• 제목/요약/키워드: Oil quality 2-S

검색결과 202건 처리시간 0.026초

The Effect of Feeding Different Levels of Sardine Fish Silage on Broiler Performance, Meat Quality and Sensory Characteristics under Closed and Open-sided Housing Systems

  • Al-Marzooqi, W.;Al-Farsi, M.A.;Kadim, I.T.;Mahgoub, O.;Goddard, J.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제23권12호
    • /
    • pp.1614-1625
    • /
    • 2010
  • Two experiments were conducted to evaluate the use of fish silage prepared from Indian oil sardines, Sardinella longiceps, as partial replacement of soybean meal as a sole source of protein for growing broiler chickens. The main objective of Experiment 1, an ileal digestibility assay, was to assess the nutritional value of fish silage compared with soybean meal for feeding broiler chickens. The two test ingredients, soybean meal and dried fish silage, were incorporated into semi-synthetic diets, as the only component containing protein. The ileal digestibility coefficients of amino acids of fish silage were considerably higher than those of soybean meal (p<0.001). The lower digestibility of amino acids from soybean meal was related to the presence of anti-nutritional factors such as trypsin inhibitors. Fish silage had higher levels of sulphur-containing amino acids than soybean meal. The objective of Experiment 2, a growth study, was to evaluate the effect of feeding fish silage on performance and meat quality characteristics of broiler chickens raised under closed and open-sided housing systems. Four diets containing various levels of fish silage (0, 10, 20 and 30%) were evaluated. Daily feed intake, body weight gain and feed conversion ratio were measured. At the end of Experiment 2, 96 birds were randomly selected and slaughtered to evaluate meat quality characteristics. Housing type had significant effects on feed intake and body weight gain (p<0.01). Birds in the open-sided house consumed 4.7% less amount of feed and gained 10.6% less than their counterparts in a closed house. Birds in both houses fed diets containing 10 and 20% fish silage gained more than birds fed 30% fish silage. The current study produced evidence that fish silage can replace up to 20% of soybean meal in broiler diets without affecting either growth performance or the sensory quality of broiler meat.

올리브유처리 토마토 분말과 정제 Lycopene이 저장 중 양념육의 물리화학적 및 관능적 특성에 미치는 영향 (Effect of Olive-Oil Prepared Tomato Powder (OPTP) and Refining Lycopene on the Physicochemical and Sensory Characteristics of Seasoned Raw Pork During Storage)

  • 김일석;진상근;강석남;허인철;최승연
    • 한국축산식품학회지
    • /
    • 제29권3호
    • /
    • pp.334-339
    • /
    • 2009
  • 양념육은 돼지고기 등심을 이용하여 올리브유처리 열풍 건조 토마토 분말(OPTP) 1.5%(T1) 및 3.0%(T2) 투입과 정제 lycopene을 0.03%(T3)을 첨가하여 제품을 제조하였으며, 저장 3, 6, 9일차에 이들의 물리화학적, 미생물학적 및 관능적인 특성에 대해 조사하였다. 저장기간 동안 처리구가 대조구보다 낮은 pH값을 나타내었다. 염도는 T3를 제외하고는 저장기간이 경과함에 따라 유의적으로 증가하였다. TBARS는 저장 3일차에 OPTP가 증가할수록 낮은 TBARS값을 나타내었으나 T3는 대조구와 유의적인 차이가 나타나지 않았다. VBN함량은 저장 3일차에 T2가 가장 낮았고, 저장 9일 이후 T1 및 T2가 가장 높게 나타났다. 총균수는 저장 3일차에 T3이 가장 낮게 나타났으나 저장 6 및 9일차에는 유의적인 차이가 없었다. 명도는 저장 3일차에 T2및 T3가 대조구보다 낮게 나타났으며, 저장 기간 동안 적색도, 황색도 및 chroma 값은 처리구가 대조구보다 높은 경향이었다. 관능검사시 육색, 연도, 다즙성 및 전체적인 기호도는 시험구간 유의적인 차이가 나타나지 않았지만 향기의 경우 저장 3 및 6일차에 T2가 다른 시험구보다 유의적으로 높게 나타났다.

