• Title/Summary/Keyword: Off-pump

Search Result 300, Processing Time 0.027 seconds

Off Pump Total Arterial Myocardial Revascularization (동맥 도관만을 이용하여 체외심폐순환 없이 시행한 관상동맥우회술)

  • Youn Young Nam;Lee Kyo Joon;Lee Gy Jong;Joo Hyun Chul;Lim Sang Hyun;Kim Seung Ho;Kwak Young Lan;Yoo Kyung Jong
    • Journal of Chest Surgery
    • /
    • v.38 no.5 s.250
    • /
    • pp.349-356
    • /
    • 2005
  • Background: Arterial conduits using in coronary artery bypass grafting (CABG) have been known a great long term patency rates, and improved short and long term clinical outcomes. It has been reported that Off pump CABG has better clinical results than CABG using cardiopulmonary bypass. To evaluate the advantage of arterial conduits over venous conduits and to avoid the adverse effects of cardiopulmonary bypass, we performed total arterial Off pump CABG. Material and Method: From January 2001 to October 2004, Off pump CABG using only arterial conduits was performed on 325 patients with a mean age of $59.3\pm11.9$ years ($36\~83$). Mean ejection fraction was $55.4\pm14.0\%\;(15\~86).$ Angiography showed left main disease or triple-vessel disease in $81.9\%$ of the patients. Indications of using arterial conduits was stenosis $\ge50\%$ of left anterior descending artery, stenosis $\ge80\%$ of branches of left circumflex artery, and stenosis $\ge90\%$ of right coronary artery and its branches. Multi-slice computed tomography was performed on 194 patients to evaluate the short term patency rates. Result: A total of 928 distal anastomoses were performed and the average anastomoses per a patient were $2.86\pm0.78$. There was 1 operative mortality. Postoperative complications were mediastinitis in 6 patients ($1.8\%$), renal failure in 4 patients ($1.2\%$), perioperative myocardial infarction in 3 patients ($0.9\%$), reoperation for bleeding in 3 patients ($0.9\%$). There was no postoperative stroke. Patency rate of arterial conduits was $99.3\%$ (581/585). There were 4 stenoses or competitive flows in 2 radial arteries and 2 right internal mammary arteries. Conclusion: Total arterial Off pump CABG appears to be safe, showing a low surgical mortality and morbidity and excellent short term patency rates of arterial conduits.

Combined Bilateral Lung Transplantation and Off-Pump Coronary Artery Bypass

  • Do, Young Woo;Jung, Hee Suk;Lee, Chang Young;Lee, Jin Gu;Youn, Young-Nam;Paik, Hyo Chae
    • Journal of Chest Surgery
    • /
    • v.49 no.6
    • /
    • pp.461-464
    • /
    • 2016
  • Coronary artery disease has historically been a contraindication to lung transplantation. We report a successful combined bilateral lung transplantation and off-pump coronary artery bypass in a 62-year-old man. The patient had a progressive decline in lung function due to idiopathic pulmonary fibrosis and a history of severe occlusive coronary artery disease.

Mid-Term Outcomes and Angiographic Patency of Redo Coronary Artery Bypass Grafting: A Comparison between OffPump and On-Pump Surgery

