• Title/Summary/Keyword: Office Lighting

Search Result 147, Processing Time 0.019 seconds

A Study on the Implementation of BPSK Demodulator with Remodulation Method for Power Line Carrier Communication (전력선 통신용 재변조방식의 BPSK복조기 실현에 관한연구)

  • 오상기;나채동;진달복
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.4
    • /
    • pp.38-45
    • /
    • 1994
  • It is very imprtant and necessary to predict luminous enviroment in an interior space. This paper has de scribed about energy saving and evaluated interior visual environment in a office building having on/off turning control lighting system utilizing daylight. In order to predict the interior varior illumination distribution, the scale model w a m~a de and examined under various conditions, such ad difference of window glass, and color pattern of wall, floor, and also ceiling lighting system type. Ths paper suggests that basic fundamental data of lighting design ~rformancein the concept and schematic stages of design.

  • PDF

A Study on the Illuminance Recommendations for a Museum Storage Area (수장공간의 조도기준에 대한 연구)

  • 김홍범
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.5
    • /
    • pp.1-6
    • /
    • 2002
  • Museum storage area is one of the most important places because collections are central to museums. However it is often misunderstood and treated as the storage areas of general office buildings md factories. In this paper, lighting design factors for museum storage areas are reviewed, and illuminance values for the various storage areas of the KS and the other countries'are compared and discussed in consideration of collections' management and conservation. And paying our due regard to collections management it is found that the standard illuminance value for museum storage area of the KS is lower than those of the other storage places. Therefore it is raised to 200[㏓]and supplementary lighting which can be controlled separatedly should be provided to increase the illuminance of task lighting.

Investigation of Lighting Environment in Office Rooms Equipped with High-Efficiency Lighting Products (고효율 조명기기를 이용하는 사무공간 조명환경 실태조사)

  • Oh, Hye-Young;Lee, Min-Uk;Min, Dae-Sik;Lee, Eun-Young;Kim, Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.135-141
    • /
    • 2007
  • 본 연구에서는 조명 환경의 영향을 크게 받는 사무 공간의 조명환경 실태를 조사하였다. 고효율 조명기기를 이용하는 사무 공간 내의 조도를 측정하고, 설문 조사를 실시하였다. 그 결과 대부분의 사무 공간이 KS조도 기준보다 높은 수준을 나타낸데 비하여, 균제도, 글레어(눈부심) 등 조명의 질적 요건에 대한 배려가 부족하여 시환경에 대한 평가는 좋지 않은 경향을 나타냈다.

  • PDF

Development of Multi-purpose Smart Sensor Using Presence Sensor (재실 감지 센서를 이용한 다용도 스마트 센서 개발)

  • Cha, Joo-Heon;Yong, Heong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.1
    • /
    • pp.103-109
    • /
    • 2015
  • This paper introduces a multi-purpose smart fusion sensor. Normally, this type of sensor can contribute to energy savings specifically related to lighting and heating/air conditioning systems by detecting individuals in an office building. If a fire occurs, the sensor can provide information regarding the presence and location of residents in the building to a management center. The system consists of four sensors: a thermopile sensor for detecting heat energy, an ultrasonic sensor for measuring the distance of objects from the sensor, a fire detection sensor, and a passive infrared sensor for detecting temperature change. The system has a wireless communication module to provide the management center with control information for lighting and heating/air conditioning systems. We have also demonstrated the usefulness of the proposed system by applying it to a real environment.

Tunnel Lighting Control by Luminance Sensor (휘도센서를 이용한 터널조명제어)

  • Eo, Ik-Soo;Lee, Eun-Poong;Park, Jun-Seok;Yeo, In-Seon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2165-2167
    • /
    • 2000
  • Until the first stage of the 1990's years. Korea are not concern so much the facilities of traffic tunnel, because of them are the short length and also the quantity of them are not over the several tens in korea, but in latest many tunnels has been constructed and are designed in expressway and local national loads, the government office concerned forecast the numbers of tunnel are increased about 300 until the 2003 years, and then we need more interesting about the facilities of tunnel in the tunnel, the first above of all important facilities is lighting installation which are required much electric energy and continuing maintenance.

  • PDF

Considering about lighting for concrete main structure using LED (LED를 이용한 등대 표체 경관조명에 관한 고찰)

  • Han, Ji-Ho
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2009.06a
    • /
    • pp.538-539
    • /
    • 2009
  • The light of lighthouse as aids to navigation has been using filament with incandescent bulb so heat is being changed to light. More and More, LED leading lights, LED lantern, LED concrete main structure, LED bulb which have advantages of low power consumption and longer durability, what we call radiating diode, will lead the market in few years.

