• Title/Summary/Keyword: Open-gap

Search Result 339, Processing Time 0.025 seconds

A Novel discharging MEMS device & glow discharge properties (미소간극을 갖는 MEMS 방전 소자 제작 및 특성 연구)

  • Kim, Joo-Hwan;Moon, Hyoung-Sik;Kim, Young-Min
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.46-48
    • /
    • 2004
  • A micro-scale discharge device has been fabricated using MEMS technology and failure mechanisms during DC discharge are investigated for the microstructure. The failure of sustaining the plasma is mainly caused by either open or short of the micro-electrodes, both resulting from the sputtered metal atoms during the DC discharge. The glow discharge lifetime of the microstructures is found to depend on bias circuit scheme as well as the electrode structure. Based on the understanding of the failure mechanism, a novel microstructure is suggested to improve discharge lifetime and the longer lifetime is experimentally demonstrated. In addition to the failure mechanism, an electric breakdown between two electrodes with microns gap are studied using micromachined metal structures. The electrode gap is able to be accurately controlled by thickness of a sacrificial layer and the electric breakdown was measured while varying the gap from $2{\mu}m$ to $20{\mu}m$. The electric breakdown behavior was found to highly depend on the electrode material, which was not considered in Paschen's law.

  • PDF

THE COMPARING STUDY OF THE DIELECTRIC CHARACTERISTIC FROM THE LTCC MICROSTRIP RESONATOR ARCHITECTURES (LTCC MICROSTRIP RESONATOR 구조에 따른 유전특성 비교 연구)

  • Lee, Joong-Keun;Jung, Hyun-Chul;Yoo, Chan-Sei;Kim, Dong-Su;Yoo, Myung-Jae;Park, Sung-Dae;Lee, Woo-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.309-310
    • /
    • 2005
  • Generally, the dielectric constant and loss tangent are gotten by resonators. This paper presents analysis of the comparing the dielectric constant and loss tangent from the Ring, T and series gap structures. The T structure can be analyzed easily at wideband characteristic with simple design. the Ring can ignore the radiation loss from the open-ended effect. the Series gap can get more accurate permittivity than a Ring structure. The Used materials were dupont9599 LTCC ceramic and daeju0086 Ag.

  • PDF

Trading Risk Reduction Effects for Currency Futures Markets (통화선물거래의 거래위험 감소효과에 관한 연구)

  • Choi, Heung Sik;Kim, Sun Woong;Park, Eun-Jin
    • Journal of Information Technology Applications and Management
    • /
    • v.21 no.4
    • /
    • pp.1-13
    • /
    • 2014
  • This study aims to show the risk reduction effects of round-the-clock trading environment. We analyse the trading results of the currency futures contracts in CME Globex which are open 23 hours a day. These include Euro FX, Japanese Yen, Australian Dollar, and British Pound from January 2005 to August 2013. We generate new price series using only daytime prices during about 7-hour period. This hypothetical "G" data series may have greater gap risk than the original "R" data series. Empirical results show the trading risk reduction effects, that is R data series have higher profits and lower risks than G data series.

Redefining Liquidity for Monetary Policy

  • Kim, Kyunghun;Lee, Il Houng;Shim, Won
    • East Asian Economic Review
    • /
    • v.22 no.3
    • /
    • pp.307-336
    • /
    • 2018
  • This paper proposes a monetary aggregate "Liquidity" that could serve as a useful indicator for gauging the appropriateness of monetary policy. If liquidity rises above a certain threshold, it is signaling that monetary policy is losing traction due to structural and other impediments even when the inflation gap remains open. This indicator supplements the financial cycle approach but adds value by providing a benchmark that is derived from the national account, and not based on its own trend. Over the last two decades, each time this measure rose above the threshold range, it was followed by a decline in GDP growth. The latter was greater when accompanied by a high physical asset value to GDP, e.g., an elevated property market.

Quantum Simulation Study on Performance Optimization of GaSb/InAs nanowire Tunneling FET

  • Hur, Ji-Hyun;Jeon, Sanghun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.5
    • /
    • pp.630-634
    • /
    • 2016
  • We report the computer aided design results for a GaSb/InAs broken-gap gate all around nanowire tunneling FET (TFET). In designing, the semi-empirical tight-binding (TB) method using $sp3d5s^*$ is used as band structure model to produce the bulk properties. The calculated band structure is cooperated with open boundary conditions (OBCs) and a three-dimensional $Schr{\ddot{o}}dinger$-Poisson solver to execute quantum transport simulators. We find an device configuration for the operation voltage of 0.3 V which exhibit desired low sub-threshold swing (< 60 mV/dec) by adopting receded gate configuration while maintaining the high current characteristic ($I_{ON}$ > $100 {\mu}A/{\mu}m$) that broken-gap TFETs normally have.

EFFECTS OF GEOMETRIC PARAMETERS ON NUCLEATE POOL BOILING OF SATURATED WATER IN VERTICAL ANNULI

  • Kang, Myeong-Gie
    • Nuclear Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.271-278
    • /
    • 2009
  • Nucleate pool boiling of water in vertical annuli at atmospheric pressure has been studied experimentally and two empirical correlations have been suggested to obtain effects of geometric parameters on heat transfer. Data of the present and the previous tests range over a tube length of 0.50-0.57 m, a diameter of 16.5-34.0 mm, and an annular gap size of 3.7-44.3 mm. Through the analysis, tube bottom confinement (open or closed) has been investigated, as well. The developed correlations predict experimental data within a ${\pm}25%$ error bound. It has been identified that effects of the diameter and the length of heated tubes as well as the annular gap size should be counted into the analyses to estimate heat transfer coefficients accurately.

