• Title/Summary/Keyword: Opc

Search Result 970, Processing Time 0.02 seconds

Screening and Cloning of RAPD Markers from the W Chromosome of Silkworm, Bombyx mori L.

  • Chen, Keping;Zhang, Chunxia;Yao, Qin;Xu, Qinggang;Tang, Xudong
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.8 no.2
    • /
    • pp.161-167
    • /
    • 2004
  • Silkworms sex determination drew high attention from researchers. Sex chromosomes on the silkworm are of ZW type for females and ZZ type for males. Chromosome W plays an important role in sex determination. Although several molecular linkage maps have been constructed for silkworm, very few markers are discovered on the W chromosome. In order to look for molecular markers and to further locate the Fern gene on chromosome W, we used genomic DNA from both female and male larvae of a silkworm strain named 937 as PCR templates for RAPD amplification with 200 arbitrary 10-mer primers. The amplification results showed three female-specific bands, namely ${OPG-07_496}, {OPC-15_1,660} and {OPE-18_1,279}$. Further verification, however, revealed no band from OPG-07 and OPC-15 in either sex in the strain 798, but OPE-18 provided female-specific band in the strains Suluan7 and C108, and absent in both males and strain 798. This indicates that the bands from ${OPG-07_496} and {OPC-15_1,660}$ are probably female-specific in strain 937, and the band from OPE-18 was probably amplified from a common segment shared by most strains. The genomic DNAs from OPG-07 and OPC-15 were cloned and sequenced. Sequence analysis showed that the DNAs from OPG-07 and OPC-15 have high identities with the retrotransposable elements, and DNA from OPC-15 contains a portion of sequence which probably encodes an eukaryotic translation initiation factor 4E binding protein (eIF4EBP).

Improvement of Bit Error Rate using the Optimal Parameters of Optical Phase Conjugator in WDM System with Non Zero - Dispersion Shifted Fiber (비영 분산 천이 광섬유를 갖는 WDM시스템에서 광 위상 공액기의 최적 파라미터를 이용한 비트 에러율 개선)

  • Lee, Seong-Real
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.10
    • /
    • pp.1854-1862
    • /
    • 2006
  • The numerical methods of finding out the optimal position of optical phase conjugator (OPC) and the optimal fiber dispersions are prosed, which are able to effectively compensate overall channels in $8{\times}40Gbps$Gbps WDM system with non zero - dispersion shifted fiber (NZ-DSF) as an optical fiber. And BER characteristics in the system with two induced optimal parameters are compared with those in the system with the currently used mid-span spectral inversion (MSSI) in order to confirm the availability of the proposed methods. It is confirmed that the applying two induced optimal parameters into WDM system contribute to reduce power penalty to 4 times than that of WDM system with the conventional MSSI. Thus, the methods proposed in this research will be expected to alternate with the method of making a symmetrical distribution of power and local dispersion in real optical link which generates a serious problem if it was not made but it is the condition in the case of applying the OPC into multi-channels WDM system.

Acid Corrosion Resistance and Durability of Alkali-Activated Fly Ash Cement-Concrete (알칼리활성 플라이 애쉬 시멘트-콘크리트의 산저항성 및 내구성)

  • Kang, Hwa-Young;Park, Sang-Sook;Han, Sang-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.1
    • /
    • pp.61-68
    • /
    • 2008
  • A new cementitious material has been developed, called alkali-activated fly ash cement(AAFC), which is used to produce AAFC-concrete for construction. The effect of acid attack, sodium chloride solution, carbonation, freeze-thaw cycling, and SEM, XRD analysis of the AAFC-concrete prepared using alkali-activated fly ash cement and OPC-concrete were experimentally investigated. It was found that the acid resistance of AAFC-concrete(35 MPa) prepared from alkali-activated fly ash at 85$^{\circ}C$ for 24 hrs is far better than OPC-concrete(35 MPa). Also, the AAFC-concrete(35 MPa) had a similar resistance of OPC-concrete(35 MPa) to attack, such as sodium chloride solution, carbonation and freeze-thaw cycling.

