• Title/Summary/Keyword: Open-type

Search Result 2,736, Processing Time 0.032 seconds

A Study on the Characteristics of an Unit Plan for a Tower Type Super-High-Rise-Residence (탑상형 초고층 주거건축의 단위평면 특성에 관한 연구 - 외기접합 면수별 공간구성 특성을 중심으로 -)

  • 이용광
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.5
    • /
    • pp.90-97
    • /
    • 2004
  • The purpose of this study is to grasp the spatial characteristic of the unit plan for a Super-High-Rise-Residence. This study is focused on the open air contact sides for a tower type Super-High-Rise-Residence. A tower type Super-High-Rise-Residence which has open air contacts from 1 to 3.5 sides differed in spatial characteristics of the unit plan for other apartment units. The current study analyzed 188 unit plans for the size of 40 pyong or larger in Seoul and the metropolitan areas which have been built since 1990. Open air contact side was classified as under 2 sides, 2 sides, and over 2 sides. The unit plan which belong to each open air contact side was Investigated according to the location of public area, the relationship between livingroom and master bedroom, and a method of entry to the master bedroom. The results of this study are as follow: According to increase open air contact sides is changed the location of public area in unit plan from an typical arrangement to various arrangement. Also the relationship between livingroom and master bedroom becomes loose and in a method of entry to the master bedroom increase an indirect approach through other room.

Operative Treatment of Displaced Talar Neck Fracture (전위된 거골 경부 골절의 수술적 치료)

  • Ahn, Jae-Hoon;Baek, Chang-Hyun;Choy, Won-Sik;Kim, Yong-In
    • Journal of Korean Foot and Ankle Society
    • /
    • v.10 no.2
    • /
    • pp.190-195
    • /
    • 2006
  • Purpose: To evaluate the results of open reduction and internal fixation for displaced talar neck fracture. Materials and Methods: Fourteen patients were followed for more than 1 year after open reduction and internal fixation of displaced talar neck fracture. The mean age was 41.5 years, and the mean follow-up period was 3.8 years. There were 10 type II, 3 type III and 1 type IV fractures per Hawkins. There were 3 open fractures. Clinically AOFAS ankle-hindfoot scale and Hawkins criteria were utilized. Radiologically quality of reduction, duration of bony union, avascular necrosis and posttraumatic arthritis were evaluated. Results: At last follow-up, AOFAS scale was mean 89.1 points. There were 8 excellent, 4 good, and 2 fair results according to Hawkins criteria. Radiologically anatomical reduction was obtained in 13 cases. Mean duration of bony union was 11.8 weeks. There were 3 avascular necrosis and 2 post-traumatic arthritis. There was no significant difference in the incidence of avascular necrosis between early operation group and surgically delayed group. Conclusion: Accurate open reduction and rigid internal fixation seem to be prerequisites for satisfactory treatment of a displaced talar neck fracture.

  • PDF

Long Term Results of Open Mitral Commissurotomy (개방성 승모판 교련 절제술의 장기 성적)

  • 김효윤
    • Journal of Chest Surgery
    • /
    • v.26 no.7
    • /
    • pp.521-525
    • /
    • 1993
  • Sixty-three patients who underwent open mitral commissurotomy at Sejong General Hospital during last 10 years from the August, 1983 to June, 1993 were reviewed There were fifty-one women and twelve men, and the mean age was 34.2 years. According to the NYHA classification, the distribution of patient preoperatively was as follows: class I, 5 patients ; class II, 26 patients ; class III, 30 patients ; class IV, 2 patients, and mean duration of symptome was 4.5 years. The mean mitral valvular area measured with echocardiogram preoperatively was 0.92cm2. All patients underwent open mitral commissurotomy and 41 patients required additional procedures for relief of subvalvular stenosis or other valvular disease. There were no operative death. 63 patients had three different types of mitral stenosis : type I, mobile cusps without subvalvular change [21 patients] ; typeII, thickened cusps with subvalvular change [34 patients] ; type III, rigid cusps with severe subvalvular change [8 patients]. The valvular calcification was seen in 11 patients [17%] and 15 patients [24%] had left atrial thrombus. The duration of follow-up was from 1 month to 168 months [mean, 39.6 months] and there were no late death. Six patients required reoperation and one patient had embolic episode. Conclusively,the open mitral commissurotomy represents a safe surgical precedure for treating mitral stenosis, allowing a complete removal of atrial thrombosis if present, and even when associated with subvalvular changes.

