• Title/Summary/Keyword: On-line monitor

Search Result 383, Processing Time 0.026 seconds

Development of On line Diagnosis System for Generator (발전기 운전중 종합 진단시스템 개발)

  • Lee, Young-Jun;Kong, Tae-Sik;Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.975-977
    • /
    • 2005
  • The generator on-line diagnosis system has been developed. This system monitor the insulation condition of stator winding by on-line measurements of partial discharge and the shorted-turn condition of rotor winding by on-line measurements of slot leakage flux. Sensor, such as SSC(Stator Slot Coupler) and flux probe are used for generator on-line diagnosis.

  • PDF

On Line Monitoring and Diagnosis Technique for the Array of Photovoltaic Energy System (태양광 발전시스템 전지모듈의 온라인 감시 진단 시스템 개발)

  • Lee, Jong-Pil;Ji, Pyeong-Shik;Byun, Sang-Zoon;Lim, Jae-Yoon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.4
    • /
    • pp.168-172
    • /
    • 2007
  • The global environment deteriorating which originated from using of fossil fuel is an serious problem for human being to solve. The photovoltaic energy has been considered as a solution. In advanced countries, research and development for photovoltaic(PV) energy system is carrying on. Once installed, a PV array requires maintenance and fault diagnosis other than an occasional cleaning. In this research, the proposed system monitor and diagnosis the output of PV array by on-line for maintenance of PV power plant. The validity of proposed system is verified using sample system.

Monitoring of Ship's Emergency Lighting System using PLM(SELP) (PLM을 이용한 선박 비상조명시스템의 모니터링)

  • Lim, Hyun-Jung;Yang, Hyun-Suk;Kim, Kun-Woo;Baek, Young-Jin;Lee, Sung-Geun;Kim, Yoon-Sik
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.105-106
    • /
    • 2006
  • In this paper we describe a driving, control and monitor of ship's emergency lighting system using power line modem.(PLM). Through this paper, experiment confirms that ON-OFF control of multiple SELP, real time transmission and monitor of parameters as to voltage, current, and power values are performed appropriately by PLM communication.

  • PDF

Parking Space Detection based on Camera and LIDAR Sensor Fusion (카메라와 라이다 센서 융합에 기반한 개선된 주차 공간 검출 시스템)

  • Park, Kyujin;Im, Gyubeom;Kim, Minsung;Park, Jaeheung
    • The Journal of Korea Robotics Society
    • /
    • v.14 no.3
    • /
    • pp.170-178
    • /
    • 2019
  • This paper proposes a parking space detection method for autonomous parking by using the Around View Monitor (AVM) image and Light Detection and Ranging (LIDAR) sensor fusion. This method consists of removing obstacles except for the parking line, detecting the parking line, and template matching method to detect the parking space location information in the parking lot. In order to remove the obstacles, we correct and converge LIDAR information considering the distortion phenomenon in AVM image. Based on the assumption that the obstacles are removed, the line filter that reflects the thickness of the parking line and the improved radon transformation are applied to detect the parking line clearly. The parking space location information is detected by applying template matching with the modified parking space template and the detected parking lines are used to return location information of parking space. Finally, we propose a novel parking space detection system that returns relative distance and relative angle from the current vehicle to the parking space.

A Java-based Performance Monitor for Networked Computer (네트워크 컴퓨터를 위한 자바 기반의 성능감시기)

  • Kim, Bong-Jun;Kim, Dong-Ho;Hwang, Seog-Chan;Kim, Myung-Ho;Choi, Jae-Young
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.27 no.2
    • /
    • pp.160-168
    • /
    • 2000
  • In this paper, we present a performance monitor to trace and evaluate the performance of programs running on networked computers. The performance monitor of the JaNeC is online/batch as well as event/time driven. Since it is implemented with the Java programming language, it provides us with high portability among heterogeneous computer systems, and friendly graphical user interface. This performance monitor consists of various views such as 'Task/Event Filter' and 'TimeLine', 'Task View', 'Task Hoistory', 'Message Passing View', 'Host Cpu View', which allow the user to easily analyze event and time during the program execution.

  • PDF

The Development of Optical Fiber Line Operation and Monitor System (광선로 운용감시 시스팀 개발)

  • Kim, Seong-Il;Choi, Shin-Ho;Park, Kap-Seok;Jang, Eun-Sang;Lee, Byeong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2492-2494
    • /
    • 1998
  • Recently the optical fiber lines have been widely deployed in the trunk lines and digital data service network. The unexpected failures of optical fiber lines by natural disasters and road construction work have increased rear by rear and the number of damaged telecommunication lines per failures is on increasing. In the meantime, it takes long time to recover the optical fiber lines failures. So, it is important to maintain and monitor the status of optical fiber lines for prevention of optical fiber lines failures. Therefore, KT(Korea Telecom) needs efficient and automatic maintenance system to operate and monitor the optical fiber lines. FLOMS(Fiber Line Operation and Monitor System) had been developed in '96 and pilot system was installed at telephone offices in '97. This paper describes the FLOMS which carries out the functions of efficient maintenance and supports for monitoring optical fiber lines and managing facilities in optical fiber lines.

