• 제목/요약/키워드: On-Line Test

검색결과 3,405건 처리시간 0.032초

뜸줄 길이가 패류껍질어구의 유실에 미치는 영향 (Effect of length of buoy line on loss of webfoot octopus pot)

  • 이건호;조삼광;차봉진;정성재
    • 수산해양기술연구
    • /
    • 제52권4호
    • /
    • pp.299-307
    • /
    • 2016
  • This study aims to investigate effects of the length of the buoy and sand bag line on the loss of webfoot octopus pot. A numerical modeling and simulation was carried out to analyze the process that the pot gear affected by wave using the mass spring model. Through the simulation, tensions of sand bag line under various condition were investigated by length of buoy and sand bag line. The drag force and coefficient k of an artificial shell used in the webfoot octopus pot was obtained from an experiment in a circular water channel, and the coefficient k was applied to the simulation. To verify the accuracy of the simulation model, a simple test was conducted into measuring a rope tension of a hanging shell under flow. Then, the test result was compared with the simulation. The lengths of the buoy line in the simulation were 1.12, 1.41, 1.80, 2.23, 2.69, and 3.17 times of water depth. The lengths of sand bag line were 10, 20, 30, and 40 meters, and conditions of water depth were 8, 15, 22 meters. 4 meter height and 8 second period of wave were applied to all simulations. As a results, the tension of the sand bag line was decreased as the buoy and sand bag line were increased. The minimum tension of the sand bag line was appeared in conditions that the length of the buoy line is twice of water depth and the sand bag line length is over 40 meters (except in case of depth 8 meters.).

In Line Orifice Mixer에서의 응집제 확산분포 특성 (Characteristics of coagulants dispersion within In-Line Orifice Mixer)

  • 임경호;박영오;박대진;박노석;고태곤
    • 상하수도학회지
    • /
    • 제22권6호
    • /
    • pp.689-696
    • /
    • 2008
  • In a water treatment process a complete and homogeneous dispersion of the coagulants in the raw water could be most important factor. This research was performed to evaluate coagulation performance of the in-line-orifice mixer which was recently introduced as a rapid mixing device. The test was to determine the actual coagulant dispersion distribution on the overall cross-section at a distance of 1.6~3D from the chemical injection point by measuring zeta potential. From the results of zeta potential test, it was shown that the coagulant dispersion within the in-line orifice mixer was occurred very unevenly. The results have confirmed that it is necessary to increase the velocity of coagulants injection or pressurized water rates, in order to reduce nonuniform distribution of chemicals.

22.9kV 배전선로 절연전선의 부식 검출 시스템 개발에 대한 연구 (A Study on the Development of Corrosion Detecting System for 22.9 kV Distribution Power Line Insulation Cable)

  • 김용준;오용철;이건영
    • 전기학회논문지
    • /
    • 제60권7호
    • /
    • pp.1410-1416
    • /
    • 2011
  • A corrosion detecting system for 22.9 kV distribution power line insulation cable, which can travel autonomously along the live line, is proposed. Eddy current test method is employed to detect the corrosion, and the system developed here is capable of detecting internal corrosion of a ACSR-OC. Somewhat details of the electrical and mechanical mechanism of the system and traveling algorithm are introduced. Experimental results applied to the sample cables having artificial corrosion and the operating distribution lines are provided. From the result, we confirmed that the system is useful for detecting internal corrosion of a ACSR, and is expected to be a new non-destructive testing equipment in the area of diagnosis for the distribution power line.

개폐서지 및 뇌충격 섬락시험에 따른 송전 피뢰기의 직렬공극 특성 (Series-Gap Characteristics of Transmission Line Arrester with Switching and Lightning Impulse Flashover Test)

  • 조한구;유대훈
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.484-485
    • /
    • 2007
  • This paper describes the series-gap characteristics of transmission line arrester with switching and lightning impulse flashover test. The transmission line arrester exhibited external gap because it is must not flashover with switching impulse on the other hand it is must flashover with lightning impulse. In accordance, minimum and maximum length of series-gap was determinated with these tests. As gap length is increased flashover voltage was increased in the range of 315.4 kV~496.3 kV and negative polarity exhibited a high voltage. As a result, It was thought tat the series-gap length of transmission line arrester exhibited in the range of 580 mm~1100 mm.

  • PDF

선로절환에 의한 과부화 해소 앨고리즘 (An Overload Alleviation Algorithm by Line Switching)

  • 박규홍;정재길
    • 대한전기학회논문지
    • /
    • 제41권5호
    • /
    • pp.459-467
    • /
    • 1992
  • This paper presents a new algorithm for the countermeasure to alleviate the line overloads due to contingency without shedding loads in a power system. This method for relieving the line overloads by line switching is based on obtaining the kine outage distribution factors-the linear sensitivity factors, which give the amount of change in the power flow of each line due to the removal of a line in a power system. There factors are made up of the elements of sparse bus reactance matrix and brach reactances. In this paper a fast algorithm and program is presented for obtaining only the required bus reactance elements which corresponds to a non-zero elements of bus admittance matrix, and elements of columns which correspond to two terminal buses of the overloaded(monitored) line. The proposed algorithm has been validated in tests on a 6-bus and the 30-bus test system.

