• 제목/요약/키워드: Oil flow

검색결과 1,068건 처리시간 0.027초

Development of a 300 HP Class Turbo Blower with Air Foil Bearings (공기 포일 베어링을 사용하는 300마력급 터보송풍기 개발)

  • Kim, Kyeong-Su;Lee, Ki-Ho;Park, Ki-Cheol;Lee, Si-Woo;Kim, Seung-Woo
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.331-334
    • /
    • 2006
  • Air foil bearings have been attempted for application to industrial turbo machines, since they have several advantages over oil bearings in terms of endurance, simplicity, environment-friendliness, efficiency, sound and vibration, and small turbo machines with air foil bearings are in the market as the result. Recently, researches on widening the application spectrum of air foil bearings are in progress worldwide. In this paper, a 300 HP class turbo blower using air foil bearings is introduced. The turbo blower has a high speed PMSM(Permanent Magnet Synchronous Motor) driving a compressor, and air flow rate is designed to be $180\;m^3/min$ at pressure ratio of 1.6. The maximum rotational speed is set to 17,000 RPM to maximize the total efficiency with the result that the weight of rotor assembly is 26kg, which is expected to be the largest turbo machine with air foil bearings ever developed in the world.

  • PDF

NUMERICAL METHODS FOR OPEN WATER PERFORMANCE PREDICTION OF HORIZONTAL AXIS TIDAL STREAM ENERGY CONVERSION TURBINE (조류발전용 수평축터빈의 단독성능 평가를 위한 수치 해석법)

  • Lee, J.H.;Kim, D.J.;Rhee, S.H.;Kim, M.C.;Hyun, B.S.;Nam, J.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.155-162
    • /
    • 2010
  • Recently, due to high oil prices and environmental pollution issues, interest of alternative energy development increases and the related research is widely conducted. Among those research activities the tidal stream power generation utilizes the tidal flow as its mechanical power resource and less depends on the environmental condition for installation and operation than other renewable energy resources. Therefore the amount of power generated is quite consistent and straightforward to predict. However, research on the tidal stream energy conversion turbine is rarely found. In the present study, two numerical methods were developed and compared for the open water Momentum Theory, which is widely used for wind turbines, was adopted. The moving reference frame method for Computational Fluid Dynamis solver were also used. Hybrid meshing was used for the complex geometry of turbines. The analysis results using each method were compared to figure out a better method for the performance prediction.

  • PDF

Study on the Evaporation Heat transfer of $CO_2$ in a Horizontal tube (수평관내의 $CO_2$의 증발 열전달에 관한 연구)

  • Jang, Seong-Il;Choi, Sun-Muk;Kim, Dae-Hui;Oh, Hoo-kyu
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.240-241
    • /
    • 2005
  • The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator(test section). The test section was made of a horizontal stainless steel tube with the inner diameter of 4.57 mm, and length of 4 m. The experiments were conducted at mass flux of 200 to 700 kg/$m^2s$, saturation temperature of 0$^{circ}C$ to 20$^{circ}C$, and heat flux of 10 to 30 kW/$m^2$. The test results showed the evaporation heat transfer of $CO_2$ has great effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. In comparison with test results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient of $CO_2$, therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

  • PDF

Infinitesimal Fluid Injection Control System by using an Orifice and a Directional Control Valve (오리피스와 방향제어밸브를 이용한 미세유량 분사제어시스템)

  • Jeong, Eun-Seok;Oh, In-Ho;Lee, Ill-Yeong
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.67-68
    • /
    • 2006
  • This study suggests a precision flow control system that enables fluid injection of a few grams at a time in a few ms time duration. The fluid injection system suggested here consists of a high pressure fluid pump, a 3 way 3 position directional control valve, an injector and an orifice. The orifice is located between the directional control valve and the injector. By supplying current signal to the directional control valve, the prescribed small amount of fluid can be supplied to a plant through the injector. The control robustness of the suggested system against the disturbances like the pressure change in a plant and the viscosity variation of the injected fluid is secured easily by using an orifice with very small inside diameter and setting the supply pressure with comparatively high value. The control performances of the suggested system are verified by numerical simulations and experiments. The outcomes of this research could be applied to the common rail injection control of lubrication oil for large size marine diesel engines, and other industrial plants.

  • PDF

A Study on Proposal of the Ship's Routing on Gwangyang Harbor (광양항의 항로설정에 관한 연구)

  • Jeong Jung-Shic;Jong Jae-Yong;Kim Chol-Seong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • 제11권2호
    • /
    • pp.9-17
    • /
    • 2005
  • In the present maritime traffic conditions of Gwangyang harbor, there exists many hazardous factors which may lead to huge accidents including marine oil pollution. To mitigate the danger to vessels in Gwangyang harbor and to secure the safety of maritime environment, we established one way traffic between No.3 Route and No.4 Route, Designed of deep water line on No.3 route, Extended one-way route for Myo-Do Passage etc.

