Abstract
A low pressure impactor is an impaction device to separate airborne particles into aerodynamic size classes at low pressure condition. We designed a two-stage low-pressure impactor to classify submicron sized environmental aerosols. Performance evaluation was carried out for stages 1 and 2 by using an electrical method. Monodisperse liquid dioctyl sebacate (DOS) particles were generated using evaporation-condensation process followed by electrostatic classification using a DMA (differential mobility analyzer). The test particles were in the range of 0.08∼0.8$\mu\textrm{m}$. For the evaluation of the impactor we used two electrometers; one was connected to the impaction plate of the impactor and the other was to the Faraday cage used as a backup filter. The effect of polydispersity of test aerosols on the performance was investigated. The results showed that the experimental 50-% cutoff diameters at each impactor's operation pressure were 0.53 and 0.187$\mu\textrm{m}$ for stages 1 and stage 2, respectively. The effects of operation pressure on the cutoff diameter and the steepness of collection efficiency curves were also investigated.
Keywords
Low Pressure Impactor; Submicron Particle; Cascade Impactor; Cutoff Diameter;
Citations & Related Records
Times Cited By KSCI : 7  (Citation Analysis)
연도 인용수 순위
1 Ji, J. H., Bae, G. N., and Hwang, J., 2003, 'Nano Particle Charging Characteristics of Aerosol Charge Neutralizers,' KSME Journal B, Vol. 27, pp. 1489-1497   과학기술학회마을   DOI
2 Lodge, Jr., J.P. and Chan, T.L., 1986, Cascade Impactor: Sampling & Data Analysis, American Industrial Hygiene Association
3 Keskinen, J., Pietarinen, K., and Lehtimaeki, M., 1992, 'Electrical Low Pressure Impactor,' J. Aerosol Sci., Vol. 23, pp. 353-360   DOI   ScienceOn
4 Maricq, M. M., Podsiadlik, D. H., and Chase, R. E., 2000, 'Size Distribution of Motor Vehicle Exhaust PM: A Comparison Between ELPI and SMPS Measurement,' Aerosol Sci. Technol., Vol.43, 239-260   DOI   ScienceOn
5 Ahlvik, P., Ntziachristos, L., Keskinen, J., and Virtanen, A., 1998, 'Real Time Measurements of Diesel Particle Size Distribution with an Electrical Low Pressure Impactor,' SAE Technical Paper 980410
6 van Gulijk, C., Schouten, J. M., Marijnissen, J. C. M., Makkee M., and Moulijn, J. A., 2001, 'Restriction for the ELPI in Diesel Particulate Measurements,' J. Aerosol Sci., Vol. 32, pp. 1117-1130   DOI   ScienceOn
7 Hillamo, R. E. and Kauppinen, E. I., 1991, 'On the Performance of the Berner Low Pressure Impactor,' Aerosol Sci. Technol. Vol. 14, pp. 33-47   DOI   ScienceOn
8 Keskinen, J., Marjamaeki, M., Virtanen, A., Maekelae, T., and Hillamo, R., 1999, 'Electrical Calibration Method for Cascade Impactors,' J. Aerosol Sci., Vol. 30, pp. 111-116   DOI   ScienceOn
9 Bae, G. N., Ji, J. H., and Moon, K. C., 1999, 'Collection Characteristics of a MOUDI Cascade Impactor for Coarse Particles,' J. Korea Air Pollution Research Association, Vol. 15, No. 6, pp. 799-804   과학기술학회마을
10 Rader, D. J. and Marple, V. A., 1985, 'Effect of Ultra-Stokesian Drag and Particle Interception on Impaction Characteristics,' Aerosol Sci. Technol., Vol. 4, pp. 141-156   DOI   ScienceOn
11 Ji, J. H., 2003, Change of Particle Size Distribution Using Corona Discharge and Classifying Characteristics of Charged Particles, Ph.D. Thesis, Yonsei University
12 TSI Coporation, 1999, Model 3936 SMPS(Scannin Mobility Particle Sizer) Instruction Manual
13 Marjamaeki, M., Keskinen, J., Chen, D. R., and Pui, D. Y. H., 2000, 'Performance Evaluation of the Electrical Low-Pressure Impactor (ELPI),' J. Aerosol Sci., Vol. 31, No. 2, pp. 249-261   DOI   ScienceOn
14 Ji, J. H., Bae, G. N., and Hwang, J., 2001, 'Design and Performance Evaluation of a Three Stage Impactor,' Korea Society for Atmospheric Environment, Vol. 17, No. 6, pp. 441-450   과학기술학회마을
15 Ji, J. H., Bae, G. N., and Hwang, J., 2003, 'Effect of Particle Clogging in Orifices on the Particle Collection Efficiency of a Micro-Orifice Impactor,' KSME Journal B, Vol. 27, No. 2, pp. 197-205   과학기술학회마을   DOI
16 Flagan, R. C., 1982, 'Compressible Flow Inertial Impactors,' J. Coll. Interface Sci., Vol. 87, pp. 291-299   DOI   ScienceOn
17 Biswas, P. and Flagan, R. C., 1984, 'High Velocity Inertial Impactors,' Envir. Sci. Technol., Vol. 18, pp. 611-616   DOI   ScienceOn
18 Hering, S. V., Flagan, R. C. and Friedlander, S. K., 1978, 'Design and Evaluation of New Low Pressure Impactor. 1.,' Envir. Sci. Technol., Vol. 12, pp. 667-673   DOI   ScienceOn
19 Ji, J. H., Bae, G. N., and Hwang, J., 2003, 'Effect of Performance of Aerosol Charge Neutralizers on the Measurement of Highly Charged Particles Using a SMPS,' KSME Journal B, Vol. 27, pp. 1498-1507   과학기술학회마을   DOI