  • PDF

The Learning Motivation Types and Psychological Well-being of Middle-aged Married Women - Focused on the Students in Korea National Open University (중년기 기혼 여성의 학업동기 유형과 심리적 복지 - 방송대 재학생을 중심으로)

  • Park, Ji-Sun;Sung, Mi-Ai
    • Journal of Families and Better Life
    • /
    • v.26 no.3
    • /
    • pp.53-64
    • /
    • 2008
  • This study was to investigate the learning motive types and degree of psychological well-being of middle-aged married women attending the Korea National Open University and to examine the difference in their psychological well-being according to the types of learning motives. For these purposes, a survey was conducted to 263 middle-aged married women from 36 to 60 at the Korea National Open University. The findings were as follows: First, learning motive types of middle-aged women could be classified into 3 types; a non-oriented type, an activity and goal-oriented type and a multi-oriented type. A multi-oriented types were the most popular among those. Second, the overall level of self-respect was above the median, but the life satisfaction level was below the median. Third, there was difference in their self-respect level according to the learning motive types. That is, students who had a multi-oriented learning motive were higher self-respect level than those who had an activity and goal-oriented learning motive. Therefore, lifelong education is very significance in these days when average life span is prolonged.

The Study for Voice Onset Types in Benign Vocal Fold Lesions (양성성대질환에서의 발성시작유형에 관한 연구)

  • Kim, Seong-Tae;Ahn, Cheol-Min;Nam, Soon-Yuhl
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.20 no.2
    • /
    • pp.131-135
    • /
    • 2009
  • Background and Objectives: Benign vocal fold lesions have shown various voice onset types on phonation, however, they have not been documented yet. We studied to know the relationships between benign vocal fold lesions and voice onset types. Materials and Method: 114 subjects were evaluated by using videokymographic examinations. The subjects were classified into three types: normal, contact, and open types according to the patterns of voice onset types on phonation. Benign vocal fold lesions were investigated and voice onset types were compared between normal and disease groups. Voice parameters were obtained from and compared in all subjects to assess acoustic and aerodynamic factors. Results: The normal type among onset types were more than contact type or open type in both normal and disease groups. Disease group showed many contact and open types when. compared with normal group. Vocal nodule and vocal polyp were showed many normal and contact types, however, sulcus vocalis was almost showed open type among voice onset groups. The values of mean flow rate (MFR) of contact type were significantly higher compared to normal type in disease group (p<0.05). Shimmer of contact type was higher than normal type in diseasegroup, but the difference was not significant (p=0.057). Conclusion: Benign vocal fold lesions were related to the various types of voice onset. The various types of voice onset should be considered when benign vocal fold lesions were examined.

  • PDF

Measurements of absorption coefficients of open-type ceilings using 1:25 scale model reverberation chamber (축척모형을 활용한 개방형 천장의 흡음률 측정)

  • Lee, Hye-Mi;Kim, Yong-Hee;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.683-686
    • /
    • 2007
  • This paper investigates acoustical characteristics of open-type ceilings using 1:25 scale model. The field survey in the existing 15 halls was carried out to figure out the ceiling structure. The components of the open-type ceiling were mainly steel truss structures, duct, catwalk and finishing surfaces. In order to investigate the absorption characteristics of the equipped ceiling, the absorption coefficient measurements were made using 1:25 reverberation chamber based on ISO 354. Results showed that the absorption coefficient of the empty ceiling structure (6m-height) with 50%-perforated covering plate was 0.2-0.3 at above 500 Hz. When steel structure was added inside the empty ceiling, absorption coefficient increased by 0.16 at 250-1kHz. Adding catwalk did not increase the absorption, but adding duct increased the absorption at 1-2kHz. NRC of the equipped ceiling was 0.39, and the absorption characteristics were mainly found at high frequencies. In addition, the opening size of the covering plate did not change the absorption coefficient of the equipped ceiling meaningfully.

  • PDF

Operation Characteristics of Open Type Geothermal Heat Pump (개방형 지열 히트펌프 시스템의 운전 특성)

  • Lim, Hyo-Jae;Kong, Hyoung-Jin;Song, Yoon-Seok;Park, Seong-Koo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.701-706
    • /
    • 2006
  • Groundwater heat pump systems are the oldest of the ground-souce systems and it has various type. Standing column well type are must be located in hard rock geology site and produce sufficient water for the conventional open loop system. These system are indirect type(the building circulating loop and ground water are intercept). Existence of the exchanger the foundation protect water quality to use of open loop. The design of open loop system are concern on the power requirements. An experimental study was analysis the extremely heating operation COP of ground water heat pump system. Operation efficiency of the 50RT systems shows that, COP $2.9{\sim}5.0$ in heating operation. And generally it shows 3.4.

