Development of Defect Inspection System for PDP ITO Patterned Glass (PDP ITO 패턴유리의 결함 검사시스템 개발)

  • Song Jun Yeob;Park Hwa Young;Kim Hyun Jong;Jung Yeon Wook
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.12
    • /
    • pp.92-99
    • /
    • 2004
  • The formation degree of sustain (ITO pattern) decides quality of PDP (Plasma Display Panel). For this reason, it makes efforts in searching defects more than 30 un as 100%. Now, the existing inspection is dependent upon naked eye or microscope in off-line PDP manufacturing process. In this study developed prototype inspection system of PDP 170 glass is based on line-scan mechanism. Developed system creates information that detects and sorts kinds of defect automatically. Designed inspection technology adopts multi-vision method by slip-beam formation for the minimum of inspection time and detection algorithm is embodied in detection ability of developed system. Designed algorithm had to make good use of kernel matrix that draws up an approach to geometry. A characteristic of defects, as pin hole, substance, protrusion, are extracted from blob analysis method. Defects, as open, short, spots and et al, are distinguished by line type inspection algorithm. In experiment, we could have ensured ability of inspection that can be detected with reliability of up to 95% in about 60 seconds.

The Analytic Analysis of Suppressing Jet Flow at Guide Tube of Circular Irradiation Hole in HANARO (하나로 원형 조사공의 안내관 제트유동 억제에 대한 해석)

  • Park Y. C.;Wu S. I.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.03a
    • /
    • pp.214-219
    • /
    • 2004
  • The HANARO, a multi-purpose research reactor of 30 MWth, open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. The HANARO is composed of inlet plenum, grid plate, core channel with flow tubes and chimney. The reactor core channel is located at about twelve m (12 m) depth of the reactor pool and cold by the upward flow that the coolant enters the lower inlet of the plenum, rises up through the grid plate and the core channel and exit through the outlet of chimney. A guide tube is extended from the reactor core to the top of the reactor chimney for easily un/loading a target under the reactor normal operation. But active coolant through the core can be Quickly raised up to the top of the chimney through the guide tube by jet flow. This paper is described an analytical analysis to study the flow behavior through the guide tube under reactor normal operation and unloading the target. As results, it was conformed through the analysis results that the flow rate, about fourteen kilogram per second (14 kg/s) suppressed the guide tube jet and met the design cooling flow rate in a circular flow tube, and that the fission moly target cooling flow rate met the minimum flow rate to cool the target.

  • PDF

Wavelet Transform Based Defect Detection for PCB Inspection Machines (PCB 검사기를 위한 웨이블릿 변환 기반의 결함 검출 방법)

  • Youn, Seung-Geun;Kim, Young-Gyu;Park, Tae-Hyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.10
    • /
    • pp.1508-1515
    • /
    • 2017
  • This paper proposes the defect detection method for automatic inspection machines in printed circuit boards (PCBs) manufacturing system. The defects of PCB such as open, short, pin hole and scratch can be detected by comparing the standard image and the target image. The standard image is obtained from CAD file such as ODB++ format, and the target image is obtained by arranging, filtering and binarization of captured PCB image. Since the PCB size is too large and image resolution is too high, the image processing requires a lot of memory and computational time. The wavelet transform is applied to compress the standard and target images, which results in reducing the memory and computational time. To increase the inspection accuracy, we utilize the he HH-domain as well as LL-domain of the transformed images. Experimental results are finally presented to show the performance improvement of the proposed method.

