• Title/Summary/Keyword: Ocular lens

Search Result 99, Processing Time 0.022 seconds

Comparison of Tear Distributions by the Corneal Eccentricity when Fitted with Spherical and Aspherical RGP Lenses (구면 및 비구면 RGP렌즈 피팅 시 각막 이심률별 눈물분포 비교)

  • Kim, Jihye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.2
    • /
    • pp.99-108
    • /
    • 2016
  • Purpose: The present study was aimed to compare the tear volume and distribution by corneal eccentricity when fitted with spherical and aspherical RGP lenses. Methods: Spherical and aspherical RGP lenses were fitted in best alignment on a total of 77 subjects (136 eyes) in their twenties and thirties without any ocular disease or ocular surgery experience. The tear volume was analyzed by estimating the concentration of tear stained with fluorescein in the center of RGP lens as well as at the mid-peripheral and peripheral areas, and the difference of tear distributions was analyzed according to corneal eccentricity. Results: Tear distribution from the center to the peripheral area was not significantly different when spherical RGP lenses were fitted on the corneal eccentricities of e < 0.38 and $0.68{\leq}e$, indicating the relatively even tear distribution compared with other corneal eccentricity. In the case of aspherical RGP lenses, the difference of tear distribution between the central and peripheral areas was smaller than spherical RGP lenses. The significant difference of tear distribution according to RGP lens design was observed in the corneal eccentricity of 0.48 < e < 0.68. In other words, more even tear distribution was shown when aspherical RGP lenses were fitted on the cornea with eccentricity of $0.48{\leq}e<0.68$ and spherical RGP lenses were fitted on the cornea with eccentricity $0.68{\leq}e$. Furthermore, tear volume in the mid-peripheral area increased with higher corneal eccentricity. Conclusions: The results suggest that the appropriate selection of RGP lens design according to corneal eccentricity is necessary since tear volume and distribution by the regions of spherical and aspherical lenses are affected by corneal eccentricity.

The Correlation of Refractive Error and Ocular Dimensions in Older Age (고령의 연령에서 굴절이상과 안광학 성분들의 연관성 분석)

  • Lim, Byung Kwan;Jeon, Soon-Woo;Jeong, Youn Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.293-297
    • /
    • 2011
  • Purpose: This study was to know the correlation among refractive error and the dimensions of ocular components on older adults. Methods: The subjects were 95 older age who had no eye diseases. The refractive error, corneal radius, corneal diopter, axial length, anterior chamber depth and lens thickness were measured and analysed. Results: The axial length(AL)/corneal radius(CR) ratio was positively correlated with the corneal diopter, axial length, the anterior chamber depth. Then it was negatively correlated with corneal radius. It was shown that the highest correlation was between the corneal diopter and axial length (r = -0.545, p = 0.000). The spherical equivalent of the refractive error was negatively correlated with the AL/CR ratio. Conclusions: It was shown that the AL/CR ratio was a very important indicator for diagnosing the refractive error of the old age.

A study of Conjunctival Cellular Changes in Dry Eye Patients by Impression Cytology (Impression cytology를 이용한 건성안의 결막 세포변화에 관한 연구)

