• 제목/요약/키워드: Open-circuit voltage

검색결과 609건 처리시간 0.029초

THE OPEN-CIRCUIT VOLTAGE STATE ESTIMATION OF THE BATTERY

  • LEE, SHINWON
    • Journal of applied mathematics & informatics
    • /
    • 제39권5_6호
    • /
    • pp.805-811
    • /
    • 2021
  • Currently, batteries use commonly as energy sources for mobile electric devices. Due to the high density of energy, the energy storage state of a battery is very important information. To know the battery's energy storage state, it is necessary to find out the open state voltage of the battery. The open state voltage calculates with a mathematical model, but the computation of the real time state is complicated and requires many calculations. Therefore, the state observer designs to estimate in real time the battery open-circuit voltage as disturbance including model error. Using the estimated open voltage and applying it to the state estimation algorithm, we can estimate the charge. In this study, we first estimate the open-circuit voltage and design an estimation algorithm for estimating the state of battery charge. This includes errors in the system model and has a robust characteristic to noise. It is possible to increase the precision of the charge state estimation.

Laser Fired Contact 태양전지 개발을 위한 Screen Printed Laser Back Contact의 최적 $SiN_X$ 두께 분석

  • 이원백;이용우;장경수;정성욱;이준신
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.280-280
    • /
    • 2010
  • 태양전지의 효율을 증가시키는 방법에는 표면 패시베이션, 접촉면적의 가변, back contact의 두께 가변 등이 있다. 특히, back contact 두께의 가변을 통하여 open circuit voltage의 감소를 최소화 할 수 있을 것이라고 전망 되고 있다. open circuit voltage 은 회로가 개방된 상태로, 무한대의 임피던스가 걸린 상태에서 빛을 받았을 때 태양전지의 양단에 전위차가 형성된다. 본 연구에서는 back contact 두께 가변에 따른, open circuit voltage의 변화를 확인하고 분석하는 것에 그 일차적인 초점을 두었다. 또한, open circuit voltage 뿐만 아니라, short circuit current density, fill factor, series resistance 등의 분석을 하였으며, efficiency를 계산하여 back contact 두께의 가변에 따른 소자 특성의 변화 분석을 통하여 최적화된 back contact위 두께를 연구하였다. 접촉면적에 따른 소자의 성능 변화는 후면 $SiN_X$ 70nm가 open circuit voltage를 15mV ~ 20mV 감소시키는 것을 확인 할 수 있었다. 그 이유는 $SiN_X$가 너무 두꺼우면 BSF 덜 형성되기 때문이다. 최종적으로 $SiN_X$ 두께를 얇게하면 open circuit voltage 의 감소를 최소화 할 수 있을 것이라는 판단을 할 수 있다. 이에, back contact인 $SiN_X$ 두께 가변에 따른 open circuit voltage의 변화를 확인하였다. $SiN_X$ 두께가 증가함에 따라, Positive charges 와 Hydrogen 함유량이 증가하며, 이에 BSF 두께 감소하였다. 또한, $SiN_X$ 두께가 감소함에 따라 Doping barrier로서 역할을 못하게 되어 후면에 n+층 형성되어 open circuit voltage가 급격히 하락하였다. 본 연구에서는 back contact인 $SiN_X$ 두께를 10nm, 30nm, 50nm, 80nm 로 가변하며 실험을 진행하였다.

  • PDF

저온형 SOFC용 GDC 전해질 두께에 따른 Open Circuit Voltage 향상 (Improvement of Open Circuit Voltage (OCV) depending on Thickness of GDC Electrolyte of LT-SOFCs)

  • 고현준;이종진;현상훈
    • 한국세라믹학회지
    • /
    • 제47권2호
    • /
    • pp.195-198
    • /
    • 2010
  • It has been considered to apply GDC ($Gd_{0.1}Ce_{0.9}O_{1-X}$) for low-temperature SOFC electrolytes because it has higher ionic conductivity than YSZ at low temperature. However, open circuit voltage with using GDC ($Gd_{0.1}Ce_{0.9}O_{1-X}$) electrolyte in SOFCs, becomes lower than using YSZ (8 mol% Yttria stabilized Zirconia) electrolyte because GDC has electronic conductivity. In this work, the effect of changing GDC electrolyte thickness on the open circuit voltage has been investigated. Ni-GDC anode-supported unit cells were fabricated as follows. Mixed NiO-GDC powders were pressed and pre-sintered at $1200^{\circ}C$. And then, GDC electrolyte material was dip-coated on the anode and sintered at $1400^{\circ}C$. Finally the LSCF-GDC cathode material was screen-printed on the electrolyte and sintered at $1000^{\circ}C$. Electrolyte thickness was controlled by the number of dip-coating times. Open circuit voltage was measured depending on electrolyte thickness at $650^{\circ}C$ and found that the thicker GDC electrolyte was, the better OCV was.

