A New Approach to On-Line Monitoring Device for ZnO Surge Arresters

  • Lee Bok-Hee;Gil Hyoung-Jun;Kang Sung-Man
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권3호
    • /
    • pp.131-137
    • /
    • 2005
  • This paper describes a new approach to the algorithm and fundamental characteristics of the device for monitoring the leakage currents flowing through zinc oxide (ZnO) surge arresters. In order to obtain a technique for a new on-line monitoring device that can be used in the deterioration diagnosis of ZnO surge arresters, the new algorithm and on-line leakage current detection device for extracting the resistive and capacitive currents using the phase shift addition method were proposed. The computer-based on-line monitoring device can sense accurately the power frequency leakage currents flowing through ZnO surge arresters. The on-line leakage current monitoring device of ZnO surge arresters proposed in this work has the high sensitivity compared to the third harmonic leakage current detection devices. As a consequence, it was found that the proposed leakage current monitoring device would be useful for forecasting the defects and degradation of ZnO surge arresters.

인덕턴스 측정에 의한 윤활유 내 자성입자 정량적 평가 (Monitoring Inductance Change to Quantitatively Analyze Magnetic Wear Debris in Lubricating Oil)

  • 구희조;안효석
    • Tribology and Lubricants
    • /
    • 제32권6호
    • /
    • pp.189-194
    • /
    • 2016
  • Wear debris in lubricating oil can be indicative of potential damage to mechanical parts in rotating and reciprocating machinery. Therefore, on-line or in-line monitoring of lubricating components in machinery is of great importance. This work presents a device based on inductive measurement of lubricating oil to detect magnetic wear particles in a tested volume. The circuit in the device consists of Maxwell Bridge and LVDT to measure inductance differences between pure and contaminated oil. The device detects the passage of ferrous particles by monitoring inductance change in a coil. The sensing principle is initially demonstrated at the microscale using a solenoid. The device is then tested using iron particles ranging from $50{\mu}m$ to $100{\mu}m$, which are often found in severely worn mechanical components. The test results show that the device is capable of detecting and distinguishing ferrous particles in lubricating oil. The design concept demonstrated here can be extended to an in-line monitoring device for real-time monitoring of ferrous debris particles. A simulation using the CST code is performed to better understand the inductive response in the presence of magnetic bodies in the oil. The CST simulation further verifies the effectiveness of inductance measurement for monitoring magnetic particles within a tube.

지지애자의 표면오염 모니터링 기술 및 장치 (Monitoring Technique and Device of Surface Contamination for Line-Post Insulator)

  • 길경석;박대원;정광석;김선재;서동환
    • 한국전기전자재료학회논문지
    • /
    • 제23권5호
    • /
    • pp.413-417
    • /
    • 2010
  • Line to ground faults by deterioration of insulators has frequently occurred in power system, and the main cause is surface contamination of the insulators. The contamination of insulator is analyzed by monitoring the surface leakage current flowing them. The suspension insulator is monitored by installation of a zero-phase current sensor(ZCT), but the line-post insulator is impossible to apply the same method because of its large diameter structure. This paper proposed a detection method of surface leakage current for a line-post insulator, and it can easily be applied to new and/or built insulators. The leakage current is indirectly calculated from the potential difference between the metal electrode attached on the surface of insulator and the ground connector. To evaluate the performance of the proposed method, the leakage current is compared as a function of contamination condition controlled by the density of NaCl solution. The leakage current is proportioned to the density of NaCl solution, and the voltage detected by the electrode showed the same trend. From the experimental results, we designed and fabricated a monitoring device which is composed of a detection electrode, signal converter, microprocessor, and ZigBee, and its measurement range is $10{\mu}A{\sim}5mA$.

전력선 주파수 모니터링을 위한 Intelligent Electronic Device(IED) 플랫폼 (A Power-line Frequency Monitoring Intelligent Electronic Device(IED) Platform)

  • 전현진;이돈진;전준길;장태규
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.1047-1049
    • /
    • 2009
  • This paper presents an intelligent electronic device(IED) platform which is based on a new frequency estimation algorithm. The IED platform features not only the accurate estimation of frequency but also the fast network-based transmisstion of fault data and waveforms. The simulation results show that the proposed frequency estimation algorithm improves convergence speed, and has lower frequency estimation error compared with those of conventional algorithms. The network-based IED is designed to ensure transmission latency being less than 1.0% of sampling interval.

변압기 누설전류 통합 감시장치 (Total monitoring device of leakage current in transformer)

  • 이정은;최홍규;염성배;박형민;유해출;홍성구;신혜영
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.360-363
    • /
    • 2009
  • 변압기 누설전류 통합 감시 장치는 변압기 중성선에 흐르는 누설전류를 검출하여 실시간으로 모니터링이 가능한 장치로, 지정 값 이상의 누설전류가 검출되면 관리자에게 경보함으로써 전기적인 사고를 사전에 예방할 수 있다. 본 논문에서는 변압기 누설전류 통합 감시장치에 대해 설명하고, 국내 현재 설비상황 및 실제 사고 사례를 통해 변압기 누설전류 통합 강시장치의 필요성에 대해 설명하였다.

