• Title/Summary/Keyword: Open loop

Search Result 848, Processing Time 0.028 seconds

Positive Position Feedback Control of Plate Vibrations using Moment Pair Actuators (모멘트상 액추에이터가 적용된 평판의 PPF 능동제어)

  • Shin, Chang-Joo;Hong, Chin-Suk;Jeong, Weui-Bong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.527-535
    • /
    • 2012
  • This paper reports the active vibration control of plates using positive position feedback controller (PPF). The equations of motion of the plate under force and moment pairs were derived and the equations of PPF controllers were formulated. The effect of the parameters - gain and damping ratio - of the PPF controllers on the open loop transfer function was investigated mainly in terms of the system stability. Increasing the gain of the PPF controller tuned at a mode, the magnitude of the open loop transfer function is increased at all frequencies without changing the phase behavior. The increase of the damping ratio of the PPF controller leads to decrease the magnitude of the open loop transfer function and to modify its phase characteristics to be more stable. Two PPF controllers connected in parallel, Each PPF controller is tuned at the $1^{st}$ and $2^{nd}$ modes, respectively. Their parameters were determined to remain the system to be stable based on the results of the parametric study. A significant reduction in vibration at the 2 modes can be obtained.

  • PDF

Active Control of Clamped Beams using Acceleration Feedback Controllers (가속도 되먹임 제어기를 이용한 양단지지보의 능동 제어)

  • Shin, Chang-Joo;Hong, Chin-Suk;Jeong, Weui-Bong;Jeong, Sang-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.12
    • /
    • pp.1190-1199
    • /
    • 2010
  • This paper reports active control of clamped beams using acceleration feedback controllers (AF). The equations of motion of clamped beam under force and moment pairs were derived and the equations of AF controllers were formulated. The effect of the parameters - gain and damping ratio - of the AF controllers on the open loop transfer function was investigated mainly in terms of the system stability. Increasing the gain of the AF controller tuned at a mode, the magnitude of the open loop transfer function is increased at all frequencies. The increase of the damping ratio of the AF controller leads to decrease the magnitude of the open loop transfer function and modifies its phase characteristics to be more stable. Three AF controllers connected in parallel were then proposed. Each AF controller is tuned at the 2nd, 3rd and 4th modes, respectively. Their parameters were determined to remain the system to be stable based on the results of the parametric study. A significant reduction in vibration at the 3 modes can be obtained.

Performance Analysis of the Open Loop Transmitter and Receiver Diversity in the Wide Band CDMA network (광대역 부호분할다원접속(WCDMA) 이동통신 환경하에서 송수신 다이버시티 기법의 성능 분석)

  • Park Sang-Jo;Roh Yong-Woo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.2 s.40
    • /
    • pp.201-211
    • /
    • 2006
  • The standardization of third Generation Partnership Project(3GPP) has been performed in of order to support interactive multimedia services under mobile environments. In this 3GPP, transmit diversity solutions are applied to increase the available diversity effectively using 2 or more antennas. In this paper, we analyzer the performances on STTD(Space Time Transmit Diversity) technique and its modified techniques such as STTD-OTD, CL-STTD, and 4TX-STTD out of open loop transmit diversities that the standardization of 3GPP has released. We also propose the open loop transmitter and receiver diversities to add the receiver diversity. We analyze and discuss the performance of the proposed techniques and using the Matlab simulation under the flat fading channel environment.

  • PDF

A 1.5V 70dB 100MHz CMOS Class-AB Complementary Operational Amplifier (1.5V 70dB 100MHz CMOS Class-AB 상보형 연산증폭기의 설계)

  • 박광민
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.9
    • /
    • pp.743-749
    • /
    • 2002
  • A 1.5V 70㏈ 100MHz CMOS class-AB complementary operational amplifier is presented. For obtaining the high gain and the high unity gain frequency, the input stage of the amplifier is designed with rail-to-rail complementary differential pairs which are symmetrically parallel-connected with the NMOS and the PMOS differential input pairs, and the output stage is designed to the rail-to-rail class-AB output stage including the elementary shunt stage technique. With this design technique for output stage, the load dependence of the overall open loop gain is improved and the push-pull class-AB current control can be implemented in a simple way. The designed operational amplifier operates perfectly on the complementary mode with 180$^{\circ}$ phase conversion for 1.5V supply voltage, and shows the push-pull class-AB operation. In addition, the amplifier shows the DC open loop gain of 70.4 ㏈ and the unity gain frequency of 102 MHz for $C_{L=10㎊∥}$ $R_{L=1㏁}$ Parallel loads. When the resistive load $R_{L}$ is varied from 1 ㏁ to 1 ㏀, the DC open loop gain of the amplifier decreases by only 2.2 ㏈.a$, the DC open loop gain of the amplifier decreases by only 2.2 dB.

Operation Characteristics of Open Type Geothermal Heat Pump (개방형 지열 히트펌프 시스템의 운전 특성)

  • Lim, Hyo-Jae;Kong, Hyoung-Jin;Song, Yoon-Seok;Park, Seong-Koo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.701-706
    • /
    • 2006
  • Groundwater heat pump systems are the oldest of the ground-souce systems and it has various type. Standing column well type are must be located in hard rock geology site and produce sufficient water for the conventional open loop system. These system are indirect type(the building circulating loop and ground water are intercept). Existence of the exchanger the foundation protect water quality to use of open loop. The design of open loop system are concern on the power requirements. An experimental study was analysis the extremely heating operation COP of ground water heat pump system. Operation efficiency of the 50RT systems shows that, COP $2.9{\sim}5.0$ in heating operation. And generally it shows 3.4.

