• 제목/요약/키워드: On-line Condition Monitoring

검색결과 174건 처리시간 0.035초

Zigbee통신을 이용한 전력변환기기의 DC Bus 커패시터의 온라인 원격 고장진단 시스템 (On-line Remote Diagnosis System for DC Bus Capacitor of Power Converters Using Zigbee Communication)

  • 정완섭;손진근
    • 전기학회논문지P
    • /
    • 제64권1호
    • /
    • pp.29-34
    • /
    • 2015
  • DC bus electrolytic capacitors are used in variety of equipments as smoothing element of the power converters because it has high capacitance for its size and low price. It is responsible for frequent breakdowns of many static converters and inverter drive systems. Therefore it is important to diagnosis monitoring the condition of an electrolytic capacitor in real-time to predict the failure of power converter. In this paper, the on-line remote diagnosis monitoring system for DC BUS electrolytic capacitors of power converter using low-cost type Zigbee communication modules is developed. To estimate the health status of the capacitor, the equivalent series resistor(ESR) of the component has to be determined. The capacitor ESR is estimated by using RMS computation using AC coupling method of DC link ripple voltage/current. The Zigbee communication-based experimental results show that the proposed remote DC capacitor diagnosis monitoring system can be applied to DC/DC converter and UPS successfully.

고출력 디젤 엔진의 On-Line 마모상태진단 기술 적용을 위한 기초연구 (A Feasibility Study for Application of On-Line Wear Condition Monitoring Technique to the High-powered Diesel Engine)

  • 윤민호;정동윤;공호성
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1997년도 제26회 추계학술대회
    • /
    • pp.59-65
    • /
    • 1997
  • The calibration of O.M.D is carried out experimentally and is analysed theoretically. O.M.D experimentally measures the change in optical density of artificially contaminated oil which contains Fe powder of 5, 10, 20, 30, 40, 50, 70, 100, 200 ppm. The change in optical density, D$_1$ means the logarithmic transmittance of I$_0$ over $I_1 D_2$ denotes the logarithmic transmittance I$_2$ over I$_1$ on electromagnetic force which arranges the ferrous particles along the line of magnetic force. The theoretical D$_1$ which increases linearly as increasing Fe concentrations, is analysed by light attenuation theory. The difference between theoretical D$_1$ and experimental D$_1$ is due to the attenuation of micro bubbles and the agglomeration of fine particles in the sample oil. The calibrated O.M.D is applied to the sample oil from the high-powered diesel engine. Also the results are compared with those out of the off-line techniques such as JOAP and ICP.

  • PDF

환경대기 중 유해성 VOC에 대한 자동연속 측정방법의 성능 최적화에 관한 연구 (A Study on the Performance Optimization of a Continuous Monitoring Method for Hazardous VOCs in the Ambient Atmosphere)

  • 손은성;서영교;이동현;이민도;한진석;백성옥
    • 한국대기환경학회지
    • /
    • 제25권6호
    • /
    • pp.523-538
    • /
    • 2009
  • Recently, there has been a keen demand for real-time automatic monitoring of VOCs not only in Korea but other developed countries. We carried out this study to evaluate and to optimize the performance of a continuous automatic monitoring system for hazardous VOCs (HVOCs) in the ambient atmosphere, using an on-line GC system. The online system normally consisted of a Nafion dryer prior to a cold trap of an automatic thermal desorption apparatus and a GC system equipped with two detectors, i.e. PID and ECD. Preliminary tests conducted to check out any contamination of the system revealed an evidence of significant artifact formation of benzene, and it was found that the Nafion dryer (even brand new one) is the source of the benzene artifact. Thus, all the subsequent experiments in this study was carried out inevitably by removing the Nafion dryer. The on-line GC method was investigated with a variety of QC/QA performance criteria such as repeatability, linearity, lower detection limits, and accuracy. In order to find out the best operating condition for the on-line GC system, three different types (in terms of adsorption strength) of cold trap combinations were tested, i.e. (i) Tenax-TA and Carbopack-B combination (weak and hydrophobic); (ii) Tenax-TA, Carbopack-X and Carboxen-1000 combination (strong and hydrophilic); and (iii) Tenax-TA and Carbopack-X combination (medium and hydrophobic/hydrophilic). The USEPA TO-17 manual method was selected as a reference method to evaluate the performance of the on-line method. A series of experiments revealed that the system performance was superior to others when a cold trap packed with hydrophilic adsorbents (Tenax-TA/Carbopack-X/Carboxen-1000 combination) was used and operated at $25^{\circ}C$. However, the system with a cold trap packed with a combination of Tenax-TA and Carbopack-X is more recommended for field applications since the carboxen-1000 adsorbent is too sensitive to water vapor, and hence the performance of the system might be very unstable to humid samples or during rainy days. Furthermore, the precision and accuracy criteria of the Tenax-TA/ Carbopack-X combination were generally compatible with the triple adsorbents cold trap. The continuous automatic monitoring method is, thus, considered very useful to real-time monitoring to understand the variations of VOCs concentrations in ambient air, as it adopts much simpler procedures in sampling, analysis, and data integration steps than manual monitoring methods. However, it should be noted that there is a high possibility of benzene artifacts formation through the Nafion dryer, which is often installed to remove water vapor in air samples before being adsorbed onto the cold trap. Therefore, if a Nafion dryer is used in any studies of monitoring VOCs, the benzene contamination should be carefully examined before carrying out obtaining the data.

