• Title/Summary/Keyword: One Scan Method

Search Result 297, Processing Time 0.036 seconds

An Application of Remote Sensing Method for Close-to-nature Stream Evaluation : Focusing on Vegetation Index of Multi-Spectral Satellite Image (자연형 하천평가를 위한 원격탐사법 응용 : 다중파장 위성영상의 식생지수 중심)

  • Yoon, Yeong-Bae;Cho, Hong-Je;Kim, Geun-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.462-466
    • /
    • 2006
  • Close-to-nature stream evaluation is one of the processing to make the streams over in order to keep them natural. It is integral to evaluate and make an accurate analysis of them on the purpose of maintaining streams healthy. For many instances, there are, stream organization evaluation for restoration by German government, evaluation for ecosystem protection in natural preserves by New Zealand government, and stream-view evaluation for restoration by Britain government so on. In case of the country there are analysis and evaluation of stream physical organization by Cho, Yong-hyun, Close-to-nature stream evaluation for restoration by Kim, Dong-chan, evaluation of stream properties in korea by Park, Bong-jin. Close-to-nature evaluation by Lim, Chan-uk, that is advanced version of Park, Bong-jin's, shows form of stream including waterway curve, sand bar, diversity of flow, river bed material, diversity of minor bed, minor bed bank protection works, bank protection material. It also does environment of stream including side of minor bed vegetation, width of surface of the water/width of the river etc.. By the way, this evaluation does not have free access to apply those details above in the field, it often happens that you get various outcome from the one spot. so you must need more realistic testing method to obtain more accurate data. Remote sensing method is highly recommended because this is very useful for collecting realistic data of vegetation index. what is more, it can not only scan even the minimum area within its resolving power but also do obtain data anytime. Vegetation index indicates Ratio vegetation index, Normalized difference vegetation index, Soil adjusted vegetation index, Atmospherically resistant vegetation index etc.. The research is focusing on Cheokgwa stream which is the branch of Taehwa river and shows 19 sectioned Close-to-nature stream performed according to the method by Lim, chan-uk. Besides let you know vegetation index came from image data of satellite landsat 7 with the variation of buffering area, of the day 9. may. 2003. Of all, the outcome 0.758 at 200m buffer-zone of NDVI was the best we have got so far.

  • PDF

News Video Shot Boundary Detection using Singular Value Decomposition and Incremental Clustering (특이값 분해와 점증적 클러스터링을 이용한 뉴스 비디오 샷 경계 탐지)

  • Lee, Han-Sung;Im, Young-Hee;Park, Dai-Hee;Lee, Seong-Whan
    • Journal of KIISE:Software and Applications
    • /
    • v.36 no.2
    • /
    • pp.169-177
    • /
    • 2009
  • In this paper, we propose a new shot boundary detection method which is optimized for news video story parsing. This new news shot boundary detection method was designed to satisfy all the following requirements: 1) minimizing the incorrect data in data set for anchor shot detection by improving the recall ratio 2) detecting abrupt cuts and gradual transitions with one single algorithm so as to divide news video into shots with one scan of data set; 3) classifying shots into static or dynamic, therefore, reducing the search space for the subsequent stage of anchor shot detection. The proposed method, based on singular value decomposition with incremental clustering and mercer kernel, has additional desirable features. Applying singular value decomposition, the noise or trivial variations in the video sequence are removed. Therefore, the separability is improved. Mercer kernel improves the possibility of detection of shots which is not separable in input space by mapping data to high dimensional feature space. The experimental results illustrated the superiority of the proposed method with respect to recall criteria and search space reduction for anchor shot detection.

Accuracy of Ventricular Volume and Ejection Fraction Measured by Gated Tl-201 Perfusion Single Photon Emission Tomography (심전도 게이트 심근관류 Tl-201 SPECT로 측정된 좌심실 기능 및 좌심실 용적의 정확성)

  • Pai, Moon-Sun;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.94-99
    • /
    • 2005
  • Electrocardiogram-gated single photon omission computed tomography (SPECT) provides valuable information in the assessment of both myocardial perfusion and ventricular function. Tl-201 is a suboptimal isotope for gating. Tl-201 images are more blurred compared with Tc-99m tracers due to the increased amount of scattered photons and use of a smooth filter. The average myocardial count densities are approximately one-half those of conventional technetium tracers. However, Tl-201 is still widely used because of its well-established utility for assessing myocardial perfusion, viability and risk stratification. Gated SPECT with Tl-201 enables us to assess both post-stress and rest left ventricular volume and function. Previous studies with gated Tl-201 SPECT measurements of ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) have shown high correlation with first-pass radionuclide angiography, gated blood pool scan, Tc-99m-MIBI gated SPECT, contrast ventriculography, echocardiography, and 3-dimensional magnetic resonance imaging. However, problems related to these studies include few agreement data of EDV and ESV, use of a reference method that is likely to have the same systemic errors (gated Tc-99m-MIBI SPECT), and other technical factors related to the count density of gated SPECT. With optimization of gated imaging protocols and more validation studies, gated Tl-201 SPECT would be an accurate method to provide perfusion and function information in patients with coronary artery disease.