Ontology-lexicon-based question answering over linked data

  • Jabalameli, Mehdi;Nematbakhsh, Mohammadali;Zaeri, Ahmad
    • ETRI Journal
    • /
    • v.42 no.2
    • /
    • pp.239-246
    • /
    • 2020
  • Recently, Linked Open Data has become a large set of knowledge bases. Therefore, the need to query Linked Data using question answering (QA) techniques has attracted the attention of many researchers. A QA system translates natural language questions into structured queries, such as SPARQL queries, to be executed over Linked Data. The two main challenges in such systems are lexical and semantic gaps. A lexical gap refers to the difference between the vocabularies used in an input question and those used in the knowledge base. A semantic gap refers to the difference between expressed information needs and the representation of the knowledge base. In this paper, we present a novel method using an ontology lexicon and dependency parse trees to overcome lexical and semantic gaps. The proposed technique is evaluated on the QALD-5 benchmark and exhibits promising results.

Characteristics of the aero-acoustic noise generated from the inter-coach spacing of a high-speed train (고속열차의 차간 공간에서 발생하는 공력소음의 특성)

  • Park, Jun-Hong;Park, Chan-Kyung;Choi, Sung-Hoon
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1259-1263
    • /
    • 2006
  • The inter-coach spacing is one of the most important sources of the aero-acoustic noise of a high-speed train. When fluid at high speed flows over an open cavity, such as the inter-coach spacing, large acoustic pressure fields inside the cavity are produced by fluid/structure interactions at the downstream end of the cavity. In this study experiments were performed to investigate the characteristics the aero-acoustic noise generation from the inter-coach spacing of a high-speed train. Results of the measurement confirmed that the noise generated from the gap between mud-flaps are strongly dependent on the size of the gap.

  • PDF

Comparative accuracy of new implant impression technique using abutments as impression copings with an angulated implant model (경사지게 식립된 임플랜트 모형에서 지대주를 인상용 코핑으로 이용한 새로운 인상법의 정확성 비교 연구)

  • Lee, Hyeok-Jae;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.201-208
    • /
    • 2008
  • Statement of problem: A new implant impression technique which use abutments as impression coping, and use resin cement as a splinting material was described. Accuracy of this technique was compared with conventional closed tray and resin splinted open tray technique for a $15^{\circ}$ angled 3-implant model Material and methods: A dental stone master model with 3 linearly positioned implant analogue and a reference framework which was passively fitted to it were fabricated. The center analogue was perpendicular to the plane of model and the outer analogues had a $15^{\circ}$angulation forward or backward. 10 closed tray impressions, 10 resin splinted open tray impressions, 10 abutment-resin framework cementation impressions and 10 abutment-metal framework cementation impressions were made with additional silicone material and poured with dental stone. A light microscope with image processing was used to record the vertical gap dimension between reference framework and analogue of duplicated cast made with each 4 impression techniques. Statistical analysis used one-way ANOVA with post-hoc tests Tukey test of .05 level of significance Results: Significant difference in the vertical gap dimension was found between closed tray technique; 74.3 (${\pm}33.4$)${\mu}m$ and resin splinted open tray technique, and two other new technique. (P<.05) Abutment-metal framework cementation technique;42.5 (${\pm}11.9$)${\mu}m$ was significantly different from resin splinted open tray technique. (P<.05) Abutmentresin framework cementation technique;51.0 (${\pm}14.1$)${\mu}m$ did not differ significantly from resin splinted open tray technique;50.3 (${\pm}16.9$)${\mu}m$. (P>.05) Conclusion: Within limitations of this study, the accuracy of implant level impressions of resin splinted open tray technique was superior to that of closed tray technique. A new technique using abutment and metal framework cementation was more accurate than resin splinted open tray technique.

Study on Moisture Variation in Light Frame Wall with Different Wall Assemblies (II) - Moister Transfer of Light Frame Wall in Field Test - (벽체구성에 따른 목조벽체 내 수분변화에 대한 연구(II) - 외기에 노출된 목조벽체의 수분이동 -)

  • Kim, Se-Jong;Yeo, Hwan-Myeong;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.38 no.1
    • /
    • pp.56-65
    • /
    • 2010
  • The purpose of this study was finding out proper wall assembly to reduce moisture accumulation in light frame wall under outdoor air conditions. For the purpose, moisture transfer and accumulation in a wall were evaluated for five types of wall assembly; typical wall (T), addition of a vapor retarder (P1), addition of two vapor retarders (P2), addition of an open air gap for ventilation behind the siding (P3), and shift of vapor retarder with proposed wall 'P3' (P4). The moisture transfer and accumulation in the all walls were evaluated after applying the typical and proposed walls to the field test house. Performances of the typical and proposed walls were compared according to the season. Rank for effective wall on reducing moisture accumulation in wall was 1) shift of vapor ratarder and addition of open air gap (P4), 2) addition of vapor retarder (P1), 3) typical wall (T), 4) addition of open air gap (P3), and 5) the other (P2).