• Title/Summary/Keyword: Oh Gyu-won

Search Result 292, Processing Time 0.024 seconds

Reduction of Aeroacoustic Noise from Intake Head of a Vacuum Cleaner (진공청소기 흡입유로의 공력소음 개선)

  • Koo, Jeong-Su;Hwang, Won-Gul;Oh, Il-Kwon;Oh, Jang-Guen;Song, Hwa-Gyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.202-207
    • /
    • 2006
  • The aeroacoustic noise from intake head of a vacuum cleaner is caused by complicated transient pressure fluctuation and it greatly affects the overall SPL of the vacuum cleaner. In this study, we intended to decrease the overall SPL by reducing the aeroacoustic noise from intake head. In the first the place, we analyzed the aeroacoustic noise from the unsteady fluid analysis of intake head. And then, we grasped the dominant frequency band from the aeroacoustic noise by comparing the spectrum distributions between examinations and analyses. Also, we systematically investigated the aeroacoustic noise sources from each part composing the intake head. Consequently, we redesigned each part of the dominant noise sources and suggested the modified intake head, resulting in the reduction ortho overall SPL by 3.6dB(A).

  • PDF

Limitations of Structural Behavior Response Performance Evaluation for Waterproofing Materials Under Non-Constrained Conditions and Suggestions for Future Improvement Measures (방수재료의 거동대응성능 시험시 비 구속조건에서의 구조물 거동 대응성능 평가의 한계와 향후 개선 방안 제안)

  • An, Ki-Won;Oh, Gyu-Hwan;Kim, Soo-Yeon;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.212-213
    • /
    • 2021
  • As structure and the waterproofing material are compressed through the backfilling process after the waterproofing material is installed on the underground structure at the actual site, there is a difference between the behavioral response force of the waterproofing material in the compressed state and the behavioral response force in the non-constrained state. In this regard, we will analyze the limitations of the current structural behavioral response evaluation and suggest an improvement plan so that the future test and evaluation environment can be evaluated under conditions similar to the field.

  • PDF

A Study on the Improvement of Cooling Efficiency for EMU by Changing the Operation Method of Line Flow Fans and Door Opening Systems (전동차의 라인데리아 및 출입문 작동 방법 변화를 이용한 냉방 효율 향상에 관한 연구)

  • Oh, Jun-Gyu;Won, Si-Tae;Nam, Seong-Won
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.94-99
    • /
    • 2011
  • EMU(Electric Multiple Unit) of Seoul Metro are equipped with air conditioning and six line flow fans for air circulation. In summer, the air conditioning and line flow fans usually work at the same time. Recently, high oil price leads more people to use public transportation, which in turn makes them feel hotter inside the rolling stocks and complain about air conditioning state. In order to improve indoor air quality in summer, it is inevitable to increase the cooling capacity of air conditioners, which costs a lot of money. Thus, we need to raise cooling efficiency by rearranging existing devices effectively. In this study, we found a better way to improve refreshment inside the trains by changing the operation method of line flow fans and door opening systems. The results will help improve the cooling efficiency of EMU in summer. Also, more precise experiments and analyses of our data can lead to various methods to increase energy efficiency.

  • PDF

The bibliographical study on the cause and symptom of Seup-Su(濕嗽) (습수(濕嗽)의 원인(原因)과 증상(症狀)에 대(對)한 문헌적(文獻的) 고찰(考察))

  • Oh, Young-Oug;Im, Il-Gyu
    • The Journal of Internal Korean Medicine
    • /
    • v.13 no.1
    • /
    • pp.110-116
    • /
    • 1992
  • This study has been carried out to investigate the cause and symptom of Seup-Su(濕嗽) by referring to 23 literatures. The results were as follows; 1. The factors causing Seup-Su(濕嗽) are divided into 3 groups. The 1st inner factor is lung affected by wetness(濕勝肺). The 2nd outer factors are wetness-evil(濕邪), syndrome caused by summer heat and wetness evils(暑濕), clothe after bath, sit down along the long time, symptoms caused by rain. The 3rd non-innwer and outer factor is the pholegm accumulated. 2. The symptom of Seup-Su(濕嗽) is as follows. arthralgia hidrosis difficulity in micturition pregnancy small tense pulse.

  • PDF

An Analysis of Clinical Characteristics of Patients with Cough by Food-accumulation and Yin-Deficiency (식적(食積) 및 음허(陰虛)로 인한 해수 환자의 임상적 특성 분석)

  • Lee, Jung-Wook;Park, Sang-Moo;Kang, Baek-Gyu;Han, Deok-Jin;Na, Ran-Hee;Bang, Chang-Ho;Jang, Seak-Oh;Son, Ji-Woo;Lee, Si-Hyeong
    • The Journal of Internal Korean Medicine
    • /
    • v.30 no.1
    • /
    • pp.85-93
    • /
    • 2009
  • Cough is a common clinical problem to which various etiologies are attributable. In Korean medicine there are differentiations in etiology such as food-accumulation and Yin-deficiency. This study was aimed to analyze the relations between the time of cough and Korean syndrome differentiations and to compare the symptoms of Korean syndrome differentiations (food-accumulation and Yin-deficiency). Sixty-two cough patients were analyzed and classified into one of two syndrome differentiations by etiology. We compared the time of coughing and symptomatic characteristics of two: such as symptom differences and change of severity after treatment. Patients with food-accumulation were more prevalent than patients with Yin-deficiency. Among symptoms, anorexia, dyspepsia, nausea and nasal discharge were more prevalent in food-accumulation while pruritus of throat was prevalent in Yin-deficiency. Coughing at night was prevalent in Yin-deficiency and coughing at rising hour was prevalent in food-accumulation.

