• 제목/요약/키워드: On-line monitor

검색결과 383건 처리시간 0.035초

Development of a Monitoring Equipment of Current and Potential on Power Transmission Line for 66kV

  • Nisiyama, Eiji;Kuwanami, Kenshi;Kawano, Mitsunori;Matsuda, Toyonori;Oota, I.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.41-44
    • /
    • 2003
  • We propose portable equipment that monitors current and voltage of high-potential power transmission lines. In the equipment, a current and voltage sensor are attached to an insulator that supports a power transmission line: A clamped to the power line and the detected current signal is transmitted to the ground station by a wireless optical link using transmission line is detected by a high resistance element, zinc oxide (ZnO). That acts as a potential divider between the power line and ground. We make an experimental device for 66kV power line and demonstrate that it can monitor currents proposed equipment is small-sized, light, and inexpensive in comparison with the conventional CT (current transformer) and PT (potential transformer) since it does not require high potential insulators and magnetic cores, further, the equipment is easily installed owing to its small size and its simple structure.

  • PDF

Grounding Line Change of Ronne Ice Shelf, West Antarctica, from 1996 to 2015 Observed by using DDInSAR

  • Han, Soojeong;Han, Hyangsun;Lee, Hoonyol
    • 대한원격탐사학회지
    • /
    • 제34권1호
    • /
    • pp.17-24
    • /
    • 2018
  • Grounding line of a glacier or ice shelf where ice bottom meets the ocean is sensitive to changes in the polar environment. Recent rapid changes of grounding lines have been observed especially in southwestern Antarctica due to global warming. In this study, ERS-1/2 and Sentinel-1A Synthetic Aperture Radar (SAR) image were interferometrically acquired in 1996 and 2015, respectively, to monitor the movement of the grounding line in the western part of Ronne Ice Shelf near the Antarctic peninsula. Double-Differential Interferometric SAR (DDInSAR) technique was applied to remove gravitational flow signal to detect grounding line from the interferometric phase due to the vertical displacement of the tide. The result showed that ERS-1/2 grounding lines are almost consistent with those from Rignot et al. (2011) which used the similar dataset, confirming the credibility of the data processing. The comparison of ERS-1/2 and Sentinle-1A DDInSAR images showed a grounding line retreat of $1.0{\pm}0.1km$ from 1996 to 2015. It is also proved that the grounding lines based on the 2004 MODIS Mosaic of Antarctica (MOA) images and digital elevation model searching for ice plain near coastal area (Scambos et al., 2017), is not accurate enough especially where there is a ice plain with no tidal motion.

PLM 통신기반 선박용 LMS 구현 (Implementation of Lamp Monitoring System(LMS) for Ship Based on PLM)

  • 임현정;양현숙;김건우;백영진;김윤식;이성근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권2호
    • /
    • pp.182-189
    • /
    • 2007
  • This paper describes the implementation of control and monitoring system of ship's lamps at local area using power line communication method, power line modem(PLM). We design modem, microprocessor interface for electric power control by frequency control and analog to digital signal conversion, lamp device. PLM communication is very economical using existing electric power line unlike RS-232, RS-485 communications. We verify and confirm by experimental work that control and monitor lamp system for ship by an PLM communication.

Real-Time Measurement of Fry in the Cultivation Field Using a Line-Image Sensora

  • Ishimatsu, T.;Kawasue, K.;Kumon, T.;Ochiai, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국제학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.822-825
    • /
    • 1988
  • In this paper, we present a system which enables a real-time measurement of the number and also the body length of the fry (baby fish) using a line image sensor. Here, we consider a situation that fry are transported from a pond to another, pond through a pipe. At one position of the pipe a transparent rectanglar channel is mounted. The images of the fry, which run through this rectanglar channel, are detected by a line image sensor. The image signals are digitized to binary ones and the contour of the fry are detected. After that, a real-time image analysis is executed with a digital signal processor. Labeling program analyses the connection of every pixel. The results are transfered to a personal computer and displayed on the online monitor graphically.

  • PDF

활성탄섬유를 이용한 확산포집기의 공기 중 유기용제 포집효율에 관한 연구 (The Sampling Efficiencies of Volatile Organic Compounds(VOCs) to the Diffusive Monitor with Activated Carbon Fiber)