A Novel Ultraviolet Sensor using Photoluminescent Porous Silicon (광 루미네슨스 다공질 실리콘을 이용한 새로운 자외선 센서)

  • Min, Nam-Gi;Go, Ju-Yeol;Gang, Cheol-Gu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.9
    • /
    • pp.444-449
    • /
    • 2001
  • In this paper, a novel ultraviolet sensor is presented based on a photoluminescent porous silicon. Porous silicon layer was formed by chemical etching of surface of pn junction in a $HF(48%)-HNO_3(60%)-H_20$ solution. Incident ultraviolet(UV) light is converted to visible light by photoluminescent porous silicon layer, and then this visible light generates electron-hole pairs in the pn junction, which produces a photocurrent flow through the device. In order to maximize detection efficiency, the peak sensitivity wavelength of the pn junction diode was matched with the peak wavelength of Photoluminescence from porous silicon layer. The porous silicon ultraviolet sensor showed a large output current as UV intensity increases and but very low sensitivity to visible light. The detection sensitivity of porous silicon sensor was calculated as 2.91mA/mW. These results are expected to open up a possibility that the present porous silicon sensor can be used for detecting UV light in a visible background, compared to silicon UV detectors which have an undesirable response to visible light.

  • PDF

Extended Pneumocephalus after Drainage of Chronic Subdural Hematoma Associated with Intracranial Hypotension : Case Report with Pathophysiologic Consideration

  • Shin, Hee Sup;Lee, Seung Hwan;Ko, Hak Cheol;Koh, Jun Seok
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.1
    • /
    • pp.69-74
    • /
    • 2016
  • Chronic subdural hematoma (SDH) is a well-known disease entity and is traditionally managed with surgery. However, when associated with spontaneous intracranial hypotension (SIH), the treatment strategy ought to be modified, as classical treatment could lead to unwanted consequences. A 59-year-old man presented with a case of SIH that manifested as a bilateral chronic SDH. He developed fatal extensive pneumocephalus and SDH re-accumulation as a complication of burr-hole drainage. Despite application of an epidural blood patch, the spinal cerebrospinal fluid leak continued, which required open spinal surgery. Chronic SDH management should not be overlooked, especially if the exact cause has not been determined. When chronic SDH assumed to be associated with SIH, the neurosurgeon should determine the exact cause of SIH in order to effectively correct the cause.

An Experimental Study on the Impulse Noise Emitted from the Exit of a Perforated Pipe (다공관 출구로부터 방사된 충격성 소음에 관한 실험적 연구)

  • Heo, Sung-Wook;Je, Hyun-Su;Yang, Soo-Young;Lee, Dong-Hoon
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2066-2070
    • /
    • 2003
  • This experimental study describes the propagation characteristics and suppression of the impulse noise emitted from the exit of a perforated pipe attached to the open end of a simple shock tube. The experiment is performed through the systematic change of the shock wave Mach number and the geometrical parameters such as the porosity, hole diameter and length of the perforated pipe. The experimental results for the near and far sound field are presented and explained in comparison with those for a straight pipe. The results obtained show that for the near sound field the impulse noise strongly propagates toward to the pipe axis, but for the far sound field the impulse noise uniformly propagates toward to the all directions, indicating that the directivity pattern is almost same regardless of the pipe type. Moreover, the noise reduction performance of perforated pipe depends upon the condition of sound field. For the near sound field the perforated pipe has a little performance to suppress the impulse noise, but for the far sound field the perforated pipe has little performance to suppress the impulse noise.

  • PDF

A Study on Inspection Technology of PDP ITO Defect (PDP ITO 결함 검출기술에 관한 연구)

  • 송준엽;박화영;정연욱;김현종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.191-195
    • /
    • 2003
  • The formation degree of sustain (ITO pattern) decides quality of PDP (plasma display panel). For this reason. it makes efforts in search defects more than 30 ${\mu}{\textrm}{m}$. Now, the existing inspection process is dependent upon naked eye or SEM equipment in off-line PDP manufacturing process. In this study developed prototype inspection system of PDP ITO glass. This system creates information that detects and sorts kind of defect automatically. Design ed inspection technology adopts line-scan method by slip-beam formation for the minimum of inspection time and image processing algorithm is embodied in detection ability of developed system. Designed algorithm had to make good use of kernel matrix which draws up an approach to geometry. A characteristic of area-shaped defects, as pin hole, substance, protrusion et al, are extracted from blob analysis method. Defects, as open, short, spots, et al, are distinguished by line type inspection algorithm. In experiment results, we could have ensured ability of inspection that can be detected with reliability of up to 95% in about 60 seconds

