• 제목/요약/키워드: Open cycle

검색결과 401건 처리시간 0.028초

열린 홀을 가진 2사이클 엔진실더의 호닝가공시 호닝의 정밀도에 미치는 혼스톤의 영향 (Effect of Hone Stone on Accuracy of Honing in 2-Cycle Engine Cylinder having Open Hole)

  • 장명진
    • 한국생산제조학회지
    • /
    • 제9권3호
    • /
    • pp.143-149
    • /
    • 2000
  • Grinding technology in morden industry society is focusing on research and development for grinding stone and machin-ing parts for the purpose of high accuracy and high efficiency of products. But in order to equip the high technology and high accuracy of micro stone which is one of grinding stone a continuous effort on R& D is require. In this study the honing processing work of 2 cycle engine cylinder for motorcycle which has an open hole is carried out so as to investigate the boring and hone stone effects on accuracy of honing. As the experimental result of this study we could conclude that it is possible to secure good conditions of honing by controlling and keeping appropriate cycle-time in the stage of boring for the prior step of honing.

  • PDF

열린 홀을 가진 2사이클 엔진실린더의 호닝가공에서 혼스톤이 호닝의 정밀도에 미치는 영향 (Effect of Hone stone on Accuracy of Honing in 2-Cycle engine Cylinder having Open Hole)

  • 한규택
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.326-331
    • /
    • 1999
  • Grinding technology in morden industry society is focusing on research & development for grinding stone and machining parts for the purpose of high accuracy and high efficiency of products. But, in order to equip the high technology and high accuracy of micro stone which is one of grinding stone, hardly and continuous effort on R&D is required.In this study, honing processing work of 2-cycle engine cylinder for motorcycle which has open hole is practiced so as to clear how borning that is prior step of honing and hone stone make an influence on accuracy of honing. As the result of analyzing the results of experiments, we came to conclusion that we can secure good conditions of honing by controlling and keeping appropriate cycle-time in the stage of boring of prior step of honing.

  • PDF

담수화 공정과 이산화탄소 냉동 시스템의 복합사이클 해석 (Analysis of combined cycle for desalination process and $CO_2$ refrigeration system)

  • 신지영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권1호
    • /
    • pp.41-48
    • /
    • 2000
  • The characteristics of a combined cycle for the production of fresh water and air-conditioning was analyzed. The combined cycle consisted of an open water cycle and a $CO_2$ refrigeration cycle interlinked in the pre-heater of the water cycle, which is the condenser of the refrigeration cycle. The oprating conditions and criteria for the fresh water production and air-conditioning was described and their effects on the total system were evaluated. The results indicated an increase of desalinated water with the increase of hot water temperature, which resulted in the decrease of cooling capacity of the refrigeration system in this study. However, the energy saving correspond to the pre-heating of the water cycle by the condensing of the refrigeration system shows the avilable advantage of the proposed cycle as compared to other single purpose plants for desalination.

  • PDF

액화천연가스를 활용한 개방형 랭킨 사이클에 적용한 냉열 발전의 최적화에 대한 연구 (Optimization Study on the Open-Loop Rankine Cycle for Cold Heat Power Generation Using Liquefied Natural Gas)

  • 김영우;이중성;이종집;김동선;조정호
    • 한국수소및신에너지학회논문집
    • /
    • 제28권3호
    • /
    • pp.295-299
    • /
    • 2017
  • In this study, computer simulation and optimization works have been performed for an open-loop Rankine cycle to generate power using five cases of liquefied natural gas compositions. PRO/II with PROVISION V9.4 from Schneider electric company was used, and the Soave-Redlich-Kwong equation of the state model was utilized for the design of the power generation cycle. It was concluded that more power was obtained from less molecular weight liquefied natural gas since there was more volumetric flow rate with less molecular weight.

Design and Exergy Analysis for a Combined Cycle of Liquid/Solid $CO_2$ Production and Gas Turbine using LNG Cold/Hot Energy

  • Lee, Geun-Sik
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권1호
    • /
    • pp.34-45
    • /
    • 2007
  • In order to reduce the compression power and to use the overall energy contained in LNG effectively, a combined cycle is devised and simulated. The combined cycle is composed of two cycles; one is an open cycle of liquid/solid carbon dioxide production cycle utilizing LNG cold energy in $CO_2$ condenser and the other is a closed cycle gas turbine which supplies power to the $CO_2$ cycle, utilizes LNG cold energy for lowering the compressor inlet temperature, and uses the heating value of LNG at the burner. The power consumed for the $CO_2$ cycle is investigated in terms of a solid $CO_2$ production ratio. The present study shows that much reduction in both $CO_2$ compression power (only 35% of the power used in conventional dry ice production cycle) and $CO_2$ condenser pressure could be achieved by utilizing LNG cold energy and that high cycle efficiency (55.3% at maximum power condition) in the gas turbine could be accomplished with the adoption of compressor inlet cooling and regenerator. Exergy analysis shows that irreversibility in the combined cycle increases linearly as a solid $CO_2$ production ratio increases and most of the irreversibility occurs in the condenser and the heat exchanger for compressor inlet cooling. Hence, incoming LNG cold energy to the above components should be used more effectively.

