• 제목/요약/키워드: Opc

검색결과 974건 처리시간 0.028초

Screening and Cloning of RAPD Markers from the W Chromosome of Silkworm, Bombyx mori L.

  • Chen, Keping;Zhang, Chunxia;Yao, Qin;Xu, Qinggang;Tang, Xudong
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제8권2호
    • /
    • pp.161-167
    • /
    • 2004
  • Silkworms sex determination drew high attention from researchers. Sex chromosomes on the silkworm are of ZW type for females and ZZ type for males. Chromosome W plays an important role in sex determination. Although several molecular linkage maps have been constructed for silkworm, very few markers are discovered on the W chromosome. In order to look for molecular markers and to further locate the Fern gene on chromosome W, we used genomic DNA from both female and male larvae of a silkworm strain named 937 as PCR templates for RAPD amplification with 200 arbitrary 10-mer primers. The amplification results showed three female-specific bands, namely ${OPG-07_496}, {OPC-15_1,660} and {OPE-18_1,279}$. Further verification, however, revealed no band from OPG-07 and OPC-15 in either sex in the strain 798, but OPE-18 provided female-specific band in the strains Suluan7 and C108, and absent in both males and strain 798. This indicates that the bands from ${OPG-07_496} and {OPC-15_1,660}$ are probably female-specific in strain 937, and the band from OPE-18 was probably amplified from a common segment shared by most strains. The genomic DNAs from OPG-07 and OPC-15 were cloned and sequenced. Sequence analysis showed that the DNAs from OPG-07 and OPC-15 have high identities with the retrotransposable elements, and DNA from OPC-15 contains a portion of sequence which probably encodes an eukaryotic translation initiation factor 4E binding protein (eIF4EBP).

비영 분산 천이 광섬유를 갖는 WDM시스템에서 광 위상 공액기의 최적 파라미터를 이용한 비트 에러율 개선 (Improvement of Bit Error Rate using the Optimal Parameters of Optical Phase Conjugator in WDM System with Non Zero - Dispersion Shifted Fiber)

  • 이성렬
    • 한국정보통신학회논문지
    • /
    • 제10권10호
    • /
    • pp.1854-1862
    • /
    • 2006
  • 본 논문에서는 광 전송로로 비영 분산천이 광섬유 (NZ-DSF ; Non Zero - Dispersion Shifted Fiber)를 이용한 $8{\times}40Gbps$ WDM 시스템에서 모든 채널을 효과적으로 보상할 수 있는 광 위상 공액기 (OPC ; Optical Phase Conjugator)의 최적 위치와 광섬유의 최적 분산 계수 값을 도출하는 수치적 방법을 제안하였다. 이 방법의 유용성을 확인하기 위하여 도출된 두 최적 파라미터를 갖는 시스템에서의 비트 에러율 (BER ; Bit Error Rate) 특성 을 현재 일반화된 MSSI(Mid-Span Spectral Inversion)에서 의 BER 특성과 비교하였다. 최적 파라미터들을 갖는 OPC를 WDM 시스템에 적용하게 되면 채널 간 파워 패널티를 4배 이상으로 감소시킬 수 있다는 것을 알 수 있었다. 따라서 본 논문에서 제안한 방법은 WDM시스템에 OPC를 적용하고자 할 때 전제가 되어야 하지만 실제 광 전송 링크에서 구현하기 어려운 OPC를 중심으로 한 광 신호 전력과 총 분산 값의 대칭 문제를 해결해야 하는 방법을 대체할 것으로 예상된다.

