• 제목/요약/키워드: On-load time

검색결과 4,382건 처리시간 0.032초

Characteristics analysis of local ice load signals in ice-covered waters

  • Lee, Jong-Hyun;Kwon, Yong-Hyeon;Rim, Chae-Whan;Lee, Tak-Kee
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제8권1호
    • /
    • pp.66-72
    • /
    • 2016
  • The aim of this paper is to investigate the characteristics of the signal of local ice load acting on side shell in the bow part due to ice broken by an icebreaker in ice-covered waters. The Korean icebreaking research vessel "ARAON" voyaged to the Arctic Ocean during the summer of 2010, and measurements of local ice load were carried out using several strain gauges. In this study, the time history of measured signals was analyzed and the characteristic values including rising time and half-decaying time were presented using non-dimensional parameters.

저온수를 이용하는 일중효용/이단승온 리튬브로마이드-물 흡수식 시스템의 동적 해석 (Dynamic Analysis of Single-Effect/Double-Lift Libr-Water Absorption System using Low-Temperature Hot Water)

  • 김병주
    • 설비공학논문집
    • /
    • 제21권12호
    • /
    • pp.695-702
    • /
    • 2009
  • Dynamic behavior of Libr-water absorption system using low-temperature hot water was investigated numerically. Thermal-hydraulic model of single-effect/double-lift 100 RT chiller was developed by applying transient conservation equations of total mass, Libr mass, energy and momentum to each component. Transient variations of system properties and transport variables were analysed during start-up operation. Numerical analysis were performed to quantify the effects of bulk concentration and part-load operation on the system performance in terms of cooling capacity, coefficient of performance, and time constant of system. For an absorption chiller considered in the present study, optimum bulk concentration was found to exist, which resulted in the minimum time constant with stable cooling capacity. COP and time constant increased as the load decreased down to 40%, below which the time constant increased abruptly and COP decreased as the load decreased further.

통신지연이 있는 분산처리의 최적화 (Optimal Distributed Computation with Communication Delays)

  • 김형중;지규인;이장규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.748-752
    • /
    • 1991
  • Tree network consisting of communicating processors is considered. The objective is to minimize the computation time by distributing the processing load to other nodes. The effect of the order of load distribution on the processing time is addressed. An algorithm which optimally determines the order of load distribution is developed. It is shown that the order depends only on the channel capacity between nodes but not on the computing capability of each node.

  • PDF

Dynamics of the system consisting of the hollow cylinder and surrounding infinite elastic medium under action an oscillating moving ring load on the interior of the cylinder

  • Akbarov, Surkay D.;Mehdiyev, Mahir A.
    • Coupled systems mechanics
    • /
    • 제7권5호
    • /
    • pp.525-554
    • /
    • 2018
  • The paper deals with the study of the dynamics of the oscillating moving ring load acting in the interior of the hollow circular cylinder surrounded by an elastic medium. The axisymmetric loading case is considered and the study is made by employing the exact equations and relations of linear elastodynamics. The focus is on the influence of the oscillation of the moving load and the problem parameters such as the cylinder's thickness/radius ratio on the critical velocities. At the same time, the dependence between the interface stresses and load moving velocity under various frequencies of this load, as well as the frequency response of the mentioned stresses under various load velocity are investigated. In particular, it is established that oscillation of the moving load can cause the values of the critical velocity to decrease significantly and at the same time the oscillation of the moving load can lead to parametric resonance. It is also established that the critical velocity decreases with decreasing of the cylinder's thickness/radiusratio.

전력부하의 확률가정적 최적예상식의 유도 및 전산프로그래밍에 관한 연구 (Study on a Probabilistic Load Forecasting Formula and Its Algorithm)

  • 고명삼
    • 전기의세계
    • /
    • 제22권2호
    • /
    • pp.28-32
    • /
    • 1973
  • System modeling is applied in developing a probabilistic linear estimator for the load of an electric power system for the purpose of short term load forecasting. The model assumer that the load in given by the suns of a periodic discrete time serier with a period of 24 hour and a residual term such that the output of a discrete time dynamical linear system driven by a white random process and a deterministic input. And also we have established the main forecasting algorithms, which are essemtally the Kalman filter-predictor equations.

  • PDF

시변하는 간단한 유체기계의 덕트 내 음원 특성에 대한 해석적 연구 (On the in-duct acoustical source characteristics of a simplified time-varying fluid machine)

  • 이정권;장승호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.517-521
    • /
    • 2001
  • Measurement techniques for the in-duct source characteristics of fluid machines can be classified into direct method and load method, according to whether the technique employs an external acoustic source or not. It has been known that the two methods yield different results and the load method used to come up with a negative source resistance, in spite of the fact that a very accurate prediction of radiated noise can be obtained by using any result. This paper is focused to the effect of time-varying nature of fluid machines on the output result. For this purpose, a simplified fluid machine consisting of a reservoir, a valve and a pipe is considered as representing a typical linear, periodic, time-varying system and the measurement techniques are simulated by utilizing the Hill equation and its steady-state forced response. In the load method, the source impedance turns out being dependent on the valve impedance at the calculation frequency and the valve and load impedances at other frequencies as well.

