• Title/Summary/Keyword: Oil Temperature Variation

Search Result 145, Processing Time 0.03 seconds

Erosion Damage of Ultrasonic Vibrator Tip in Marine Sludge Oil Environment -as for oil temp. change- (선박 슬러지유 환경에서의 초음파진동자 선단의 침식손상(1) -유온도의 변화에 대해서-)

  • 이진열;정지선;하만식;한원희
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.7 no.2
    • /
    • pp.1-11
    • /
    • 2001
  • Many investments and works being continued to preserve green ocean in each countries of the world. Especial1y, the researches on the prevention of marine oil pollution being strengthened. It is not easy to disclose sludge oils that were produced necessarily in the ships operation, so that they are transferred to shore treating facility after collected inside the ship's sludge tank mostly. However, this shore transferring method is not only costly and time consuming but also entails risk of oil pollution. In this regard, it will be the best way to manage the sludge oils inside ship itself. The purpose of this study is to device an ultrasonic breaking systems which recycle the sludge oil from ships into usable oil to be burnt. In this paper, the first place, matrix structures of sludge fuel oil(SFO) and sludge lubricating oil(SLO) with the irradiation time for ultrasonic vibrator were interpreted. And, erosion damage for vibrator horn tip which is one of important part of ultrasonic breaking systems was examined under such an environment of the sludge oils. The material for horn tip is being made of SS41 steel and its erosion phase was investigated with variation of the vibration amplitude of 50${\mu}{\textrm}{m}$ and 24${\mu}{\textrm}{m}$ as well as the change of temperature in the oil environments. It is suggested that the experimental results can be helpful to the development of sludge oil disposing systems for the vessel.

  • PDF

Temperature-Viscosity Characteristics of Hydrous and Anhydrous Electro-Rheological Fluids (함수계와 비수계 ER유체의 온도-점도 특성)

  • 이진우;장성철;염만오;김도태;박재범
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.451-456
    • /
    • 2002
  • This paper describes the properties of Temperature-Viscosity characteristics of hydrous and anhydrous ER fluids containing starch and titanium particle in silicone oil. ER effects arise from electrostatic forces between the starch particles and titanium particles dispersed in the electrically insulating silicone oil induced when electric field is applied. ER fluids under electric field have been found to provide resonable estimates of ER fluid viscosity variation characteristics. Yield shear stress of the ER fluids were measured on the couette cell type rheometer as a function of electric fields. The outer cup is connected to positive electrode(+) and bob becomes ground(-). The electric field is applied by high voltage DC power supply. In this experiment shear rates were increased from 0 to 200/equation omitted/ in 2 minutes.

  • PDF

Remediation of Bunker Fuel Oil C Contaminated Soil with Microwave Radiation and Heating Elements (마이크로파 조사와 발열체를 이용한 벙커C유 오염토양의 복원)

  • Oh, Da-kyung;Lee, Tae-jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.8
    • /
    • pp.458-464
    • /
    • 2015
  • Total petroleum hydrocarbon (TPH) removal and temperature variations in bunker fuel oil C contaminated soil were investigated by using microwave radiation in the presence of triiron oxide or activated carbon as a heating element. Temperature increments of $1.4{\sim}1.6^{\circ}C/Watt$ were observed, when 100~500 watt of microwave radiation was applied for the contaminated soil in the presence of triiron oxide or activated carbon. Temperature variation of the soil was more rapid in the presence of triiron oxide than activated carbon. 10% or 25% of heating element content was required to reach the temperature of thermal desorption for triiron oxide and activated carbon respectively. After radiation, 44.1% and 89.4% of initial TPH in soil was removed in the presence of triiron oxide and activated carbon respectively. It was observed that activated carbon was more reactive than triiron oxide for the removal of high molecular carbon of bunker fuel oil C.

Effect of Seeding Time on Fatty Acid Composition, Oil Contents and Seeds Yield in Flax

  • Choi, Hong Jib;Park, Shin Young;Kim, Sang Kuk
    • Korean Journal of Plant Resources
    • /
    • v.25 no.6
    • /
    • pp.700-706
    • /
    • 2012
  • Influences of different seeding dates on growth, seed yield, fatty acid composition and oil content were investigated in flax plants for two years. The results indicated that plant height in early seeding date was higher than that of delayed seeding dates during first season. Furthermore, seeding date also significantly affected the ripened seed rate and the rate increased with the delay in seeding date in first season. Seed yield in the first crop season was significantly higher than the second crop season. Palmitic acid showed variation in different seeding dates. Contrarily, stearic acid was stable and did not changed by different seeding dates. Linolenic acid was found in highest amount in all seeding dates consecutively in two cropping years. Highest oil content was recovered from the seeds of flax sown at 29 Apr. and May 9 in first and second cropping year respectively.

The Study of Oil Oxidation in Storage of Yackwa (약과 저장에 있어서 지방산화에 관한 연구)

  • Yum, Cho-Ae
    • Journal of Nutrition and Health
    • /
    • v.5 no.2
    • /
    • pp.69-74
    • /
    • 1972
  • The study was made for storage test of Yackwa, which is typical cookies of Korea and contain about 20% of vegetable oil. As the result of investigation the variation of POV and AV of oil contained in Yackwa which was stored in packed or unpacked state for 60 days, at the temperature of $5^{circ}C$ or $30^{circ}C$ respectively, it was found that the Yackwa of AV, about 2, and POV, about 20, was considerably stable for storage. This result of the good storage condition of Yackwa containing a considerable amounts of Vagetable oil which proceed the rancidity, is derived from the formed film on the surface of Yackwa by the sugar syrup afterwards.