  • PDF

Effects of Alkali Treatment of Soybean on the Qualty of Soybean Milk (대두(大豆)의 Alkali 처리가 두유의 품질에 미치는 영향)

  • Oh, Joon-Sei;Lee, Gyu-Hee;Lee, Won-Yong;Lee, Ka-Sun;Oh, Man-Jin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.17 no.2
    • /
    • pp.85-94
    • /
    • 1988
  • This experiment was carried out to obtain the basic data for removal the astringency and off-flavor in soybean milk, by means of soaking of soybean in NaOH and $NaHCO_3$ solutions. The changes of phenolic compounds in soybean during soaking were investigated with HPLC and also the changes of flavor and sensority of soybean milk, prepared from soaked soybean were studied. Phenolic compounds of soybean were identified as chlorogenic, p-hydroxybenzoic, p-coumaric, ferulic and gentisic acid and, chlorogenic acid content was greater than the others. The chlorogenic acid of soybean was mainly neutral type and the other compounds were almost acidic type. Up to 85% of the chlorogenic acid was removed by soaking of soybean in 0.1% of NaOH solution for 8 hrs. Phenolic compounds of soybean was almost removed by soaking in 0.1% of NaOH solution at $90^{\circ}C$ for 1 hr. Chemical composition of soybean milks prepared from soaking of soybean in water, 0.1% NaOH and 0.5% $NaHCO_3$ solution were similar. Hexanol content of beany flavor in soybean milk was increased by soaking of soybean in NaOH solution, where as hexanal, propanal, pentanal contents were removed up to 60%. Color of soybean prepared from soaking of soybean in NaOH solution at high temperature were deep yellow but were high whiteness in soybean milk prepared from soaking of soybean in water at low temperature. Sensority of soybean milk prepared from soaking of soybean in 0.1% of NaOH solution at $90^{\circ}C$ for 1 hr was more favorable than the others.

  • PDF

Analyzing the Change of Indoor Thermal Environment with the Introduction of the Water Space in Exterior Housing (주거 외부 수공간 도입에 따른 실내 온열 환경 변화 분석)

  • Oh, Sang-Mok;Oh, Se-Gyu;Won, Hyun-Seong
    • Journal of the Korean housing association
    • /
    • v.21 no.2
    • /
    • pp.41-48
    • /
    • 2010
  • This study shows how the water space outside the housing impacts the indoor thermal environment. CFD simulation was used for this experiment to analyze the interior environment focusing on the effect of temperature control and the thermal comfort. A shape of perfect square, which creates the very basic space formation, was used and the simulation was processed looking at the size, distance, and the location of the water space. The results of the experiment are as follows. Firstly, introducing a water space with the same floor area size of the simulation model decreased the indoor temperature by 1 Celsius (3.72%). It was determined the interior environment was considered as a comfort zone when the water space was greater than 70% of the floor area. Secondly, there was not much influence to the level of thermal comfort of the interior environment when the distance to the water space from the housing was greater than 2 meters. Lastly, interpreting the location of water space, the effect of controlling the total areas' temperature was the greatest following with the surrounding of the formation. There barely was any change to the temperature considering the side and the rear of the area.

A Design Guideline of Sign System Based on DPD Concept in Traditional Heritage Villages

  • Noh, Hwang-Woo;Kitagawa, Keiko;Yoo, Jae-Soo;Park, Sun-Gyu;Oh, Sang-Hoon;Min, Byung-Won;Oh, Yong-sun
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.19-20
    • /
    • 2015
  • Sign system currently used for traditional heritage villages in Korea does not have any well-defined concept and method so that somewhat improper signs can be developed like for general urban or tourism area. In this paper, we present a new method or guideline of sign system based on DPD(disaster prevention design) concept for our traditional heritage villages. We can enhance both safety of residents and satisfaction of visitors throughout this guideline. According to our investigations on the heritage villages, sign systems in Korea are mainly developed for tourism, on the other hand, sign development in Japan mainly focuses on prevention or protection against big disasters like earthquakes. Considering residents and their safety, we can submit a proper guideline to develop sign system for our traditional heritage villages based on the concept of DPD which can be applied to each space. Asan 'Oeam Village' and Beppu 'Onsen Village' are used as application sites compared between Korea and Japan.

  • PDF

Development of 1GHz High Speed Sampler for KVN

  • Kang, Yong-Woo;Song, Min-Gyu;Je, Do-Heung;Wi, Seog-Oh;Byun, Do-Young;Jung, Taehyun;Oh, Chungsik;Nam, Wook-Won
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.104.1-104.1
    • /
    • 2014
  • 한국우주전파관측망(KVN, Korea VLBI Network)의 우주전파수신시스템(22GHz, 43GHz, 86GHz, 129GHz의 4파수 동시관측 시스템)으로부터 수신된 전파신호를 디지털 신호로 바꾸어 주는 장치인 초고속 샘플러의 국산화와 성능 향상을 위하여, 우리는 1GHz 샘플링을 할 수 있는 전파관측 자료의 샘플링 장치를 설계, 제작하였다. GHz 샘플링 기본 기술 확보와 독자 개발을 위하여 제작된 1GHz 샘플러를 KVN울산전파천문대에 설치하여 관측 시험한 결과, 연구 관측에 적용할 수 있음을 보여 주었다. 한편, 광대역 관측과 e-VLBI 구현을 위하여 샘플러에서 직접 첨단망으로 VDIF(VLBI Data Interchange Format, VLBI 자료전송 규격)의 자료를 보낼 수 있는 차세대 4GHz 샘플러를 개발 중에 있다. 이번 발표에서는 1GHz 샘플러에 대한 개발 내용과 관측 결과 및 향후 계획을 소개한다.

  • PDF