The Integrated SCADA Data Gateway Platform based on SmartGrid (스마트 그리드 기반 통합 SCADA Data Gateway 플랫폼)

  • Song, Byung-Kwen
    • Journal of IKEEE
    • /
    • v.18 no.1
    • /
    • pp.140-145
    • /
    • 2014
  • OPC UA(IEC62541) is a communication protocol for SG(Smart Grid) application platform. It was standardized by IEC TC57 group in December 2012. The IEC61850 has been used in Digital Substation Systems and Smart Distributed Systems. The DNP3.0 has been used for device's data collection/control in Distributed Systems. The DLMS/COSEM has been used to control metering and collect information in the Smart Metering. The top-level SG management platform needs an independent middleware to manage transparently the Power Information Technology, including the IEC61850, DNP3.0, DLMS/COSEM. In this paper, we propose the SDG(Scada Data Gateway) platform. It manages Power Information Technology based Digital Substation Systems and Smart Distributed systems, Smart Metering through OPC UA.

Performance Improvement of WDM Signals through Precompensation and Postcompensation in Dispersion Managed Optical Transmission Links with Artificial Distribution of Single Mode Fiber Length and RDPS (인위적인 단일 모드 광섬유 길이와 RDPS 분포를 갖는 분산 제어 광전송 링크에서 선치 보상과 후치 보상을 통한 WDM 신호의 성능 개선)

  • Lee, Seong-Real
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.10
    • /
    • pp.2293-2302
    • /
    • 2012
  • New optical transmission links technique for compensating of the distorted wavelength division multiplexed (WDM) signals due to group velocity dispersion (GVD) and self phase modulation (SPM) in single mode fiber (SMF) are proposed. The proposed optical links have optical phase conjugator (OPC) placed at nearby WDM transmitter or receiver and repeater spans with artificial distribution of SMF length and residual dispersion per span (RDPS). It is confirmed that optimal link configuration expanding effective launching power range and effective net residual dispersion (NRD) by improving system performance is that having OPC closely placed at WDM receiver and the gradually descended distribution of SMF length and RDPS of each repeater spans, related with the gradually increased optical link length. And, it is also confirmed that NRD is controlled by postcompensation in optimal optical link with OPC closely placed at WDM receiver.

Analysis of Process Parameters to Improve On-Chip Linewidth Variation

  • Jang, Yun-Kyeong;Lee, Doo-Youl;Lee, Sung-Woo;Lee, Eun-Mi;Choi, Soo-Han;Kang, Yool;Yeo, Gi-Sung;Woo, Sang-Gyun;Cho, Han-Ku;Park, Jong-Rak
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.4 no.2
    • /
    • pp.100-105
    • /
    • 2004
  • The influencing factors on the OPC (optical proximity correction) results are quantitatively analyzed using OPCed L/S patterns. ${\sigma}$ values of proximity variations are measured to be 9.3 nm and 15.2 nm for PR-A and PR-B, respectively. The effect of post exposure bake condition is assessed. 16.2 nm and 13.8 nm of variations are observed. Proximity variations of 11.6 nm and 15.2 nm are measured by changing the illumination condition. In order not to seriously deteriorate the OPC, these factors should be fixed after the OPC rules are extracted. Proximity variations of 11.4, 13.9, and 15.2 nm are observed for the mask mean-to-targets of 0, 2 and 4 nm, respectively. The decrease the OPC grid size from 1 nm to 0.5 nm enhances the correction resolution and the OCV is reduced from 14.6 nm to 11.4 nm. The enhancement amount of proximity variations are 9.2 nm corresponding to 39% improvement. The critical dimension (CD) uniformity improvement for adopting the small grid size is confirmed by measuring the CD uniformity on real SRAM pattern. CD uniformities are measured 9.9 nm and 8.7 nm for grid size of 1 nm and 0.5 nm, respectively. 22% improvement of the CD uniformity is achieved. The decrease of OPC grid size is shown to improve not only the proximity correction, but also the uniformity.

Generation of Hydration Heat of the Concrete Combined Coarse Particle cement and Fly ash (조분시멘트와 플라이애시를 조합 사용한 콘크리트의 수화발열 특성)

  • Lee, Chung-Sub;Baek, Dae-Hyun;Cha, Wan-Ho;Kwon, O-Bong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.889-892
    • /
    • 2008
  • This study, having combined and displaced fly ash known as admixture material that delays hydration reaction with coarse particle cement("CC" hereinafter) collected in particle classification method during ordinary portland cement("OPC" hereinafter), reviewed the hydration heat characteristics affecting the concrete. To reduce hydration heat, the study plain-mixed which used 100% OPC for WB 50% level 1, displaced CC at level 3 of 25%, 50% and 75% for OPC, and by displacing FA with admixture material at level 5 of 0%, 10%, 20%, 30% and 40%, experimented totally 16 batches. As a result of experiment, in the case of flow, the more CC displacement rate increased, the more it tended to decrease, and the more FA displacement rate increased, the more it decreased. As for simple adiabatic temperature rise by the CC and FA displacement rates, it decreased as displacement rate increased, and particularly in the case of FA40, temperature rise amount, $5.8{\sim}7.4^{\circ}C$, was very low. Compressive strength decreased in proportion to displacement rate, however strength reduction increment was shown to decrease with age progress.