지지애자의 표면오염 모니터링 기술 및 장치 (Monitoring Technique and Device of Surface Contamination for Line-Post Insulator)

  • 길경석;박대원;정광석;김선재;서동환
    • 한국전기전자재료학회논문지
    • /
    • 제23권5호
    • /
    • pp.413-417
    • /
    • 2010
  • Line to ground faults by deterioration of insulators has frequently occurred in power system, and the main cause is surface contamination of the insulators. The contamination of insulator is analyzed by monitoring the surface leakage current flowing them. The suspension insulator is monitored by installation of a zero-phase current sensor(ZCT), but the line-post insulator is impossible to apply the same method because of its large diameter structure. This paper proposed a detection method of surface leakage current for a line-post insulator, and it can easily be applied to new and/or built insulators. The leakage current is indirectly calculated from the potential difference between the metal electrode attached on the surface of insulator and the ground connector. To evaluate the performance of the proposed method, the leakage current is compared as a function of contamination condition controlled by the density of NaCl solution. The leakage current is proportioned to the density of NaCl solution, and the voltage detected by the electrode showed the same trend. From the experimental results, we designed and fabricated a monitoring device which is composed of a detection electrode, signal converter, microprocessor, and ZigBee, and its measurement range is $10{\mu}A{\sim}5mA$.

지적복합재료를 이용한 온라인 모니터링시스템 개발 (Development of On-Line Monitoring System using Smart material)

  • 이진경;박영철;이상필;박이현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.67-71
    • /
    • 2003
  • A hot press method was used to create the optimal fabrication condition for a Shape Memory Alloy(SMA) composite. The bonding strength between the matrix and the reinforcement within the SMA composite by the hot press method was more increased by cold rolling. In this study, the objective was to develop an on-line monitoring system in order to prevent the crack initiation and propagation by shape memory effect in SMA composite. Shape memory effect was used to prevent the SMA composite from crack propagation. For this system an optimal AE parameter should be determined according to the degree of damage and crack initiation. When the SMA composite was heated by the plate heater attached at the composite, the propagating cracks could be controlled by the compressive force of SMA.

  • PDF

지중 금속구조물의 전기방식 원격감시시스템 개발 (The development of On-Line Cathodic Protection Monitoring System)

  • 임헌호;정성우;하희천
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 춘계학술대회 논문집
    • /
    • pp.213-218
    • /
    • 2001
  • These days, corrosion condition of a underground objects is measured by the electric potential between the subject and ground. But this method is implemented by means of manual work with analog voltmeter, which is uneconomic and inefficient. So, We developed real-time On-Line cathodic protection monitoring system that is able to detect corrosion potential conditions of metal objects or various steel structures in the ground continuously, display them with the graphic screen, construct a database, and analyze them simultaneously. Since the data of corrosion and corrosion protection of all underground objects is processed automatically, not manually in this system, It is possible to reduce the manipulated error, and perform precise safety management, maintenance and inspection. As as result, this system can not only guarantee long-life operation, reduction of manpower and cost, but prevent large accidents in advance.

