• Title/Summary/Keyword: One point detection

Search Result 374, Processing Time 0.025 seconds

A Systolic Array Structured Decision Feedback Equalizer based on Extended QR-RLS Algorithm (확장 QR-RLS 알고리즘을 이용한 시스토릭 어레이 구조의 결정 궤환 등화기)

  • Lee Won Cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.11C
    • /
    • pp.1518-1526
    • /
    • 2004
  • In this paper, an algorithm using wavelet transform for detecting a cut that is a radical scene transition point, and fade and dissolve that are gradual scene transition points is proposed. The conventional methods using wavelet transform for this purpose is using features in both spatial and frequency domain. But in the proposed algorithm, the color space of an input image is converted to YUV and then luminance component Y is transformed in frequency domain using 2-level lifting. Then, the histogram of only low frequency subband that may contain some spatial domain features is compared with the previous one. Edges obtained from other higher bands can be divided into global, semi-global and local regions and the histogram of each edge region is compared. The experimental results show the performance improvement of about 17% in recall and 18% in precision and also show a good performance in fade and dissolve detection.

A Method of Adative Background Image Generation for Object Tracking (객체 추적을 위한 적응적 배경영상 생성 방법)

  • Jee, Jeong-Gyu;Lee, Kwang-Hyoung;Kim, Yong-Gyun;Oh, Hae-Seok
    • The KIPS Transactions:PartB
    • /
    • v.10B no.3
    • /
    • pp.329-338
    • /
    • 2003
  • Object tracking in a real time image is one of Interesting subjects in computer vision and many practical application fields past couple of years. But sometimes existing systems cannot find object by recognize background noise as object. This paper proposes a method of object detection and tracking using adaptive background image in real time. To detect object which does not influenced by illumination and remove noise in background image, this system generates adaptive background image by real time background image updating. This system detects object using the difference between background image and input image from camera. After setting up MBR(minimum bounding rectangle) using the internal point of detected object, the system tracks object through this MBR. In addition, this paper evaluates the test result about performance of proposed method as compared with existing tracking algorithm.

Development of Nutrition Screening Index for Hospitalized Patients (입원 환자 영양검색 지표 개발)

  • Kim, Su-An;Kim, So-Yeon;Sohn, Cheong-Min
    • Korean Journal of Community Nutrition
    • /
    • v.11 no.6
    • /
    • pp.779-784
    • /
    • 2006
  • Several studies about hospital malnutrition have been reported that about more than 40% of hospitalized patients are having nutritional risk factors and hospital malnutrition presents a high prevalence. People in a more severe nutritional status ended up with a longer length of hospital stay and higher hospital cost. Nutrition screening tools identify individuals who are malnourished or at risk of becoming malnourished and who may benefit from nutritional support. For the early detection and treatment of malnourished hospital patients , few valid screening instruments fur Koreans exist. Therefore, the aim of this study was to develop a simple, reliable and valid malnutrition screening tool that could be used at hospital admission to identify adult patients at risk of malnutrition using medical electrical record data. Two hundred and one patients of the university affiliated medical center were assessed on nutritional status and classified as well nourished, moderately or severely malnourished by a Patient-Generated subjective global assessment (PG-SGA) being chosen as the 'gold standard' for defining malnutrition. The combination of nutrition screening questions with the highest sensitivity and specificity at prediction PG-SGA was termed the nutrition screening index (NSI). Odd ratio, and binary logistic regression were used to predict the best nutritional status predictors. Based on regression coefficient score, albumin less than 3.5 g/dl, body mass index (BMI) less than $18.5kg/m^2$, total lymphocyte count less than 900 and age over 65 were determined as the best set of NSI. By using best nutritional predictors receiver operating characteristic curve with the area under the curve, sensitivity and 1-specificity were analyzed to determine the best optimal cut-off point to decide normal or abnormal in nutritional status. Therefore simple and beneficial NSI was developed for identifying patients with severe malnutrition. Using NSI, nutritional information of the severe malnutrition patient should be shared with physicians and they should be cared for by clinical dietitians to improve their nutritional status.

