• Title/Summary/Keyword: Office Automation

Search Result 198, Processing Time 0.032 seconds

Dynamic analysis of electromechanical system (기전 시스템의 동역학 해석)

  • 김진식;박정훈;임홍재
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1113-1118
    • /
    • 2004
  • This paper presents the dynamic analysis method for an electromechanical system. The engineer has at his disposal a variety of software simulation tools. However, difficulties arise when the study of the behavior of complex electromechanical systems in combination with coupling element is required. Typical examples of such systems are machines for factory automation, home automation, and office automation. Dynamic systems analysis packages or electronic systems analysis packages offer the restrictive to simulate these mixed systems such electromechanical product. Electronic circuit analysis algorithm is easily incorporated into a multi-body dynamics analysis algorithm. The governing equation of electronic circuit is formulated as a differential algebraic equation form including both electrical and mechanical variables and is simultaneously solved in every time step. This analysis method clearly demonstrates the application potential for mixed electromechanical simulation.

  • PDF

상하수도 종합정보시스템

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.256
    • /
    • pp.88-95
    • /
    • 1998
  • 상하수도사업은 안정되고 안전한 물의 공급에서부터 처리, 주위환경에 대한 배려, 고도 처리기술에의 대응 등은 물론, 경영의 관점에서 효율화와 코스트 삭감이 요구되는 가운데, 고도정보화를 위한 시책이 진행 중에 있다. 미쓰비시전기는 이전부터 ''상하수도종합정보시스템''으로 OA(Office Automation), EA(Engneering Automation), PA(Process Automation) 의 각 영역 그리고 전체로서의 효율화를 도모하는 시스템의 구축을 지향하여 왔다. 이 시스템의 특징은 다음과 같다. $\cdot$통합화(정보의 일원관리, 네트워크화)$\cdot$고도화(정보자산의 부가가치화)$\cdot$플렉시블 컨스트럭션(기존시스템 활용) $\cdot$토털효율의 향상(자동화, 무인화, 광역, 통합감시)본고에서는 모든 상수도$\cdot$하수도업무를 통괄함과 동시에 보다 종합적인 관점에서 지원하는 것을 베이스로 한 상하수도종합정보시스템에 대하여 소개하는데, 그 중에서도 통합화에 초점을 맞추어 다음과 같은 사항에 대하여 기술한다. (1) 그룹웨어의 상하수도분야에의 적용 (2) 휴대정보단말 ''상하수도수첩''에 의한 정보화범위의 확대 (3) ''인포하니스(Infoharness)''를 사용한 정보통합의 컨셉트 (4) 상하수도 조압정보시스템에서의 서브시스템 소개(우수배제지정시스템), 지역커뮤니케이션시스템)

  • PDF

Moving Path Following of Autonomous Mobile Robot using Fuzzy (퍼지를 이용한 자율이동로봇의 이동경로 추종)

  • 김은석;주기세
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.5
    • /
    • pp.84-92
    • /
    • 2000
  • Recently, the progress of industrialization has been taken concern of material handling automation. So for, the conveyor belt has been popular for material handling. However, this system has many disadvantages such as the space, cost, etc. In this paper, a new navigation algorithm using fuzzy is introduced. The mobile robot follows a line installed on the roads. These informations are inputted with three approximate sensors. These obtained informations are analyzed with fuzzy control technique fur autonomous steering. Therefore, unlike existing systems, high reliability is guaranteed under bad environment conditions. The installation and maintenance of a line is easily made at lower cost. This developed mobile robot can be applied to material handling automation in manufacturing system, hospital, inter-office document del ivory.

  • PDF

Visual Processing System based on Client-Server Model (Client-Server 모델에 의한 시각처리시스템)

  • Moon, Yong-Seon;Her, Hyung-Pal;Lim, Seung-Woo;Park, Kyung-Sug
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.2
    • /
    • pp.42-47
    • /
    • 1999
  • This paper suggests a model of a visual information system for factory automation. The model is composed of a visual processing system with client-server model and RPC(Remote Procedure Calling); a main server for controlling the whole factory automation process; and a processing server which processes the visual information only. To verify its efficiency, the suggested model is realized on the bill recognition system.

  • PDF

Ananalzing fault current and Protective coordination in the underground line (지중배전선로의 고장전류 크기 및 보호협조분석)

  • Cho, Nam-Hun;Ha, Bok-Nam;Lee, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.932-934
    • /
    • 1998
  • Electric power distribution feeders are susceptible to faults caused by a variety of situations such as adverse weather conditions, tree contacts, equipment failure, accidents, etc. Distribution circuit faults result in a number of problems related to the reliability of service and customer power quality. In the past, the permanent interruption of customer service resulting from a blown fuse or a recloser lockout was the only factor which was used to determine service reliability. So we developed KODAS(Korea Distribution Automation System) with successful and had fieid-testing of Distribution Automation System in last three years at Kang-dong Branch Office. In performing the project, KEPRI has gained valuable experience, through dealing with many difficult problem. This paper is depicted about the circuit breaker coordination problems in the Underground for the Distribution Automation Feeder.

