Browse > Article
http://dx.doi.org/10.5573/ieie.2016.53.10.095

False Alarm Filtering Algorithm Development of Pipeline Leak Detection System using Flow Volume Balance  

Kim, Min-Sung (서울시립대학교 전자전기컴퓨터공학과)
Kim, Hie-Sik (서울시립대학교 전자전기컴퓨터공학과)
Jung, Hae-Kyun (SK주식회사, 에너지화학사업2팀)
Publication Information
Journal of the Institute of Electronics and Information Engineers / v.53, no.10, 2016 , pp. 95-102 More about this Journal
Abstract
Pipeline is making the most use of transportation of petroleum products on the land. But due to tremendous accident or environmental disaster by oil pipeline leak or pipeline stolen, leak detection systems have been used for preventing it. Leak detection method based on negative pressure wave has been used at the long distance pipeline. But even if it has showed good leak detection quality, due to making a lot of false alarm, it has weak point that disturbs concentration to system. This study suggests algorithm and method of using volume balance to decrease false-alarm of pipeline leak detection system based on negative pressure wave.
Keywords
LDS; Pipeline; Leak Detection; Volume Balance; Negative Pressure Wave;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Korea Petroleum Association, http://www.petroleum.or.kr/201007/infozone/knowledge/knowledge.jsp?menu=1§ion=8&htnum=8&imgnum=1
2 J. Zhang, "Design a Cost Effective and Reliable Pipeline Leak Detection System", Pipeline Reliability Conference, November 1996.
3 W.Y.Kim, T.W.H, and J.M.Ha, "Analysis of Propagation of Negative Pressure Wave Due to Leak Through Damaged Hole in High Pressure Piping System", Journal of Fluid Machinery, Vol. 11, no. 1, pp. 26-32, February 2008.   DOI
4 Reinaldo A.Silva, "Pressure wave behavior and Leak detection in Pipelines", Computer & Chemical Engineering, Vol. 20, Supplement 1, pp. S491-S496, May 1996.   DOI
5 Alaska Department of Environment Conservation, Technical Review of Leak Detection Technologies, pp. 3-7, 1999.
6 Min-Sung Kim, Hie-Sik Kim; "Study on Flow Volume Balance of Pipeline Leak Detection System based Negative Pressure Wave" Conference on Information and Control System, October 2015.
7 The Korea Occupational Safty and Health Agency; "Guideline for Source Term Modeling" http://www.kosha.or.kr, December 2000.
8 Min-Sung Kim, Hie-Sik Kim; "Estimation Method of Leak Volume of Pipeline Leak Detection System using Volume Balance for Leak Triggering Distinction" International Conference on Mechatronics and Information Technology, December 2015.
9 James Doorhy; "Real-Time Pipeline Leak Detection And Location Using Volume Balancing" Pipeline & Gas Journal, Vol. 238, no. 2, pp. 65, February 2011.