Detection of the Ryanodine Receptor Gene Mutation Associated with Porcine Stress Syndrome from Pig Hair Roots by PCR-RFLP (PCR-RFLP 기법을 이용한 Porcine Stress Syndrome의 진단)

  • Hwang, Eui-Kyung;Kim, Yeon-Soo
    • Korean Journal of Veterinary Research
    • /
    • v.42 no.1
    • /
    • pp.65-71
    • /
    • 2002
  • We have utilized the PCR-RFLP method to detect the ryanodine receptor(RYR1) gene mutation and to estimate the genotype frequencies of the RYR1 gene in commercial crossbred pig population. The exon region(659bp) including point mutation(C ${\rightarrow}$T; Arg ${\rightarrow}$Cys) in the porcine ryanodine receptor gene, which is a causal mutation for PSS, was amplified by PCR and digested with Cfo I restriction enzyme. The RYR1 gene was classified into three genotypes by agarose gel electrophoresis. The normal homozygous(NN) individuals showed two DNA fragments consisted of 493 and 166bp. The mutant homozygous(nn) individuals showed only one DNA fragment of 659bp. Also, all three fragments(659, 493 and 166bp) were showed in heterozygous(Nn) carrier animals. The proportions of normal, carrier and PSS pigs within crossbred population of pigs were 81%, 15% and 4%, respectively. According to the results of analysis of variance for the association of genotypes of RYR1 of pigs at 30kg, day age at 90kg and average daily gains, the RYR1 nn genotype was very higher than RYR1 NN genotype for day age at 30kg with 5% level of significant difference, but no significant difference for association of any other genotypes with day age at 90kg and average daily gain in crossbred pigs. Therefore, DNA diagnosis by using PCR-RFLP analysis for the PSS gene was useful for large-scale screening of commercial pigs in the swine industry.

A Filtering Method of Malicious Comments Through Morpheme Analysis (형태소 분석을 통한 악성 댓글 필터링 방안)

  • Ha, Yeram;Cheon, Junseok;Wang, Inseo;Park, Minuk;Woo, Gyun
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.9
    • /
    • pp.750-761
    • /
    • 2021
  • Even though the replying comments on Internet articles have positive effects on discussions and communications, the malicious comments are still the source of problems even driving people to death. Automatic detection of malicious comments is important in this respect. However, the current filtering method of the malicious comments, based on forbidden words, is not so effective, especially for the replying comments written in Korean. This paper proposes a new filtering approach based on morpheme analysis, identifying coarse and polite morphemes. Based on these two groups of morphemes, the soundness of comments can be calculated. Further, this paper proposes various impact measures for comments, based on the soundness. According to the experiments on malicious comments, one of the impact measures is effective for detecting malicious comments. Comparing our method with the clean-bot of a portal site, the recall is enhanced by 37.93% point and F-measure is also enhanced up to 47.66 points. According to this result, it is highly expected that the new filtering method based on morpheme analysis can be a promising alternative to those based on forbidden words.

Multidimensional Cancer Monitoring Index Framework for Developing Regional Cancer Monitoring Index: Based on Cancer Continuum (지역별 암모니터링 지표 개발을 위한 다차원적 암모니터링 지표 프레임워크: 암 환자 생애 연속성에 기반하여)

  • Kwon, Jeoung A;Kim, Jae-Hyun;Jang, Jieun;Kim, Woorim;Jeon, Miseon;Chung, Seungyeon;Vasuki, Rajaguru;Shin, Jaeyong
    • Health Policy and Management
    • /
    • v.30 no.4
    • /
    • pp.433-437
    • /
    • 2020
  • Cancer is a disease which has the huge burden in worldwide, and cancer is the number one cause of death in Korea. At this point, the new framework for cancer monitoring index is required for regional cancer monitoring. Especially, cancer survivors are the important target which is rapidly increasing recently, also cancer survivor's quality of care should be considered in the cancer monitoring index framework. To develop the Multidimensional Cancer Monitoring Index considering cancer survivor's quality of care, we took into account cancer continuum which including prevention, detection, diagnosis, treatment, survivorship, assessment of quality of care and monitoring cancer patient, and end-of life care for stage. For target, components of health care delivery system such as patient, family, provider, payer, and policy maker are included. Also, Donabedian model which is a framework for examining health services and evaluating quality of health care such as structure, process, and outcome is applied to contents. This new cancer monitoring framework which includes multidimensional components could help to develop regional cancer monitoring index, and to make national cancer management and prevention policy in the future.

