• Title/Summary/Keyword: On-line solid phase extraction

Search Result 10, Processing Time 0.024 seconds

On-line SPE-HPLC Method using Alumina Filtering to Selectively Extract Phenolic Compounds from Environmental Water

  • Lee, Sung-Kwang
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.12
    • /
    • pp.3755-3759
    • /
    • 2010
  • A on-line SPE (solid phase extraction)-HPLC preconcentration method was developed for the determination of phenolic compounds at trace levels in environmental water sample. XAD-4 and Dowex 1-X8 were used as sorbent in the on-line SPE-HPLC method for the selective enrichment of nine phenolic compounds, which are included in the priority pollutants list of the US EPA. Also alumina prefiltering considerably reduced the amount of interfering peaks due to humic substances that could accumulated due to the preconcentration step and prevent quantification of polar phenolic compounds in environmental water samples. This method was used to determine the phenolic compounds in tap and river water and superiority to the US EPA 625 method in its enrichment factor, pretreatment time, recoveries, and detection limit. The limits of detection were in the range of $0.3-0.9\;{\mu}g/L$ in tap water sample.

Application of On-Line SPE-LC/MSD to Measure Perfluorinated Compounds (PFCs) in Water (On-Line SPE-LC/MSD 시스템을 이용한 수중의 과불화 화합물(PFCs) 분석)

  • Son, Hee-Jong;Yoom, Hoon-Sik;Jung, Jong-Moon;Jang, Seung-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.2
    • /
    • pp.75-83
    • /
    • 2013
  • We applied a sensitive method based on on-line solid-phase extraction (SPE) and liquid chromatography/mass spectrometry (LC/MSD) using an electrospray interface for the determination of eleven perfluorinated compounds (PFCs) in water. The on-line connection suppressed the target loss by keeping the cartridge from drying, which resulted in improvement of the recovery and saving of the analytical time. For the on-line solid-phase extraction of 10 mL water samples, recoveries were between $80.4{\pm}5.2%{\sim}109.5{\pm}1.4%$ and limit of quantification (LOQ) were 3.6~15.9 ng/L for the PFCs. The total PFCs concentrations of the tributaries and main stream of Nakdong River water samples were in the range of $8.0{\sim}678.6{\mu}g/L$.

Optimization for the Solid-Phase Extraction of Trace Clobazam from Biological Samples (생체시료로부터 미량 크로바잠의 고상추출을 위한 최적화)

  • Kim, Kyoung-Rae;Kim, Jeong-Ho;Kim, Hyub;Yoon, Hye-Ran
    • YAKHAK HOEJI
    • /
    • v.39 no.4
    • /
    • pp.395-400
    • /
    • 1995
  • The sorption and desorption properties of four adsorbents were evaluated for the trace enrichment of clobazam from biological samples. Graphitized carbon black(GCB) gaved the highest dynamic adsorption coefficient. Among the six organic solvents examined, acetone gave the highest desorption coefficient for the clobazam adsorbed on GCB. Using the GCB column, the optimum elution volume of the eluting solvent was evaluated from the on-line monitored breakthrough curve for clobazam. When GCB as the solid adsorbent and acetone as the eluting solvent were used for the solidphase extraction of clobazam from serum, the recoveries were higher than 83% with good reproducibility in the concentration range of 20-50 $\mu\textrm{g}$/ml.

  • PDF

Development of Analytical Method and Monitoring of Organophosphorus Pesticides in the Raw Water and Clean Water by Liquid Chromatography-Tandem Mass Spectrometry (LC/MS/MS를 이용한 유기인계 농약류의 최적 분석법 정립과 원·정수에서의 모니터링)

  • Kim, Gyung-A;Song, Mi-Jeong;Yeom, Hoon-Sik;Son, Hee-Jong;Lee, Sang-Won;Choi, Jin-Tack
    • Journal of Environmental Science International
    • /
    • v.24 no.12
    • /
    • pp.1569-1582
    • /
    • 2015
  • The analytical method for 16 organophosphorus pesticides was developed in this study. The 16 organophosphorus pesticides were analyzed by liquid chromatography-tandem mass spectrometry (LC/MS/MS) using on-line solid phase extraction (on-line SPE) with PLRP- S cartridge. Analysis of all analytes in the MS/MS was processed in the electrospray ioni-zation (ESI) positive mode. They are Azinphos ethyl, Chlorfenvinphos, Ethion, Famphur, Phosmet, Phosphamidon, Terbufos, Aspon, Chlorpyrifos-methyl, Crotoxyphos, Dichlofenthi-on, Dicrotophos, Fonofos, Thionazin, Dimethoate and Iprobenfos. Limits of detection (LODs) and Limits of quantification(LOQs) were obtained as 0.8~2.0 ng/L and 2.6~6.4 ng/L, respectively. All compounds were not detected at the 8 sampling points of the raw water and clean water.