알칼리활성 플라이 애쉬 시멘트-콘크리트의 산저항성 및 내구성 (Acid Corrosion Resistance and Durability of Alkali-Activated Fly Ash Cement-Concrete)

  • 강화영;박상숙;한상호
    • 대한환경공학회지
    • /
    • 제30권1호
    • /
    • pp.61-68
    • /
    • 2008
  • 알칼리활성 플라이 애쉬 시멘트(AAFC)라 불리는 새로운 시멘트 물질을 이용하여 AAFC-콘크리트를 제조하였다. 알칼리활성 플라이 애쉬 시멘트를 사용하여 제조한 AAFC-콘크리트와 OPC-콘크리트에 대하여 산 침투, 염분, 탄산화, 동결 융해에 대한 영향과 SEM, XRD 분석을 수행하였다. 플라이 애쉬를 85$^{\circ}C$에서 24시간 동안 알칼리 활성화하여 제조한 AAFC-콘크리트(35 MPa)의 산 저항성은 OPC-콘크리트(35 MPa)보다 훨씬 뛰어난 것으로 나타났다. 또한 AAFC-콘크리트(35 MPa)는 염분용액, 탄산화 그리고 동결-융해와 같은 공격에 OPC-콘크리트(35 MPa)와 비슷한 저항성을 가지고 있는 것으로 나타났다.

스마트 그리드 기반 통합 SCADA Data Gateway 플랫폼 (The Integrated SCADA Data Gateway Platform based on SmartGrid)

  • 송병권
    • 전기전자학회논문지
    • /
    • 제18권1호
    • /
    • pp.140-145
    • /
    • 2014
  • OPC UA(IEC62541)는 SG(Smart Grid) 응용 플랫폼 간에 연계 프로토콜로서, 2012년 12월에 IEC TC57 그룹에서 IEC62541로 표준화되었다. IEC61850은 디지털 변전소 및 스마트 배전 시스템에서 사용되는 SCADA 표준 프로토콜이고, DNP3.0은 RTU나 IED와 같은 장비에 대해 데이터 수집 제어를 위한 프로토콜로서 기존 배전 자동화 시스템에서 사용되고 있다. DLMS/COSEM은 전기 계량기를 제어하고 정보를 수집하기 위한 프로토콜로서 스마트 계량기에서 사용되고 있다. 최상위 SG 운영 플랫폼에서 IEC61850 이나 DNP3.0을 비롯한 다양한 전력 IT 시스템들을 투명하게(Transparent) 관리하기 위해서는 프로토콜에 독립적인 미들웨어가 필요하다. 본 논문은 IEC61850, DNP3.0, DLMS/COSEM 기반의 디지털변전소, 스마트 배전시스템 및 기존 배전 자동화 시스템을 단일 OPC UA 클라이언트로 통합 관리하기 위한 SDG(Scada Data Gateway) 플랫폼에 관한 것이다. 이 게이트웨이는 OPC UA를 통해서 스마트미터, 디지털변전소 및 스마트배전 시스템을 관리한다.

인위적인 단일 모드 광섬유 길이와 RDPS 분포를 갖는 분산 제어 광전송 링크에서 선치 보상과 후치 보상을 통한 WDM 신호의 성능 개선 (Performance Improvement of WDM Signals through Precompensation and Postcompensation in Dispersion Managed Optical Transmission Links with Artificial Distribution of Single Mode Fiber Length and RDPS)

  • 이성렬
    • 한국정보통신학회논문지
    • /
    • 제16권10호
    • /
    • pp.2293-2302
    • /
    • 2012
  • 단일 모드 광섬유의 그룹 속도 분산과 자기 위상 변조에 의해 왜곡된 파장 분할 다중 신호의 효율적인 보상을 위한 새로운 광전송 링크 기술을 제안하였다. 제안된 전송 링크는 WDM 송신이나 수신단 근처에 광 위상 공액기(OPC; optical phase conjugator)가 위치하고 각 중계 구간의 SMF 길이와 RDPS(residual dispersion per span)가 인위적으로 분포하는 구조이다. 시스템 성능을 개선하여 유효 입사 전력 범위와 유효 전체 잉여 분산 (NRD; net residual dispersion)을 늘릴 수 있는 최적의 링크 구조는 OPC가 WDM 수신단에 가깝게 위치하고 후치 보상(postcompensation)에 의해 NRD를 결정하고 중계 구간이 증가할수록 SMF 길이와 RDPS를 점진적으로 감소시키는 링크라는 것을 확인하였다.