  • PDF

A Study on The Integrated Simulation of The Intelligent Building Control Systems and Network (인텔리전트 빌딩의 제어 시스템 및 네트워크의 통합 시뮬레이션에 관한 연구)

  • Shin, Jin-Sok;Lim, Dong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.106-108
    • /
    • 1997
  • Many new office buildings are being built as intelligent buildings equipped with building automation(HA) systems, office automation(OA) systems, and telecommunication(TC) systems in order to provide pleasant building environment and the ease of maintenance and facility management. Building control systems which are employed in intelligent buildings require varieties of advanced control systems and network systems for efficient integrated management. Design and installation of these types of advanced building control systems take a lot of efforts and also they are costly. In order to design these systems, it is necessary for the designers to have the integrated simulator including proper network system simulation. In this paper, the integrated simulator that consist of HVAC system, lighting system, elevator system, parking system based on the network system is presented. For the development of integrated simulator, AHENA which is the general-purpose software tool for a simulation with reinforced GUI is used.

  • PDF

A Study on the Evaluation of Lighting Performance in an Office Space (사무공간의 조명성능 평가에 관한 연구)

  • 김한성;김영민;김강수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.16-22
    • /
    • 2003
  • The purpose of this study was to provide visual evaluation data in a workstation space when different lighting types were applied. For the performance evaluation, Radiance program was used for simulations, and the mock-up room(15.0x11.6x3m) was used for the actual test. The results of this study were as follows; 1) When the inidirect lighting simulation data using Radiance was compared with the actual data in a small workstation space, there was a 6.5% difference. Therefore, Radiance program was proved to be useful for the evaluation of lighting performance. 2) Higher light levels (higher light ratio (%)) were recorded in the straddled layout and lower light levels (lower light ratio (%)) were recorded in the centered layout condition in most cases. 3) Also, the results show that the indirect luminaires and the straddled layouts provide higher uniformity, whereas the direct luminaires and the centered layouts have lower uniformity.

A STUDY ON THE ILLUMINATION OF DENTAL CLINIC (치과 진료실의 조명에 관한 실태 조사연구)

  • Choi Jong-In;Kim Yu-Lee;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.374-382
    • /
    • 2006
  • Purpose: This study was designed to investigate the present conditions of illumination techniques in dental clinics in order to contribute improvement of operating environment. This study also aimed exploring qualitative and quantitative luminous intensity required for color temperature in dental clinic illumination, which was a critical part of esthetic dentistry. Materials and methods: A total of forty-eight local dental clinics were selected for sampling a) luminous intensity, and b) color temperature. The author measured the luminous intensity and the color temperature with lux meter and color meter respectively between 12pm and 2pm. The dental unit chair placed in the general operation positions were kept the distance 60 cm then all dental units were measured three times and averaged. The author measured the luminous intensity and color temperature with both common dental operating light and then without operating light in different office environments. The study was conducted under three conditions: 1 artificial illumination in clear day light 2. artificial illumination in cloudy day light, and 3. artificial illumination alone. Results : The results obtained were as follows. 1. The average luminous intensity in dental clinic lighting was 425 lux which was not sufficient to produce the optimal shade of the patient's teeth. Furthermore, the average luminous intensity even in full operating lighting was 9532 lux which fell short of the required level of 10,000 lux. 2. The average color temperature of all dental clinics surveyed was 5169 K which met the optimal range. However, only 33.3% fell in the correct region between 5,000-5,500 K as 25% were over 5,500 K and 41.6% were below 5,000 K. As a result, 66.7% were under insufficient color temperature conditions. 3. The dental unit chair placed next to a window, hence exposure to natural lighting, had significantly higher luminous intensity and color temperature compared to the dental unit chair which didn't have a window or natural lighting. 4. The data analysis revealed that only 6.3% of the dental clinic were met the standard of the average luminous intensity and color temperature.

Formative Expressions by Artificial Light applied to Office Building Lobbies (현대 오피스 로비공간에서 빛의 조형적 표현 특성에 관한 연구)

  • Jeong, Soo-Ryun
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.2
    • /
    • pp.41-49
    • /
    • 2009
  • Contemporary design environment is formed with image-centered trend based on pluralism. In this point of view, enterprises' building lobbies are public places containing the equivocal meaning, actively utilizing light as a design element to express the image of enterprises' identifications. Light is an immaterial entity having unlimited possibilities and potentials on space. It also acts as media to activate spaces and create new images in connection with formative elements of space. This study is to figure out how lightings are expressed and affected the formative characteristics of office lobby spaces and activate the specific characteristics of spaces. As a result, we drew conclusions as follows. First, as state-of-the-art technology and media are introduced, light is expressed on spaces as floating, direction, rhythm, silhouette, metaphor and allusion, sense of depth and volume. Second, expressive aspects of light in lobby space are embodiment of light, substantiation of immateriality, standing of materiality from the perspective of spatial aesthetics, and distortion/transformation of shape, pluralism phenomena of space from the perspective of spatial structure. In this way, light on building lobbies which are greatly required design differentiation strategy, specializes space and also integrates all the designs as not only a functional element but also a mental, psychological, formative element. Consequently, light on lobby spaces induces communication between spaces and users, makes formative value of existence in itself, and presents the characteristics of differentiated enterprises' identities.