• Title/Summary/Keyword: Odor Removing Efficiency

Search Result 20, Processing Time 0.021 seconds

The Study on the Effect of Efficient Microorganism for Early Stabilization of the Burial Sites (매몰지 조기 안정화를 위한 유용 미생물의 효과에 관한 연구)

  • Kim, Hyun-Sook;Park, Sujung;Jheong, Weonhwa;Srinivasan, Sathiyaraj;Lee, Sang-Seob
    • Korean Journal of Microbiology
    • /
    • v.49 no.4
    • /
    • pp.343-352
    • /
    • 2013
  • In this study, we have evaluated the effect of efficient microorganisms on odor-removal efficiency and early stabilization of the burial sites. We have developed an efficient microorganism designated as 'KEM' which have the ability to degrade organic compounds and remove odor effectively. Other efficient microorganisms already used on site, such as EM and Bacillus sp., were also compared. We preceded these experiment using lab-scale reactors under three conditions (control, only media and only body) and comparing the effect of with or without the application of tree efficient microorganisms separately. Analysis was focused on eight components (ammonia, TMA, $H_2S$, methyl mercaptan, dimethyl sulfide, dimethyl disulfide, $CO_2$ and $CH_4$), and as a result, efficient microorganisms were shown efficiency in the removal of ammonia and methyl mercaptan. The applied KEM decayed up to 71.2% of the buried meat. We were unable to observe significant differences in microbial communities between efficient microorganisms-treated and non-treated reactors due to the large presence of microorganisms in both soil and carcasses. However, it was possible to observe the effect on odor control and decay rate through the application of efficient microorganisms.

Characteristics of Cyclone and Electric Dust Collection Oil Filters for Selective Removal of Fiber Tenter Air Pollutants (섬유 텐터 대기오염물질의 선택적 제거를 위한 싸이클론 및 전기 집진 오일필터의 특성)

  • Jin Ho Jung;Seung Hwan Ryu;Soon Duk Kwon;Yoon Hyun Cho
    • Textile Coloration and Finishing
    • /
    • v.35 no.4
    • /
    • pp.256-273
    • /
    • 2023
  • Among the dyeing industries, the tenter process is a process that improves the quality of fibers by drying and ironing (heat treatment) dyed fabrics, and drugs such as water repellents, antistatic agents, and fiber softeners are mainly used in these tenter processes. These drugs are vaporized in the process of treatment by high temperatures (180 ~ 230℃), and are observed in a complex form such as white smoke, oil mist, and fine dust, causing odor. To treat the complex exhaust gas at the rear end of the tenter facility, most companies operate by installing a wet scrubber and an adsorption tower alone or in parallel, but there are many problems. In particular, the insoluble oil mist at the rear end of the tenter has significantly low processing efficiency in the cleaning dust collection facility, and there is a problem in the facility by adsorption due to the occlusion phenomenon caused by the oil mist. In addition, the odor gas at the rear end of the tenter contains a lot of aldehydes, and in order to improve these various problems, a complex exhaust purification device using cyclone and electric support collector was developed. This study examined the applicability of economical and efficient technology by removing complex air pollution at the rear end of the tenter and applying improved technology than the existing technology.

The Removal of Algae by Pre-oxidation (전산화 공정을 이용한 조류제거)

  • Son, Hee-Jong;Jung, Chul-Woo;Bae, Sang-Dae;Choi, Young-Ik;Kang, Lim-Seok
    • Journal of Environmental Science International
    • /
    • v.18 no.3
    • /
    • pp.289-298
    • /
    • 2009
  • The blue-green algae which caused odor problem in the tap water are difficult to precipitate in sedimentation basin and clogged the filter void rapidly. The studies of this paper were not only oxidation, coagulation and sedimentation processes for effectively removing blue-green algae but yellow clay and polyamine for verification as coagulants aids. The results of this research are summarized as follows: Higher ozone dose(C) and longer contact time(T) were needed for a high degree of removing blue-green algae efficiency. the removal rate of blue-green algae was proportional to the $C\times T$ value. The removal percent of chlorophyll-a by sedimentation and filter without pre-ozonation was about 75% but 1 mg/L pre-ozonation could increase the removal percent of chlorophyll-a to 99% and more pre-ozonation could remove completely. Though the removal efficiency of turbidity could increased by high dose of chlorination, the dissolved organic carbon was increased. More chlorine dose from 4 to 10 mg/L dissolved organic carbon was decreased. Using yellow clay as coagulant aids increased density of floc so the settling velocity of floc become rising but polyamine could not increase settling velocity of floc though it could formated large floc.