  • PDF

Result of Staged Operation in Ruedi-Allgower Type II and III Open Tibia Pilon Fractures with Severe Comminution (분쇄가 심한 Ruedi-Allgower II, III형의 개방성 경골 천정 골절에서 단계적 수술의 결과)

  • Choi, Kwi Youn;Lee, Jun Young;Jang, Hyunwoong;Kim, Young Wook
    • Journal of Korean Foot and Ankle Society
    • /
    • v.23 no.3
    • /
    • pp.110-115
    • /
    • 2019
  • Purpose: This study analyzed the clinical and radiological results of Reudi-Allgower type II and III open tibia pilon fracture patients who underwent plate fixation after the recovery of a soft tissue injury after external fixation. Materials and Methods: From 2010 to 2015, this study analyzed 14 patients who were treated for open tibial pilon fractures and could be followed up at least one year. The mean age was 49 years and the average follow-up period was 19 months. An emergency operation was performed for external fixation and open wounds, and secondary surgery was performed for definitive fixation using a plate. The radiological and clinical evaluations were analyzed retrospectively. Complications, such as post-traumatic osteoarthritis and wound infections were also analyzed. Results: The mean duration between two-staged surgery was 21 days and the mean bone union time was 9.2 months. Three cases of delayed union and one case of nonunion were reported. The malunion did not occur in all cases. The average American Orthopaedic Foot and Ankle Society (AOFAS) score was 68 points. A limitation of the ankle motion occurred in all cases. In four cases, wound infections due to initial open wounds occurred; one patient underwent a below the knee amputation due to chronic osteomyelitis. Post-traumatic arthritis occurred in 10 cases. Conclusion: Severe comminuted tibial plateau open fractures of Reudi-Allgower type II and III, which are high-energy injuries that result in extensive soft tissue damage, have a higher incidence of complications, such as ulcer problems and osteomyelitis, than closed tibia plateau fractures. Post-traumatic arthritis is the most common complication of tibia plateau open fractures, and staged surgery is recommended because of the relatively satisfactory clinical results.

Analysis of Ground Reaction Force by Stance Type during Tennis Forehand Stroke (테니스 포핸드 스트로크 스탠스 유형의 지면반력 분석)

  • Kang, Yong-Teak;Seo, Kook-Eun
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.3
    • /
    • pp.449-455
    • /
    • 2009
  • The purpose of this study was to analyze the kinetics variables of GRF by dtance type during forehand stroke. Eight high school tennis players, who have never been injured for last six months, in Busan were chosen for the study. They performed horizontal swing and vertical swing that it was done each five consecutive trial in the condition of square, semi-open and open stance. It was filmed by 6 video camera and used with 3-dimensional motion analyzer system and GRF system. The following kinetic variables were analyzed in relation to left leg and right leg GRF. The conclusion were as follow: 1. In square and semi-open stances, the horizontal ground reaction force was decreased at impact in left leg regardless of swing type, whereas open stance was increased at impact to the tiptoe in both legs. 2. In square and semi-open stances, the vertical ground reaction force was increased at impact in left leg regardless of swing types, whereas open stance was decreased at impact to vertical direction in both legs.

Comparative Assessment of Quality Changes in Refrigerated Foods Stored in Open-type and Door-type Refrigerators: Towards Developing Quality Indicators (냉장 중 품질변화 측정 지표 개발을 위한 냉장고 형태별(개방형 및 도어형) 저장 중 주요 냉장 식품의 품질변화 측정)

  • A-Ra Jang;Hyunji Song;Hyunwoo Joung;Euijin Choo;Sun-Young Lee
    • Journal of the FoodService Safety
    • /
    • v.4 no.1
    • /
    • pp.7-20
    • /
    • 2023
  • This study was conducted to investigate the impact of refrigerator type and temperature fluctuations on the quality changes of refrigerated foods. Phycochemical and sensory quality, as well as microbial growth, were measured for various foods stored in open- or door-type refrigerators set at 5℃ during storage. The average temperatures recorded were 11.50±1.14℃ in an open refrigerator, and 6.34±0.97℃ in a closed refrigerator. The average surface temperatures of the food items were 9.60±1.20 and 6.00±0.80℃ for open and closed refrigerators, respectively. Significant changes in color and appearance quality were observed in lettuce, mackerel, ground beef, and cut pineapples when stored in open refrigerators. Ready-to-Eat foods such as gimbap and sandwiches exhibited higher levels of microbiological proliferation when stored in open refrigerators compared to closed refrigerators. Processed foods, such as sterilized milk and packaged tofu, did not show significant differences in quality among various types of refrigerators. The installation of refrigerator doors can effectively minimize temperature fluctuations caused by external factors, thereby reducing variations in food quality. These findings provide essential insights into the quality changes associated with the implementation of refrigerator doors, serving as fundamental data for ensuring optimal food preservation.