인도네시아 열대작물 오일의 Amberlyst-15 촉매 에스테르화 반응 및 바이오디젤 물성 분석 (Esterification of Indonesia Tropical Crop Oil by Amberlyst-15 and Property Analysis of Biodiesel)

  • 이경호;;이준표;이진석;김덕근
    • 한국응용과학기술학회지
    • /
    • 제36권1호
    • /
    • pp.324-332
    • /
    • 2019
  • 한국과 인도네시아를 포함한 대부분의 국가는 온실가스 감축을 위해 바이오디젤 같은 바이오연료 보급에 대한 강력한 정책을 추진하고 있다. 하지만, 바이오디젤 보급 확대를 위해서는 원료 부족 문제를 먼저 해결해야 한다. 본 연구에서는 원료 공급 안정성을 개선하고 바이오디젤 생산 가격을 낮추기 위해 비식용이면서 동시에 단위면적당 생산성이 높은 인도네시아 열대작물(R. Trisperma) 오일의 바이오디젤 생산 가능성을 조사하였다. 수확기간이 다른 두 종류의 오일은 많은 불순물과 높은 유리지방산 함량을 가지고 있어 효율적인 바이오디젤 생산을 위해, 에스테르화 반응과 전이에스테르화 반응을 실시하였다. 오일은 반응을 진행하기 앞서 여과와 수분제거 과정을 통해 반응의 효율을 높이고자 하였다. 에스테르화 반응은 불균질계 산 촉매인 Amberlyst-15를 사용하였으며, 반응 전 오일들의 산가는 각각 41, 17 mg KOH / g이었으나, 에스테르화 반응 후 3.7, 1.8 mg KOH/g으로 약 90% 이상의 전환율을 보이며 유리지방산 함량을 2%이하로 감소시켰다. 이후 전이에스테르화 반응은 KOH를 염기 촉매로 사용하여 바이오디젤 합성 실험을 진행하였다. 생성된 바이오디젤은 약 93%의 FAME 함량을 나타냈으며, 총 글리세롤의 함량은 0.43%으로 제품 규격(FAME 96.5%, 총 글리세롤 0.24%)에는 미달되었다. 이는 지방산 조성 분석 결과 일반적으로 관찰되지 않는 특이 지방산인 ${\alpha}$-Eleostearic acid가 10.7~33.4% 포함되어 나타나는 특성으로 판단되며, 추가 반응 최적화 및 분리정제 연구 진행으로 연료품질 규격 달성이 필요한 것으로 나타났다. 기존에 활용되지 못하던 비식용 원료로부터 바이오디젤 생산 기술을 확보할 경우 바이오디젤 보급 확대를 위한 안정적 원료 공급에 기여할 것으로 판단된다.

유통되고 있는 삶은 고래고기의 안정성 연구 (A Study on Lipids Oxidation Boiled Whale Meat’s in Process of Circulation Market)

  • 최민경;김경옥
    • 한국가정과학회지
    • /
    • 제7권1호
    • /
    • pp.33-41
    • /
    • 2004
  • The purpose of the study was to analyze in process of circulation market boiled whale meat's rancidity. oxidative rancidity is oil or fat food depend on oxygen in air oxidative change in quality. boiled whale meat faty come to oxidative rancidity food stability and hygiene reasons for people health poisonous point out, however it is not indication study of support. Accordingly confirm lead into circulation process boiled whale meat's rancidity examination and microorganism examination boiled whale meat's stability whether or not. The result obtained were summarized as follows: 1. Proximate percentage of boiled whale meat(pectoral, pelvic, fin, flank) of moisture and crude lipid and crude protein from samples shown to be : moisture was pectoral 16.4%, pelvic 36.2%, fin 46.2%, flank 19.2%, crude lipid was pectoral 54.1%, pelvic 42.8%, fin 15.8%, flank 40.6%,crude protein was pectoral 29.4%, pelvic 20.5%, fin 29.5%, flank 28.6%. 2. The fatty acid composition of total lipid were composed of pectoral 27.2%, pelvic 28.9%, fin 33.3%, flank 23.4% of oleic acid and pectoral 12.7%, pelvic 11.1%, fin 11.3%, flank 14.0% of palmitic acid pectoral 10.8%, pelvic 7.9%, fin 7.6%, flank 2.1% of docosahexaenoic acid, pectoral 14.2%, pelvic 7.5%, fin 1.9%, flank 7.2% of eicosenoic acid, pectoral 5.1%, pelvic 5.7%, fin 4.4%, flank 5.7% of myristic acid, 16: 0 11∼14 % of high saturated fatty acid. generally most of 18: 1ω9 of boiled whale meat's each portion, 22:6 7∼12%, 20:5 1∼14% of polyenoic fatty acid. 18:3 showen to be 1% make an expection of pectoral and fin portion the total lipid were most of netural lipid's about 90%, monoenic fatty acid were most of 19∼22% of saturated fatty acid, 77∼80% of monoenic fatty acid level of 47∼56% of 18:1 16:1 was markelly high to those of total lipid. 3. The storage number days variation of oxidation were shown to be by stages process favorably the past days of boiled whale meat's acid value for 5days. pectoral the day 0.1, five days 1.3, pelvic the day 0.1, five days 1.6, fin the day 0.3, five days 0.7, flank the day 0.2, five days 0.4. 4. The sealer and wrapper the storage number days variation of boiled whale meat oxidation for 7days were shown to be a stage of sealing, the temperature of a room, pectoral the day 0.1 seven days 0.6, pelvic the day 0.1, seven days 1.3, fin.