Removal of microorganic pollutants based on reaction model of UV/chlorine process (자외선/염소 반응해석 모델에 의한 미량유기물질 제거에 관한 연구)

  • Hwang, Tae-Mun;Nam, Sookhyun;Kwon, Minhwan;Kang, Joon-Wun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.1
    • /
    • pp.73-81
    • /
    • 2017
  • The UV/chlorine process is a UV-based advanced oxidation process for removing various organic pollutants in water. The process is becoming increasingly popular because of its effectiveness in practice. It is important to the safe and efficient operation of a UV/chlorine process that the optimal operating conditions for both target removal objective and saving energy are determined. Treatment efficiency of target compounds in UV/chlorine process was mainly affected by pH and scavenging factor. In this study, kinetic based mathematical model considering water characteristics and electrical energy dose calculations model was developed to predict of treatment efficiency and optimal operating conditions. The model equation was validated for the UV/chlorine process at the laboratory scale and in pilot tests at water treatment plants.

Utilization of Natural Zeolite for Removal of $NH_3$ Gas (($NH_3$ 가스 제거를 위한 천연 지오라이트의 이용)

  • Lee, Dong-Hoon;Choi, Jyung;Park, Moung-Sub
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.4
    • /
    • pp.327-332
    • /
    • 1997
  • This study was conducted to find out the effect for removal of $NH_3$ gas, one of the offensive odor. The removal efficiencies of $NH_3$ gas through zeolie column increased with the decreased percolation velocity. The effect of zeolite colum in removing $NH_3$ gas was influenced by the water content of zeolite and the added amount of zeolite, but was not influenced by the setting method of zeolite. The $NH_3$ gas removing sequence of saturated cation species on zeolite was in order of Ca->Na->$NH_4$ ->Natural->K-zeolite. Consequently the effect of zeolite on $NH_3$ gas removal efficiency is consided by the water content, added amount and saturated cation of the zeolite.

  • PDF

The Effect of Soil Characters on Removal of Odorous Gases during Carcasses Degradation with Efficient Microorganisms (토질 특성에 따른 가축사체 매몰지의 악취 저감 연구)

  • Kim, Hyun-Sook;Park, Sujung;Jung, Weon Hwa;Srinivasan, Sathiyaraj;Lee, Sang-Seob
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.4
    • /
    • pp.277-285
    • /
    • 2014
  • The usage of efficient microorganism (EM) is increasing in concern for server purposes including odor removal during carcasses degradation. In this study, we have studied the type of soil and its effect on efficient microorganisms for the removal of odorous gases during buried carcasses degradation in lab-scale reactor. The carcasses are buried in the reactor with various soil types such as normal soil, 20% sandy and 20% clay soil with the efficient microorganism KEM. The efficient microorganisms KEM have the ability to stabilize the degradation of carcasses of the burial site. We have focused on the analysis of odorous gases such tri-methylamine (TMA), hydrogen sulfide ($H_2S$), methyl mercaptan (MM), dimethyl sulfide (DMS), dimethyl disulfide (DMDS), carbon dioxide ($CO_2$), and methane ($CH_4$) along with the changes of microbial community changed during complete degradation of buried carcasses for a year. The results suggested that the 20% sandy soil contain lesser level of $H_2S$ and MM (0.09 and 0.35 mg) but 20% clay has higher nitrogen compound removing effect and leave only less amount of ammonia and TMA (0.31 and 2.06 mg). The 20% sandy soil also has the ability to breakdown the carcasses more quality compared with other types of soil. Based on the data obtained in this study suggesting that, the use of 20% sandy soil can effectively control sulfur compounds whereas 20% clay soil controls nitrogen compounds in the buried soil. Depending on the type of the soil, the dominant of microbial communities and the distribution was change.

Reduction of Sulfur Compounds Produced from Swine Manure, Using Brevundimonas diminuta (Brevundimonas diminuta를 이용한 돈분뇨에서 발생되는 황화합물의 저감)

  • Oh, Min-Hwan;Lee, Eun-Young
    • Microbiology and Biotechnology Letters
    • /
    • v.45 no.3
    • /
    • pp.257-264
    • /
    • 2017
  • Mixed substrate oil cakes are known to emit sulfides, ammonia, and amines. Microorganisms capable of removing odorous gases related to these sulfur compounds were isolated from colonies enriched in vials containing oil cakes and water. Activity tests for hydrogen sulfide and methyl mercaptan reduction were performed to measure the sulfide reduction ratio of the isolates. Control groups were prepared with 0.25 g oil cakes and 10 ml water in a 100-ml vial without inoculation. The experimental groups were prepared similarly, albeit with an inoculum. Hydrogen sulfide removal efficiency of >90% was observed for an isolate, which was identified as Brevundimonas diminuta by 16S rDNA sequence analysis. The sequence was deposited in the Korean Collection for Type Cultures under the accession number KCTC11724BP. B. diminuta could remove up to 200 ppmv standard hydrogen sulfide in 24 hours and demonstrated a maximum hydrogen sulfide and methyl mercaptan removal efficiency of 100% at 453 ppmv and 98 ppmv, respectively, in vial tests. Furthermore, B. diminuta cells in 20% (v/w) medium showed removal efficiency of >85% for sulfur compounds in an odor emission chamber for swine manure.

