• 제목/요약/키워드: On-device analyzer

검색결과 133건 처리시간 0.025초

Polymeric Precursor법에 의한 LaMeO3 (Me = Cr, Co)의 제조 및 NOx 가스 검지 특성 (Fabrication and NOx Gas Sensing Properties of LaMeO3 (Me = Cr, Co) by Polymeric Precursor Method)

  • 이영성;;송정환
    • 한국재료학회지
    • /
    • 제21권8호
    • /
    • pp.468-475
    • /
    • 2011
  • [ $LaMeO_3$ ](Me = Cr, Co) powders were prepared using the polymeric precursor method. The effects of the chelating agent and the polymeric additive on the synthesis of the $LaMeO_3$ perovskite were studied. The samples were synthesized using ethylene glycol (EG) as the solvent, acetyl acetone (AcAc) as the chelating agent, and polyvinylpyrrolidone (PVP) as the polymer additive. The thermal decomposition behavior of the precursor powder was characterized using a thermal analysis (TG-DTA). The crystallization and particle sizes of the $LaMeO_3$ powders were investigated via powder X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM), and particle size analyzer, respectively. The as-prepared precursor primarily has $LaMeO_3$ at the optimum condition, i.e. for a molar ratio of both metal-source (a : a) : EG (80a : 80a) : AcAc (8a) inclusive of 1 wt% PVP. When the as-prepared precursor was calcined at $700^{\circ}C$, only a single phase was observed to correspond with the orthorhombic structure of $LaCrO_3$ and the rhombohedral structure of $LaCoO_3$. A solid-electrolyte impedance-metric sensor device composed of $Li_{1.5}Al_{0.5}Ti_{1.5}(PO_4)_3$ as a transducer and $LaMeO_3$ as a receptor has been systematically investigated for the detection of NOx in the range of 20 to 250 ppm at $400^{\circ}C$. The sensor responses were able to divide the component between resistance and capacitance. The impedance-metric sensor for the NO showed higher sensitivity compared with $NO_2$. The responses of the impedance-metric sensor device showed dependence on each value of the NOx concentration.

고체절연체표면의 오염상태에 따른 방전현상과 방사전자파의 주파수 특성 (The Frequency Characteristics of Electromagnetic Waves and Discharge Phenomena Caused by Polluted Condition of Solide Insulator Surface)

  • 김충년;박원주;이광식;이동인;김인식
    • 조명전기설비학회논문지
    • /
    • 제15권4호
    • /
    • pp.43-50
    • /
    • 2001
  • 본 논문은 구대구전극 사이에 고체절연체와 화염을 배치하여 방전시 절연체표면에서 발생되는 연면방전광과 화염의 변화를 CCD(Charged Coupled Device) 카메라로 관측하였으며, 방전시 발생되는 방사전자파는 스펙트럼 분석기와 바이코니칼 안테나를 이용하여 측정하였다. 인가전압 증가에 따른 고체절연체 표면에서 발생되는 연면 방전광은 커졌으며, 화염의 크기는 작아지는 것을 확인하였다. 또한 절연체표면 오염시와 화염시에는 전압강하에 의한 전압왜곡현상이 나타났다. 방사전자파의 전계세기는 절연체표면 무오염시에는 오염시보다 10∼17(dBuV/m), 절연체표면 오염시와 화염시에는 5∼9[dBuV/m]정도 높게 나타났다.