  • PDF

Evaporation Heat Transfer Characteristics of $CO_2$ in a Horizontal Tube

  • Lee Dong-Geon;Son Chang-Hyo;Oh Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권3호
    • /
    • pp.297-305
    • /
    • 2005
  • The evaporation heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver. a variable-speed pump. a mass flow meter. a pre-heater and evaporator (test section). The test section consists of a smooth. horizontal stainless steel tube of 7.75 mm inner diameter. The experiments were conducted at mass flux of 200 to $500\;kg/m^{2}s$. saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$. and heat flux of 10 to $40\;kW/m^2$. The test results showed the evaporation heat transfer of $CO_2$ has greatly effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality. heat flux and saturation temperature. The evaporation heat transfer coefficient of $CO_2$ is very larger than that of R-22 and R-134a. In making a comparison between test results and existing correlations. the present experimental data are the best fit for the correlation of Jung et al. But it was failed to predict the evaporation heat transfer coefficient of $CO_2$ using by the existing correlation. Therefore. it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

Evaporation Heat Transfer Characteristics of $CO_2$ in a Horizontal Tube

  • Son Chang-Hyo;Kim Dae-Hui;Choi Sun-Muk;Kim Young-Ryul;Oh Hoo-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권4호
    • /
    • pp.167-174
    • /
    • 2005
  • The evaporation heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth horizontal stainless steel tube of 7.75 mm inner diameter. The experiments were conducted at mass flux of 200 to $500kg/m^2s$, saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed the evaporation heat transfer of $CO_2$ has greater effect on nucleate boiling than convective boiling. The evaporation heat transfer coefficient of $CO_2$ is highly dependent on the vapor quality, heat flux and saturation temperature. The evaporation heat transfer coefficient of $CO_2$ is very larger than that of R-22 and R-134a. In comparison with test results and existing correlations, the best fit of the present experimental data is obtained with the correlation of Jung et al. But the existing correlations failed to predict the evaporation heat transfer coefficient of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

동해 울릉분지 CO2 저장소 특성 분석을 위한 탄성파 자료처리 및 역산 (Seismic Data Processing and Inversion for Characterization of CO2 Storage Prospect in Ulleung Basin, East Sea)

  • 이호용;김민준;박명호
    • 자원환경지질
    • /
    • 제48권1호
    • /
    • pp.25-39
    • /
    • 2015
  • $CO_2$ 지중저장은 국가 온실가스 감축 목표 달성에 가장 큰 역할을 담당할 것으로 평가되고 있으나, 포집분야 일부 기술을 제외하고 저장 및 실증에 대한 국내 연구는 여전히 부족한 실정이다. CCS(Carbon Capture and Storage)의 가장 큰 목표는 지하 퇴적 암반층에 $CO_2$를 안전하게 저장하는 것이며, 이를 위해서는 저장소의 저장용량 및 안정성등과 같은 지중저장 대상지층의 특성을 정확하게 파악하고 그에 맞는 주입 전략을 수립하여야 한다. 이번 연구에서는 한국석유공사가 2012년에 울릉분지에서 취득한 탄성파 탐사자료를 활용하여 $CO_2$ 저장 후보 지층에 대한 탄성파 임피던스 역산을 수행하고, 공극률의 분포와 지층의 속성을 도출하여 $CO_2$ 지중저장 가능성을 검토하였다. 우선, 탄성파 자료 역산의 신뢰도를 높이기 위해 다양한 방법의 잡음제거 기법을 적용하였고, 특히 본 자료의 주파수 및 위상 특성을 그대로 유지한 채 다중반사파를 제거할 수 있는 SWD(Shallow Water Demultiple), SRME(Surface Related Multiple Elimination), Radon Demultiple 기술을 활용하였다. 자료 역산을 위해 3개의 시추공에 대한 물리검층 자료를 분석하였는데, 탄성파 자료와의 상관도가 각각 0.648, 0.574, 0.342로 나타났으며 이는 초기 역산 모델 설정을 위한 저주파수 모델 생성에 활용하였다. 중합 전 역산을 통해 P-임피던스, S-임피던스 및 Vp/Vs 비 값을 도출하였으며, 이와 물리검층 결과의 비교, 분석을 통해 공극률 분포 양상을 확인함으로써 지중저장에 적합한 지층을 파악할 수 있었다. 향후 $CO_2$ 주입 실증을 위해서는 지층에 대한 보다 세밀한 특성 분석과 모사를 통한 주입 이후 $CO_2$ 거동예측이 필요할 것이다.