  • PDF

Cooling Performance Test of 2-stage Heat Pump System Using River Water as a Heat Source (하천수율원이용 2단압축 열펌프시스템 냉방성능평가)

  • Kim, J.R.;Lee, Y.S.;Jang, K.C.;Ra, H.S.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2129-2134
    • /
    • 2004
  • The present study has been conducted to develop a heat pump system using river water of temperature energy which not only belongs to unutilized energy but is a kind of good heat source due to maintain its temperature in a certain degree regardless of seasonal variation. The system did not meet the proposed performance after setup. In this paper, the system performance affected by refrigerant Oil, by pressure drop, or by other factors has been discussed. The followings were obtained : (1) Refrigerant Oil mixture rate was 2.5 in weight percentage, (2) Pressure drop through evaporator was 29.1kPa($3.1^{\circ}C$ in saturated tempearture) (3) Pressure drop from the end of evaporator to compressor inlet was 39.8kPa($4.0^{\circ}C$ in saturated tempearture). (4) The system performance can to be improved by modifying a part of pipe line to compressor, and reducing pressure drop through heat exchangers.

  • PDF

An Experimental Study on Non-hygroscopic Propertiy of PAG and POE Oils for a $CO_2$ Refrigeration System ($CO_2$ 냉동시스템용 PAG오일과 POE오일의 항흡습성에 관한 실험적 연구)

  • Lee, Sung-Kwang;Kang, Byung-Ha
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.6
    • /
    • pp.388-393
    • /
    • 2008
  • This study has been conducted to select the suitable refrigeration oil for a $CO_2$ refrigeration system. Non-hygroscopic property of refrigeration oils is one of the most important properties for refrigeration oils. PAG and POE oils are considered as test oils in this study. Transient variation of water content of PAG and POE oils was measured for 3 different vessels in the environmental conditions, such as in the range of temperature $25^{\circ}C$ to $40^{\circ}C$ and relative humidity 40% to 85%. The results obtained that water content of both POE and PAG is increased with an increase in the contact area with ambient for 3 different vessels. It is also found that water content of both POE and PAG is increased as the ambient temperature and relative humidity is increased. Non-hygroscopic property of POE oil is found to be much superior than that of PAG oil.

The Effect of Ultrasonic Cavitation on the SS400 in Marine Sludge Oil (선박 슬러지유 환경에서 초음파 캐비테이션이 일반강에 미치는 영향)

  • Han Won-Hui
    • Tribology and Lubricants
    • /
    • v.22 no.4
    • /
    • pp.218-224
    • /
    • 2006
  • The sludge oils were produced necessarily in the ships operation, so that it will be the best way to manage the sludge oils inside ship itself from a viewpoint of the prevention of marine oil pollution. The ultra-sonic breaking system which recycle the sludge oil from ship into usable oil to be brunt is recognized as a most possible recycling device. In this regards, the purpose of this study is to examine erosion damage,on the SS400 specimen by cavitation and the effect of impact pressure generated from the demolition of the cavity of ultrasonic vibration in the marine sludge oil environment.. The erosion damage of specimen was investigated mainly on weight loss, weight loss rate and maximum erosion rate with variation of the oil temperature as well as the change of space between transducer hem and specimen. The experimental results showed that as the space between ultrasonic vibrator horn and specimen disk increased, the weight loss and weight loss rate decreased and the values were larger in SFO than in SLO. The experimental results can be useful to the development of sludge oil disposing systems and to consider a countermeasure for the prevention of erosion damages by cavitation.

Experimental Study on Effects of PAG Oil for $CO_2$ Evaporation Heat Transfer (PAG 오일이 $CO_2$ 증발열전달에 미치는 영향에 관한 실험적 연구)

  • Lee, Sang-Jae;Kim, Dae-Hoon;Choi, Jun-Young;Lee, Jae-Heon;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.5
    • /
    • pp.357-363
    • /
    • 2008
  • In order to investigate $CO_2$ heat transfer coefficient and pressure drop by PAG oil concentration during $CO_2$ evaporation, the experiment on evaporation heat transfer characteristics in a horizontal micro-fin tube was performed. The experimental apparatus consisted of a test section, a DC power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. Experiment was conducted for various mass fluxes($400{\sim}1200\;kg/m^2s$), heat fluxes($10{\sim}30\;kW/m^2$) and saturation temperatures ($-5{\sim}5^{\circ}C$), and PAG oil concentration($0{\sim}5\;wt%$). The variation of the heat transfer coefficient was different in accordance with the oil concentration. With the increase of the oil concentration, the evaporation heat transfer coefficient decreased and the delay of dryout by oil addition was found. Pressure drop increased with the increase of the oil concentration and heat flux, and the decrease of saturation temperature.

A Study on the Deterioration Diagnosis Device of Pole Transformer using FFT (FFT를 이용한 주상 변압기의 열화 진단 장치에 관한 연구)

  • 윤용한;김영춘;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.3
    • /
    • pp.97-106
    • /
    • 2000
  • This paper proposes on-line based a deterioration diagnosis device for diagnosis pole transformers using tan$\delta$ and FFT(fast Fourier transform). We measured tan$\delta$ and temperature to diagnose pole transformer insulating oil, diagnostic results are processed by FFT. For measuring convenience, we use R/F(radio frequency) wireless data communication module operating by secondary voltage of pole transformer. We have voltage variation test and oil temperature variation test to prove usability of proposed diagnosis device. The result of this paper shows that the proposed device can be used as deterioration diagnosis device of pole transformers.

  • PDF