Image Quality and Lesion Detectability of Lower-Dose Abdominopelvic CT Obtained Using Deep Learning Image Reconstruction

  • June Park;Jaeseung Shin;In Kyung Min;Heejin Bae;Yeo-Eun Kim;Yong Eun Chung
    • Korean Journal of Radiology
    • /
    • v.23 no.4
    • /
    • pp.402-412
    • /
    • 2022
  • Objective: To evaluate the image quality and lesion detectability of lower-dose CT (LDCT) of the abdomen and pelvis obtained using a deep learning image reconstruction (DLIR) algorithm compared with those of standard-dose CT (SDCT) images. Materials and Methods: This retrospective study included 123 patients (mean age ± standard deviation, 63 ± 11 years; male:female, 70:53) who underwent contrast-enhanced abdominopelvic LDCT between May and August 2020 and had prior SDCT obtained using the same CT scanner within a year. LDCT images were reconstructed with hybrid iterative reconstruction (h-IR) and DLIR at medium and high strengths (DLIR-M and DLIR-H), while SDCT images were reconstructed with h-IR. For quantitative image quality analysis, image noise, signal-to-noise ratio, and contrast-to-noise ratio were measured in the liver, muscle, and aorta. Among the three different LDCT reconstruction algorithms, the one showing the smallest difference in quantitative parameters from those of SDCT images was selected for qualitative image quality analysis and lesion detectability evaluation. For qualitative analysis, overall image quality, image noise, image sharpness, image texture, and lesion conspicuity were graded using a 5-point scale by two radiologists. Observer performance in focal liver lesion detection was evaluated by comparing the jackknife free-response receiver operating characteristic figures-of-merit (FOM). Results: LDCT (35.1% dose reduction compared with SDCT) images obtained using DLIR-M showed similar quantitative measures to those of SDCT with h-IR images. All qualitative parameters of LDCT with DLIR-M images but image texture were similar to or significantly better than those of SDCT with h-IR images. The lesion detectability on LDCT with DLIR-M images was not significantly different from that of SDCT with h-IR images (reader-averaged FOM, 0.887 vs. 0.874, respectively; p = 0.581). Conclusion: Overall image quality and detectability of focal liver lesions is preserved in contrast-enhanced abdominopelvic LDCT obtained with DLIR-M relative to those in SDCT with h-IR.

Study on the expression and detection of the p53 mutation in Korean colon cancer cell lines (한국인의 대장암 세포주에서 p53 돌연변이의 발견과 발현에 관한 연구)

  • Jung, Ji-Yeon;Oh, Sang-Jin
    • IMMUNE NETWORK
    • /
    • v.1 no.2
    • /
    • pp.151-161
    • /
    • 2001
  • Background: Inactivation in p53 tumor suppressor gene through a point mutation and deletion is one of the most frequent genetic changes found in human cancer, with 50% of an incidence. This high rate of mutation mostly suggests that the gene plays a central role in the development of cancer and the mutations detected so far were found in exons 5 to 8. Mutation of p53 locus produced accumulation of abnormal p53 protein, and negative regulation of cell proliferation and transcriptional activation as a suppressor of transformation were lost. In addition, inhibition of its normal cellular function of wild-type by mutant is an important step in tumorigenesis. Method: 4 colon cancer cell lines (SNU C1, C2A, C4, C5) were examined for mutation in exons 5 to 8 of the p53 tumor suppressor gene by PCR-SSCP analysis and expression pattern by western blotting and immunoprecipitation. p53-mediated transactivation ability were examined by CAT assay and base substitution of p53 in SNU C2A cell were detected by DNA sequencing. Results: 1) SNU C2A cell and SNU C5 cell were detected mobility shifts each in exon 5 and exon 7 of p53 gene by the PCR-SSCP method, implicating being of p53 mutation. 2) 3 colon cancer cell lines (SNU C1, SNU C2A, SNU C5) expressed wild type and mutant type p53 protein. 3) In northern blot experiment, SNU C2A and SNU C5 cell expressed high level of p53 mRNA. 4) Results of p53-mediated transactivation in colon cancer cell lines by CAT assay represented only SNU C2A cell has transcriptional activity. 5) DNA sequencing in SNU C2A cell showed missense mutation in codon 179 of one allele, histidine to arginine and wild type p53 in the other allele. Conclusion: Colon cancer cell lines showed correlation with mutation in p53 gene and accumulation of abnormal p53 protein. Colon cancer cell SNU C2A retained p53-mediated transactivation as heterozygous p53 with one mutant allele in 179 codon and the other wild-type allele.