Determination of Pesticide Residues in Water using On-line SPE-HPLC Coupling System

  • Lee, Dai Woon;Lee, Sung Kwang;Park, Young Hun;Paeng, Ki-Jung
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.539-543
    • /
    • 1995
  • The on-line SPE-HPLC coupling system was developed for the efficient separation and determination of trace pesticides, such as phenoxyacetic acids and esters, and triazines in aqueous solutions. By using the developed SPE-HPLC on-line system, the band broadening usually observed in single precolumn switching mode was greatly reduced, consequently, the quantitative determination of trace pesticides could be achieved, Besides, since most of the analytes preconcentrated by SPE column could be injected directly into HPLC system, the limit of detection can be improved down to ppt level.

  • PDF

Identification of bioactive components behind the antimicrobial activity of cow urine by peptide and metabolite profiling

  • Rohit Kumar;Jai Kumar Kaushik;Ashok Kumar Mohanty;Sudarshan Kumar
    • Animal Bioscience
    • /
    • v.36 no.7
    • /
    • pp.1130-1142
    • /
    • 2023
  • Objective: Cow urine possesses several bioactive properties but the responsible components behind these bioactivities are still far from identified. In our study, we tried to identify the possible components behind the antimicrobial activity of cow urine by exploring the peptidome and metabolome. Methods: We extracted peptides from the urine of Sahiwal cows belonging to three different physiological states viz heifer, lactation, and pregnant, each group consisting of 10 different animals. The peptides were extracted using the solid phase extraction technique followed by further extraction using ethyl acetate. The antimicrobial activity of the aqueous extract was evaluated against different pathogenic strains like Staphylococcus aureus, Escherichia coli, and Streptococcus agalactiae. The safety of urinary aqueous extract was evaluated by hemolysis and cytotoxicity assay on the BuMEC cell line. The urinary peptides were further fractionated using high-performance liquid chromatography (HPLC) to identify the fraction(s) containing the antimicrobial activity. The HPLC fractions and ethyl acetate extract were analyzed using nLC-MS/MS for the identification of the peptides and metabolites. Results: A total of three fractions were identified with antimicrobial activity, and nLC-MS/MS analysis of fractions resulted in the identification of 511 sequences. While 46 compounds were identified in the metabolite profiling of organic extract. The urinary aqueous extract showed significant activity against E. coli as compared to S. aureus and S. agalactiae and was relatively safe against mammalian cells. Conclusion: The antimicrobial activity of cow urine is a consequence of the feeding habit. The metabolites of plant origin with several bioactivities are eliminated through urine and are responsible for their antimicrobial nature. Secondly, the plethora of peptides generated from the activity of endogenous proteases on protein shed from different parts of tissues also find their way to urine. Some of these sequences possess antimicrobial activity due to their amino acid composition.

Simultaneous Fluorimetric Determination of On-line Preconcentrated HANs, DCAD and TCAD by Using RPLC with a Postcolumn Derivatization System

  • Jung, Sung-Woon;Choi, Yong-Wook
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1783-1790
    • /
    • 2013
  • A simultaneous analytical method has been developed for the fluorimetric determination of haloacetonitriles (HANs) [dichloroacetonitrile (DCAN), trichloroacetonitrile (TCAN), dibromoacetonitrile (DBAN), haloacetamides [dichloroacetamide (DCAD), and trichloroacetamde (TCAD)] in drinking water by using the combined on-line perconcentration/reversed phase liquid chromatography (RPLC)-postcolumn detection system. This on-line perconcentration system was achieved by employing a precolumn packed with a commercial solid phase extraction (SPE) sorbent for the enrichment and purification of the target analytes. The haloacetonitriles and haloacetamides were separated on CN analytical column in a 7.5% methanol-0.02 M phosphate buffered mobile phase at pH 3. The column effluents were reacted with postcolumn reagents of ophthaldialdehyde (OPA) and sulfite ion at pH 11.5, to produce a highly fluorescent isoindole fluorophore, which were measured with a fluorescence detector. Under the optimized conditions for RPLC and the postcolumn derivatization system all of the coefficient of determination of the standard calibration curves for the target analytes were over 0.99 and had a linear range from 5 to 100 ${\mu}g/L$. The detection limits showed 1.6 ${\mu}g/L$ for DCAD, 0.1 ${\mu}g/L$ for TCAD, 0.6 ${\mu}g/L$ for DCAN, 1.6 ${\mu}g/L$ for TCAN and 1 ${\mu}g/L$ for DBAN, and the recoveries were ranged from 64 to 99% except for DCAD with precisions less than 4.9% in distilled water, and from 72(${\pm}4%$) to 116%(${\pm}2%$) in tap water.

