• 제목/요약/키워드: One-cycle control

검색결과 512건 처리시간 0.033초

Comparison Analysis of Behavior between Differential Equation and Fractional Differential Equation in the Van der Pol Equation (Van der Pol 발진기에서의 미분방정식과 Fractional 미분방정식의 거동 비교 해석)

  • Bae, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • 제11권1호
    • /
    • pp.81-86
    • /
    • 2016
  • Three hundred years ago, the fractional differential equation that is one of concept of fractional calculus released. Now, many researchers continue to try best effort applying into the control engineering, mathematics and physics. In this paper, the dynamics equation which is represented by Van der Pol, represent integer order and fractional order that having real order. Then this paper performs the comparisons between integer and real order as time series and phase portrait according to variation of parameter value for real order.

Performance Characteristics of the Desiccant Cooling System in Various Outdoor and Load Conditions (외기조건에 따른 제습냉방시스템의 성능 특성)

  • Lee, Dae-Young;Chang, Young-Soo
    • Proceedings of the SAREK Conference
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.623-628
    • /
    • 2009
  • Desiccant based air conditioning system offers a promising alternative to conventional one using vapour compression refrigeration for energy saving and greenhouse gas reduction. It is a heat driven cycle which has high potential for the use of low grade heat source such as the waste heat from the cogeneration plant or the solar thermal energy. In this study, the cooling performance of a desiccant cooling system incorporating a regenerative evaporative cooler was characterized in various operation conditions through numerical simulation. The cooling capacity and COP were evaluated at various outdoor conditions, regeneration temperatures, and supply flow rates. Based on the performance characteristics, the optimal control scheme was discussed to minimize the cooling cost at part load condition.

  • PDF

A Study on Marital Conflict of Wives in Rural Areas (도시근교 농촌주부의 부부갈등에 관한 연구)

  • 김영희;한경혜
    • Korean Journal of Rural Living Science
    • /
    • 제7권2호
    • /
    • pp.129-138
    • /
    • 1996
  • This study attempted to explore the characteristics of conflicts in marriage life, and to analyze their impacts on global marital satisfaction perceived by wives in rural areas. The survey data was gathered from 151 rural wives. The degrees of three types of conflicts were shown to be low. while in terms of the degree of seriousness, environmental, interpersonal and intrapersonal are in descending order. Especially the degree of the environmental types of conflicts were significantly different across the family life cycle. In order to analyze the relationships between the types of conflicts and the marital satisfaction, logistic regression were performed. It was found that the environmental type of conflict was negatively associated with the likelihood of satisfaction in the marriage life. On the other hand, one of the control variables, the degree of satisfaction on the husband's job, i.e., farming, was positively associated with it.

  • PDF

A Study on Flow Balance and Cavity Pressure in Family Mold (FAMILY MOLD의 유동 밸런스와 금형 내압에 관한 연구)

  • 김태철;이대근;홍기복;김영근;박인수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.603-607
    • /
    • 2002
  • Cavity pressure is a factor of what is occurring inside the mold and is used as one of the process parameters that control the overall injection molding cycle. The insight of cavity pressure is able to predict part quality and optimum process condition. In this paper, it is adapted ejector pin sensor to measure the cavity pressure and investigates the flow balance and the cavity pressure according to different runner thickness for adjusting the flow balance. Flow balance is very important to have not the poor results such as flash and warpage in the family mold. This paper predicted flow balance and cavity pressure using CAE analysis tool and compared with the test results. The results of analysis and test have a good agreement with the cavity pressure profile and flow pattern of the test.

  • PDF

Designing an Inventory Model of Parallel-Type Distribution System

  • Kwon, Hee Chul;Kim, Man Shik
    • Journal of Korean Society for Quality Management
    • /
    • 제17권1호
    • /
    • pp.11-18
    • /
    • 1989
  • A one-upper level warehouse n-Iower level retailer inventory distribution model is discussed. This paper presents the parallel-type inventory structure using an order-up-to-level invertory control system for analyzing the approximation of the expected units back ordered and the measure of service. We find that the total expected backorder units in system can substitute the expected back orders in the last two periods for the expected back orders in total periods. The rate of total expected back orders which is the measure of disservice, is given by dividing the improved units of total expected backorder into the total demand during an order cycle. The average annual total cost in system is obtained by considering the results, but from the viewpoint of this study the cost analysis is not described.