  • Kim, Jai-Min;Kho, Eun-Gyung;Chae, Soo-Chul;Kim, Soon-Ae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.333-343
    • /
    • 2004
  • Impression cytology refers to application of cellulose acetate filter material to the ocular surface to remove the superficial layers of the conjunctival epithelium. The technique is non-invasive, is easy to perform, causes minimal discomfort to the patient, and can be used to follow changes in the conjunctival ocular surface over time. With this method, the morphology of the conjunctival ocular surface can be studied and the degree of squmaous metaplasia assessed. This study was performed to evaluate the conjunctival surface by impression cytology in dry eye patients. A total of 70 students with no contact lens wearing history were recruited. Subjects were required to fill in a McMonnies dry eye symptom questionnaire. The non-invasive tear thinning time(TIT) test of each subject was measured, followed by Schirmer tear test(STI), tear film break-up time(TBUT) tests and Rose-bengal staining were performed as a baseline. Conjunctival epithelial cells from the inferior bulbar conjunctiva were harvested by the impression cytology technique. The specimens collected were labelled and stained with PAS(Periodic Acid Schift)-haematoxylin. The goblet cells and conjunctival epithelial cells were observed under a light microscope of 400x magnification. The specimens were classified according to the Nelson Grading scale which was based on the degree of squamous metaplasia such as changes of goblet cells density, size/form, N:C(nucleus : cytoplasm) ratio. Dry eye patients were observed morphological changes of the epithelial cells, different nuclear alterations, decrease of the goblet cells density. The degree of cytological changes was related to severity of dry eye conditions. When the epithelial cell morphology was graded according to the system described by Nelson, specimens from the control group revealed 91.43% of the eyes to be grade 0 and 8.57% to be grade 1, whereas of the dry eye patients, 20% were grade 0, 42.86% grade 1, 34.29% grade 2 and 2,86% grade 3. Impression cytology represents a non- or minimally invasive biopsy of the ocular surface epithelium with no side effects or contraindications. It has demonstrated to be a useful diagnostic aid for a wide variety of processes involving the ocular surface. This technique is a safe, simple method and may help increase understanding of various ocular surface alterations in dry eye patients.

  • PDF

Thermographic Assessment in Dry Eye Syndrome, Compared with Normal Eyes by Using Thermography (열화상카메라를 이용한 정상안과 건성안의 서모그래피 비교)

  • Park, Chang Won;Lee, Ok Jin;Lee, Seung Won
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.247-253
    • /
    • 2015
  • Purpose: The purpose of this study was to compare and analyze the ocular surface and the palpebral conjunctiva of categorized subjects, which were divided into normal eye group and dry eye group, by using a thermal camera. Methods: Subjects were 144 eyes of 72 normal university students, who didn't have any corneal disease, abnormal lacrimal ducts, medical records regarding ocular surgeries, or experience of using contact lens. Subjects were divided into two groups, which were normal eye group and dry eye group, based on the results of TBUT, Schirmer I test, and McMonnies test. After categorizing the subjects, the temperature of the subjects' ocular surface and the palpebral conjunctiva were measured and analyzed by using a thermal camera (Cox CX series, Answer co., Korea). Results: In the normal eye group's Central Ar.1, Nasal Ar.2, Temporal Ar.3, Superior Ar.4, Inferior Ar.5, the measured amount of temperature change on each area was $-0.13{\pm}0.08$, $-0.14{\pm}0.08$, $-0.12{\pm}0.08$, $-0.14{\pm}0.08$, $-0.10{\pm}0.09(^{\circ}C/sec)$. The dry eye group's results were $-0.17{\pm}0.08$, $-0.16{\pm}0.07$, $-0.16{\pm}0.08$, $-0.17{\pm}0.09$, $-0.15{\pm}0.08(^{\circ}C/sec)$. When compared with the normal eye group, the values of Ar.1, Ar.3, Ar.5 were significantly different in the dry eye group(p<0.05). The amount of temperature change, which was observed on the palpebral conjunctiva(Ar.1:central, Ar.2: nasal, Ar.3: temporal) of the normal eyes, measured by thermography, was $34.36{\pm}1.12$, $34.17{\pm}1.10$, $34.07{\pm}1.12^{\circ}C$ on each area. Same values taken from the dry eye group was $33.55{\pm}0.94$, $33.43{\pm}0.97$, $33.51{\pm}1.06^{\circ}C$ on each area. The values of Ar.1, taken from the dry eye group, had a significant difference, compared to the values of the normal eye group(p=0.05). Conclusion: The temperature of the ocular surface decreased faster on the dry eyes, compared to the normal eyes. The temperature measured on the palpebral conjunctiva of the dry eyes were also lower than the normal eyes. The temperature changes on the ocular surface, observed with a thermal camera, were objective values to assess the stability of tear films, and might provide useful data for studies related to dry eye syndrome.