Analysis of Agrochemical Residues in Tobacco Using Solid Phase Microextraction-Gas Chromatography with Different Mass Spectrometric Techniques

  • Lee, Jeong-Min;Jang, Gi-Chul;Kim, Hyo-Keun;Hwang, Geon-Joong
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.30 no.2
    • /
    • pp.117-124
    • /
    • 2008
  • A solid phase microextraction (SPME) method in combination with gas chromatography/mass spectrometric techniques was used for the extraction and quantification of 12 selected agrochemical residues in tobacco. The parameters such as the type of SPME fiber, adsorption/desorption time and the extraction temperature affecting the precision and accuracy of the SPME method were investigated and optimized. Among three types of fibers investigated, polyacrylate (PA), polydimethylsiloxane (PDMS) and polydimethylsiloxane-divinylbenzene (PDMS-DVB), PDMS fiber was selected for the extractions of the agrochemicals. The SPME device was automated and on-line coupled to a gas chromatograph with a mass spectrometer. Mass spectrometry (MS) was used and two different instruments, a quadrupole MS and triple quadrupole MS-MS mode, were compared. The performances of the two GC-MS instruments were comparable in terms of linearity (in the range of 0.01$\sim$0.5 $\mu$g/mL) and sensitivity (limits of detection were in the low ng/mL range). The triple quadrupole MS-MS instrument gave better precision than that of quadrupole MS system, but generally the relative standard deviations for replicates were acceptable for both instruments (< 15%). The LODs was fully satisfied the requirements of the CORESTA GRL. Recoveries of 12 selected agrochemicals in tobacco yielded more than 80% and reproducibility was found to be better than 10% RSD so that SPME procedure could be applied to the quantitative analysis of agrochemical residues in tobacco.

Simultaneous determination of carbaryl & organophosphorous pesticides in water by liquid chromatography-tandem mass spectrometry (LC/MS/MS를 이용한 수중의 카바릴·유기인계 농약 동시분석)

  • Park, Keun-Young;Shin, Jung-Chul;Pyo, Dongjin
    • Analytical Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.39-46
    • /
    • 2018
  • Carbaryl and seven organophosphorous pesticides were analyzed simultaneously using on-line solid phase extraction (on-line SPE) coupled with liquid chromatography tandem mass spectrometry (LC/MS/MS). The target pesticides are Carbaryl, Methyl demeton, Fenitrothion, Malathion, Parathion, Phenthoate, Diazinon, and EPN. This method includes the direct injection of $500{\mu}L$ in the water sample, a 15 min separation period using a rapid resolution liquid chromatography system with on-line SPE, and detection through electrospray ionization (ESI) positive mode. The percentage of recovery of all pesticides ranged from 85.3 % to 100 %. This method showed an accuracy of ${\geq}90.0%$, possessing limits of detection and quantification within 0.05 to $0.28{\mu}g/L$ and 0.16 to $0.89{\mu}g/L$, respectively. The correlation coefficients (r) for the calibration curves within a range of 0.5 to $8.0{\mu}g/L$ were higher than 0.99. The evaluation results showed the efficacy of the method for all contents, and no pesticides were detected in the water quality sample.

A Study on the Development of Analytical Methods and Behaviors of Environmental Pollutants(III) : On-Line System for Preconcentration and Separation of Trace Phenols by HPLC (환경 오염물질의 정량법 개발과 거동에 관한 연구(III) : 미량 페놀류의 HPLC 정량을 위한 온 라인 농축)

  • Lee, Dai Woon;Kim, Jin Young;Park, Young Hun;Moon, Myeong Hee
    • Analytical Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.33-39
    • /
    • 1994
  • The purpose on this study was to develop a new improved chromatographic method for determination of trace phenols from environmental waste water. The research was carried out with selected 8 phenols, and solid-phase extraction was employed as sample pretreatment method. The coupling of XAD-4 and Dowex $1{\times}8$ resin as preconcentration column increased the selectivities toward interferences coexisted in matrix. Automation was accomplished with on-line process of pretreatment and HPLC system. After elution of sample through XAD-4 column, phenols were adsorbed by dispersion force, then displaced from it by ACN basified, simultaneously and selectively readsorbed via anion exchange on Dowex $1{\times}8$. Dowex $1{\times}8$ column was washed by water. Phenols readsorbed were removed from Dowex $1{\times}8$ column by a minimum volumn of methanol containing HCl. Each pretreatment step was connected by switching valves and the eluate was directly on-line injected to obtain fast and reliable results into the HPLC. Recovery of phenols was greater than 90%. To examine utility of this method, analysis of phenols from laboratory waste water sample which was added some organic pollutants to find with phenols on environmental waste water were also accomplished without their interference effects.

  • PDF