  • PDF

Propagation of Lightning Surges toward primary Side of Distribution Transformer (배전용 변압기 고압측으로의 뇌서지 전파)

  • 이복희;이수봉;김병근;이승칠;이동문;정동철
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.269-272
    • /
    • 2003
  • The importance of the improving quality of electric power is being strongly raised, owing to an increasing use of sensitive and small-sized electronic devices and system. The transient overvoltage on low-voltage AC power distribution system are induced by direct or indirect lightning return strokes, and those can cause damage and/or malfunction of the utility system for borne automation, office automation and factory automation as well as medical equipments. The behavior of lightning surge transferred to the primary side from the primary side in distribution transformers were experimentally investigated the protection effect of low voltage SPD installed at the secondary side of distribution transformers was analyzed.

  • PDF

A Study on the Implementation of a microcomputer network (마이크로 컴퓨터 통신망의 구성에 관한 연구)

  • 송기열;유인청;정재일;최은호;백제인;김재균
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1984.04a
    • /
    • pp.63-65
    • /
    • 1984
  • A microcomputer network is designed and implemented for office automation in a small organization. It is a centrally controlled multidrop type, which connects many CP/M-baseed slave computers with a MP/M-based master computer.

  • PDF

Trends Analysis and Future Direction of Business Process Automation, RPA(Robotic Process Automation) in the Times of Convergence (융복합 시대의 비즈니스 프로세스 자동화, RPA(Robotic Process Automation) 동향분석 및 미래방향)

  • Hyun, Young Geun;Lee, Joo Yeoun
    • Journal of Digital Convergence
    • /
    • v.16 no.11
    • /
    • pp.313-327
    • /
    • 2018
  • In this era that technology is replacing human labor is coming. Like the introduction of Factory Automation and Smart Factory to enhance the productivity in manufacturing works in companies, RPA (Robotic Process Automation) is being applied to strengthen the competiveness in service & office work of companies. But, RPA itself is not mature enough to be the specific technology or solution, but burgeoning as the conceptual technology alternatives to automate the business process harnessed with the concept of software robots, artificial intelligence etc. The biggest difference that the introduction of RPA can make is the transition of the work based on 'human labor', to the 'digital labor' that could result in the replacement of human labor itself with that. Considering this kind of impact to change the concept of labor, the discussion for the future policy for this is inevitable. In this paper, beginning from the overview of RPA, relevant concerns & consideration for the application of RPA will be described based on the understanding of industrial & technology trends and expected future of RPA.

The Reorganization and Institutional Characteristics of National Records Management System during the 1980s to the 1990s (1980~90년대 국가기록관리체제의 개편과 제도적 특징)

  • Lee, Seung-Il
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.8 no.2
    • /
    • pp.5-38
    • /
    • 2008
  • Under the changes of administrative systems and office automation, 'the national record management system' had been reformed until 'Record Management Act' was enacted in 1999. Between 1984 and 1992, the national record management system was reformed in process of overcoming national crises and carrying out office automation. As a result, the system was absorbed into 'Governmental Document Regulations', 'Official Document Management Regulations' and 'Governmental Document Regulations'. In addition, 'government document classification scheme' and 'Record schedule' were unified into 'Official Document Classification and Record schedule'.

Characteristics of Lightning Overvoltages Coming in Low-Voltage Power Distribution Systems

  • Lee, Bok-Hee;Lee, Dong-Moon;Lee, Su-Bong;Jeong, Dong-Cheol;Lee, Jae-Bok;Myung, Sung-Ho
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.3
    • /
    • pp.91-98
    • /
    • 2003
  • The importance of improving the quality of electric power is being strongly raised, owing to an increasing use of sensitive and small-sized electronic devices and systems. The transient over-voltages on low-voltage power distribution systems are induced by direct or indirect lightning return strokes. These can cause damage and/or malfunction of the utility systems for home automation, office automation, factory automation, medical automation, etc. The behaviors of lightning overvoltages transferred through the transformer to the low-voltage distribution systems using a Marx generator were experimentally investigated. Furthermore, the coupling mechanisms of lightning overvoltages transferred to the low-voltage systems were clearly illustrated through a theoretical simulation using a Pspice program. The overvoltages in low-voltage ac power systems are rarely limited by the application of the surge arrester to the primary side of the distribution transformer. A superior surge protection scheme is to install surge protection devices at the service entrance switchboard and/or at the load devices in TN power systems.