Implementation of AUSV System for Sonar Image Acquisition (소나 영상 획득을 위한 무인자율항법 시스템 구현)

  • Ryu, Jae Hoon;Ryu, Kwang Ryol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.11
    • /
    • pp.2162-2166
    • /
    • 2016
  • This paper describes the implementation of AUSV system for sonar image acquisition to survey the seabed. The system is controlled by Feed Forward PID algorithm on the vessel for bearing of the thrusters composed of motion sensor and DGPS which calculates the differences between the current location and the destination location for longitude and latitude based on GPS coordinates. As experimental results, the bearing control performance is good that the error distance from the destination positions are under 6m in total survey track of 1km. And the sonar image deviation of a object is under 12 pixels from the manned survey method, which the comparison with the total image quality is almost the same as the manned survey one. Thus the proposed AUSV system is a new method of system can be utilized at the limited survey areas as the surveyor should not be able to approach on sea surface by onboard vessel.

An Analysis of Risk Factors in Stomal Recurrence after Total Layngectomy (후두전적출술후 기관공재발의 위험요소 분석)

  • Park, Ji-Hoon;Kim, Hyung-Jin;Oh, Byung-Hoon;Choi, Geon;Jung, Kwang-Yoon;Choi, Jong-Ouck
    • Korean Journal of Bronchoesophagology
    • /
    • v.6 no.1
    • /
    • pp.80-86
    • /
    • 2000
  • Background : Stomal recurrence that occasionally follows total laryngectomy is associated with very poor prognosis regardless of treatment modality, so it is very important to identify high risk patients to prevent stomal recurrence. Objectives : We attempted to select an optimal management method to prevent stomal recurrence by analyzing risk factors in each patient who was found to have stomal recurrence following total laryngectomy. Materials and Methods : Risk factors in each of eleven patients who had stomal recurrence out of 159 patients who underwent total laryngectomy in the last ten years were analyzed retrospectively. Data were gathered on risk factors such as the presence of subglottic extension, extralaryngeal extension, thyroid gland invasion, lymph node metastasis, timing of tracheotomy, tumor stage, postoperative radiotherapy, and inclusion of the stoma in the radiotherapy field. Results : There were eight cases of subglottic extension, six cases of extralaryngeal invasion, one case of pharyngocutaneous fistula that occurred as a postoperative complication, and one case who was taken completion laryngectomy following conservation surgery. With the exception of one case who was taken tracheotomy prior to total laryngectomy, all tracheotomies were performed intra-operatively after endotracheal intubation. There was no evidence of paratracheal lymph node or prelaryngeal lymph node metastasis on preoperative neck CT scan. There were six cases of T4 tumors, four cases of T3 tumors, and one case of T2 tumor. Salvage surgery was performed following radiotherapy in three cases, and aside from one case who was not taken post-operative radiotherapy, postoperative radiotherapy including the stoma was performed in the remaining seven cases within one month after surgery. Conclusion : Total laryngectomy with wide paratracheal lymph node dissection, thyroidectomy, and tracheotomy should be performed for patients who have high risk factors such as subglottic extension and advanced stage. We believe that tracheotomy should be precede endotracheal intubation. Efforts should be made to prevent stomal recurrence by utilizing postoperative radiotherapy and by minimizing postoperative complications such as infection and fistula.