Analysis of Process Parameters to Improve On-Chip Linewidth Variation

  • Jang, Yun-Kyeong;Lee, Doo-Youl;Lee, Sung-Woo;Lee, Eun-Mi;Choi, Soo-Han;Kang, Yool;Yeo, Gi-Sung;Woo, Sang-Gyun;Cho, Han-Ku;Park, Jong-Rak
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제4권2호
    • /
    • pp.100-105
    • /
    • 2004
  • The influencing factors on the OPC (optical proximity correction) results are quantitatively analyzed using OPCed L/S patterns. ${\sigma}$ values of proximity variations are measured to be 9.3 nm and 15.2 nm for PR-A and PR-B, respectively. The effect of post exposure bake condition is assessed. 16.2 nm and 13.8 nm of variations are observed. Proximity variations of 11.6 nm and 15.2 nm are measured by changing the illumination condition. In order not to seriously deteriorate the OPC, these factors should be fixed after the OPC rules are extracted. Proximity variations of 11.4, 13.9, and 15.2 nm are observed for the mask mean-to-targets of 0, 2 and 4 nm, respectively. The decrease the OPC grid size from 1 nm to 0.5 nm enhances the correction resolution and the OCV is reduced from 14.6 nm to 11.4 nm. The enhancement amount of proximity variations are 9.2 nm corresponding to 39% improvement. The critical dimension (CD) uniformity improvement for adopting the small grid size is confirmed by measuring the CD uniformity on real SRAM pattern. CD uniformities are measured 9.9 nm and 8.7 nm for grid size of 1 nm and 0.5 nm, respectively. 22% improvement of the CD uniformity is achieved. The decrease of OPC grid size is shown to improve not only the proximity correction, but also the uniformity.

조분시멘트와 플라이애시를 조합 사용한 콘크리트의 수화발열 특성 (Generation of Hydration Heat of the Concrete Combined Coarse Particle cement and Fly ash)

  • 이충섭;백대현;차완호;권오봉;한민철;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.889-892
    • /
    • 2008
  • 본 연구는 보통포틀랜드 시멘트(이하 OPC)의 제조공정 중 입도 분급에 의해 포집된 조분시멘트(이하 CC)와 저발열 혼화재료인 플라이애시(이하 FA)를 조합 치환하여 콘크리트에 미치는 수화발열특성에 대해 검토하고자 하였다. 실험은 W/B 50% 1수준에 대하여 OPC를 100% 사용한 것을 Plain 배합으로 하고, CC를 OPC에 대하여 25, 50, 75%의 3수준으로 치환하고, 혼화재로 FA를 0, 10, 20, 30, 40%의 5수준으로 치환하여 총 16배치를 계획 하였다. 실험결과로 유동성의 경우는 CC 치환율이 증가할수록 점점 감소하는 경향을 나타냈고, FA의 치환율이 증가할수록 증가하였다. CC 및 FA 치환율 별간이단열에 의한 온도 상승량은 치환율이 증가할수록 감소하였는데, 특히 FA40의 경우 CC치환율에 관계없이 최대 피크온도가 $7.3{\sim}8.9^{\circ}C$로 45%정도 아주 낮게 나타났다. 초기 압축강도는 CC 및 FA치환율 증가에 따라 비례적으로 저하하였는데, 재령경과에 따라 강도저하 폭은 감소하는 것으로 나타났다.

  • PDF

고로슬래그 미분말과 순환잔골재를 사용하는 친환경 모르타르에 탈황석고 및 시멘트에 의한 품질향상 (Improving Quality of Eco-Mortar Incorporating Blast Furnace Slag and Recycled Aggregate Depending on Replacement Gypsum and Cement)