A Comparative Study of Two Diagnostic Methods Based on the Switching Voltage Pattern for IGBT Open-Circuit Faults in Voltage-Source Inverters

  • Wang, Yuxi;Li, Zhan;Xu, Minghui;Ma, Hao
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1087-1096
    • /
    • 2016
  • This paper reports an investigation conducted on two diagnostic methods based on the switching voltage pattern of IGBT open-circuit faults in voltage-source inverters (VSIs). One method was based on the bridge arm pole voltage, and the other was based on bridge arm line voltage. With an additional simple circuit, these two diagnostic methods detected and effectively identified single and multiple open-circuit faults of inverter IGBTs. A comparison of the times for the diagnosis and anti-interference features between these two methods is presented. The diagnostic time of both methods was less than 280ns in the best case. The diagnostic time for the method based on the bridge arm pole voltage was less than that of the method based on the bridge arm line voltage and was 1/2 of the fundamental period in the worst case. An experimental study was carried out to show the effectiveness of and the differences between these two methods.

Couette 흐름현상을 이용한 초고압변압기의 유동대전 기구 연구 (A Study on the Electrification Mechanism in UHV Transformer by Couette Flow)

  • 곽희로;정용기;권동진
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제9권4호
    • /
    • pp.93-102
    • /
    • 1995
  • The purpose of this paper is to analyze the streaming electrification mechanism (SEM) generated in UHV transformer. This experiment used Couette Charger and interpreted the mechanism hydromechanically and electromagnetically. This work estimated the turbulent core density ($\rho$o) by measuring the short circuit current (isc) and the open circuit voltage (νoc) generated in Couette Charger and also studied the changes of the short circuit (isc), the open circuit voltage (νoc), the turbulent core density ($\rho$o) and the conductivity ($\sigma$) with adding BTA to restrain streaming electrification. as a result adding BTA increased the conductivity of oil and decreased the turbulent core density($\rho$o).

  • PDF

A Current Dynamic Analysis Based Open-Circuit Fault Diagnosis Method in Voltage-Source Inverter Fed Induction Motors

  • Tian, Lisi;Wu, Feng;Shi, Yi;Zhao, Jin
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.725-732
    • /
    • 2017
  • This paper proposed a real-time, low-cost, fast transistor open-circuit fault diagnosis method for voltage-source inverter fed induction motors. A transistor open-circuit changes the symmetry of the inverter topology, leading to different similarities among three phase load currents. In this paper, dynamic time warping is proposed to describe the similarities among load currents. The proposed diagnosis is independent of the system model and needs no extra sensors or electrical circuits. Both simulation and experimental results show the high efficiency of the proposed fault diagnosis method.

A nuclear battery based on silicon p-i-n structures with electroplating 63Ni layer

  • Krasnov, Andrey;Legotin, Sergey;Kuzmina, Ksenia;Ershova, Nadezhda;Rogozev, Boris
    • Nuclear Engineering and Technology
    • /
    • 제51권8호
    • /
    • pp.1978-1982
    • /
    • 2019
  • The paper presents the electrical performance measurements of a prototype nuclear battery and two types of betavoltaic cells. The electrical performance was assessed by measuring current-voltage properties (I-V) and determining the short-circuit current and the open-circuit voltage. With 63Ni as an irradiation source, the open-circuit voltage and the short-circuit current were determined as 1 V and 64 nA, respectively. The prototype consisted of 10 betavoltaic cells that were prepared using radioactive 63Ni. Electroplating of the radioactive 63Ni on an ohmic contact (Ti-Ni) was carried out at a current density of 20 mA/㎠. Two types of betavoltaic cells were studied: with an external 63Ni source and a 63Ni-covered source. Under irradiation of the 63Ni source with an activity of 10 mCi, the open-circuit voltage Voc of the fabricated cells reached 151 mV and 109 mV; the short-circuit current density Jsc was measured to be 72.9 nA/cm2 and 64.6 nA/㎠, respectively. The betavoltaic cells had the fill factor of 55% and 50%, respectively.