  • PDF

Marginal and internal fit of interim crowns fabricated with 3D printing and milling method (3D 프린팅 및 밀링 방법으로 제작된 임시 보철물 적합도 비교 분석)

  • Son, Young-Tak;Son, KeunBaDa;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.254-261
    • /
    • 2020
  • Purpose: The purpose of this study was to assess the marginal and internal fit of interim crowns fabricated by two different manufacturing method (subtractive manufacturing technology and additive manufacturing technology). Materials and Methods: Forty study models were fabricated with plasters by making an impression of a master model of the maxillary right first molar for ceramic crown. On each study model, interim crowns (n = 40) were fabricated using three types of 3D printers (Meg-printer 2; Megagen, Zenith U; Dentis, and Zenith D; Dentis) and one type milling machine (imes-icore 450i; imes-icore GmbH). The internal of the interim crowns were filled with silicon and fitted to the study model. Internal scan data was obtained using an intraoral scanner. The fit of interim crowns were evaluated in the margin, absolute margin, axial, cusp, and occlusal area by using the superimposition of 3D scan data (Geomagic control X; 3D Systems). The Kruskal-wallis test, Mann-Whitney U test and Bonferroni correction method were used to compare the results among groups (α = 0.05). Results: There was no significant difference in the absolute marginal discrepancy of the temporary crown manufactured by three 3D printers and one milling machine (P = 0.812). There was a significant difference between the milling machine and the 3D printer in the axial and occlusal area (P < 0.001). The temporary crown with the milling machine showed smaller axial gap and higher occlusal gap than 3D printer. Conclusion: Since the marginal fit of the temporary crown produced by three types of 3D printers were all with in clinically acceptable range (< 120 ㎛), it can be sufficiently used for the fabrication of the temporary crown.

Diagnostic Value of Transbronchial Lung Biopsy -Including Diagnostic Yield According to Tumor-bronchus Relationship- (경기관지폐생검의 진단적 가치 -병변과 기관지의 관계에 따른 진단율을 포함한 연구-)

  • Kang, Tae-Kyong;Cha, Seung-Ick;Park, Jae-Yong;Chae, Sang-Chul;Kim, Chang-Ho;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.4
    • /
    • pp.438-447
    • /
    • 2000
  • Background : Transbronchial lung biopsy (TBLB) is a relatively simple and convenient procedure to obtain lung tissue from a patient with diffuse or localized lesion on chest radiographs, whose disease cannot be diagnosed through routine tests. The authors tried to evaluate the diagnostic value of TBLB, especially, the concordance between CT scan and TBLB with respect to the location of the lesion and diagnostic yield according to tumor-bronchus relationship. Method : We reviewed the medical records, plain chest films, and chest CT scans of 278 patients who underwent TBLB at Kyungpook National University Hospital between January 1996 and June 1998. Results : One hundred and sixteen (41.7 %) patients were diagnosed by TBLB. Diagnostic yield of TBLB of malignant tumors tended to be higher than that of benign diseases (64.7% versus 53.9%, p=0.09). Of primary lung cancers, TBLB was more diagnostic in adenocarcinoma and small-cell carcinoma than other cell types (p<0.01) and, of benign diseases, more diagnostic in tuberculosis than in non-tuberculous diseases (p<0.05). There was no significant difference in the diagnostic rate according to the location of the tumor. The diagnostic rate tended to increase with the size of tumor (p=0.06). The diagnootic rate of TBLB did not differ according to the pattern of lesion in benign diseases. However, in malignant diseases TBLB was more diagnostic in diffuse/multiple nodular lesions than in localized lesions(p<0.05). According to the tumor-bronchus relationship, TBLB was more diagnootic in type I/II groups than in other types. CT scan and TBLB showed a strong correlation with respect to the localization of the lesion (r=0.994, p<0.01). Conclusion : The above results show that TBLB is useful in the diagnosis of lung disease. CT scan and TBLB showed a strong correlation in determining the location of the lesion. Diagnostic yield of TBLB is higher in lesions with 'bronchus sign' (type I and II). TBLB and other diagnootic methods such as transthoracic needle aspiration are expected to complement one another in the diagnosis of lung diseases.

  • PDF

Cortical Thickness Estimation Using DIR Imaging with GRAPPA Factor 2 (DIR 영상을 이용한 피질두께 측정: GRAPPA 인자 2를 이용한 비교)

  • Choi, Na-Rae;Nam, Yoon-Ho;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.1
    • /
    • pp.56-63
    • /
    • 2010
  • Purpose : DIR image is relatively free from susceptibility artifacts therefore, DIR image can make it possible to reliably measure cortical thickness/volume. One drawback of the DIR acquisition is the long scan time to acquire the fully sampled 3D data set. To solve this problem, we applied a parallel imaging method (GRAPPA) and verify the reliability of using the volumetric study. Materials and methods : Six healthy volunteers (3 males and 3 females; age $25.33{\pm}2.25$ years) underwent MRI using the 3D DIR sequence at a 3.0T Siemens Tim Trio MRI scanner. GRAPPA simulation was performed from the fully sampled data set for reduction factor 2. Data reconstruction was performed using MATLAB R2009b. Freesurfer v.4.3.0 was used to evaluate the cortical thickness of the entire brain, and to extract white matter information from the DIR image, Analyze 9.0 was used. The global cortical thickness estimated from the reconstructed image was compared with reference image by using a T-test in SPSS. Results : Although reduced SNR and blurring are observed from the reconstructed image, in terms of segmentation the effect was not so significant. The volumetric result was validated that there were no significant differences in many cortical regions. Conclusion : This study was performed with DIR image for a volumetric MRI study. To solve the long scan time of 3D DIR imaging, we applied GRAPPA algorithm. According to the results, fast imaging can be done with reduction factor 2 with little loss of image quality at 3.0T.