  • PDF

A Modified Microstep Drive of PM Step Motor (PM 스텝 모터의 개선된 마이크로 스텝 구동)

  • Lee, Tae-Gyoo;Shin, Ki-Sang;Huh, Uk-Youl
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.15-17
    • /
    • 1996
  • In this paper, a modified microstep drive of PM step motor is presented. The open-loop drive of a step motor is attractive and widely accepted in applications of speed and position controls. However, the performance of the step motor is limited under the open-loop drive. The closed-loop control is advantages over the open-loop control not only in that step failure never occurs but that the motion is much quicker and smoother. However, a high resolution sensor is needed for detecting position and speed. The modified microstep drive is constructed as a microstep drive with speed feedback. The advantages of the proposed method is that the controller can be designed by a low resolution sensor and is simpler than other closed-loop controller. A concept of vector control is used for verifying the proposed scheme. Simulations show the performance of the proposed method and a comparison with a classic drive method.

  • PDF

Performance Analysis of Ground Heat Exchanger in Combined Well and Open-Closed Loops Geothermal (CWG) System (밀폐형과 개방형이 결합된 복합지열시스템의 지중열교환기 성능 분석)

  • Park, Youngyun;Song, Jae-Yong;Lee, Geun-Chun;Kim, Ki-Joon;Mok, Jong-Koo;Park, Yu-Chul
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.5
    • /
    • pp.23-29
    • /
    • 2017
  • This study was conducted to evaluate performance of geothermal heat exchanger (GHE) in the combined well and open-closed loops geothermal (CWG) systems. The CWG systems were designed to combine open loop geothermal heat pumps and closed loop geothermal heat pumps for high energy efficiency. GHE of the CWG systems could be installed at pumping wells for agricultural usage. To get optimal heat exchange capacity of GHE of the CWG systems, 4 GHEs with various materials and apertures were tested at laboratory scale. Polyethylene (PE) and stainless steel (STS) were selected as GHE materials. The maximum heat exchange capacity of GHEs were estimated to be in the range of 33.0~104 kcal/min. The heat exchange capacity of STS GHEs was 2.4~3.2 times higher than that of PE GHE. The optimal cross section area of GHE and flow rate of circulating water of GHE were estimated to be $2,500mm^2$ and 113 L/min, respectively. For more complicated GHE of the CWG systems, it is necessary to evaluate GHEs at various scales.

Low Phase Noise VCO Using Microstrip Square Open Loop Resonator and Tunable Negative Resistance (Microstrip Square Open Loop와 Tunable Negative Resistance를 이용한 저위상 잡음 전압 제어 발진기)

  • Choi, Jae-Won;Lee, Chong-Min;Seo, Chul-Hun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.12 s.115
    • /
    • pp.1143-1149
    • /
    • 2006
  • The microstrip square open loop resonator has been employed to reduce the phase noise in VCO. The microstrip square open loop resonator has the large coupling coefficient value, which makes a high Q value, and has reduced the phase noise of VCO. To increase the tuning range of VCO, varactor diode has been connected at the tunable negative resistance in VCO. The output power and harmonic characteristics of VCO has been obtained 4.83 dBm and -28.83 dBc, respectively. The phase noise of VCO has been $-112.33{\sim}-116.16dBc/Hz$ @ 100 kHz in the tuning range, $5.735{\sim}5.845GHz$.

Low Phase Noise Push-Push VCO Using Microstrip Square Open Loop Resonator and Tunable Negative Resistance (마이크로스트립 사각 개방 루프 공진기와 가변 부성 저항을 이용한 저위상 잡음 Push-Push 전압 제어 발진기)

  • Choi, Jae-Won;Seo, Chul-Hun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.8
    • /
    • pp.847-853
    • /
    • 2007
  • In this paper, a novel push-push voltage-controlled oscillator(VCO) using microstrip square open loop resonator and tunable negative resistance is presented. The microstrip square open loop resonator has the large coupling coefficient value, which makes a high Q value, and has reduced phase noise of VCO. The VCO with 1.8V power supply has phase noise of $-124.67{\sim}-122.67dBc/Hz\;@\;100 kHz$ in the tuning range, $5.744{\sim}5.859 GHz$. The FOM of this VCO is $-202.83{\sim}-201dBc/Hz\;@\;100 kHz$ in the same tuning range. When it has been compared with single-ended VCO using microstrip square open loop resonator, and push-push oscillator using microstrip line resonator, the reduced phase noise has been -8.51dB, and -33.67dB, respectively.

A Study on Significant Parameters for Efficient Design of Open-loop Groundwater Heat Pump (GWHP) Systems (개방형 지열시스템의 효율적 설계를 위한 영향인자에 대한 연구)

  • Park, Byeong-Hak;Joun, Won-Tak;Lee, Bo-Hyun;Lee, Kang-Kun
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.4
    • /
    • pp.41-50
    • /
    • 2015
  • Open-loop groundwater heat pump (GWHP) system generally has benefits such as a higher coefficient of performance (COP), lower initial cost, and flexible system size. The hydrogeological conditions in Korea have the potential to facilitate the use of the GWHP system because a large number of monitoring wells show stable groundwater temperatures, shallow water levels, and high well yields. However, few studies have been performed in Korea regarding the GWHP system and the most studies among them dealt with Standing Column Well (SCW). Because the properties of the aquifer have an influence on designing open-loop systems, it is necessary to perform studies on various hydrogeological settings. In this study, the hydrogeological and thermal properties were estimated through various tests in the riverside alluvial layer where a GWHP system was installed. Under different groundwater flow velocities and pumping and injection rates, a sensitivity analysis was performed to evaluate the effect of such properties on the design of open-loop systems. The results showed that hydraulic conductivity and thermal dispersivity of the aquifer are the most sensitive parameters in terms of performance and environmental aspects, and sensitivities of the properties depend on conditions.