Probeless Estimation of Electroluminescence Intensities Based on Photoluminescence Measurements of GaN-Based Light-Emitting Diodes

  • Kim, Jongseok;Jeong, Hoon;Choi, Won-Jin;Jung, Hyundon
    • Current Optics and Photonics
    • /
    • 제5권2호
    • /
    • pp.173-179
    • /
    • 2021
  • The electroluminescence (EL) intensities of GaN-based light-emitting diodes (LEDs) are estimated based on their photoluminescence (PL) properties. The PL intensity obtained under open-circuit conditions is divided into two parts: the PL intensity under a forward bias lower than the optical turn-on voltage, and the difference between the PL intensities under open-circuit conditions and under forward bias. The luminescence induced by photoexcitation under a constant forward bias lower than the optical turn-on voltage is primarily the PL from the excited area of the LED. In contrast the intensity difference, obtained by subtracting the PL intensity under the forward bias from that under open-circuit conditions, contains the EL induced by the photocarriers generated during photoexcitation. In addition, a reverse photocurrent is generated during photoexcitation under constant forward bias across the LED, and can be correlated with the PL-intensity difference. The relationship between the photocurrent and PL-intensity difference matches well the relationship between the injection current and EL intensity of LEDs. The ratio between the photocurrent generated under a bias and the short-circuit current is related to the ratio between the PL-intensity difference and the PL intensity under open-circuit conditions. A relational expression consisting of the ratios, short-circuit current, and PL under open-circuit conditions is proposed to estimate the EL intensity.

선박용 2.5[kW] HID 탐사등의 Soft-Start 방식에 의한 개방회로 전압과 점등전류 순차 제어 (Soft-Start Open Circuit Voltage and Constant Current Sequence Control of 2.5[kW] HID Search Lamp for Ship)

  • 박노식;권순재;이동희
    • 조명전기설비학회논문지
    • /
    • 제22권8호
    • /
    • pp.45-51
    • /
    • 2008
  • 본 논문에서는 2.5[kW]급 선박용 HID 탐사등 조명을 위한 Soft-start 개방회로 전압 및 정전류 순차 제어 방식을 제안한다. 제안된 제어회로는 HID 탐사등의 안정적인 점등을 위하여 개방회로 전압과 점등 전류를 순차적으로 제어하는 방식으로, 특히 전원투입 상태에서의 안정성을 위하여 일정한 입력전압에 대해서 Soft-start 기법을 적용하여 개방회로 전압 제어모드로 동작하도록 설계되었다. 또한, 점등개시 신호의 입력에 따라 제어모드를 전압제어에서 전류 제어모드로 변경하여 단일 PWM 제어소자에서 동시에 처리하도록 하였다. 한편, 입력 노이즈 및 개방회로 전압의 검출을 간단한 원칩 마이크로 프로세서로 구현하여, 오동작 및 점등 실패에 대한 강인성을 부가하도록 하였다. 제안된 제어기는 실제 선박용 HID 탐사등의 적용 시험을 통하여 그 안정성을 시험하였다.

MPPT 제어 기능을 갖는 열에너지 하베스팅 회로 설계 (Design of a Thermal Energy Harvesting Circuit with MPPT Control)

  • 윤은정;김수진;박금영;오원석;유종근
    • 한국정보통신학회논문지
    • /
    • 제16권11호
    • /
    • pp.2487-2494
    • /
    • 2012
  • 본 논문에서는 MPPT 제어 기능을 갖는 열에너지 하베스팅 회로를 설계하였다. MPPT(Maximum Power Point Tracking) 제어는 열전소자의 개방회로전압과 MPP 전압간의 관계를 이용하였으며 열전소자의 개방회로전압을 주기적으로 샘플링 함으로써 이를 이용해 MPPT 기준전압을 생성하여 이를 기준으로 부하로의 에너지 공급을 제어한다. 모의실험 결과 94%의 최대 전력 효율을 보였다. 제안된 열에너지 하베스팅 회로는 $0.35{\mu}m$ CMOS 공정으로 설계하였으며 설계된 칩 면적은 PAD를 제외하고 $1168.7{\mu}m{\times}541.3{\mu}m$이다.