  • PDF

Three-dimensional monte carlo simulation and mask effect of low-energy boron ion implantation into <100>single-crystal silicon (<100>방향 실리콘 단결정에서의 저 에너지 붕소 이온 주입 공정에 대한 3차원 몬테 카를로 시뮬레이션 및 마스크 효과)

  • 손명식;이준하;송영진;황호정
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.8
    • /
    • pp.94-106
    • /
    • 1995
  • A three-dimensional(3D) Monte Carlo simulator for boron ion implantation into <100>single-crystal silicon considering the mask structure has been developed to predict the mask-dependent impurity doping profiles of the implanted boron at low energies into the reduced area according to the trend of a reduction in the size of semiconductor devices. All relevant important parameters during ion implantation have been taken into account in this simulator. These are incident energy, tilt and rotation of wafer, orientation of silicon wafer, presence of native silicon dioxide layer, dose, wafer temperature, ion beam divergence, masking thickness, and size and structure of open window in the mask. The one-dimensional(1D) results obtained by using the 3D simulator have been compared with the SIMS experiments to demonstrate its capabilities and confirem its reliability, and we obtained relatively accurate 1D doping profiles. Through these 3D simulations considering the hole structure and its size, we found the mask effects during boron ion implantation process.

  • PDF

Residual stress of cold-formed thick-walled steel rectangular hollow sections

  • Zhang, Xingzhao;Liu, Su;Zhao, Mingshan;Chiew, Sing-Ping
    • Steel and Composite Structures
    • /
    • v.22 no.4
    • /
    • pp.837-853
    • /
    • 2016
  • This paper presents the experimental and numerical study on the distribution of transverse and longitudinal residual stresses in cold-formed thick-walled structural steel rectangular hollow sections manufactured by indirect technique. Hole-drilling method is employed to measure the magnitude of the transverse and longitudinal surface residual stress distribution, and the effects of the residual stresses are evaluated qualitatively by sectioning method. It is shown that compared to normal cold-formed thin-walled structural hollow sections (SHS), the cold-formed thick-walled SHS has similar level of residual stress in the flat area but higher residual stresses in the corner and welding areas. Both the transverse and longitudinal residual stresses tend to open the section. In order to predict the surface residual stresses in the corners of the cold-formed thick-walled SHS, an analytical model is developed. 2D finite element simulation of the cold bending process is conducted to validate the analytical approach. It is shown that in analyzing bending for thick-walled sections, shifting of neutral axis must be considered, since it would lead to nonlinear and non-symmetrical distribution of stresses through the thickness. This phenomenon leads to the fact that cold-formed thick-walled SHSs has different distribution and magnitude of the residual stresses from the cold-formed thin-walled SHSs.

THE ANALYTIC ANALYSIS OF SUPPRESSING JET FLOW AT GUIDE TUBE OF CIRCULAR IRRADIATION HOLE IN HANARO (하나로 원형 조사공의 안내관 제트유동 억제에 대한 해석)

  • Park Y.C.;Wu S.I.
    • Journal of computational fluids engineering
    • /
    • v.10 no.2
    • /
    • pp.1-6
    • /
    • 2005
  • The HANARO, a multi-purpose research reactor of 30 MWth, open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. The HANARO is composed af inlet plenum, grid plate, core channel with flow tubes and chimney. The reactor core channel is located at about twelve meters (12 m) depth of the reactor pool and cooled by the upward flow that the coolant enters the lower inlet of the plenum, rises up through the grid plate and the core channel and comes out from the outlet of chimney. A fission moly guide tube is extended from the reactor core to the top of the reactor chimney for easily loading a fission moly target under the reactor normal operation. But active coolant through the core can be quickly raised up to the top of the chimney through the guide tube by jet flow. This paper describes an analytical analysis that is the study of the flow behavior through the guide tube under reactor normal operation and unloading the target. As results, it was conformed through the analysis results that the flow rate, reduced to about fourteen kilogram per second (14 kg/s) from the original flow rate of sixteen point three kilogram per second (16.3 kg/s) did not show the guide tube jet.