  • PDF

Softwire Protocol에 기반한 옥내 전력선 통신 장치의 설계 (Design of the residential poorer line communication device based on Softwire Protocol)

  • 조성국;김동성;명관주;윤지훈;권욱현
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(1)
    • /
    • pp.485-488
    • /
    • 2000
  • This paper proposes to design the residential power line communication device using Softwire Protocol, which targets the device with 8bit micro-controller and small-size memory based on low-rate power line communication network or wireless communication network. As a case study, the SCP message specification of air-conditioner that has capability of control and monitoring its status is designed using Softwire Protocol. And, it is described how the device operates sequentially.

  • PDF

Implementation of Wireless PGN Analyzer for ISOBUS network

  • Tumenjargal, Enkhbaatar;Badarch, Luubaatar;Lee, Kangsan;Ham, Woonchul;Doopalam, Enkhzul;Togooch, Amartuvshin
    • 스마트미디어저널
    • /
    • 제4권2호
    • /
    • pp.46-54
    • /
    • 2015
  • Communication between ECUs (Electronic Control Units) in agricultural machineries tends to use IS011783 widely, that is PGN (Parameter Group Number) based communication protocol lays on CAN protocol by altering its identifier part. Messages in line are transferred and received between ECUs according to ISO11783 standard. This paper discusses about design of wireless monitoring system. We used an ARM Cortex-M3 microcontroller embedded development board and marvel8686 wireless module. The wireless ISOBUS monitoring system, attached to communication line, reads messages, interpret them, and display them on the screen in easily comprehendible form. It can be used to generate messages and monitor the traffic on physical bus systems. The monitoring system connected to ECUs, monitor and simulate real traffic of communication and functionality of the ECUs. In order to support our work, we have implemented the monitoring tool. The development consists of two parts: GUI of the application and firmware level programming. Hence the monitoring system is attached to the communication line and equipped by Wi-Fi module; farmer/dispatcher in a farm monitors all messages in communication line on personal computer and smart device.

수직 라인 관측시스템을 이용한 제주 동부 해안대수층에서 해수침투 모니터링 평가 (Saltwater Intrusion Monitoring Evaluation through Automatic Vertical Line Method in a Costal Aquifer of the Eastern Part of Jeju Island)

  • 장호준;하규철;황인욱;김기표;박원배
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제26권3호
    • /
    • pp.1-13
    • /
    • 2021
  • Groundwater monitoring is commonly practiced with real-time sensors placed in several depth spots in aquifer. However, this method only provides monitoring data at the point where the sensors are installed. In this study, we developed a vertical line monitoring system (VLMS) that can provide continuous data of groundwater parameters along the vertical depth. The device was installed in a well located on the coast of the eastern part of Jeju island to monitor electrical conductivity, temperature, salinity, pH, dissolved oxygen, and oxidation-reduction potential over approximately 3 months from September 11 to December 3, 2020. The results indicated that the groundwater levels fluctuated with the tidal change of seawater level, and the upper and lower boundaries of the freshwater and saltwater zone in the groundwater were located at below 16 m and 36 m of mean sea level, respectively. There was a large variation in EC values during the high tide and temperature change was the greatest during flow tide. Although further investigation is needed for improvement of the device to obtain more accurate and reliable data, the device has a potential utility to provide fundamental data to understand the seawater intrusion and transport mechanisms in coastal aquifers.

발효배지의 완충용량의 온라인 측정 및 유기산 생산 추정 (On-line Measurement of Buffer Capacity of a Fermentation medium and Estimation of Organic Aicd Production)

  • 허원;정윤근
    • KSBB Journal
    • /
    • 제13권4호
    • /
    • pp.461-467
    • /
    • 1998
  • A fermentation system was supplemented with a device for the measurement of the durations of alkali pump feeding for automatic pH control and an A/D convertor for precise monitoring of pH value by computer. A software program was developed to measure buffer capacities from the pH signal and the pH control signal during fermentation. By measuring the buffer capacity on-line, levels of acetic acid were estimated by a software sensor using pH signal in a fermentation process of E.coli growing in a minimal medium. The measured values of acetic acid showed correlation to those of estimated by the software sensor. Lacitic acid production was also successfully estimated by the values of buffer capacities measured on-line.

  • PDF

불평형전류 측정에 의한 회전기 열화감시장치 (Deterioration Monitoring Device by Unbalance Current Measurement of Rotating Machines)

  • 박찬용;박대원;류길수;길경석;이강원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.2035-2039
    • /
    • 2008
  • This paper described an on-line condition monitoring device for rotating machines by measurement of unbalance current due to insulation deterioration. The device consists of a zero-phase current transformer (ZCT), a low-noise amplifying circuit, and a microprocessor unit. The prototype device measures current of $500\;{\mu}A\;{\sim}\;30\;mA$ in frequency ranges from 10 Hz to 3 kHz. An application experiment was carried out on 3-phase induction motors and we could measure current changes caused by a short-circuited turn.

  • PDF