Recently, people are paying attention to new forms of construction. For example, deviated from an enclosed type space, people have been interested in an atrium type and an arcade type spaces. In this study, we had hypothesis 'Indoor thermal environment will be influenced by the inflow rate of natural lights with temperature and humidity.' We selected a multi-complex cultural center and conducted this study. This place is consisted of atrium, arcade, and enclosed types. The three spaces were classified according to the type of spaces that have own features along with their forms. The atrium type space has ceiling and the side windows, and the arcade type space has ceiling windows. On the other hand, there are no windows or open parts in the enclosed type space. Three measurement points at each space were selected because of their huge space. Intensity of illumination, temperature and humidity were confirmed by the average value of three measurement points. In addition, surveys were conducted regarding indoor comfort elements in each space.

Keywords

References

  1. Yoon, C. S., 1992, Residential Design and Daylight, Architectural Institute of Korea, Vol. 36, No. 5, pp. 56-60.
  2. Kim, K. S., 1992, Daylight for the Energy Source- Daylighting for the Energy Conservation, Architectural Institute of Korea, Vol. 36, No. 5 pp. 45-49.
  3. Zimmons, P. M., 2004, The Influence of Lighting Quality on Presence and Task Performance in Virtual Environments.
  4. Kim, K., Park, P., and Kim, B. S., 2008, Survey and numerical effect analyses of the market structure and arcade form on the indoor environment of Closed-arcade markets during summer.
  5. Choi, C. B., 2010, A study of Atrium based on Eco-friendly Elements, Kukmin University, A master's thesis.
  6. Lee, J. Y., 2010, Using Passive Energy Utilization courtyard atrium space of the high-rise business facilities, Chungju University, Industral science research journal, Vol. 27, No. 2.
  7. Kim, Y. K., Kang, H. S., Kim, S. H., 2012, A study of Efficient Measures for Installing and Managing Traditional Market Arcades, Journal of Distribution Science, Vol. 10, No. 3, pp. 15-30.
  8. Kim, K. S. and Kim, Y. S., 1995, A Study on Evaluation of Heating, Cooling and Lighting Energy in Toplighted Atrium Buildings, 100 Architectural Institute of Korea, Vol. 11, No. 12, pp. 203-211.
  9. Cha, K. S., 1998, A Study on the Actual Survey․ Evaluation of the Atrium Environment in H Building, The Korean Solar Energy Society, pp. 408-415.
  10. Kim, S. H., 2011, A study of Multi Purpose Cultural Facilities for Communications aspects, The Spring Annual Conference of The AIK collection of dissertations, Vol. 31, No. 1, p. 6