  • PDF

Improving Quality of Eco-Mortar Incorporating Blast Furnace Slag and Recycled Aggregate Depending on Replacement Gypsum and Cement (고로슬래그 미분말과 순환잔골재를 사용하는 친환경 모르타르에 탈황석고 및 시멘트에 의한 품질향상)

  • Baek, Byung Hoon;Han, Cheon-Goo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.2
    • /
    • pp.193-199
    • /
    • 2015
  • As a solution of both environmental issue of reducing carbon dioxide emission and sustainable issue of exhausting natural resources, in concrete industry, many research on recycling various by-products or industrial wastes as the concrete materials has been conducted. The aim of this research is feasibility analysis of additional reaction with ordinary Portland cement and flue gas desulfurization gypsum based on the blast furnace slag and recycled fine aggregate based mortar to achieve the normal strength range. Consequently, in the case of mortar replaced 10% FGD and 30% OPC for BS, 80% of plain OPC mortar's compressive strength was achieved. Furthermore, when the water-to-binder ratio is decreased to keep the practically similar level of flow, it is expected to be achieve the equivalent compressive strength to plain OPC mortar.

Characteristics of Carbon Capture by the Accelerated Carbonation Method of Circulating Fluidized Bed Combustion Ash (순환 유동층 보일러 애시의 촉진탄산화에 의한 탄소포집 특성)

  • Choi, Young-Cheol;Yoo, Sung-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.165-172
    • /
    • 2021
  • The purpose of this study is to investigate the carbon capture capacity of various inorganic materials. For this purpose, the change in property of ordinary Portland cement (OPC), blast furnace slag fine powder (GGBS), and circulating fluidized bed boiler ash (CFBC) due to carbonation were analyzed. Carbonation curing was performed on all specimens through the accelerated carbonation experiment, and the amount of carbon capture was quantitatively analyzed by thermogravimetric analysis according to the age of carbonation. From the results, it is confirmed that the carbon capture capacity was shown in all specimens. The carbon capture amount was shown in the order of CFBC, OPC, and GGBS. The 28-day carbon capture of CFBC, OPC, and GGBS was 3.9%, 1.3%, and 9.4%, respectively. Carbon capture reaction occurred rapidly at the beginning of carbonation, and occurred slowly with increasing age. SEM image analysis revealed that an additional product generated by carbonation curing in all specimens was calcium carbonate.

Fit Performance Comparison Between OPC and CNC Based on Number of Ambient Aerosol Particles (시험환경 내 입자수에 대한 OPC, CNC 장비 간 마스크 밀착 성능비교)

  • Seo, Hyekyung;Jang, Hoyeong;Shim, Sua;Kim, Huiju;Han, Donhee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.2
    • /
    • pp.163-171
    • /
    • 2022
  • Objectives: Fit performance may vary depending on the ambient aerosol number and ratio in respective test environment. Although several instrument can measure it, they differ with respect to the measurement principle and the range of ambient aerosols collected to calculate the fit factor. Methods: In this study, the fit performance between a condensation nuclei counter(CNC) and an optical particle counter(OPC) was compared according to ambient aerosol number concentration, and evaluated consistency. One type respirators(N95 masks) was worn by 50 participants PortaCount®(Pro+ 8038) and MT®(05U) were connected with one probe to one mask, and Fit Factors(FFs) were measured simultaneously. Results: The interclass correlation coefficient of the fit factor and ambient aerosol number, as measured by the two instrument, was 0.82 and 0.79, respectively, indicating a high consistency level. On the other hand there was a significant correlation between the successful test performance of the OPC instrument and the ambient aerosol number. Conclusions: The test was passed with the CNC and OPC instruments when the ambient aerosol number was 635-3,332 particles/cm3 and 368-1,976 particles/cm3, respectively. Thus, the ideal ambient aerosol number of particles differed between the two instrument.