  • PDF

Implication of embB Gene Mutation in Ethambutol-Susceptible Clinical Isolates of Mycobacterium tuberculosis (임상에서 분리된 에탐부톨 감수성균에서의 embB 유전자 돌연변이에 대한 고찰)

  • Park, Young Kil;Shin, Sonya;Kim, Sang Jae;Koh, Won-Jung;Kwon, O Jung;Kim, Bum Jun;Kook, Yoon Ho;Cho, Sang Nae;Lew, Woo Jin;Bai, Gill Han
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.3
    • /
    • pp.266-271
    • /
    • 2005
  • Background : Ethambutol(EMB) is one of the first-line drugs included in short-course anti-tuberculosis therapy. The point mutations in embB gene have been speculated to be associated EMB resistance. However, detection of embB mutations at these positions have been observed in both EMB-susceptible isolates; thus, it remains controversial whether these mutations are associated with EMB resistance Methods : The 36 M. tuberculosis isolates were selected from clinical isolates which tested susceptible to EMB and resistant to at least one drug. DNA extracted from the isolates was analyzed by amplifying embB gene. The PCR products were purified and directly sequenced. We reviewed the history of past drug susceptibility test results. Results : Out of 36 EMB-susceptible strains, 3 strains (8.3%) had a mutation in codon 306 or 406 of the embB gene. These three strains had at least isoniazid resistance. They grew at 1.0 mcg/ml of EMB in Lowenstein-Jensen media. The patients of the strains were continuously smear-positive for over 3 years despite taking TB therapy. One strain had been EMB-resistant in past drug susceptibility tests. Conclusion : EMB-susceptible strains containing embB mutation may be caused by decreased viability in vitro test not by itself.

Data Qualification of Optical Emission Spectroscopy Spectra in Resist/Nitride/Oxide Etch: Coupon vs. Whole Wafer Etching

  • Kang, Dong-Hyun;Pak, Soo-Kyung;Park, George O.;Hong, Sang-Jeen
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.433-433
    • /
    • 2012
  • As the requirement in patterning geometry continuously shrinks down, the termination of etch process at the exact time became crucial for the success in nano patterning technology. By virtue of real-time optical emission spectroscopy (OES), etch end point detection (EPD) technique continuously develops; however, it also faced with difficulty in low open ratio etching, typically in self aligned contact (SAC) and one cylinder contact (OCS), because of very small amount of optical emission from by-product gas species in the bulk plasma glow discharge. In developing etching process, one may observe that coupon test is being performed. It consumes costs and time for preparing the patterned sample wafers every test in priority, so the coupon wafer test instead of the whole patterned wafer is beneficial for testing and developing etch process condition. We also can observe that etch open area is varied with the number of coupons on a dummy wafer. However, this can be a misleading in OES study. If the coupon wafer test are monitored using OES, we can conjecture the endpoint by experienced method, but considering by data, the materials for residual area by being etched open area are needed to consider. In this research, we compare and analysis the OES data for coupon wafer test results for monitoring about the conditions that the areas except the patterns on the coupon wafers for real-time process monitoring. In this research, we compared two cases, first one is etching the coupon wafers attached on the carrier wafer that is covered by the photoresist, and other case is etching the coupon wafers on the chuck. For comparing the emission intensity, we chose the four chemical species (SiF2, N2, CO, CN), and for comparing the etched profile, measured by scanning electron microscope (SEM). In addition, we adopted the Dynamic Time Warping (DTW) algorithm for analyzing the chose OES data patterns, and analysis the covariance and coefficient for statistical method. After the result, coupon wafers are over-etched for without carrier wafer groups, while with carrier wafer groups are under-etched. And the CN emission intensity has significant difference compare with OES raw data. Based on these results, it necessary to reasonable analysis of the OES data to adopt the pre-data processing and algorithms, and the result will influence the reliability for relation of coupon wafer test and whole wafer test.

  • PDF