• 제목/요약/키워드: Oil charge

검색결과 126건 처리시간 0.042초

유동 대전된 절연유의 제전 방식중 침전극 삽입의 영향(II) (The Effect of Needle Electrode in the Static Charge Elimination Methods for Streaming-Electrification Insulating Oil)

  • 조영규;김용운;임현찬;김두석;신용덕;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.624-626
    • /
    • 1993
  • The Electrical Charge generated by friction in flowing insulating oil can create hazadous accidents. Neutralization of static charges in the oil during transportation is an obvious method of overcoming the problem of internal electric charge. It is known that SCR(Static Charge Reducer) can neutralize much of this charge by the needle electrode and mixing it with the original charge. In our experiment, a filter to generate static charge was set just befor a measurement pipe, and streaming current from the filter to the earth $I_s$, current from the electrode to the earth $I_e$ and current from the receiving tank to the earth $I_f$ were measured in a steady state. As a result, charge density and needle electrode current increases with increasing of oil temperature. Charge elimination rate decreases with increasing of oil flow rate, and increases with increases of oil temperature. Faraday Cage current decreases with increasing of oil temperature.

  • PDF

냉동기유 주입량과 냉매 충진량에 따른 냉동기 성능 평가 (Effects of Refrigerant and Oil Charges on the Performance of an Refrigeration System)

  • 선종관;채수남;정동수
    • 설비공학논문집
    • /
    • 제14권8호
    • /
    • pp.617-625
    • /
    • 2002
  • In this study, effects of refrigerant and oil charges on the performance of a refrigeration system simulating an automobile air conditioner have been experimentally investigated using R134a and PAG oil. Measurements were taken in a breadboard type refrigeration test unit with a compressor used for a commercial automobile air-conditioner under a set of condition imposed upon normally to automobile air conditioners. Both the COP and capacity decreased rapidly as the oil charge increased because of the decrease in vapor pressure of the circulating refrigerant/oil mixture. The excess oil left in the evaporator also caused heat transfer degradation resulting in a decrease in capacity and in turn COP. It was found that there is an optimum refrigerant charge at which the COP becomes the maximum. Below this optimum charge, both the capacity and COP increased as the refrigerant charge increased and above the optimum charge, both of them remained almost constant. Hence, the COP seems to be the most important factor in determining the optimum refrigerant charge. When the system was undercharged, the refrigerant at the condenser exit lost subcooling and showed a sign of poor miscibility.

Space Charge Behavior of Oil-Impregnated Paper Insulation Aging at AC-DC Combined Voltages

  • Li, Jian;Wang, Yan;Bao, Lianwei
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.635-642
    • /
    • 2014
  • The space charge behaviors of oil-paper insulation affect the stability and security of oil-filled converter transformers of traditional and new energies. This paper presents the results of the electrical aging of oil-impregnated paper under AC-DC combined voltages by the pulsed electro-acoustic technique. Data mining and feature extractions were performed on the influence of electrical aging on charge dynamics based on the experiment results in the first stage. Characteristic parameters such as total charge injection and apparent charge mobility were calculated. The influences of electrical aging on the trap energy distribution of an oil-paper insulation system were analyzed and discussed. Longer electrical aging time would increase the depth and energy density of charge trap, which decelerates the apparent charge mobility and increases the probability of hot electron formation. This mechanism would accelerate damage to the cellulose and the formation of discharge channels, enhance the acceleration of the electric field distortion, and shorten insulation lifetime under AC-DC combined voltages.

Space Charge Behavior of Oil-paper Insulation Thermally Aged under Different Temperatures and Moistures

  • Zhou, Yuan-Xiang;Huang, Meng;Chen, Wei-Jiang;Jin, Fu-Bao
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1124-1130
    • /
    • 2015
  • Moisture and high temperature are the most important factors that lead to the ageing of oil-paper insulation, but the research about space charge characteristics of oil-paper insulation does not take the combined effect of ambient temperature, moisture and thermal ageing into account. The pulsed electroacoustic (PEA) method was used to investigate the influence of moisture and temperature on space charge characteristics of oil paper at different ageing stages. The results showed that moisture could speed up formation of space charge in oil paper when water concentration was low, but the formation was restrained if the water concentration was high. At the beginning of thermal ageing, heterogeneous charge accumulation had predominance, but it gradually changed to homogeneous charge injection with ageing. It was believed that moisture concentration could speed up ageing and enhance charge accumulation on one hand, and accelerate or slow down the establishment speed of space charge on the other hand, therefore, charge accumulation type changed with ageing. The more seriously the oil-paper insulation was thermally aged, the deeper the trap energy level was, hence more space charge was trapped, which could be speeded up by increasing the ageing temperature, but the effect of ambient temperature did not fit the Arrhenius law.

변압기 절연유의 순환 계통에서의 흐름 조건의 개선에 의한 유동대전현사의 완화 방법에 관한 연구 (A Study on the Method for Mitigation of Streaming Electrifiction by the Improvement of Flow Condition in the Oil Folw System of Transformer)

  • 권석두;남상천
    • 대한전기학회논문지
    • /
    • 제43권4호
    • /
    • pp.594-600
    • /
    • 1994
  • The maximum charge accumulation in transformers caused by streaming electrification is commonly observed on the bottom area of transformer winding(i.e.the oil inlet of transformer winding). It is because turbulent flows occur in this portion of transformers. Consequently, if we are to reduce the maximum charge accumulation of transformers, it is important that we should have a good understanding of the conditions of the occurence of partial turbulent flows in the oil inlet of transformer winding. With this point in mind, a simple flow model was designed in this study in order to simulate oil flow in the insulation ducts of power transformers. As a method for mitigating charge accummulation, attention was given to (a) a flow path design for the improvement of flow conditions, and (b) the charge tendency of the material used this design. The results of this study show that the above method is useful for mitigating charge accumulation.