Investigation of geosmin removal efficiency by microorganism isolated from biological activated carbon (생물활성탄에서 분리한 미생물의 지오스민 제거효율 평가)

  • Baek, Dawoon;Lim, Jaewon;Cho, Yoonjung;Ahn, Yong-Tae;Lee, Hyeyoung;Park, Donghee;Jung, Dongju;Kim, Tae-Ue
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.1
    • /
    • pp.47-55
    • /
    • 2015
  • Recently, the production of taste and odor (T&O) compounds is a common problem in water industry. Geosmin is one of the T&O components in drinking water. However, geosmin is hardly eliminated through the conventional water treatment systems. Among various advanced processes capable of removing geosmin, adsorption process using granular activated carbon (GAC) is the most commonly used process. As time passes, however GAC process changes into biological activated carbon (BAC) process. There is little information on the BAC process in the literature. In this study, we isolated and identified microorganisms existing within various BAC processes. The microbial concentrations of BAC processes examined were $3.5{\times}10^5$ colony forming units (CFU/g), $2.2{\times}10^6CFU/g$ and $7.0{\times}10^5CFU/g$ in the Seongnam plant, Goyang plant and Goryeong pilot plant, respectively. The dominant bacterial species were found to be Bradyrhizobium japonicum, Novosphingobium rosa and Afipia broomeae in each plants. Removal efficiencies of $3{\mu}g/L$ geosmin by the dominant species were 36.1%, 36.5% and 34.3% in mineral salts medium(MSM) where geosmin was a sole carbon source.

Olfactory Sensitivity Characteristics of Odors from Injection Molding Processing (사출성형 공정에서 유발되는 냄새의 후각 감성 특성)

  • Ryu, Young-Jae;Kim, Bo-Seong;Lee, Ye-Hyun;Kwak, Seung-Hyun;Seo, Sang-Hyeok;Ryu, Tae-Beum;Min, Byung-Chan
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.4
    • /
    • pp.67-71
    • /
    • 2016
  • The purpose of this study was to explore olfactory sensitivity of odors from injection molding processing. To do this, the experiment was carried out in an injection molding factory, and participants were exposed to the environment where odor-substances (Formaldehyde, Benzene, Toluene, Ethylbenzene, Xylene, Styrene) exist. In addition, we used the subjective scale using semantic adjectives as an olfactory sensitivity. As a result, the assessment structure of olfactory sensitivity was composed of eight factors (irritant, thermal, tense, unique, like-dislike, active, stable, masculine), and the main factor which was irritant characteristics explained 20% of the total olfactory sensibility. These results suggested that odors from injection molding processing would cause more negative emotional responses than the flavor which is mainly used in olfactory sensitivity. This study, as a basic study of the improvement in a factory environment for the efficiency of work, has limits in that it was conducted to the extent of identifying the olfactory sensitivity structure of those who were at a laboratory and who were exposed to the environment of odor substance induced in the injection molding processing. Therefore, for the method of removing malodorous substance, the effect of materials which can neutralize it, and the comparison of a direct performance in the environment where negative sensitivity structure exists, a series of studies which aim to improve the environment of injection molding factories, such as performance assessment in the environment of a factory and an office need to be conducted. It is expected that when these studies are put together, the improvement guidelines will be provided as a type that can maximize the effectiveness of work in the factory environment where injection molding processing is done.

Study of Formation Factor of Biofilm on Aluminum surface and Removal Efficiency of Biofilm by Antimicrobials (알루미늄 표면에 생물막의 형성인자 및 항균제에 의한 생물막 제거효과 분석)

  • Park, SangJun;Oh, YoungHwan;Jo, BoYeon;Lee, JaeShin;Lee, SangWha;Jeong, JaeHyun
    • Korean Chemical Engineering Research
    • /
    • v.53 no.6
    • /
    • pp.730-739
    • /
    • 2015
  • 108 microorganism types (79 types of fungi and 29 types of bacteria) were isolated from 25 automobiles generating bad odor when the air conditioner was turned on, and 43 types of fungi and 23 types of bacteria were identified. The analysis of condensate generated by the air conditioners in the automobiles indicated pH 6.4~7.1, 12.5~34.2 mg/L carbon source, 0.9~18.6 mg/L nitrogen source, 0.5~27.8 mg/L ion contents, and 0.1~7.7 mg/L mineral contents. The biofilms were formed by the mesophiles under the summer temperature/humidity condition ($26^{\circ}C$, 70% R.H.), and they were regenerated when the environmental factors (nutritional contents and temperature/humidity) were appropriate even after they were artificially removed. Although the antimicrobials removed 99.9% of planktonic cells within 15 minutes, they were not effective in removing biofilm. Up to 1,950 ppmv of ethanol was observed in the automobile treated with the antimicrobials. Although the figure is lower than the acute toxicity level when inhaled by humans, the health safety of the chemical substances used in the antimicrobials needs to be reviewed.