• Title/Summary/Keyword: Off-cycle

Search Result 475, Processing Time 0.026 seconds

Run-off Impact Assessment of the Steeped Cornfield to Small Stream

  • Shin, Joung-Du;Lee, Jong-Sik;Kim, Won-Il;Jung, Goo-Bok;So, Kyu-Ho;Lee, Jung-Teak;Lee, Myong-Sun
    • Korean Journal of Environmental Agriculture
    • /
    • v.24 no.4
    • /
    • pp.334-340
    • /
    • 2005
  • This experiment was conducted to evaluate the nutrient loss and to assess the eutrophication into small stream by intensive rains in the steeped cornfield during cultivation. The crop cultivated was a soiling com (DW5969), and the experimental plots were divided into two parts that were 10 and 18% of slope degrees. The amount of T-N and T-P loss was calculated by analysis of surface run-off water quality, and was investigated the effect of eutrophication to small stream as a part of life cycle assessment (LCA) methodology application. For the surface run-off water quality, EC and T-N values were highest in first runoff event as compared to the other events and maintained the stage state with litter variations at every hour during the runoff period except for EC in the slope 18%. However, T-P concentration has been a transient stage after runoff event of July 27. Total surface run-off ratio was not significantly different with slope degrees, but amount of T-N and T-P losses at 18% of slope were high as $5.96kg\;ha^{-1}\;and\;0.65kg\;ha^{-1}$ as relative to 10% of slope degree, respectively. Furthermore, T-N losses from run-off water in the sloped cornfield 10 and 18% were approximately 9.8 and 12.5% of the N applied as fertilizer when the fertilizer applied at recommended rates after soil test, respectively. For the eutrophication impact to the small stream, it was shown that $PO_4$ equivalence and Eco-indicator value at 18% of slope degree were greater as much $6.11kg\;ha^{-1}$ and 0.81 as compared to the slope angle 10%, respectively. Therefore, it was appeared that each effect of nutrient losses, eutrophication and Eco-indicator value was enhanced according with higher slope degree.

Study on the Code System for the Off-Site Consequences Assessment of Severe Nuclear Accident (원전 중대사고 연계 소외결말해석 전산체계에 대한 고찰)

  • Kim, Sora;Min, Byung-Il;Park, Kihyun;Yang, Byung-Mo;Suh, Kyung-Suk
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.4
    • /
    • pp.423-434
    • /
    • 2016
  • The importance of severe nuclear accidents and probabilistic safety assessment (PSA) were brought to international attention with the occurrence of severe nuclear accidents caused by the extreme natural disaster at Fukushima Daiichi nuclear power plant in Japan. In Korea, studies on level 3 PSA had made little progress until recently. The code systems of level 3 PSA, MACCS2 (MELCORE Accident Consequence Code System 2, US), COSYMA (COde SYstem from MAria, EU) and OSCAAR (Off-Site Consequence Analysis code for Atmospheric Releases in reactor accidents, JAPAN), were reviewed in this study, and the disadvantages and limitations of MACCS2 were also analyzed. Experts from Korea and abroad pointed out that the limitations of MACCS2 include the following: MACCS2 cannot simulate multi-unit accidents/release from spent fuel pools, and its atmospheric dispersion is based on a simple Gaussian plume model. Some of these limitations have been improved in the updated versions of MACCS2. The absence of a marine and aquatic dispersion model and the limited simulating range of food-chain and economic models are also important aspects that need to be improved. This paper is expected to be utilized as basic research material for developing a Korean code system for assessing off-site consequences of severe nuclear accidents.

Influence of Precooling Cooling Air on the Performance of a Gas Turbine Combined Cycle (냉각공기의 예냉각이 가스터빈 복합발전 성능에 미치는 영향)

  • Kwon, Ik-Hwan;Kang, Do-Won;Kang, Soo-Young;Kim, Tong-Seop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.2
    • /
    • pp.171-179
    • /
    • 2012
  • Cooling of hot sections, especially the turbine nozzle and rotor blades, has a significant impact on gas turbine performance. In this study, the influence of precooling of the cooling air on the performance of gas turbines and their combined cycle plants was investigated. A state-of-the-art F-class gas turbine was selected, and its design performance was deliberately simulated using detailed component models including turbine blade cooling. Off-design analysis was used to simulate changes in the operating conditions and performance of the gas turbines due to precooling of the cooling air. Thermodynamic and aerodynamic models were used to simulate the performance of the cooled nozzle and rotor blade. In the combined cycle plant, the heat rejected from the cooling air was recovered at the bottoming steam cycle to optimize the overall plant performance. With a 200K decrease of all cooling air stream, an almost 1.78% power upgrade due to increase in main gas flow and a 0.70 percent point efficiency decrease due to the fuel flow increase to maintain design turbine inlet temperature were predicted.

Performance Test of a R134a Centrifugal Water Chiller

  • Jeong, Jin-Hee;Yoon, Pil-Hyun;Kim, Ghil-Yeung;Lee, Hyeon-Koo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.2
    • /
    • pp.97-105
    • /
    • 2002
  • A centrifugal water chiller using alternative refrigerant R134a has been developed. The prototype was designed to have refrigerating capacity of 300RT. Its compressor employs a single high-speed impeller, airfoil diffuser and collector. Newly developed, enhanced tubes were installed in the evaporator and the condenser to reduce the required head for the compressor. Off-design characteristics at various conditions, performance test of the compressor and analysis of the refrigeration cycle were performed. So the probability of use in part load condition was checked and the direction for revision was suggested.