  • Sohn, Suk Ho;Kim, Seung Hyun;Hwang, Ho Young;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.54 no.2
    • /
    • pp.106-116
    • /
    • 2021
  • Background: We evaluated the mid-term outcomes and angiographic patency of redo coronary artery bypass grafting (CABG). Methods: Of 2,851 patients who underwent isolated CABG at Seoul National University Hospital from 2000 to 2017, 88 underwent redo CABG. Patients' mean age at redo CABG was 66.0±8.0 years. The mean interval between the first-time and redo CABG was 113.0±62.4 months. The mean follow-up duration was 86 months. Early and mid-term clinical outcomes were evaluated. Angiographic patency rates were evaluated early (1-2 days), 1 year, and 5 years after surgery. Comparative analyses between on-pump and off-pump CABG were also performed. Results: The culprits for reoperation were previous grafts (65.6%), native coronary vessels (17.8%), and both (16.7%). Off-pump CABG was performed in 75 cases (85.2%), and the mean number of distal anastomoses was 1.8±0.8. The saphenous vein (39.7%) was used most frequently, followed by the right internal thoracic artery (28.4%), right gastroepiploic artery (21.3%), left internal thoracic artery (7.8%), and radial artery (2.8%). Operative mortality was 1.1%. The overall survival, cumulative incidence of cardiac death, and cumulative incidence of major adverse cardiac events were 71.3%,12.0%, and 23.3% at 5 years after surgery, respectively. The overall angiographic patency rates were 95.7%, 90.1%, and 92.2% on early, 1-year, and 5-year angiograms, respectively. The angiographic patency rates of saphenous vein grafts were 93.1%, 85.6%, and 91.3% on early, 1-year, and 5-year angiograms, respectively. No significant differences in clinical outcomes or angiographic patency rates were observed between the on-pump (n=13) versus off-pump (n=75) groups. Multivariable analysis revealed that age (hazard ratio [HR], 1.07; p=0.005) and chronic kidney disease (HR, 3.85; p=0.001) were risk factors for all-cause mortality. Conclusion: Redo CABG could mostly be performed using the off-pump technique and did not show increased operative mortality and morbidities.

The Comparison Study of Early and Midterm Clinical Outcome of Off-Pump versus On-Pump Coronary Artery Bypass Grafting in Patients with Severe Left Ventricular Dysfunction (LVEF${\le}35{\%}$) (심한 좌심실 부전을 갖는 환자에서 시행한 Off-Pump CABG와 On-Pump CABG의 중단기 성적비교)

  • Youn Young Nam;Lee Kyo Joon;Bae Mi Kyung;Shim Yeon Hee;Yoo Kyung-Jong
    • Journal of Chest Surgery
    • /
    • v.39 no.3 s.260
    • /
    • pp.184-193
    • /
    • 2006
  • Background: Off-pump coronary artery bypass grafting (OPCAB) has been proven to result in less morbidity. The patients who have left ventricular dysfunction may have benefits by avoiding the adverse effects of the cardiopulmonary bypass. The present study compared early and midterm outcomes of off-pump versus on-pump coronary artery bypass grafting (On pump CABG) in patients with severe left ventricular dysfunction. Material and Method: Ninety hundred forth six patients underwent isolated coronary artery bypass grafting by one surgeon between January 2001 and Febrary 2005.. Data were collected in 100 patients who had left ventricular ejection fraction (L VEF) less than $35\%$ (68 OPCAB; 32 On pump CABG). Mean age of patients were 62.9$\pm$9.0 years in OPCAS group and 63.8$\pm$8.0 years in On pump CABG group. We compared the preoperative risk factors and evaluated early and midterm outcomes. Result: In OPCAB and On pump CABG group, mean number of used grafts per patient were 2.75$\pm$0.72, 2.78$\pm$0.55 and mean number of distal anastomoses were 3.00$\pm$0.79, 3.16$\pm$0.72 respectively. There was one perioperative death in OPCAB group ($1.5\%$). The operation time, ventilation time, ICU stay time, CK-MB on the first postoperative day, and occurrence rate of complications were significantly low in OPCAB group. Mean follow-up time was 26.6$\pm$12.8 months (4${\~}$54 months). Mean LVEF of OPCAB and On pump CABG group improved significantly from $27.1\pm4.5\%$ to $40.7\pm13.0\%$ and $26.9\pm5.4\%$ to $33.3\pm13.7\%$. The 4-year actuarial survival rate of OPCAB and On pump CABG group were $92.2\%,\;88.3\%$ and the 4-year freedom rates from cardiac death were $97.7\%,\;96.4\%$ respectively. There were no significant differences between two groups in 4 year freedom rate from cardiac event and angina. Conclusion: OPCAS improves myocardial function and favors early and mid-term outcomes in patients with severe left ventricular dysfunction compared to On pump CABG group. Therefore, OPCAB is a preferable operative strategy even in patients with severe left ventricular dysfunction.