  • 백병훈;한천구
    • 한국건축시공학회지
    • /
    • 제15권2호
    • /
    • pp.193-199
    • /
    • 2015
  • 최근, 콘크리트 산업에서는 $CO_2$ 배출량감소등 환경문제와 함께 부존자원의 고갈대책도 중요한 문제점으로 제기되어, 이를 동시에 해결하기 위하여 각종 산업부산물이나 산업폐기물을 콘크리트용 자원으로 재이용하는 방법이 연구되고 있다. 본 연구는 고로슬래그 미분말(BS)과 순환잔골재(RFA) 혼합 모르타르를 기반으로 하여 BS의 잠재수경성 반응을 탈황석고(FGD)와 보통포틀랜드 시멘트(OPC)의 자극반응으로 추가 활성화시킴으로써 일반 강도영역까지의 모르타르 활용성을 검토하고자 하였다. 결과적으로, BS에 FGD 10%, OPC 30%를 치환하고 RFA를 사용할 경우 OPC만을 사용하는 플레인 모르타르의 80%정도인 보통강도모르타르가 발휘되었지만 실용적인 측면에서 유동성적으로 플로치를 동일하게 유지하는 물-결합재를 낮춰 주게 된다면 더욱 플레인 강도영역에 근접할 수 있을 것으로 사료된다.

순환 유동층 보일러 애시의 촉진탄산화에 의한 탄소포집 특성 (Characteristics of Carbon Capture by the Accelerated Carbonation Method of Circulating Fluidized Bed Combustion Ash)

  • 최영철;유성원
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권5호
    • /
    • pp.165-172
    • /
    • 2021
  • 이 연구는 건설재료로 활용 가능성이 높은 다양한 무기계 재료의 탄소포집에 대한 성능 평가를 목적으로 한다. 이러한 목적을 위해 광물탄산화가 가능한 보통포틀랜드 시멘트(OPC), 고로슬래그 미분말(GGBS), 순환유동층 보일러 애시(CFBC)의 탄산화 반응에 대한 특성 변화를 분석하였다. 촉진 탄산화 실험을 통해 모든 재료에 대한 탄산화 양생을 수행하였으며, 탄산화 재령에 따라 열중량 분석에 의해 탄소포집량을 정량분석하였다. 모든 재료에서 탄소포집 효과가 확인되었고, 실험결과 탄소포집량은 CFBC, OPC, GGBS 순으로 나타났다. CFBC, OPC, GGBS의 28일 탄소포집량은 각각 9.4 wt.%, 3.9 wt.%, wt.1.3 %이다. 탄소포집은 탄산화 초기에 빠르게 발생하였으며, 재령이 증가함에 따라 느리게 발생하였다. SEM 이미지 분석을 통해, 모든 실험체에서 탄산화 양생에 의해 발생된 추가적인 생성물은 탄산칼슘(CaCO3)으로 나타났다.

시험환경 내 입자수에 대한 OPC, CNC 장비 간 마스크 밀착 성능비교 (Fit Performance Comparison Between OPC and CNC Based on Number of Ambient Aerosol Particles)

  • 서혜경;장호영;심수아;김희주;한돈희
    • 한국산업보건학회지
    • /
    • 제32권2호
    • /
    • pp.163-171
    • /
    • 2022
  • Objectives: Fit performance may vary depending on the ambient aerosol number and ratio in respective test environment. Although several instrument can measure it, they differ with respect to the measurement principle and the range of ambient aerosols collected to calculate the fit factor. Methods: In this study, the fit performance between a condensation nuclei counter(CNC) and an optical particle counter(OPC) was compared according to ambient aerosol number concentration, and evaluated consistency. One type respirators(N95 masks) was worn by 50 participants PortaCount®(Pro+ 8038) and MT®(05U) were connected with one probe to one mask, and Fit Factors(FFs) were measured simultaneously. Results: The interclass correlation coefficient of the fit factor and ambient aerosol number, as measured by the two instrument, was 0.82 and 0.79, respectively, indicating a high consistency level. On the other hand there was a significant correlation between the successful test performance of the OPC instrument and the ambient aerosol number. Conclusions: The test was passed with the CNC and OPC instruments when the ambient aerosol number was 635-3,332 particles/cm3 and 368-1,976 particles/cm3, respectively. Thus, the ideal ambient aerosol number of particles differed between the two instrument.