세관내 이산화탄소의 증발 열전달 및 압력강화 (Evaporation Heat Transfer and Pressure Drop of $CO_2$ in a Small diameter Tube)

  • 장승일;최선묵;김대희;박기원;오후규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.189-194
    • /
    • 2005
  • The evaporation heat transfer and pressure drop of $CO_2$ in a small diameter tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator(test section). The test section was made of a horizontal stainless steel tube with the inner diameter of 4.57 mm, and length of 4 m. The experiments were conducted at mass flux of 200 to 700 $kg/m^2s$, saturation temperature of $0^{\circ}C$ to $20^{\circ}C$, and heat flux of 10 to 20 $kW/m^2$ . The test results showed the evaporation heat transfer of $CO_2$ has great effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. The evaporation pressure drop of C02 are highly dependent on the mass flux. In comparison with test results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient and pressure drop of $CO_2$, therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient and friction pressure drop of $CO_2$ in a horizontal tube.

  • PDF

수평원관내 $CO_2$의 증발열전달 (Evaporation Heat Transfer of Carbon Dioxide in a horizontal Round Tube)

  • 경남수;장승일;최선묵;손창효;오후규
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.262-267
    • /
    • 2005
  • The evaporation heat transfer coefficient of $CO_2$ in a horizontal round tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator(test section). The test section was made of a horizontal stainless steel tube with the inner diameter of 7.75 mm, and length of 5 m. The experiments were conducted at mass flux of 200 to 500 $kg/m^2s$, saturation temperature of $-5^{\circ}C$ to $5^{\circ}C$, and heat flux of 10 to 40 $kW/m^2$. The test results showed the evaporation heat transfer of $CO_2$ has great effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. In comparison with teat results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient of $CO_2$, therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

  • PDF

자원의 저주에 대한 비판적 고찰 (The Doubtful Existence of Resource Curse)

  • 김동구
    • 자원ㆍ환경경제연구
    • /
    • 제22권2호
    • /
    • pp.215-250
    • /
    • 2013
  • "자원의 저주"란 천연자원이 풍부한 국가들이 오히려 경제적으로 낙후되어 있다는 학설이다. 본 논문에서는 기존 연구들과 달리 천연자원 보유 및 생산량이 경제수준과 강한 양(+)의 회귀계수를 보이는 것으로 분석하고 있다. 이러한 결과는 1인당 자본스톡 등 경제성장과 연관된 다양한 설명변수들을 포함시켰을 때에도 유지되고 있다. 이러한 점에서 자원의 저주가 실제로 존재하는 지는 의문이다. 다음으로 천연자원이 경제에 미치는 긍정적인 영향을 통제하고 나서 천연자원 보유 및 생산량에 따른 한 나라의 제도발전 정도를 회귀분석한 결과, 구소련지역 국가들을 포함시키게 되면 선행연구인 Alexeev and Conrad(2009)와는 달리 천연자원 보유량이 제도발전 정도와 음(-)의 회귀계수를 가질 수도 있는 것으로 나타났다. 그러나 이러한 음(-)의 회귀계수는 구소련지역 국가들을 분석대상에서 제외하면 모두 통계적 유의성을 상실하였으며, 통계적으로 유의하지는 않지만 상당수 분석결과에서는 양(+)의 회귀계수도 도출되었다. 즉, 음의 회귀계수는 구소련지역 국가들에 의해 도출된 것이라고 할 수 있다. 이러한 결과는 구소련 지역 국가들의 체제이행기 서방자본의 유입으로 인한 천연자원 보유 및 생산량의 급증과 체제변환에 따른 정치경제적 불안정이 동시에 발생한 때문이며, 일시적이고 다분히 우연에 의한 결과로 추정된다. 따라서 천연자원 보유량이 제도 발전 정도에 부정적인 영향을 미친다는 주장도 그 근거가 다소 희박하다고 하겠다.