An Experimental Study on the Performance Characteristics of Hot-gas and Liquid Bypass Heat Pump Systems for Capacity Modulation (고온가스 및 액체 바이패스 적용 용량가변 히트펌프의 성능특성에 관한 실험적 연구)

  • Ahn, Jae Hwan;Joo, Youngju;Yoon, Won Jae;Kang, Hoon;Kim, Yongchan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.3
    • /
    • pp.137-142
    • /
    • 2013
  • A small air-conditioner or chiller for a constant temperature bath normally uses a constant speed compressor. The constant speed compressor is relatively inexpensive, but it uses on/off control for capacity modulation. The on/off control has several disadvantages, specifically energy loss and large temperature fluctuation. Continuous operation with a bypass system can be an alternative to on/off control, for capacity modulation. In this study, a heat pump system having a hot-gas bypass and a liquid bypass was adopted. The performance of the bypass-type heat pump was measured, by varying the bypass valve opening. The differences of the COP between the hot-gas bypass and the liquid bypass, in the cooling and heating operations, were within 2% and 1%, respectively. The liquid bypass showed a wider range of capacity control in the cooling operation but the hot-gas bypass showed a wider range of capacity control in the heating operation.

Prediction of Axial Pump Performance Using CFD Analysis (전산유체해석을 이용한 축류펌프의 성능예측)

  • Kim M. H.;Kim J. I.;Park J. S.
    • Journal of computational fluids engineering
    • /
    • v.6 no.1
    • /
    • pp.14-20
    • /
    • 2001
  • The CFD analysis of the three-dimensional turbulent flow in the impeller and diffuser of an axial flow pump was performed. Not only the design point but also the off-design points were computed. The results were compared with available experimental data in terms of head generated. At the design point, the analysis accurately predicted the experimental head value. In the range of the higher flow rates, the results were also in very good agreement with the experimental data, not only in absolute value but also in term of slope. Although experimental data to be compared were not available in the range of the lower flow rates, the results well described the S-shape performance curve of the axial pump characteristic.

  • PDF

Computational Performance Prediction of Main Coolant Pump for the Integral Reactor SMART (일체형원자로 SMART 냉각재 순환펌프의 전산성능예측)

  • Kim M. H;Lee J. S;Park J. S;Kim J. I;Kim K. K
    • Journal of computational fluids engineering
    • /
    • v.8 no.3
    • /
    • pp.32-40
    • /
    • 2003
  • CFD analyses of the three-dimensional turbulent flow in the impeller and diffuser of an axial flow pump including suction and discharge parts are presented and compared with experimental data. The purpose of the current study is to validate the CFD method for the performance analysis of the main coolant pump for SMART and to investigate the effect of suction and discharge shapes on the pump performance. To generate a performance curve, not only the design point but also the off-design points were computed. The results were compared with available experimental data in terms of head generated. At the design point, the analysis accurately predicts the experimental head value. In the range of the higher flow rates, the results are also in very good agreement with the experimental data, in magnitude but also in terms of slope of variation. For lower flow rates, the results shows that the analysis considering the suction and discharge well describe the typical S-shape performance curve of the axial pump.

Changes of Coagulability after Off-pump CABG: Comparison with On-pump CABG (심폐바이패스 없이 시행하는 관상동맥우회술 후 혈액응고 기늠의 변화: 심폐바이패스하 관상동맥우회술 후 혈액응고 상태와의 비교)

  • 장우익;김기봉;김욱성;정철현;허재학;장지민;이동순;한규섭
    • Journal of Chest Surgery
    • /
    • v.37 no.3
    • /
    • pp.245-251
    • /
    • 2004
  • Hemostatic function is regarded to be preserved after an off-pump coronary artery bypass grafting (CABG), compared to conventional CABG, and the preserved hemostatic function may increase thrombotic occlusion of the graft. We studied the changes of hemostatic variables in patients undergoing off-pump CABG, and compared to those of on-pump CABG. We studied the changes of coagulation function in 11 patients who underwent off-pump CABG (group I), and compared them with those of 11 patients who underwent on-pump CABG and Dor procedure (group II). Coagulation status was evaluated by thromboelastography and blood coagulation test preoperatively, postoperative 1$^{st}$ day, 2$^{nd}$ day, 3$^{rd}$ day, and 5$^{th}$ day, respectively. Among the variables measured by thromboelastography (such as r time, k time, $\alpha$ angle, and MA value) and blood coagulation test (such as factor Ⅶ, protein S, protein C, antithrombin III, activated protein C resistance test, plasminogen, D-dimer, prothrombin time, activated partial thromboplastin time, platelet count, hemoglobin, and fibrinogen), there were significant differences in the MA value, $\alpha$ angle, and platelet counts between the two groups. MA values were 140$\pm$72% and 153$\pm$98% in group I, and 87$\pm$27% and 78$\pm$28% in group II, at postoperative 3$^{rd}$ and 5$^{th}$ days, respectively (p<0.05). $\alpha$ angle was 122$\pm$92% in group I and 69$\pm$23% in group II at postoperative 3$^{rd}$ day (p=0.09). Platelet count was 63$\pm$55% in group I and 33$\pm$13% in group II at postoperative 3$^{rd}$ day (p<0.05). Patients who underwent off-pump CABG showed increased coagulability during postoperative periods, compared to those who underwent on-pump CABG. Our data suggest that aggressive perioperative anticoagulation therapy is warranted in patients undergoing off-pump CABG. CABG.