Simnlation of a Thermal Behavior in Solar Heating and Cooling System with respect to Demand Room Temperature (실내 설정온도에 따른 태양열 냉난방 시스템의 동적 거동 해석)

  • Jang, H.Y.;Lee, S.B.;Chung, K.T.;Suh, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3446-3451
    • /
    • 2007
  • The thermal behavior of a building in response to heat input from an active solar space heating system is analysed to determine the effect of the variable storage tank temperature on the cycling rate, on and off temperature of a heating cycle and on the comfort characteristics of room air temperature. A computer simulation of the system behavior has been performed and verified by comparisons with various parameters. Especially, this study is focused on the effect of the system's performance when subjected to dynamic cooling loads. The heat input to the absorption system is provided by an array of solar collectors that coupled to a thermal storage tank.

  • PDF

Dynamic Model for Ocean Thermal Energy Conversion Plant with Working Fluid of Binary Mixtures

  • Nakamura, Masatoshi;Zhang, Yong;Bai, Ou;Ikegami, Yasuyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2304-2308
    • /
    • 2003
  • Ocean thermal energy conversion (OTEC) is an effective method of power generation, which has a small impact on the environment and can be utilized semi-permanently. This paper describes a dynamic model for a pilot OTEC plant built by the Institute of Ocean Energy, Saga University, Japan. This plant is based on Uehara cycle, in which binary mixtures of ammonia and water is used as the working fluid. Some simulation results attained by this model and the analysis of the results are presented. The developed computer simulation can be used to actual practice effectively, such as stable control in a steady operation, optimal determination of the plant specifications for a higher thermal efficiency and evaluation of the economic prospects and off-line training for the operators of OTEC plant.

  • PDF

A Study on Furniture Market of South Korea in New Normal - Focus on Economic Perspectives - (뉴 노멀시대 한국의 가구 시장 연구 - 경제적 관점을 중심으로 -)

  • Jung, Jaenah
    • Journal of the Korea Furniture Society
    • /
    • v.29 no.1
    • /
    • pp.8-17
    • /
    • 2018
  • Economic crisis in 2008 has changed South Korean market including furniture related field. Owing to Subprime Mortgage Crisis, new economic order, in other words, New Normal was established. Low growth rate, low interest, high unemployment rate, high risks, regulation strengthening, and all that sort of negative things have became generalized. South Korean economy has developed drastically since the Korean War, however recent economic crisis and Internet and smart phone have leading roles in shaping new consumption market. In a way, furniture market has expanded despite economic recession. Total service for housing is suited to South Korean consumers and shortened Product Life Cycle induces consumers to buy more furniture. In addition, Internet and smart phone allow people to show off their private spaces to unspecified masses. As a result, consumer prefers inexpensive and expendable furniture. It is certain that furniture market makes quantitative growth, but qualitative sides are questionable. Even though the study is focused on the existent circumstances, It will help to find out the proper ways of future furniture market in South Korea.

  • PDF

Thermodynamic Characteristics of an Aircraft Environmental Control System (항공기 환경제어 계통의 열역학적 특성)

  • 차재병;강병찬;오태식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.4
    • /
    • pp.1116-1124
    • /
    • 1995
  • Using a cycle simulation program developed by authors, some thermodynamic characteristics of an aircraft ECS under various operating conditions are studied. When the inlet temperature of cockpit and avionics bay, as well as ram air flow, is held fixed, the effect of the change of regulated bleed pressure is examined. When the regulated bleed pressure, and the cockpit and avionics bay inlet temperature are fixed, the effect of the change of ram air flow is also investigated.

Performance of fiber media filter device for combined sewer overflows treatment (합류식 하수관거 월류수 처리를 위한 섬유사 여과 장치의 처리특성)

  • Son, Sang-Mi;Warangkana, Jutidamrongphan;Park, Ki-Young;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.2
    • /
    • pp.231-236
    • /
    • 2010
  • A compressible media filtration process with synthetic fiber media was studied for combined sewer overflows (CSOs) treatment. Since the operation performance of fiber media filtration was dependent on the pattern of CSOs, the flow rate of CSOs was investigated and it was characterized by a big fluctuation. Thus, in this study, the fiber media filtration process was tested with wide range of filtration velocity. The removal efficiency was proportion to the increase in compressibility. As the filtration velocity was increased, the treatment efficiency was decreased and consequently leveled off when the velocity exceeded 750 $m^3/m^2$/d. An exponential equation was introduced to express the relationship between the removal efficiency and up-flow velocity. At columm test, six repetition of filtration and backwash cycle did not after the filtering velocity under the constant pressure condition.

A Study on Fuel Transport Characteristics in a Port Fuel Injected Sl Engine during Transient Condition (흡기포트 분사방식의 가솔린 엔진에서 급가속시 연료 거동에 관한 연구)

  • 황승환;조용석;이종화
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.3
    • /
    • pp.20-27
    • /
    • 2003
  • In this paper, the fuel transport characteristics during transient condition was studied by using a Fast Response Flame Ionization Detector(FRFID). The quantitative measurement method for the inducted fuel mass into cylinder is studied. The inducted fuel mass into the cylinder was estimated by using calculated air-fuel ratio by hydrocarbon concentration of cylinder and air flow model. In order to estimate the transportation of injected fuel from the intake port into cylinder, the wall wetting fuel model was used. The two coefficient $\alpha$,$\beta$) of the wall-wetting fuel model was determined from the measured fuel mass that was inducted into the cylinder at the first cycle after injection cut-off To reduce an air/fuel ratio fluctuation during rapid throttle opening, the appropriate fuel injection rate was obtain from the wall wetting model with empirical coefficients. Result of air/fuel ratio control, air/fuel excursion was reduced.