  • PDF

A Study on Improvement Method of the Subway Signalling System Using Automatic Train Operation Device (자동열차운전장치를 이용한 도시철도 신호설비의 개량방안에 관한 연구)

  • Kang Sung-Gu;Choi Seung-Ho;Cho Bong-Kwan
    • Proceedings of the KSR Conference
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.145-150
    • /
    • 2003
  • The national subway went under construction in 1971, and after three years of endeavor, Seoul subway line number one opened for traffic in 1974. Line number two went under construction in 1978 and it opened for traffic in 1984. With the use of safety operation for more than 20 years, the life cycle nearly came to an end. Therefore the improvements for the safety operation are unavoidable. The total system should not be affected when the new and conventional systems are overlapped, the system operation is in the initial stage, and it confronts the situation of abnormal operation. However, there is a total lack of experience in construction and improvement for the trains that are in the use of large transport and density headway. In this paper, we propose an improvement method of the subway signalling system using ATO (Automatic Train Operation control scheme) to which the latest Digital ATC is applied, and examine the first application model of ATO system.

  • PDF

BIR Containing Proteins (BIRPs): More Than Just Cell Death Inhibitors

  • Yoo, Soon-Ji
    • Animal cells and systems
    • /
    • 제9권4호
    • /
    • pp.181-190
    • /
    • 2005
  • BIRPs (BIR containing Proteins) which contain one to three BIR domains constitute a highly conserved family from yeast to human. BIR domains mediate the interaction of BIRPs with various other proteins. Some of the members acquire a Ring domain which acts as an E3 ubiquitin ligase. The first member of BIRPs identified in the baculovirus was found as an inhibitor of apoptosis and most of the family members in the other species have been recognized to have the same function which bind to and inhibit caspases, thereby suppresses apoptotic cell death. But an increasing number of evidences indicate that BIRPs are involved in various cellular events such as cell division, control of cell cycle, signal transduction, cell migration, innate immunity as well as regulation of apoptosis. In this review, we summarize the structural and functional features of the BIRPs, especially focus on the various functions of BIRPs unrelated to regulation of apoptosis by the recent findings.

An Improvement of PWM Method for Single Phase Current Source Type Active Power Filter (단상 전류원형 능동전력필터를 위한 펄스폭 변조법의 개선)

  • 박인규;박종근
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • 제39권3호
    • /
    • pp.254-262
    • /
    • 1990
  • In the active power filter, the PWM method for controlling the power converter plays an important role for the performance and the efficiency of the filter. In this paper, a new PWM method for the single phase current source type active power filter is presented, which is intended particularly for obtaining the maximum efficiency of the compensation. This method is basically based upon the optimized injection method, but in contrast to the existing method, this method adapts the optimized injection method by putting not only the pulse width, but also the pulse position into control variables. By doing this, when the number of pulses per one cycle is N, lower order harmonics up to the Nth order can be completely eliminated by the filter. So, this method is much more efficient than any other existing method. These characteristics are well verified by the computer simulations and the experiments.

  • PDF

Design of Central Directory Unit for Cache Coherence of Multiprocessor based on Intel486 Microprocessor (Intel486 병렬시스템의 Cache Coherence를 위한 Central Directory Unit의 설계)

  • You, Jun-Bok;Chung, Tae-Sang
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2684-2686
    • /
    • 2001
  • In order to utilize cache in multiprocessor system, cache coherence problem must be handled. Central directory scheme is one of hardware-assisted cache coherence solutions. The goal of this paper was not only to propose some special methods needed to apply central directory scheme to the specific multiprocessor system based on Intel486 microprocessors but also to design central directory unit for cache coherence of the target system. The problems of arbitrating several requests from processors, storing the cache information, and generating control signals for cache line fill and snoop cycle were solved.

  • PDF

Smokeless Starting for 4 Cycle Medium Speed Diesel Engine (4행정 중속 디젤기관의 스모크리스 시동)

  • Jung, Suk-Ho
    • Journal of Power System Engineering
    • /
    • 제18권4호
    • /
    • pp.11-16
    • /
    • 2014
  • Although smoke emitted from ships is not included in IMO(International Maritime Organiztion) regulation yet, it is one of the substance what is polluting mainly the air. Especially, its concentration is very high when an engine is started and a load is rapidly changed. This is caused by unburned fuel what is injected more than necessary quantity after combustion period. It is possible to decrease smoke concentration emitted at starting engine by controlling fuel injection quantity, but it is concerned that time to rated speed must be spent. Then a governor what can reduce the smoke concentration without a loss of time to rated speed is needed. We adopted a electro-hydraulic governor what can control dual fuel start limit function and achieved very low level of smoke concentration without greater the loss of time to rated speed.