• Title/Summary/Keyword: Open-type ceiling

Search Result 9, Processing Time 0.019 seconds

Measurements of absorption coefficients of open-type ceilings using 1:25 scale model reverberation chamber (축척모형을 활용한 개방형 천장의 흡음률 측정)

  • Lee, Hye-Mi;Kim, Yong-Hee;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.683-686
    • /
    • 2007
  • This paper investigates acoustical characteristics of open-type ceilings using 1:25 scale model. The field survey in the existing 15 halls was carried out to figure out the ceiling structure. The components of the open-type ceiling were mainly steel truss structures, duct, catwalk and finishing surfaces. In order to investigate the absorption characteristics of the equipped ceiling, the absorption coefficient measurements were made using 1:25 reverberation chamber based on ISO 354. Results showed that the absorption coefficient of the empty ceiling structure (6m-height) with 50%-perforated covering plate was 0.2-0.3 at above 500 Hz. When steel structure was added inside the empty ceiling, absorption coefficient increased by 0.16 at 250-1kHz. Adding catwalk did not increase the absorption, but adding duct increased the absorption at 1-2kHz. NRC of the equipped ceiling was 0.39, and the absorption characteristics were mainly found at high frequencies. In addition, the opening size of the covering plate did not change the absorption coefficient of the equipped ceiling meaningfully.

  • PDF

Optimal Flow Control of Ceiling Type Indoor Unit by PIV Measurements (PIV 유동 계측을 통한 천장형 실내기의 최적 제어 설계)

  • Sung, Jae-Yong;An, Kwang-Hyup;Lee, Gi-Seop;Choi, Ho-Seon;Lee, In-Seop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1042-1050
    • /
    • 2003
  • A heating flow discharged from a 4-way ceiling type indoor unit has been investigated to determine the design parameters for the optimal flow control. The flow was measured by a PIV(particle image velocimetry) system and an experimental model of 1/10 scale with a transparent room was devised by satisfying the Archimedes number. This similarity is generally used in cases where the forced convection has similar magnitude of the natural convection. To optimize the heating flow, several vane angles and vane control algorithms of cross and right angle controls were considered. Regarding the vane angle, experimental results show that 30$^{\circ}$is an optimal angle to avoid re-suction flows without significant increase in flow noise. Temperature distribution measured in the environmental chamber ensures the increased thermal comfort when compared to the case, 60$^{\circ}$angle. At the optimal angle, applying open/close control gives rise to more uniform distribution of the heating flow than without control. Especially, the cross-control seems to be satisfactory for thermal comfort.

Design of Optimal Vane Control for Ceiling Type Indoor Unit by PIV measurements (천장형 실내기의 기류 가시화를 통한 최적 제어 설계)

  • Sung Jaeyong;An Kwang Hyup;Lee Gi Seop;Choi Ho Seon;Park Seung-Chul;Lee In-Seop
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.533-536
    • /
    • 2002
  • A heating flow discharged from a 4-way ceiling type indoor unit has been investigated using a PIV(particle image velocimetry) system For the PIV measurements, an experimental model of 1/10 scale with a transparent room was devised by satisfying the Archimedes number, which is generally used in case that the forced convection has the similar magnitude as the natural convection. To optimize the heating flow, several vane angles and vane control algorithms of cross and right angle controls were considered. Regarding the vane angle, the experimental results show that it should be less than $30^{\circ}$ to avoid re-suction flows which decrease the performance of the air-conditioner. At the vane angle of $30^{\circ}$, applying open/close control gives nae to more uniform distribution of the heating flow than without control. Especially, the cross-control seems to be satisfactory for the thermal comfort.