  • PDF

Performance and Development of Life Sympathy Policy (생활공감정책의 운영성과와 발전방안)

  • Cho, Seok-Joo;Park, Jong-Gwan
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.12
    • /
    • pp.753-763
    • /
    • 2011
  • The goal of this study is to analyze the problem and performance of life sympathy policy and to present development plan. For this, literature, and empirical research were performed. The analysis showed the problem of life sympathy policy in the following manner. That is the confusion of the mix of department, the lack of publicity, the uncertain of persistence and the lack identity of the monitor, the absence a unified operating instructions on the monitor, the insufficient to activities and operations housewife monitors etc. To vitalize life sympathy policy and operational needs of aspects of the institutional and the activation. First, The task of activation of the institutional challenge is to modify the related law, strengthen the organization, strengthen the personnel, expand the scope of participation monitors. The improvement of the operational aspects of the policy include strengthening integration and connectivity, the construction of policy promotion environment that reinforce feedback and outcome of life sympathy policy, And the energization of on-line activities needs the reinforcement of the operating system, etc. Through the activation of the sector policy, the application of the idea of housewives, and the participation of government policies will be a lot of contribution to the development of South Korea in the 21st century.

Implementation of Wireless PGN Analyzer for ISOBUS network

  • Tumenjargal, Enkhbaatar;Badarch, Luubaatar;Lee, Kangsan;Ham, Woonchul;Doopalam, Enkhzul;Togooch, Amartuvshin
    • Smart Media Journal
    • /
    • v.4 no.2
    • /
    • pp.46-54
    • /
    • 2015
  • Communication between ECUs (Electronic Control Units) in agricultural machineries tends to use IS011783 widely, that is PGN (Parameter Group Number) based communication protocol lays on CAN protocol by altering its identifier part. Messages in line are transferred and received between ECUs according to ISO11783 standard. This paper discusses about design of wireless monitoring system. We used an ARM Cortex-M3 microcontroller embedded development board and marvel8686 wireless module. The wireless ISOBUS monitoring system, attached to communication line, reads messages, interpret them, and display them on the screen in easily comprehendible form. It can be used to generate messages and monitor the traffic on physical bus systems. The monitoring system connected to ECUs, monitor and simulate real traffic of communication and functionality of the ECUs. In order to support our work, we have implemented the monitoring tool. The development consists of two parts: GUI of the application and firmware level programming. Hence the monitoring system is attached to the communication line and equipped by Wi-Fi module; farmer/dispatcher in a farm monitors all messages in communication line on personal computer and smart device.

Optimum Coagulation of Water Treatment Plant using On-line Floc Monitoring System (정수장 응집제주입 최적화를 위한 플럭 모니터링)

  • Hwang, Hwando;Lim, Sangho;Sung, Kyujong;Han, Youngjin;Kim, Youngbeom;Kwak, Jongwoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.4
    • /
    • pp.397-406
    • /
    • 2009
  • This study was conducted to monitor the floc sizes forming in the mixing zone in the water treatment plant. The dosing amount of poly aluminium chloride(PAC) was determined by particle dispersion analyzer(iPDA) in the lab and field scale test. During a field test period, PAC coagulant was used and the raw water was taken from Nakdong river. PAC wad diluted to activate the coagulant, leading to bring the more homogeneous dispersion in the shorter time. To monitor the floc sizes, the unit of floc size index(FSI) was used. With increasing of raw water turbidity, FSI value was increased. Also, the increased dosing amount of PAC brought the increased FSI and with overdosing of coagulant was in turn decreased. When the PAC was fed into the raw water after dilution in a field scale test, the width of FSI was narrower compared with the feeding of the mother liquor of PAC, implying that the formed flocs are denser and more uniform sizes. The width of FSI in average was varied on depending on the basicity of coagulant. Also, dF value, fractal dimension was evalued with the different coagulants, showing from 2.01 to 2.03. On-line floc monitor was effective for the optimal dosing in the drinking water plant.

Methodology Development of On-line Monitor for Soluble Components in Aerosols (미세 먼지의 수용성 성분 On-line 측정 장치 개발에 개발에 관한 연구)

  • 홍상범;김대성;이규원;이재훈
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.333-334
    • /
    • 2003
  • 미세 먼지의 수용성 성분에 대한 On-line 방식의 측정 기기 개발의 필요성은 다음과 같다.첫째, 대기오염문제의 근본적인 물리, 화학적인 현상의 이해를 강화하는 데 있다. 미세 먼지의 화학적인 조성과 농도는 발생원에서 발생한 이후 급격하게 변화하는 대기환경 조건에서 빠른 변환( Chemical transformation )을 경험하는 데 현재의 필터 포집 측정 방식은 시간 분해도(time resolution)가 길어 현재의 측정 결과들은 정확한 미세 먼지의 화학적인 특성을 반영하기가 어렵다. (중략)

  • PDF