Oxidative Stress Is Decreased in Off-pump Versus On-pump Coronary Artery Surgery

  • Gonenc, Aymelek;Haclsevki, Aysun;Bakkaloglu, Beyhan;Soyaglr, Aylin;Torun, Meral;Karagoz, Haldun;Simsek, Bolkan
    • BMB Reports
    • /
    • v.39 no.4
    • /
    • pp.377-382
    • /
    • 2006
  • Oxidative stress occurs in patients undergoing coronary artery bypass operation. The aim of this study was to investigate the difference in oxidative stress in off-pump versus on-pump coronary artery bypass surgery. In the present study, in serial blood samples, plasma malondialdehyde (MDA) as index of lipid peroxidation, red blood cells glutathione peroxidase (GPx) and superoxide dismutase (SOD) were measured to compare the extent of oxidative stress in 30 patients undergoing OPCAB (off-pump coronary artery bypass grafting), 12 patients undergoing CABG (on-pump coronary artery bypass grafting) and 18 healthy controls. In CABG group, MDA levels increased significantly from $2.87{\pm}0.62\;nmol/mL$ before anesthesia and $2.87{\pm}0.65\;nmol/mL$ after anesthesia to $3.05{\pm}0.66\;nmol/mL$ after ischemia (p < 0.05). Similarly, SOD levels also elevated significantly from $661.58{\pm}78.70\;U/g$ Hb before anesthesia and $659.42{\pm}81.21\;U/g$ Hb anesthesia induction to $678.08{\pm}75.80\;U/g$ Hb after ischemia (p < 0.01, p < 0.01, respectively). In OPCAB group, only SOD levels increased from $581.73{\pm}86.24\;U/g$ Hb anesthesia induction to $590.90{\pm}88.90\;U/g$ Hb after reperfusion (p < 0.05). Glutathione peroxidase levels were not changed according to blood collection times in both of CABG group or OPCAB group (p > 0.05). Our results show that only mild signs of oxidative stress is found after reperfusion in OPCAB operation compared with CABG operation. Further studies are needed in order to confirm this hypothesis.

A Charge Pump with Matched Delay Paths for Reduced Timing Mismatch (타이밍 부정합 감소를 위해 정합된 지연경로를 갖는 전하 펌프)

  • Heo, Joo-Il;Heo, Jung;Jeong, Hang-Geun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.5
    • /
    • pp.37-42
    • /
    • 2012
  • In this paper, a new charge pump is proposed to reduce the timing mismatch in the conventional current-steering charge pumps. Conventional current-steering charge pumps used NMOS input stages both for UP and DOWN signals, which resulted in different numbers of stage for UP and DOWN delay paths. The proposed charge pump has equalized the numbers of stages for UP and DOWN signals by using a PMOS stage for the DOWN signal. The simulation results show that the conventional current-steering charge pump has 14ns and 6ns for optimized timing mismatches between UP and DOWN signals for turn-on and turn-off, respectively. On the other hand, the proposed charge pump has improved timing mismatches of 6ns and 5ns for turn-on and turn-off, respectively. As a result, the reference spurs are reduced from -26dBc to -39dBc for the proposed charge pump. The proposed charge pump was designed by using $0.18{\mu}m$ CMOS technology. The measurement results show that the maximum variation of the charging and discharging current over the charge pump output voltage range of 0.3~1.5V is approximately 1.5%.