  • PDF

서브마이크론 입자 측정용 저압 임팩터의 설계 및 성능평가 (Design and Performance Evaluation of a Low Pressure Impactor for Sampling Submicron Aerosols)

  • 지준호;조명훈;배귀남;황정호
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.349-358
    • /
    • 2004
  • A low pressure impactor is an impaction device to separate airborne particles into aerodynamic size classes at low pressure condition. We designed a two-stage low-pressure impactor to classify submicron sized environmental aerosols. Performance evaluation was carried out for stages 1 and 2 by using an electrical method. Monodisperse liquid dioctyl sebacate (DOS) particles were generated using evaporation-condensation process followed by electrostatic classification using a DMA (differential mobility analyzer). The test particles were in the range of 0.08∼0.8$\mu\textrm{m}$. For the evaluation of the impactor we used two electrometers; one was connected to the impaction plate of the impactor and the other was to the Faraday cage used as a backup filter. The effect of polydispersity of test aerosols on the performance was investigated. The results showed that the experimental 50-% cutoff diameters at each impactor's operation pressure were 0.53 and 0.187$\mu\textrm{m}$ for stages 1 and stage 2, respectively. The effects of operation pressure on the cutoff diameter and the steepness of collection efficiency curves were also investigated.

역도경기(力道競技)의 운동학적(運動學的) 자세(姿勢)와 근수축(筋收縮) 수준(水準)에 관(關)한 전산분석(電算分析) (A Computerized Analysis of Kinetic Posture and Muscle Contraction during a Weight Lifting Motion)

  • 이면우;장원경;성덕현
    • 대한산업공학회지
    • /
    • 제9권2호
    • /
    • pp.9-25
    • /
    • 1983
  • The purpose of this study was to film up computerized analyses for both kinematic posture(film analysis) and muscle dynamics (EMG) during a weight-lifting motion. (Snatch, Clean and Jerk) Using a motor drive camera (3.5 frames/sec) and a Location Analyzer, motion tracks of 13 landmarks, which were attached to the major joints, during the motion were converted into digital values. At the same time, EMG amplitudes from 11 major muscle groups were recorded. Recorded data were processed via analog/hybrid computer (ADAC 480) and digital computer (PDP 11/44). Landmark locations and EMG amplitude were integrated by a computerized routine. Computer output included graphic reproductions on sepuential dislocations of body segments, center of gravity of body segments and the associated changes on EMG amplitude such as % EMG's of major muscle group during a weight lifting motion. The results strongly suggest that the computerized motion-EMG integration can provide a further working knowledge in selection and in training of workers and athletes. Suggestions for a further study include additional device for velocity measurement, expansion of the link model for biomechanical analysis and other implementations necessary for athletic application.

  • PDF

PRESSURE MODULAION ON MICRO-MACHINED PORT FUEL INJECTOR PERFORMANCE

  • Kim, H.;Im, K.S.;Lai, M.C.
    • International Journal of Automotive Technology
    • /
    • 제5권1호
    • /
    • pp.9-16
    • /
    • 2004
  • An experimental study was carried out to characterize the spray atomization process of micro-machined port fuel injectors with a piezoelectric atomization device, which can generate pressure pulsations through vibration of a piezoelectric transducer. In this study, several types of micro-machined arrays such as 30∼200-microns of hole arrays were tested. Both a dual-stream and a central-port injectors with micro-machined arrays were tested and compared with normal port fuel injectors. The spray visualization was conducted to characterize overall spray structure and phase Doppler particle analyzer (PDPA) system was used to quantify the droplet size and velocity. In addition, the pressure history was recorded by using digitized signal from pressure transducer. The results showed that modulation is effective to the spray atomization for tested injectors and atomization performance depends on injector design factors, orifice sizes, and frequency and power of the modulator. A number of resonance frequencies of the modulator was modified by injector parameters and temperature. In addition, our results suggested that design of sufficient space among holes is critical to avoid droplet coalescence in the multi-hole micro-machined injectors.