Changes of multi-purpose solutions for soft contact lens depending on using period or keeping temperature (사용기간 및 온도에 따른 소프트콘택트렌즈 다목적용액의 변화)

  • Park, Mi-Jung;Ha, Ju-Ryung;Lee, Young-Min;Han, Hyeun-Woo;Kim, Seung-Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.381-389
    • /
    • 2004
  • To investigate changes of multi-purpose solutions for soft contact lens(MPS) depending on using period or keeping temperature, we evaluate four brands of MPS. No significant difference was seen in protein deposit removing efficacy after samples had used for 24 weeks and kept at $4^{\circ}C$, $20^{\circ}C$ or $30^{\circ}C$. The pH values of the samples of 4 brands measured weekly over the 24 week testing period. The initial average pH value of samples were 7.0, 7.5, 7.6 or 8.2. One brand of MPS was in the range of the threshold for ocular awareness, which is outside the zone of 6.6 ~ 7.8. During the testing period, the pH value were decreased in using period-dependent manner. At the 24th week, the average pH values of samples turned to 6.6, 7.2, 7.2 or 7.7. However, the difference of keeping temperature was not associated with decreased levels of pH values. After 24 weeks, one of total 36 samples was contaminated by bacteria. Furthermore, the change of components was shown after 24 weeks in the analysis using thin layer chromatography and the analysis of UV absorption pattern. The results of our study provides that the keeping temperature of MPS is not the important factor of changes of MPS, but the using period of MPS can cause contact lens wearers discomfort.

  • PDF

Effect of the Polaroid Lens in Binocular Vision (양안시에서 편광렌즈의 영향)

  • Kim, Douk-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.135-151
    • /
    • 2003
  • This study compared the effect of Polaroid$^{(R)}$ lenses on binocular vision by assessing visual acuity, stereopsis, and visual evoked potential(VEP), through Polaroid$^{(R)}$, CR 39 and sunglass lenses. The spectral absorptions of Polaroid$^{(R)}$, CR 39 and sunglass lenses were measured using a spectrophotometer (Hitachi. U-3501). The VEP were recorded by the Nicolet system. Thirty normal adult(fifteen males, fifteen females, mean=21.9 years, range=20 to 25) subjects were recorded. The subjects were provided a history including : general health, family health, medication, genetics, allergy and disease. All had normal or corrected to normal acuity with no history of visual disorders. Corrected visual acuity, colour vision and stereopsis were recorded for each subject monocularly and binocularly. Each test was repealed through the sunglass, CR 39, and Polaroid$^{(R)}$ lenses. Subjects viewed the VEP stimulus both monocularly and binocularly through the test lenses while the VEPs were recorded. The results suggest that the binocular visual acuity and stereoacuity is better than with monocular vision. On other hand, the analysis of VEP suggests that the amplitude of wave is smaller when the monocular eye receives the VEP stimulus compared with that when the binocular eye is stimulated by the VEP target with the sunglass, CR 39, and Polaroid$^{(R)}$ lens. But, the latency period of each eye was similar to results between the dominant eye and the non-dominant eye by the CR 39, sunglass, and polaroid lens. In conclusion, this study indicates that the binocular vision appears to be better through the brown Polaroid$^{(R)}$ lens than through the other test lenses.

  • PDF

The Effect of Extracapsular Cataract Extraction and Posterior Chamber Lens Implantation on Intraocular Pressure (백내장적출술 및 인공수정체삽입술이 안압에 미치는 영향)

  • Cha, Soon-Cheol;Lee, Kyoo-Won
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.2
    • /
    • pp.277-283
    • /
    • 1994
  • We studied the change in intraocular pressure (IOP) in 15 consecutive cataract patients who underwent extracapsular cataract extraction and posterior chamber lens implantation between Feb. 1993 and Apr. 1993 to evaluate the effect of this surgery on postoperative IOP. To evaluate the clinical usefulness of non-contact tonometer, the intraocular pressures were measured with Kowa non-contact tonometer (TM-2000, Japan) as well as Goldmann applanation tonometer. There was a decrease in IOP of $3.4{\pm}2.9$mmHg (p<0.00l) 3 months after this surgery and the intraocular pressure differences between pseudophakic eyes and contralateral phakic eyes at 3 months postoperatively were $2.4{\pm}3.8$mmHg (p<0.05). The correlation coefficient between non-contact tonometer and Goldmann tonometer was 0.8876 (p=0.001) in the postoperative 76 eyes. Therefore, our results suggest that extracapsular cataract extracion and posterior chamber lens implantation alone can be a useful surgical method in cataract patient with ocular hypertension, and non-contact tonometer was relatively accurate in measuring the postoperative intraocular pressure.