  • PDF

경산시험선 CBTC 시스템용 무선통신시스템 시험(1) (Analysis and Test of CBTC Wireless Communication System in KyungSan test Line (I))

  • 조봉관;류상환;이안호;황현철;박기수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.2731-2734
    • /
    • 2011
  • Korean-Automated Guideway Transit (K-AGT) was successfully developed through Light Rail System Development Project. Since then, the domestic development rate of on-board signalling system of light rail has been improved up to 90% by Practical Utilization Project of Light Rail. After utilization project, furthermore, POSCO ICT has developed the wayside signalling system of CBTC, including wireless communication equipment. KRRI carried out the performance test of the wireless communication, interfacing and using the other CBTC equipments of KyungSan Test Line so as to see whether it conforms IEEE 802.11x, international communication standard in view of operational concept of CBTC. In this paper, we presents the test plan, test items, and the analysis results of maximum communication distance tests between on-board and wayside radio sets.

  • PDF

구성가능한 소프트웨어 제품라인 시험에서 코드 커버리지 측정 (Code Coverage Measurement in Configurable Software Product Line Testing)

  • 한수빈;이지현;고서연
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제11권7호
    • /
    • pp.273-282
    • /
    • 2022
  • 구성가능한 소프트웨어 제품라인 시험은 모든 멤버제품들에 포함되는 공통 부분과 일부 또는 단일 제품에 포함되는 가변 부분을 고려해야 하기 때문에 단일 제품 시험 방법들을 그대로 적용하기 어렵다. 소프트웨어 시스템 시험에서 시험 커버리지는 수행된 시험의 적절성을 측정하는 척도이다. 구성가능한 소프트웨어 제품라인으로부터 생성될 수 있는 멤버제품들은 수백 개에 이를 수 있기 때문에 시험 커버리지 측정은 소프트웨어 제품라인 수준에서 시험의 적절성을 평가하기 위해 중요하다. 이 논문은 구성가능한 소프트웨어 제품라인 시험에서 제품라인 수준의 코드 커버리지 측정 방법을 제안한다. 제안한 방법은 피처 집합의 포함 관계를 기준으로 제품들을 계층화한 후 제품라인의 멤버제품들을 시험하고, 시험으로부터 얻어진 각 제품의 시험 커버리지들을 종합하여 SPL 시험 커버리지를 정량화한다. 제안한 방법을 11개의 구성가능한 소프트웨어 제품라인 사례에 적용하여 검증한 결과, 제안한 방법은 SPL 시험이 얼마나 철저하게 수행되었는지를 정량적으로 기술하여 SPL 시험의 적정성을 확인할 수 있도록 도왔다. 또한, 새로 추가된 SPL 멤버제품의 시험이 이전 멤버제품 시험 대비 커버리지를 증가시키는 방향인지 확인할 수 있어 새로운 시험케이스들이 멤버제품들 간의 차이를 커버하는 방향으로 시험이 이루어지고 있는지 확인할 수 있었다.

765kV 교류 송전선로의 가청소음계산 예측식개발(I) (Predicting formula development of audible noise on a 765kV AC transmission line(I))

  • 이동일;구자윤
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.612-615
    • /
    • 1996
  • Audible noise from corona discharge had been identified as one of the most important factors in the design of conductor configurations for high-voltage transmission lines. 500kV and above. Therefore this paper describes audible noise characteristics of 6 X 480mm conductor bundle in KEPRI 765kV Test Line and Corona Cage. Prediction formula for audible(corona) noise on a 765kV transmission Line was developed using this results.

  • PDF

3D Line Segment Extraction Based on Line Fitting of Elevation Data

  • Woo, Dong-Min
    • 전기전자학회논문지
    • /
    • 제13권2호
    • /
    • pp.181-185
    • /
    • 2009
  • In this paper, we are concerned with a 3D line segment extraction method by area-based stereo matching technique. The main idea is based on line fitting of elevation data on 2D line coordinates of ortho-image. Elevation data and ortho-image can be obtained by well-known area-based stereo matching technique. In order to use elevation in line fitting, the elevation itself should be reliable. To measure the reliability of elevation, in this paper, we employ the concept of self-consistency. We test the effectiveness of the proposed method with a quantitative accuracy analysis using synthetic images generated from Avenches data set of Ascona aerial images. Experimental results indicate that our method generates 3D line segments almost 7.5 times more accurate than raw elevations obtained by area-based method.

  • PDF

단자속양자 회로 측정프로브의 특성 분석을 위한 시뮬레이션 (Simulation for characterization of high speed probe for measurement of single flux quantum circuits)

  • 김상문;김영환;최종현;조운조;윤기현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권2호
    • /
    • pp.11-15
    • /
    • 2002
  • High speed probe for measurement of sin91e flux quantum circuits is comprised of coaxial cables and microstrip lines in order to carry high speed signals without loss. For the impedance matching between coaxial cable and microstrip line, we have determined the dimension of the microstrip line with 50${\Omega}$ impedance by simulation and then have investigated the effect of line width and cross-sectional shape of signal line, dielectric material, thickness of soldering lead at the coaxial-to-microstrip transition Point, and the an91c between dielectric material and end part of the signal line on the characteristics of signal transmission of the microstrip line. From the simulation, we have found that these all parameter's had influenced on the characteristic of signal transmission on the microstrip line and should be reflected in fabricating high speed probe, We have also determined the dimension of coplanar waveguide to fabricate testing sample for performance test of high speed probe.