  • PDF

A Study on Applications of Housing Interior Design Elements according to the Sensibility Type (감성유형에 따른 주거 실내디자인요소 적용방안)

  • Park, Ji-Min;Park, En-Sun
    • Journal of the Korean housing association
    • /
    • v.25 no.3
    • /
    • pp.165-179
    • /
    • 2014
  • The purpose of this study was to draw application elements of housing interior design according to user-oriented sensibility types. The sensibility evaluation experiments were conducted to target the general user 118 people using the sensibility evaluation tool for housing interior space. The results of the analysis were as: To produce the 'cozy' space, the colors and materials giving soft and natural feeling should be used. For the 'practical' space, type of ceiling and window that give the visually open feeling, the user-oriented furniture arrangement that allows using the space efficiently. For the 'cheerful' space, the simple and natural effects should be produced by using closed space that stable. For the 'traditional' space, the natural fishing material having rough texture should be used. For the 'unique' space, the space contained the dynamic feeling by the diagonal or vertical line and the graphic expression in the wall. For the 'congenial' emotional space, basic is the symmetric, stable and simple space. On the other hand, for the material, small size, natural texture or typical and soft materials should be used. For the 'sensuous' space, the dynamic and vertical sense of space should be expressed by the type of ceiling. The most important elements for the space of 'gorgeous' sensibility, is the color.

A Study on Plan Structure Types and Characteristics of Wall Formation in Art Museum Exhibition Spaces

  • Lee, Jong-Sook
    • Architectural research
    • /
    • v.13 no.3
    • /
    • pp.3-10
    • /
    • 2011
  • The Characteristics of space are determined by several factors; however, the element that determines the physical characteristic of floors, walls, and ceiling is the structure. This study constructs a wall to analyze the direct effect that the layout of an exhibition wall has on the element of the wall followed by the structural process and visibility of descriptive analysis and examples of art museums that the shift from a perceptional wall to an experiential wall affected circulation. For elements and formation methods of the wall, first, it is made up of open and closed type exhibition spaces, and it can give abundance in qualitative space rather than a quantitative aspect. Secondly, the directivity of space changes according to the development of the visible axis, thus, directly affects the change in visibility. Thirdly, the difference between spatial structure and visual structure is the difference between the visual axis and spatial structure. The wall formation type followed by the combination method, the simple visible structure, which is the type that possesses the simple combination (Room, Zone, Cluster), repeatedly uses the same size of units of space that is orderly and has few spatial axes and the classification of simple type and simple cluster type, which has few visible axes, also exists. Also, with the complex structure of the maze type it displays the reiterated form of the cluster, which is the space with disorderly combination and has much visible axes and spatial axes. Also, these can be divided into three types: 1) Maze Cluster Type, 2) Cross Road Type, and 3) Open Flexible Type. These wall types lead the various changes in circulation, and even each of the arrangement qualities of the exhibitions should be researched according to its exhibition place type.

Effects of Daylight and Solar Radiation on Indoor Thermal Environment According to Space Structures in Multi-Complex Cultural Center (복합문화시설내 공간 구조에 따른 일조와 일사가 실내 온열환경에 미치는 영향)

  • Choi, Byungbo;Jeon, Hyun Sik;Yoon, Seokil;Kim, Sughwan;Lee, Sang-Jin;Kim, Sumin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.11
    • /
    • pp.751-758
    • /
    • 2012
  • Recently, people are paying attention to new forms of construction. For example, deviated from an enclosed type space, people have been interested in an atrium type and an arcade type spaces. In this study, we had hypothesis 'Indoor thermal environment will be influenced by the inflow rate of natural lights with temperature and humidity.' We selected a multi-complex cultural center and conducted this study. This place is consisted of atrium, arcade, and enclosed types. The three spaces were classified according to the type of spaces that have own features along with their forms. The atrium type space has ceiling and the side windows, and the arcade type space has ceiling windows. On the other hand, there are no windows or open parts in the enclosed type space. Three measurement points at each space were selected because of their huge space. Intensity of illumination, temperature and humidity were confirmed by the average value of three measurement points. In addition, surveys were conducted regarding indoor comfort elements in each space.