  • PDF

Development of real-time monitoring system using wired and wireless networks ina full-scale ship

  • Paik, Bu-Geun;Cho, Seong-Rak;Park, Beom-Jin;Lee, Dong-Kon;Bae, Byung-Dueg
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제2권3호
    • /
    • pp.132-138
    • /
    • 2010
  • In the present study, the real-time monitoring system is developed based on the wireless sensor network (WSN) and power line communication (PLC) employed in the 3,000-ton-class training ship. The WSN consists of sensor nodes, router, gateway and middleware. The PLC is composed of power lines, modems, Ethernet gateway and phase-coupler. The basic tests show that the ship has rather good environments for the wired and wireless communications. The developed real-time monitoring system is applied to recognize the thermal environments of main-engine room and one cabin in the ship. The main-engine room has lots of heat sources and needs careful monitoring to satisfy safe operation condition or detect any human errors beforehand. The monitoring is performed in two regions near the turbocharger and cascade tank, considered as heat sources. The cabin on the second deck is selected to monitor the thermal environments because it is close to the heat source of main engine. The monitoring results of the cabin show the thermal environment is varied by the human activity. The real-time monitoring for the thermal environment would be useful for the planning of the ventilation strategy based on the traces of the human activity against inconvenient thermal environments as well as the recognizing the temperature itself in each cabin.

연삭 공정의 연속 진단을 위한 모니터링에 관한 연구 (A Study on the Monitoring Technology for the Continuous Detection of Grinding Process)

  • 강재훈
    • 한국생산제조학회지
    • /
    • 제8권1호
    • /
    • pp.74-80
    • /
    • 1999
  • Recently, manufacturing work has been transformed to small scale production form with various types to act up to user's expectation from mass production with a little items required in the past. Then FMS using NC type machinaries has been applied actively also in domestic manufacturing line to meet thus tendency, but there are many machining troubles occured during work process not be settled yet. Nowdays high efficiently has been required no less than high precision in grinding work for the improvement of productivity. In this study, to represent more advance FMS can be adapted to thus situation In-process type monitoring method using AE and Current sensors is suggested to investigate the machining condition in grinding process. As results form this experimental study, it is recognized well that grinding conditions and dressing point of in time cab be estimated effectively using monitoring method suggested. Furthermore, surface shape of grinding wheel on voluntary point of in time can be predicted indirectly through the observation and comparison of AE signal waveform obtained as performance of continuous dressing work.

  • PDF

광파이버 누수센싱 시스템 개발에 관한 연구 (A Study on the Development of Optical-Fiber Water Leakage Sensing System)

  • 김영복
    • 동력기계공학회지
    • /
    • 제16권6호
    • /
    • pp.86-91
    • /
    • 2012
  • A multi purpose environmental monitoring system has been developed as a commercially available standard using the techniques which are FBG(Fiber Bragg Grating), Hetero-core spliced fiber optic sensor and etc, for the purposes of monitoring large scaled structures and preserving natural environments. The monitoring system has been tested and evaluated in a possible outdoor condition in view of the full scaled operation at actual sites to be monitored. Additionally, the developed systems in the previous works conveniently provided us with various options of sensor modules intended for monitoring such physical quantities as displacement, distortion, pressure, binary states, and liquid adhesion. In this paper, we extend the previous results to a water leakage detection problem and develop a sensing system as a result. By the experimental study, it is verified that multi-point leakage detection is possible using single line optical fiber.

온-라인 모니터링 시스템 개발에 관한 연구 (Development of on-line Monitoring and Controlling System)

  • 안동순;박영만;이광호
    • 한국컴퓨터정보학회논문지
    • /
    • 제11권4호
    • /
    • pp.299-304
    • /
    • 2006
  • 산업현장의 기계장치나 실내 외 그리고 해양 등과 같은 주위 환경의 데이터를 원거리의 중앙 컴퓨터에 전송하여 그 상태를 확인하여 해석하고, 해석된 데이터를 바탕으로 이상 유무 등을 판별하여 시스템의 최적 동작을 위한 시스템 명령 등을 Network나 유 무선 통신을 이용하여 전달하는 온-라인 모니터링 시스템이다. 본 연구는 온-라인 모니터링 시스템을 개발하기 위하여 염산 수조의 온도를 원격지의 중앙 컴퓨터에서 제어하는 시스템으로써 모니터링부 무선송신부, 온도콘트롤부로 이루어진 실험 장치를 구성하였다. 본 시스템을 응용하면 재난 재해방지 시스템, 경보 시스템과 같은 USN(Ubiquitous Sensor Network)시스템에 적용이 가능하다.

  • PDF