  • PDF

Habitat Segregation between NE and NS Type of Zacco korean us (Cyprinidae) (참갈겨니, Zacco koreanus(잉어과)의 NE형과 NS형의 서식처 분리)

  • Chae, Byung-Soo;Yoon, Hee-Nam
    • Korean Journal of Ichthyology
    • /
    • 제22권1호
    • /
    • pp.49-55
    • /
    • 2010
  • Sympatric sites of type NE and NS of Zacco korean us were found in the upper reaches of many tributaries of the Nakdong and Seomjin rivers, as well as in some streams draining into the South Sea, Korea. In streams where the two types exist together, there was a tendency for individuals of NE to densely populate the upper reaches and those of NS to populate the middle reaches. A habitat-segregation phenomenon was observed in the cohabiting sites. Fishes of NE preferred rapids, whereas fishes of NS preferred slowly flowing or lentic regions. It seemed that the number of NE was proportional to the flow velocity, but NS showed an opposite trend in the cohabiting sites. On the other hand, such tendency was not found in regions where NE and NS exist separately.

False Alarm Filtering Algorithm Development of Pipeline Leak Detection System using Flow Volume Balance (유량 밸런스 특성을 활용한 송유관 누유 감지 시스템의 오알람 필터링 알고리즘 개발)

  • Kim, Min-Sung;Kim, Hie-Sik;Jung, Hae-Kyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • 제53권10호
    • /
    • pp.95-102
    • /
    • 2016
  • Pipeline is making the most use of transportation of petroleum products on the land. But due to tremendous accident or environmental disaster by oil pipeline leak or pipeline stolen, leak detection systems have been used for preventing it. Leak detection method based on negative pressure wave has been used at the long distance pipeline. But even if it has showed good leak detection quality, due to making a lot of false alarm, it has weak point that disturbs concentration to system. This study suggests algorithm and method of using volume balance to decrease false-alarm of pipeline leak detection system based on negative pressure wave.

Design and Dynamic Behavior Prediction of a 4-DOF Piping Joint (4-자유도 배관 관절의 설계 및 동적 거동 예측)

  • Lee, Yunyong;Kang, Hwankook;Lee, Jong Rim;Lim, Seungchul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • 제26권3호
    • /
    • pp.298-307
    • /
    • 2016
  • In the building process of FPSOs(floating production, storage and offloading units) is the increasing demand of high performance piping joints that can be installed on its turret system and maintain smooth and long-term flow of ultra-high pressure crude oil, being subjected to external excitations such as wind and wave on the sea. Following such a trend, in this paper, a new-type piping joint of four effective degrees of freedom has been designed, and its dynamic characteristics predicted through mathematical modeling and computer simulations. Moreover, via an example it was shown how the yaw motion in particular can be independently controlled for future durability test despite strong kinetic couplings.

CFD Analysis for Concept Design of Air Levitation Transport System (공기부양 이송시스템 개념설계를 위한 전산유동해석)

  • Chang H.S.;Park Y.J.;Chang Y.S.;Choi J.B.;Kim Y.J.;Chun P.H.;Kong J.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.81-82
    • /
    • 2006
  • Conveyor-type transporters have been widely used as a typical delivery system of semi-conductor, FPD and other IT-related products. However, as the IT-product is getting larger in size and higher in resolution, several problems are caused by mechanical contacts between the transporter and target object. In this context, recently, lots of efforts are being devoted for development of various contact-free handling systems to get rid of deffets and oil contaminations. The objectives of this paper are to characterize suspension mechanisms and to investigate air flow effects on air levitation transport system. For this purpose, a series of CFD analyses were carried out and the simulation data showed a good agreement with the corresponding experimental ones. It is anticipated that the promising result can be used as a basis for concept design of the transport system.

  • PDF

Characteristics of First Flush in Highway Storm Runoff (강우시 발생하는 고속도로 유출수의 초기우수 특성 및 기준)

  • Kim, Lee-Hyung;Kang, Joohyon
    • Journal of Korean Society on Water Environment
    • /
    • 제20권6호
    • /
    • pp.641-646
    • /
    • 2004
  • Vehicle emissions from highway landuse include different pollutants such as heavy metals, oil and grease and particulates from fuels, brake pad wear and tire wear. Since highways are impervious and have high pollutant mass emissions from vehicular activity, it is considered as stormwater intensive landuses. Therefore this research was performed to understand the magnitude of first flush and to suggest the criteria of first flush for storm runoff management in highways. The fractions of washed-off mass are very high in first 30% of runoff volume, which suggests a definition of first flush. The washed-off mass stabilizes after 30% of the runoff volume and it is apparent that treatment capacity in the early part of a storm is more valuable than treatment capacity in the later part of the storm. Using the criteria of "high" first flush and "medium" first flush, as 50% of the mass in the first 30% of the volume, and 30 to 50% in the first 30% volume, respectively, more than 30% of the storms showed high first flush. A "first flush friendly" best management practice(BMP), meaning a BMP that can treat a high percentage or all of the initial flow, would be advantageous up to 80% of the events.