  • PDF

Influence of Electrical Aging on Space Charge Dynamics of Oil-Impregnated Paper Insulation under AC-DC Combined Voltages

  • Wang, Yan;Li, Jian;Wu, Sicheng;Sun, Peng
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1512-1519
    • /
    • 2013
  • Oil-impregnated paper is a major type of insulation used in oil-filled converter transformers for both traditional and new energy systems. This paper presents and analyzes the results of the experiment conducted on the electrical aging of oil-impregnated paper under AC-DC combined voltages using the pulsed electro-acoustic (PEA) technique. The formation and dynamics of space charge affected the performance of insulation material. The electrical aged oil-paper insulation was obtained through electrical aged experiments under the voltages. Based on the PEA technique, measurements were carried out when the oil-paper insulation system was subjected to different stressing and aging times. The space charge dynamics in the bulk of the oil-paper insulation system with different aging times were measured and analyzed. Characteristic parameters such as the total charge injection amount, the total charges of fast moving and slow moving, and the distortion factor of electric field were calculated and discussed. Results show that the longer electrical aging time, the more charges trapped in the bulk of aging sample. It leads to larger distortion factor of electric field in the bulk of aging samples and accelerate degradation of oil-paper insulation under AC-DC combined voltages.

Comparative Study of DC Breakdown and Space Charge Characteristics of Insulation Paper Impregnated with Natural Ester and Mineral Oil

  • Hao, Jian;Zou, Run-Hao;Liao, Rui-Jin;Yang, Li-Jun;Liao, Qiang;Zhu, Meng-Zhao
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1682-1691
    • /
    • 2018
  • Natural ester is a suitable substitute for mineral oil and has been widely used in AC transformer in many countries. In order to further application of natural ester in direct current (DC) equipment, it is needed to investigate its long term insulation property under DC condition. In this paper, a thermal ageing experiment was conducted for both mineral oil-paper and natural ester-paper insulation. The DC breakdown and space charge characteristics of insulation paper impregnated with natural ester and mineral oil was compared. Results show that the resistivity of the paper immersed in natural ester and mineral oil both increase as the ageing goes on. While insulation paper impregnated with natural ester has higher resistivity and DC breakdown voltage than the paper impregnated with mineral oil. The DC breakdown voltage for the oil impregnated insulation paper being DC pre-stressing is higher than that without pre-stressing. The average DC breakdown field strength difference between the test with pre-stressing and without pre-stressing clearly shows that there is an apparent enhancement effect for the homo-charge injection on the DC breakdown.

대전된 절연유에 의한 제전관내 침전극의 전위변화에 관한 연구 (The Study on the Electric Potential Variation of Needle Electrodes by Charged Insulating Oil in the Charge Reducer)

  • 김영일;김영봉;김두석;박재윤;조영규;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1583-1585
    • /
    • 1994
  • In this paper, we investigated the relationship between the needle electrode current and the needle electrode potential, The needle electrode potentials have influence on the needle electrode currents absolutely. So, to increase the needle electrode currents there is necessary to keep a high electric field if the charge reducer. for this, high insulation materials must be selected, and charge density of insulating oil must be high. In this experiment, the more a charge density of insulating oil increases, the more a needle electrode potential increases. So we could know what increasement of needle electrode potential increases a needle electrode current.

  • PDF

평등전계에서 도전성 구형 입자의 운동 (Motion of Conductive Spherical Particle under Uniform Electric Field)

  • 임헌찬
    • 조명전기설비학회논문지
    • /
    • 제25권8호
    • /
    • pp.39-47
    • /
    • 2011
  • The motion of a conductive spherical particle under uniform electric field is investigated in order to find a suitable method for removing the conducting solid impurities contained in liquid plastic. When the positive dc voltage applied to the upper electrode, the vertical up-and-down motion of a charged particle by electrostatic force is observed by a charge-coupled device (CCD) camera or a high-speed video camera. The experimental data of the static threshold voltage by which the particle starts to move toward the counter electrode in air or silicone oil are in good agreement with theoretical value. When the applied voltage is larger than the static threshold voltage, the particle motion pattern in silicone oil consists of four stages: upward motion, stopping at the upper electrode, downward motion and stopping at the lower electrode. The stopping motion on the electrode is thought to be caused by the liquid flow accompanied by the particle motion. The particle charge calculated by integrating the pulse current, which is generated by the charge exchange between the electrode and the particle, is approximately 0.1~0.25 times of the theoretical value. This study is expected to help understand the electric properties of microparticles in oil circuit breaker (OCB) and oil transformer and improve their performance and longevity.

세관을 흐르는 절연유의 유동대전에 의한 대전전하의 제전방법에 관한 연구 (A Study on the new method of electrostatic elimination in oil flowing pipe.)

  • 소금실성;박재윤;이덕출;황명환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.129-131
    • /
    • 1990
  • When insulating oil is flowed through a pipe, the electrostatic charge in the oil will be increased. Using inflammability oil, an electrostatic phenomena which may cause significantly problems as explosion must be circumvented by some methods. In this paper we made a new electrode which was applied AC field to the flowing oil for reducing electrostatic charge. Before we developed the new method of an electrostatic elimination, the electrification experiment was performed by using the same electrode which was supplied DC voltage to realize electrified conditions. As a result of this study, the effect of the electrostatic elimination could be observed.

  • PDF