• 제목/요약/키워드: Oil filled cable

검색결과 35건 처리시간 0.027초

345 kV OF cable의 개발 (Development of Oil Filled Power Cable for 345kV Line)

  • 한기만;최명규;이인호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.224-228
    • /
    • 1988
  • Extensive development work which was carried out by Gold Star Cable Co., Ltd. has led to the optimal design, manufacture and test of fully engineered cable system for 345 kV self- contained oil filled (OF) underground cable. Details of design criteria and of tests are given. development of 345kV OF cable results in sucessful operations for ultra-high voltage power transmission requirement.

  • PDF

지하 전력구내 OF 케이블의 화염전파속도 특성 실험 (Experiment on the Characteristics of Surface Flame Propagating Velocity of Oil filled Cable in the Underground Utility)

  • 이재하;정진용;홍기배;유홍선
    • 한국안전학회지
    • /
    • 제20권2호
    • /
    • pp.44-49
    • /
    • 2005
  • Real-scale experimental study was performed to characterize the surface flame propagating velocity along the OF cable in the underground utility fire. Temperatures of oil filled OF cable and dried OF cable with the diameter of 90mn were measured using thermocouple and data log system. The hexane and alkyl-benzene oil were used as a fire source using the ignition device. As a result while the surface flame propagating velocity of the three cables was $0.06\~0.09cm/s$, the surface flame propagating velocity of the one cable was $0.028\~0.032cm/s$. Therefore, it was found that the surface propagating flame velocity of the three OF cables is $2.1\~2.8times$ faster than that of one OF cable case. The results show that the surface propagating flame velocity became larger as increase of the number of cable, the volume of alkyl-benzene oil in the cable. The characteristics of surface propagating flame velocity in the OF cable can be helpful to fire suppression system in utility.

지중송전케이블 접속부에서의 열전달에 관한 연구 (A Study on Heat Transfer of an Underground Power Transmission Cable-Joint)

  • 박만흥;김재근;이재헌
    • 설비공학논문집
    • /
    • 제5권4호
    • /
    • pp.265-277
    • /
    • 1993
  • Recently, underground transmission system is growing continuously according to the electric power demand increase in the downtown area. Even if domestic cable makers are manufacturing 154kV oil filled cable and joint, the design technology of cable-joint has not been fully self-reliance. This study is aimed at the detail heat transfer analysis of 154kV cable-joint. So, that is cut into the five sections in order to analyze a conjugate natural convection in two dimensional $r-{\theta}$ coordinate. The streamline and temperature distributions are obtained for each sections. Also the changes of those are analyzed with respect to the variation of transmission currents and cable-joint surface heat transfer coefficients. The same analyses are also shown in view point of the maximum temperature of conductor and local equivalent conductivity.

  • PDF

초고압 OF 케이블 급유계통의 조기이상검지시스템 (New leakage detection system for the hydraulic system of EHV underground oil-filled cables)

  • 김영;성정규;한창석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1966-1968
    • /
    • 2000
  • Globally, oil-filled paper-insulated cables and cross-linked polyethylene-insulated cables have been mainly applied for a underground power transmission line. The oil-filled cable has the hydraulic system in which insulating oil, expanded and contracted by temperature changes, is absorbed and supplied. This system enable us to detect oil leakages from the cable. But it has some problems such as difficulty in detecting minor leakages and a relatively long period of fault detecting. And so, this paper introduce a new leakage detection system, improved from the current one.

  • PDF

OF 케이블 절연유 가스분석을 통한 고장예방 (The prevention of Fault by Analyzing the Gas in Oil of Oil-Filled Cable System)

  • 김두진;김재승;윤종건
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.444-445
    • /
    • 2008
  • This paper reviews the known techniques for diagnosing the condition of OF cable system and improving the service reliability. These tests are periodically achieved and intended to provide indications that the insulation system has deteriorated. One of these tests is analyzing the gas in oil on Oil-filled cable that is well known and widely accepted method. In this paper, this method of analysis and the relevant measurement standards overview and the concrete example of preventing fault incidence by performing this test is introduced.

  • PDF

젤리충전통신케이블의 구리회수를 위한 친환경적 분리기술평가 (Evaluation of Separation on the Copper Recovery from Jelly filled type Cable)

  • 민달기;성일화
    • 환경위생공학
    • /
    • 제18권3호통권49호
    • /
    • pp.21-26
    • /
    • 2003
  • The generation of waste cable has been continuously increased as a production of electrical and communication media are extended. The current recovery methods, such as mechanical peeling, incineration, solvent extraction and pyrolysis, seems inadequate because they are either hard to apply in some cases or environmentally unacceptable. It has been shown that copper can be effectively separated from the jelly filled type cables using a soybean oil treatment method. As a result, jelly compound is vanished from the wire by soybean oil bath and waste wires are separated copper and PE by the mechanical chipper. This is a more environmentally friendly method than burning, and considerably faster than Stripping.

초고압 지중 OF 케이블 접속재의 전계해석에 관한 연구 (A Study on the Electric Field Analysis of Extra-High Voltage Oil-Filled Cable Accessories)

  • 이종범;강동식;강도현;이수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.432-435
    • /
    • 1989
  • This paper presents an algorithm for electric field analysis which is essential to insulation design of extra-high voltage oil-filled cable accessories using finite element method. Governing equation is induced by electromagnetic equation. Variational method is adopted for FEN formulation. Automatic mesh generation which saves time and labor is introduced for the input data. The application results of proposed algorithms were used for insulation design to develop 345kV cable joint.

  • PDF