종적으로, 장치상태 실시간 모니터링 이벤트 알람 중앙 집적 방식의 원격제어 및 이력관리 기능이 제공되는 무선통신 기반 통합 관리 플랫폼 구축이 가능하다.

방화문의 내화성능 향상을 위한 3단 문 결속기 연구개발 (Research and development of a three-stage door binder to improve the fire resistance of fire doors)

  • 임보혁;이주원;조동환;이해열
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.157-158
    • /
    • 2023
  • Doors that are opened and closed when entering or exiting a general building are connected to the door frame and open and close. They are equipped with door locking devices of various structures, and are either locked to the door frame for the closing operation or released from the door frame for the opening and closing operation. Here, a single-stage door binding device having a door latch that is independently disposed at the center of one axis of the door is commonly used. On the other hand, if the size of the door is over a certain size or if the door is medium to large, the opening and closing operation may not be performed smoothly with only a single stage binder, or the closing state may not be achieved stably during the closing operation. In particular, in the case of the single-stage binding device provided in medium to large fire doors, the door is fixed to the door frame unstable, causing fatal errors in the fire prevention function of the fire door. Accordingly, in order to fundamentally solve these problems, we researched and developed a three-stage door binding machine that combines a top and bottom fastening structure with a single-stage fastening structure. This 3-stage door binder not only has the fire resistance performance of a fire door, but also has a T-shaped terminal in its fastening method, so if you eliminate the upper and lower fastening, it is a 1-stage binder like a regular product, but if you remove the door latch of the 1st-stage binder, it functions as an upper and lower 2-stage binder and forms a single mold. We researched and developed a three-stage door binder that can manufacture and produce three products at the same time, satisfying both product performance and price.

  • PDF

쉘타입 로울러 게이트의 회피개도량 산정 방법 (A Method on Estimation of Avoiding Open Range on Shell-type Roller Gate)

  • 정지승;정해욱
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.85-91
    • /
    • 2017
  • When the shell-type roller gate is partly open, at a certain height the large vibration is caused due to resonance and the vibration can cause damage to the gate. In this study, the review on amplitude of vibration and the possible resonance occurring at the time of opening or closing of gate is performed. Throughout the natural frequency analysis, the installation location of the measuring instrument was selected. On opening or closing of gate, the measurement of gate vibration is performed. The natural frequencies according to the opening range of the gate is analyzed. As a result of measurement and analysis, we proposed ranges in which vibration occurs largely and resonance is predicted as an avoiding open ranges, or the safe opening or closing of the shell-type roller gate. The application of this paper's avoiding open range estimation method of shell-type roller gate can be utilized as the basic data for the systematic and rational maintenance management of dams and submerged weirs in the future, and it is expected that this study can bring forth.