제2형 당뇨병 환자에서 피부두겹두께의 측정부위 예측 및 비만지표들 간의 관련성 (Prediction of Suitable Site to Measure Abdominal Skin Fold Thickness and Correlation among Obesity Indicators in Patients with Type 2 Diabetes Mellitus)

  • 황문숙
    • Journal of Korean Biological Nursing Science
    • /
    • 제22권1호
    • /
    • pp.36-44
    • /
    • 2020
  • Purpose: The purpose of this study was to predict measuring site suited for abdominal skin fold thickness (ASFT) by measuring the distribution of abdominal subcutaneous fat thickness (AScFT) and ascertain the correlations among obesity indicators. Methods: The size of analysis materials was 124 secondary data measured by ultrasonic device, bioelectrical impedance analyzer and caliper. Data were analyzed using t-test, and Pearson's correlation. Results: The average of AScFT was 10.63± 6.79mm with its range 1.39-36.16 mm, and AScFT of female and of central parts were thicker than those of male and outer parts in the abdomen. The average of ASFT was 29.26±12.59 mm. Site 5 on Figure 1 was most similar to the average of AScFT in both sexes. Body mass index (BMI) and waist hip ratio (WHR) were 23.65±3.98 and 0.88±0.05 respectively. The body weight, BMI, WHR, visceral fat, ASFT vs AScFT revealed in significant correlation (r= .29, r= .55, r= .39, r= .33. r= .29). Conclusion: BMI and WHR seem more useful than other obesity indicators, when obesity control is necessary for Type 2 diabetes patients. Site 5 on Figure 1 is most suitable site to measure ASFT.

농산물 수송 트레일러의 현가장치 진동 분석 (Analysis of Vibration Suspension Device for Trailer in Agricultural Products)

  • 홍종호;이성범;박원엽;김성엽;오영근
    • 생물환경조절학회지
    • /
    • 제21권4호
    • /
    • pp.437-444
    • /
    • 2012
  • 본 연구에서는 현제 농가에서 사용하고 있는 진동흡수장치가 전혀 없는 트레일러(E)와 트레일러의 적재규격에 적합하게 평판스프링과 쇽업쇼바를 동시에 설계 제작한 트레일러(I)를 사용하였다. 트레일러에 360kg의 배를 4층으로 적재한 상태로 아스팔트 도로 위를 2m/s로 정속 주행하면서 발생된 평균 진동 주파수의 크기를 상호 비교하여 개발된 트레일러의 진동흡수 효과를 비교 분석하였다. 개발한 현가장치를 장착한 개량된 트레일러는 60Hz 이하와 80Hz 이하의 주파수에서 기존 트레일러에 비해 진동 가속도의 감소 효과가 매우 크게 나타났다. 기존 트레일러에 비하여 개량된 트레일러에서 평균 진동가속도의 크기는 주파수 영역에 따라서 다르긴 하지만 3분의 1까지 대폭 감소시킬 수 있었다. 후방의 상층에 적재된 농산물일수록 진동가속도의 크기가 높아 부패가 빨리 진행 된다고 보고된 논문과 일치하지 않는 이유는 전 연구자는 적재함의 길이가 14,000mm이었고 본 시험에서 사용한 적재함은 1,820mm로 비교적 짧은 것에서 얻어진 결과로 일정한 경향을 찾기가 어려웠던 것으로 판단된다. 모든 주파수의 영역에서 개량된 트레일러가 기존의 트레일러에 비하여는 진동가속도의 크기가 현저히 낮게 나타났다. 특히 40Hz에서 80Hz까지의 주파수대에서 3분의 1로 진동가속도의 크기를 줄일 수 있어서 농산물의 수송 손실을 대폭 감소시킬 수 있을 것으로 판단된다.

공유메모리 프로토콜을 이용한 VXIbus 시스템 구현에 관한 연구 (A Study on Implementation of a VXIbus System Using Shared Memory Protocol)