  • PDF

Optimization of optical focus of composition optical system by OSLO (합성광학계의 OSLO를 통한 optical focus의 최적화)

  • Kim, Dae Nyoun;Choi, Gei Hun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.1-6
    • /
    • 2000
  • This study was to calculate spot size, focus shift and optical focus by use of OSLO when 3 wavelength, ${\omega}{\upsilon}_1=0.588{\mu}$, ${\omega}{\upsilon}_2=0.486{\mu}$ and ${\omega}{\upsilon}_3=0.656{\mu}$ in composite lens optics system & ocular optical system were respectively here, Entrance Beam Radius(mm) 1 mm, Field angle(deg) 5.7296e-0.5 mm, Image Aperture 0.053055 mm, Exit Aperture 0.903711 mm, Reflective focal length 25.181544 mm, Petzval radius -19.21839 mm, n = 1.523. It was found that a range of spot size was 0.002 mm~0.07 mm when a range of back curvature radius was 1 mm~30 mm, and 0.0005 mm~0.002 mm when of it more than 50 mm. Focus shift, 50 mm a range 3 kinds of lens was small, and it saw that of all tendency was high up to 1 mm~15 mm and up to 25 mm beyond that limits, it was going down and then going up again, optical focus 100 mm lens was best and the value when optimization with this lens was $60{\pm}1mm$.

  • PDF

The Reflection Color Light with the Structure of an Antireflection Lenses (렌즈 무반사막 구조에 의한 반사색광의 특성 연구)

  • Kim, Yong-Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.1
    • /
    • pp.93-102
    • /
    • 1996
  • The optical system of lens must be designed to tramsmit light over wide wavelength range and to have lower reflectivity in order to obtain higher spectral transmittance. However, the reflection color light appears due to the remain-reflection light in any optical system of lens. The wavelength of the reflection color light can be controlled by the structure of the number of layers, thickness of layer, reflective index, wavelength of incidence, and substrate etc. In the optical systems of the single layer and the double layers, the reflection color light appears in the condition of the anti-reflection of ${\lambda}s/{\lambda}$ = 1.0 by the color mixture of the remain-reflection lights in the ranges of the longer wavelength side and the shorter one of the ${\lambda}s/{\lambda}$ = 1.0, and of the double layers and triple layers, the reflection color light positioned at P1 < ${\lambda}s/{\lambda}$ < P2 appears in the condition of the antireflection of ${\lambda}s/{\lambda}$ = $PI{\ll}1$ and $P2{\gg}1$. In the optical system of the multi-layers, many antireflection points are existed at the various s/ values, and the reflection color light by the color mixture of the remain-reflection lights in the ranges except for the antireflection points.

  • PDF

Study of the Axial Length/Corneal Radius Ratio in Determining the Refractive State of the Eye (굴절이상과 안축장/각막곡률반경 비와의 관계에 관한 연구)

  • Seo, Y.W.;Choe, Y.J.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.23-31
    • /
    • 1999
  • The purpose of this study is to evaluate the relationship between axial length/corneal radius ratio and refractive error for human eye. Ocular components were measured Baush & Lomb keratometer, Holden-Payor pachometer, and Stoz Compuscan. Refractive error was measured by subjective refraction. The results were as follows; 1) Spherical equivalent refractive error and axial length/corneal radius ratio was very highly correlated with the correlation coefficient for -0.89. 2) Axial length/corneal radius ratio and axial length, vitreous chamber depth were highly correlated that the correlation coefficients were 0.82, 0.80 respectively. 3) Axial length/corneal radius ratio and anterior chamber depth, corneal power, corneal radius, lens power were correlated with the correlation coefficients for 0.57, 0.40, -0.39, -0.35 respectively. 4) There were no significant correlation between axial length/corneal radius ratio and lens thickness, and corneal thickness.

  • PDF