  • PDF

A Study on Indoor Environment of Interior with Ventilation

  • Kang, Tae-Wook;Koh, Jae-Yoon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.267-274
    • /
    • 2006
  • There are no solar loads through windows and heat transfer from outer walls of the building to the interior This study analyzes indoor air temperature and air flow distribution for the interior of buildings or vessels occupying space. Numerical method is adopted to visualize the indoor side environmental situation. that is without heat transmission to outside the building in various cooling load conditions; supply ventilation lighting. occupancy and infiltration in conditioned spaces. Reaching time of an air conditioner is predicted theoretically by cooling load variations. Theoretical modelling of the reaching time shows good agreement with experimental results.

시간 개념을 고려한 전과정평가 방법 (Life Cycle Assessment Considering Time)

  • ;박정건;이건모
    • 대한환경공학회지
    • /
    • 제29권6호
    • /
    • pp.722-727
    • /
    • 2007
  • 전과정평가(Life Cycle Assessment; LCA)는 전과정에 걸친 투입과 산출을 정량화하고, 잠재적인 환경 영향을 평가하는 도구이다. 기존 LCA 방법은 시간을 명확하게 고려하지 않는다는 결함이 있다. 또한 정규화(normalization)단계에서도 시간 경계에 관한 문제가 존재한다. 본 연구의 목적은 시간이 고려된 새로운 LCA 방법을 제안하는 것이다. 본 연구에서 제안하는 새로운 LCA 방법론인 '시간-부하 LCA'는 각각의 전과정단계에서 발생하는 환경 부하를 해당 전과정단계에서 소요되는 시간으로 나누는 것이다. 전과정평가에서 시간 고려를 명확히 함으로써 제품 시스템의 환경 영향에 대한 새로운 관점을 제공할 수 있을 뿐만 아니라 정규화 단계의 시간 단위 불일치를 보완할 수 있다. 시간-부하 LCA의 기본 전제는 같은 양의 환경 부하라 하더라도 짧은 시간 동안 발생하는 환경부하가 긴 시간 동안 발생하는 환경 영향보다 더 튼 환경 영향을 미칠 수 있다는 것이다. 그러므로 목록 파라미터가 환경에 미치는 영향을 평가할 때 시간 당 부하를 고려할 필요가 있다.

강제 송풍 증발기에 의한 자동제상장치의 최적제상시기에 관한 연구 (A Study on the Period of Optimum Defrost of Auto Defrost Unit by the Forced Fan Evaporator)

  • 구남열;이윤경;하옥남
    • 설비공학논문집
    • /
    • 제15권4호
    • /
    • pp.329-335
    • /
    • 2003
  • This study is on a experiment which shows to defrost automatically on the optimum time regardless of defrosting method. The result shows that the more defrost layers increase in fin tubes of evaporation, the less the section of the circulating air reduce. Thickness of the frost formation increases, so a pressure difference of ventilation increase, as a result automatic defrosting system sets the time COP drops suddenly up optimum time. Automatical defrosting system can find out the initial related current of evaporator fan motor and the value of load current in the optimum time. And it sets defrosting time, evaporating temperature, and temperature in refrigerator up system requiring value. Consequence of this experiment is that energy consumption with defrost load gets effect of reduction of eleven percent per 25.4 hours compared with common defrosting.

국내 전력계통 안정화를 위한 다단계 부하차단 제어전략 수립에 관한 연구 (A Study on Multi Level Load Shedding Control Scheme Strategy for Stabilization of the Korean Power System)

  • 이윤환
    • 전기학회논문지P
    • /
    • 제65권4호
    • /
    • pp.255-261
    • /
    • 2016
  • Korean Power System are operating a load shedding system to prevent voltage instability phenomenon caused by severe line contingencies. In order to apply the load shedding scheme should be selected a location, amount, delay time. Current load shedding system is load shedding amount that has been calculated in the steady-state analysis to load shed the total amount in first level, load shedding amount calculated in advance, it is possible to perform an unnecessary load shedding. In this paper, set a multi-level load shedding control strategy step-by-step selection of load shedding amount for the prevention of excessive load shedding. In addition, through a voltage resilience analysis of the power system by applying motor load ratio and sensitivity parameter to selection the multi level load shedding ratio and delay time. For this reason, to take advantage of the limit data of interchange power, by utilizing interface power flow data to set a multi-level load shedding control strategy for the stabilization of the Korean Power System.