Scintigraphy with Indium-111-oxine Labeled Leukocytes for Localization of Abscesses (복부농양진단을 위한 Indium-111 표지백혈구스캔)

  • Kim, Byung-Tae;Lee, Dong-Soo;Lee, Kyung-Soo;Choi, Hyung-Shik;Kim, Myung-Joon;Yang, Seung-O;Lee, Jae-Hoon;Choi, Chang-Soon;Kim, Taek-Kyu;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.1
    • /
    • pp.37-48
    • /
    • 1990
  • Detection of deep-seated abscesses is sometimes difficult with ultrasonogrpahy or computed tome graphy alone. Indium-111-labeled leukocyte has widely used in the localization of abscesses after introduction by Segal and Thakur in 1976. But there are some difficulties in using indium-111-oxine in our country because of hardness to get the radiopharmaceutical timely and long time for labeling leukocytes. So we peformed the indium-111-labeled leukocyte scan for establishment of the labeling procedure and clinical application. We labeled the mixed leukocytes from 36 ml of patient's blood using 4 ml of ACD solution, 7 ml of 6% hydroxyethyl starch solution $(HESPAN^{(R)})$, 1 mCi of indium-111 oxine, 5 ml of normal saline and centrifuge. It took about 2 hours for the preparation of radiolabeled leukocytes and attention for contamination was needed. The average injected dose of labeled mixed leukocytes was 465 uCi. The average number of injected leukocytes was $2.5\times10^8$ and the labeling ratio was $57{\pm}13%$ (Table 2, Fig. 5). These number and ratio were sufficient for the localization of abscess. About twenty per cent of indium was labeled to red blood cells and platelets (Fig. 6) and the half-life of injected radiolabeled leukocytes was 8.3 hours. Scan was performed in 9 patients who were suspected to have abscesses clinically or radiologically. Three patients were positive, in one patient who had abscess close to lower lumbar vertebrae was surgically drained and another 2 positive cases did not show abscess clearly on computed tomography, so only antibiotics were administrated and treated successfully. The negative 6 patients were improved without specific treatment. In conclusion, the use of indium-111 oxine labeled leukocytes for localization of abscesses were very specific and helpful in the decision of treatment considering its relatively simple labeling method, and could be easily performed providing timely supply of the radiopharmaceutical.

  • PDF

Classification of Urinary Stone into Uric Acid & Non-uric Acid by Dual-Energy (이중에너지 전산화단층촬영을 이용한 요로결석의 성분 분석에 관한 연구)

  • Myung-Jin Jung;Sung-Gil Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.835-841
    • /
    • 2023
  • The aim of this study is to evaluate the diagnostic ability of dual-energy computed tomography (DECT) for Composition determination of urinary stones in phantom model. Seventeen cases with urinary stones who underwent DECT were enrolled in the study. The composition of the urinary stones was extracted from the seventeen patients were analyzed with DECT in phantom model with fresh pork. The volume scan method using Dual-energy software was used and the scanned image sets were assessed. All 17 urinary stones of the phantom model were analyzed according to the stone composition using DE stone Analysis were divided into uric acid stones (n=6, 35.29%) and non-uric acid stones (n=11, 64.71%). These urinary stones were pathologically confirmed. The mean attenuation values of uric acid stones at 135 kV, 100 kV and 80 kV was 348.87 ± 166.37 HU, 345.33 ± 151.18 HU and 337.94 ± 172.77 HU, respectively. The mean attenuation values of non-uric acid stones at 135 kV, 100 kV and 80 kV was 551.93 ± 297.09 HU, 747.04 ± 351.31 HU and 958.19 ± 424.72 HU, respectively. At 80 kV, uric acid stones and non-uric acid stones showed significant difference in the attenuation values(P<0.05). The attenuation values of DECT could differentiate the compositions of urinary stones between uric acid and non-uric acid stones at 80 kV in phantom model.