A Study on the Latter Baekje Dynasty Royal Tombs and Boundary of the Royal Tomb (백제 후기 능묘와 능원의 특성)

  • Kim, Young-sung
    • Korean Journal of Heritage: History & Science
    • /
    • v.47 no.2
    • /
    • pp.68-84
    • /
    • 2014
  • The royal tombs of Baekje(백제), after the transfer of the capital to the Geumgang(riv)(금강) basin, changed to Songsanri(송산리) style(stone chamber) ${\rightarrow}$ Southern dynastic(남조) style(brick chamber) ${\rightarrow}$ Neungsanri(능산리) style(stone chamber). The most special feature of this process is the change of the ceiling structure. The ceiling had been changed from dome(Songsanri style) ${\rightarrow}$ tunnel ceiling(transition period of brick tombs and Neungsanri style) ${\rightarrow}$ a roof style(is Neungsanri style of three imitate type, trapezoid, triangle, flattened ceiling). The most special feature among this process is Neungsanri style(stone chamber), created especially in Baekje. The royal tombs of Baekje didn't lay stress on the mound, so the mound is not noticeable. It is result that they more stressed on basin of the boundary than showed off individual tomb, and this is count as an element of China Southern dynasty. Boundary of the royal tomb of Baekje, after the transfer of the capital to south, were changed from royal family's boundary to single independent's. Those are Songsanri's and Neungsanri's, these are the pair tombs(쌍릉) of Iksan(익산). That is influence of the Southern dynasty, reflect the theory of divination based on topography completely, this is influence of the China Sui(수) and the early Tang(당) dynasty's system of boundary of the royal tomb. Besides the royal tomb, they also buried a closely related person, in the boundary of the royal tomb. And facilities for memorial ceremony were existed too. An altar was equipped in Songsanri's boundary of the royal tomb, it was seen a kind of character of a sanctuary for progenitor. Neungsanri's boundary of the royal tomb were equipped with an open-aired altar that performed memorial ceremony about communal royal tombs, and also equipped a temple, was needed to pray for the happiness of the dead. This structure and arrangement are very similar to Seoakdong(서악동) of Silla(신라).

The Kitchen furniture design Based on Stored items of Cooking Area in 40-pyung type apartment Houses (40평형 아파트 식생활용품 수납실태에 따른 부엌가구디자인)

  • Kim, Gi-In;Kim, Sun-Joong;Kwon, Myung-Hee
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.304-309
    • /
    • 2009
  • The purpose of this study is to develop kitchen furniture design for 40-pyung apartment Houses based on stored item of Cooking, Eating and Utility Area. The research data is gotten at a field study of stored items of Cooking, Eating and Utility Area and depth interview. The results of this study were as follows; 1)The kitchen furniture the preparation unit and the sink, the kitchen table, the heating unit and the service table, arranged at the tall storage. 2)The total bulk considered and holding volume ($2.7m^3$) with ground clearance (40%) planned with about $4.21m^3$. 3)Assumed at height and 162cm did a lower part height with 860mm and the upper depth 340mm, did with 700mm where raises. the storage the ceiling which raises will select and considered and with 2200mm did. 4)Arrangement of the kitchen the kitchen form which is an open type (L/DK or L.D.K) arranged many in forms of letter.

  • PDF

Methodology Study of Design Related to Accidental Explosion of Simple Explosive Storage Facility (화약류 간이저장소의 우발적 폭발을 고려한 안전설계 방법 연구)

  • Jung-Gyu, Kim;Seung-Won, Jung;Jun-Ha, Kim;Byung-Hee, Choi
    • Explosives and Blasting
    • /
    • v.40 no.4
    • /
    • pp.1-14
    • /
    • 2022
  • To review the appropriateness of current regulations on the simple explosive storage facility, the effects of internal explosion on the structural stability of the standard storage facility were analyzed by means of both FEM analyses and field experiments. As a result, it was found that the explosion-proof performance of the existing storage structure was not sufficient for 15 kg of emulsion-type explosive. Thus, an alternative method of splitting explosives was tested by conducting sympathetic detonation experiments. This method worked properly as expected, and the proper amount of splitted explosive was determined according to the test results. In addition, a storage structure with open ceiling was found to be very effective because explosion pressure was released so rapidly that the damage of the facility could be reduced significantly. Hence, such a structural pattern was proposed as a new design scheme for simple explosive storage facility.