  • 노승환;강민호;김덕진
    • 한국통신학회논문지
    • /
    • 제18권9호
    • /
    • pp.1332-1347
    • /
    • 1993
  • 기존의 계측기기는 기능에 따라 독립적으로 이루어져 사용자는 사용목적에 따라 각각의 계측기를 이용하여 원하는 계측 시스템을 구성하였다. 그러나 1980년대 후반 VXIbus는 다양한 계측장비를 각각 한장의 카드로 만들어 선택적으로 계측시스템을 구성하는것을 가능하게 하였다. VXIbus의 기본전인 통신 프로토콜에는 word serial 프로토콜이 있다 . 그러나 측정된 데이타의 양이 증가하게 되면 word serial 프로토콜로 인한 전체 시스템의 성능 저하를 가져오게 된다. 본 논문에서는 이러한 성능제한요소를 해결하기 위하여 공유(shared) 메모리 프로토콜을 제안하고, 기존의 word serial 프로토콜과 공유메모리 프로토콜을 GSPN(Generalized Stochastic Petri Net)를 이용하여 분석하였다. 분석한 결과 공유메모리 프로토콜이 word serial 프로토콜보다 성능이 우수함을 알 수 있었다. 또한 제안된 공유 메모리 구조를 갖는 VXIbus 시스템을 구현하였으며 사용된 계측기기로는 VXIbus인터페이스 모듈과 VMEbus 전용 신호처리모듈로 구성 된 FFT 분석 디바이스 그리고 신호발생 디바이스가 이용되었다. FFT 분석실험 결과 최대 80 KHz 입력신호에 대하여 정확하게 분석되었으며 이 결과는 기존의 FFT분석기의 결과와 잘 일치하였고, 신호발생 실험에서는 200 KHz에서 1.1GHz까지의 정현파 신호가 발생되었다.

  • PDF

체간 안정화 운동이 요통환자의 요부안정성과 족저압에 미치는 영향 (Influence of Trunk Stabilization Exercise upon the Lumbar Stabilization and Foot Pressure in Patients with Back Pain)

  • 이우진;박설;박지원
    • The Journal of Korean Physical Therapy
    • /
    • 제26권1호
    • /
    • pp.21-26
    • /
    • 2014
  • Purpose: This study examined the effect of trunk stabilization exercise upon the lumbar stabilization and foot pressure on an unstable surface with back pain. Methods: The subjects of the study were 10 patients who showed the symptom of back pain with excessive lumbar curve. This study was 4 weeks, 30 minutes per session, three times a week for a total of 12 times as a result of exercise radiation imaging device and foot pressure analyzer. Results: The sacrohorizontal angle was statistically significant(p<0.05). Comparison of the difference between static right and left foot pressure ratio analysis was statistically significant(p<0.05). Dynamic right and left foot pressure comparisons for the difference was statistically significant in the analysis (p<0.05). Conclusion: Trunk stabilization exercise and the reduction of the excessive sacrohorizontal angle, and static and dynamic foot pressure imbalance reduced left and right.

Extinguishment of Liquid Fuel Fire by Water Mist Containing Additives

  • Park, Jae-Man;Won, Jung-Il;Shin, Chang-Sub
    • International Journal of Safety
    • /
    • 제4권2호
    • /
    • pp.24-29
    • /
    • 2005
  • An experimental study was presented for extinguishing characteristics of liquid fuel fire by water mist($Dv_{0.99}{\leq}200{\mu}m$) containing potassium acetate and sodium acetate trihydrate. To evaluate the extinguishing performance of water mist containing additives, the evaporation characteristics of a water droplet on a heated surface was examined. The evaporation process was recorded by a charge-coupled-device camera. Also, small-scale extinguishing tests were conducted for n-heptane pool fire in ventilated space. During the experiments, flame temperatures were measured, and concentrations of oxygen and carbon monoxide were analyzed by a combustion gas analyzer. The average evaporation rate of water droplet containing additives was lower than that of pure water at a given surface temperature and decreased with the concentration increase due to the precipitation of salt in the liquid-film and change of surface tension. In case of using additives, the fire extinguishing times was shorter than that of pure water at a given discharge pressure and it was because the momentum of a water droplet containing additives was increased. And also dissociated metal atoms, potassium or sodium, were reacted as a scavenger of the major radical species OH, H which were generated for combustion process. Moreover, at a high pressure of 4 MPa, the fire was extinguished through blowing effect as well as primary extinguishing mechanisms.