  • 변상훈;박천재;오세민;이창하
    • 한국산업보건학회지
    • /
    • 제6권2호
    • /
    • pp.187-201
    • /
    • 1996
  • This study was to evaluate the efficiency of diffusive monitor using activated carbon fiber(ACF, KF-1500) in measuring airborne organic solvents. The following characteristics were identified and studied as critical to the performance of diffusive monitor; recovery, sampling rate, face velocity, reverse diffusion and storage stability. For the evaluation of the performance of this monitor, MIBK, PCE, toluene were used as organic solvents. In the sampling rate experiments, eight kinds of solvents (n-hexane, MEK, DIBK, MCF, TCE, CB, xylene, cumene) as well as the above solvents were used. The results were as follows: 1. The desorption efficiencies(DE's) of ACF diffusive monitor ranged from 83 % to 101 %. In contrast, those of coconut shell charcoal ranged from 78 % to 102 %. Especially, the DE's of ACF for the polar solvents such as MEK were superior to those of charcoal. 2. Experimental sampling rates on ACF were average 42ml/min(37-46ml/min) for 11 organic solvents at $24{\pm}2^{\circ}C$, $50{\pm}5%RH$. However ideal sampling rates(DA/L) were 33 % higher than experimental sampling rates. 3. The initial response(15~16 min) of the testing monitor was 2 times higher than the actual concentration determined by the reference methods at $24{\pm}2^{\circ}C$, $8{\pm}5%RH$ and $80{\pm}5%RH$. Within 1 hours, the curve reached a linear horizontal line at low humidity condition. But sampling efficiencies decreased with respect to time at high humidity condition. And sampling efficiencies were higher at high humidity condition than low humidity condition for MIBK. 4. At very low velocity (less than 0.02 m/sec), the concentration of ACF diffusive monitor were poorly estimated. But ACF diffusive monitor were not affected at higher velocity(0.2 m/sec-0.6 m/sec). 5. There was no significant reverse diffusion when the ACF monitors were exposed to clean air for 2 hours after being exposed for 2 hours at the level of 1 TLV. 6. There was no significant sample loss during 3 weeks of storage at room temperature and 5 weeks of storage at refrigeration.

  • PDF

Development of a 30-in. wide-QXGA+ TFT-LCD for High-Information-Content Displays

  • Choi, H.C.;Hong, S.G.;Lim, B.H.;Lee, S.W.;Yeo, S.D.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.19-22
    • /
    • 2004
  • A 30-inch WQXGA+ TFT-LCD Monitor has been developed based on in-plane switching mode with multi-domain. This product adopts Cu electrode which, in spite of low resistivity, was not applied to TFT LCD products because of productivity and reliability problems etc. This low resistivity material makes it possible to clear the problem caused by line delay in such high resolution TFT-LCDs. As a results of successful adoption of innovative materials and technologies, our world's largest TFT-LCD Monitor has best performance for high information display.

  • PDF

전화선을 이용한 전압 감시 시스템에 관한 연구 (A study of the voltage monitoring system with dial-up telephones)

  • 손명수;남궁도;송병권;윤갑구;장미혜
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.107-111
    • /
    • 1996
  • In this paper, the voltage monitoring system is designed to monitor the outage and voltage fluctuation by using a dial-up telephone. The master station receives tire outage signal-such as interruption and voltage sag etc. - from the remote in on-line of real-time. The SCC(Serial Communication Controller) is adapted to monitor voltages multiple clients(about 256 clients) simultaneously. The voltage fluctuation in a normal range shall be transmitted to the master station, at early morning the clients use the telephone less frequently. The operating system shall be "window 95" and the database is programmed in Visual-basic for a easy analysis of voltage fluctuation.

  • PDF

PCA를 이용한 유전자 재조합 대장균의 ALA 생산공정의 해석

  • 강태형;정상윤;임용식;김춘광;정상욱;이종일
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2003년도 생물공학의 동향(XII)
    • /
    • pp.157-160
    • /
    • 2003
  • ALA is an intermediate in the tetrapyrrole biosynthesis pathway and has extensive applications as a biodegradable herbicide and insecticide as well as medical applications including photodynamic therapy of cancers. For the development of mass production process of ALA it is necessary to on-line monitor some metabolites such as glycine, succinate, LA and ALA. In this study, medium compositions and fermentation conditions were investigated for enhancement of ALA production by recombinant E. coli. A 2-dimensional fluorescence sensor was employed to monitor the bioprocess of ALA production. The monitored data is analyzed using principal component analysis, a powerful tool for multivariate statistical analysis.

  • PDF

스피커 어레이를 이용한 개인용 모니터와 TV 오디오 시스템 (Personal monitor & TV audio system by using speaker array)

  • 이찬희;장지호;박진영;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.638-643
    • /
    • 2007
  • With development of high display quality of TV and Monitor, personal audio system is arising great interest. In this study, we applied a method to make a good bright zone around the user and dark zone to other region by maximizing the ratio of sound energy between the bright and dark zone. We have attempted to use a line speaker array system to localize the sound in our listening zone. It depends on the size of the zone and array parameters, for example, array size, speaker spacing, wave length of sound.

  • PDF

민간항공사의 운항승무원에 영향을 주는 위협관리에 관한 연구 (A study of the threats towards the flight crew)

  • 최진국;김칠영
    • 한국항공운항학회지
    • /
    • 제18권2호
    • /
    • pp.54-59
    • /
    • 2010
  • The flight deck crew must manage complexity during daily flight operations. The Airline may obtain data regarding threats and errors through LOSA(Line Operations Safety Audits) on normal flights as predictive safety tool in Safety Management System of the Airline to actively improve the systems such as SOP(Standard Operation Procedure), training, evaluation and the TEM(Threat and Error Management) for the flight deck crew. The flight deck crew make errors when they fail managing threats. The crew mismanage around ten percent of threats and commit errors. The major mismanaged threats are aircraft malfunction, ATC(Air Traffic Communication), and wether threats. The effective countermeasures of TEM for manageing threats are leadership, workload management, monitor & cross check, Vigilance, communication environment and cooperation of the crew. It is important that organizations must monitor for the hazards of threats and improve system for the safer TEM environments.