BIM 기반 건축설계 품질검토를 위한 체크리스트 개발 연구 (Development of Check-list for BIM Based Architectural Design Quality Check)

  • 최중식;김인한
    • 한국CDE학회논문집
    • /
    • 제18권3호
    • /
    • pp.177-188
    • /
    • 2013
  • The construction industry consists of various and massive architectural information as an architectural process includes a variety of design stages with cooperation of many disciplines. Particularly, architectural information is generated and managed through the life cycle of a building, from conceptual design stage to the construction and maintenance. A Building Information Model (BIM) serves as a shared knowledge resource for information about a facility forming a reliable basis for decisions during its life-cycle from inception onward. BIM technology accomplished quantitative development being utilized in various disciplines. However, it is necessary to develop environment and requirement for qualitative improvement of BIM based project. Particularly, requirement is very important for architectural design evaluations. The purpose of this study is to develop and apply of quality control check-list for improving the quality of architectural design in BIM environments. To achieve this purpose, the authors have investigated case study for open BIM data quality control (software, guideline and application case) and classified quality control targets according to physical/logical quality control and data quality. In addition, the authors have defined open BIM based quality control process and developed quality control check-list. Finally, the authors have developed automatic quality check system using requirements for efficient quality control based on open BIM.

ETC 모드에서 Urea-SCR 시스템의 성능 특성 연구 (Study on the Performance Characteristics of Urea-SCR System in the ETC Test)

  • 함윤영;최동석;박용성
    • 한국자동차공학회논문집
    • /
    • 제18권2호
    • /
    • pp.122-128
    • /
    • 2010
  • To meet the NOx limit without a penalty of fuel consumption, urea-SCR system is currently regarded as promising NOx reduction technology for diesel engines. SCR system has to achieve maximal NOx conversion in combination with minimal $NH_3$ slip. In this study, the performance characteristics of urea-SCR system with open loop control were assessed in the European Transient Cycle(ETC) for heavy duty diesel engine. The SCR inlet temperaure varied in the range of 200 to $340^{\circ}C$ in the ETC cycle. Open loop control calculated the urea flow rate based on the NOx and NSR map which gave for each combination of SCR inlet temperature and space velocity the normalized $NH_3$ to NOx stoichiometric ratio which resulted in a steady-state $NH_3$ slip of 20ppm. During the ETC cycle, the open loop control with the optimized NSR offset achieved NOx reduction of 80% while keeping the average $NH_3$ slip below 10ppm and maximum 20ppm. It was also found that NOx sensor was cross-sensitive to $NH_3$ and a control strategy for cross-sensitivity compensation was required in order to use a NOx sensor as feedback device.

원자력발전소 온배수를 이용한 해양 온도차발전 사이클 해석 (Cycle Simulation on OTEC System using the Condenser Effluent from Nuclear Power Plant)

  • 김남진;전용한;김종보
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.37-44
    • /
    • 2007
  • For the past few years, the concern for clean energy has been greatly increased. Ocean Thermal Energy Conversion(OTEC) power plants are studied as a viable option for the supply of clean energy. In this paper, the thermodynamic performance of OTEC cycle was examined. Computer simulation programs were developed under the same condition and various working fluids for closed Rankine cycle, regeneration cycle, Kalina cycle, open cycle and hybrid cycle. The results show that the regeneration cycle using R125 showed a 0.17 to 1.56% increase in energy efficiency, and simple Rankine cycle can generate electricity when the difference in warm and cold sea water inlet temperatures are greater than $15^{\circ}C$. Also, the cycle efficiency of OTEC power plant using the condenser effluent from nuclear power plant instead of the surface water increased about 2%.

이산화탄소를 이용한 온수급탕용 초월임계사이클의 성능에 대한 실험적 연구 (Experimental Studies on the Performance of a Transcritical Cycle for Hot Water Heating Using Carbon Dioxide)

  • 김성구;김민수
    • 설비공학논문집
    • /
    • 제15권6호
    • /
    • pp.461-470
    • /
    • 2003
  • The purpose of this study is to investigate the performance of a transcritical cycle for hot water heating using $CO_2$ as a working fluid. Some of the main parameters that affect the practical performance of the $CO_2$ system are discussed; the performance on the variation of refrigerant charge, changes in flow conditions of secondary fluids, and that with or without internal heat exchanger, The experimental results show that the optimum charge is approximately the same for various mass flow rates of the secondary fluid at gas cooler. The experimental results on the effect of secondary fluids are in general agreement with the experimental results of transcritical cycle in the open literature and show similar trend for conventional subcritical vapor compression cycles. The heat exchanger effectiveness increases with an increase of the heat exchange area of the internal heat exchanger regardless of the mass flow rate at the gas cooler.

Half Load-Cycle Worked Dual Input Single Output DC/AC Inverter

  • Chen, Rong;Zhang, Jia-Sheng
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1217-1223
    • /
    • 2014
  • A novel half load-cycle worked dual input single output (DISO) DC/AC inverter is presented. The basic circuit consists of a dual buck regulator, which works in continuous current mode. The working principle of DISO DC/AC inverter has been used. The control method applied for half load-cycle worked DISO DC/AC inverter has been studied. The control effects of the open-loop proportional control and closed-loop proportional-integral control are compared by using PSIM software. The parameters are adopted in the realistic simulation and experiment test. Moreover, the waveforms, such as voltage of modulation reference signal and output voltage, were given. The simulation and experiment results proved that the half load-cycle worked DISO DC/AC inverter could achieve good performance, gain a line frequency of 50 Hz, and verify the correctness of theoretical analysis.