• Title/Summary/Keyword: Ocular components

Search Result 15, Processing Time 0.226 seconds

Study of Ocular Components in Determining the Refractive State of the Eye (굴절이상을 결정하는 안광학 요소에 관한 연구)

  • Seo, Y.W.;Choe, Y.J.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.1
    • /
    • pp.7-14
    • /
    • 1999
  • The purpose of this study is to evaluate the relationship between ocular components and refractive error for human eye. Ocular components were measured by keratometry, phakometry, and ultrasonography. Refractive error was measured by subjective refraction on 38 subjects aged from 17 to 30. The results were as follows; 1) Refractive error and axial length, vitreous chamber depth, axial length/corneal radius were highly correlated that the correlation coefficients were 0.95, 0.96, 0.95, respectively. 2) Refractive error and corneal radius, corneal power, lens thickness were correlated with the correlation coefficients for 0.60, 0.66, 0.67 respectively. 3) There were no significant correlation between refractive error and corneal thickness.

  • PDF

Analysis on Ocular Components Variation with the Difference of Both Refractive Errors (양안 굴절이상 차이에 의한 안광학상수 변화도 분석)

  • Lee, Hae-Jung;Lee, Eun-Hee;Jung, Mi-A
    • Journal of Digital Convergence
    • /
    • v.14 no.11
    • /
    • pp.435-440
    • /
    • 2016
  • The aim of study was to provide the preliminary data to find out characteristics of the difference between both refractive errors through analysis of ocular components variation. We measured spherical equivalent power and corneal radius with KR-8800, and axial length and anterior chamber depth with IOL Master, and the difference of measuring values between the right eye and left eye was applied as the absolute values in 100 adults aged 20~59 years. In all participants, the most common results showed that spherical equivalent power was $-1.83{\pm}2.17D$, axial length was 23.00~24.99mm, corneal radius was 7.50~7.89mm, and anterior chamber depth was 3.60~4.09mm. There are significant correlations between both eyes in axial length and anterior chamber depth with the difference of both spherical equivalent power. The difference of both axial lengths was the biggest with the difference of both refractive errors, and shown the highest correlation. The convergence complex study through classification by aspects is needed since the difference of both refractive errors is closely related with ocular components variation, and poor visual function would be caused by the difference of both refractive errors.

The Correlation of Myopic Refractive Error and Ocular Components in Primary School Students (초등학생의 근시성 굴절이상과 안광학 성분들의 관련성)

  • Jeon, Soon-Woo;Lee, Hyun-Joo;Hwang, Hye-Kyung;Park, Chun-Man
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.299-303
    • /
    • 2012
  • Purpose: In this study the correlation among the myopic refractive error and ocular components in primary school students was investigated. Methods: The subjects were 62 children who had no eye diseases. The refractive error, corneal radius, anterior chamber depth, lens thickness, axial length were measured and analysed. Results: Myopic refractive error in primary school students was negatively correlated with the axial length (1~3rd grade r=-0.653, p=0.000/4~6th grade r=-0.742, p=0.000), AL/CR ratio (1~3rd grade r=-0.571, p=0.000/4~6th grade r=-0.852, p=0.000). Conclusions: It was shown that the axial length and axial length(AL)/corneal radius(CR) ratio were very important data for myopic refractive error in primary school students.

Examination of $\alpha$-terpinene on Primary Eye Irritancy and Skin Sensitization

  • Park, Byeoung-Soo;Choi, Won-Sik;Lee, Sung-Eun
    • Molecular & Cellular Toxicology
    • /
    • v.3 no.1
    • /
    • pp.68-75
    • /
    • 2007
  • [ $\alpha$ ]-Terpinene has been known as a repellent against the mosquito Culex pipiens pallens Coquillett based on a human forearm bioassay. $\alpha$-Terpinene showed significantly greater repellency than a commercial formulation, N, N-diethyl-m-methylbenzamide (deet). In this study, skin and eye sensitivity of $\alpha$-terpinene (2%) was examined with bioassays using white New Zealand rabbits. There were somewhat gross and histological changes observed in these treatments. Eye irritancy assays examined gross changes to cornea, iris and conjuctiva, and histological changes to smear of ocular discharge and eye tissue. Treated rabbits were divided into two cohorts, a saline washed cohort (W) or a non-washed cohort (NW). Opacity of cornea and redness, chemosis and discharge of conjuctiva were observed in both cohorts, but disappeared within 4 and 10 days in W and NW, respectively. Main components of ocular discharges were fibrin, epithelial or epitheloid cells, lymphoid cells, erythrocytes and granulocytes. These abnormal cellular components disappeared within 4 days and 10 days in W and NW, respectively. No permanent histological differences were observed between the two cohorts. However, severe irritation was determined as 57.2 of I.I.O.I value on the first day after treatment. These findings indicate a spray-type solution containing 2% $\alpha$-terpinene may serve as an alternative mosquito repellent and further studies need to reduce the eye irritation with formulation changes.

Design of Computer Access Devices for Severly Motor-disability Using Bio-potentials (생체전위를 이용한 중증 운동장애자들을 위한 컴퓨터 접근제어장치 설계)

  • Jung, Sung-Jae;Kim, Myung-Dong;Park, Chan-Won;Kim, Il-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.11
    • /
    • pp.502-510
    • /
    • 2006
  • In this paper, we describe implementation of a computer access device for the severly motor-disability. Many people with severe motor disabilities need an augmentative communication technology. Those who are totally paralyzed, or 'locked-in' cannot use conventional augmentative technologies, all of which require some measure of muscle control. The forehead is often the last site to suffer degradation in cases of severe disability and degenerative disease. For example, In ALS(Amyotrophic Lateral Sclerosis) and MD(Muscular dystrophy) the ocular motorneurons and ocular muscles are usually spared permitting at least gross eye movements, but not precise eye pointing. We use brain and body forehead bio-potentials in a novel way to generate multiple signals for computer control inputs. A bio-amplifier within this device separates the forehead signal into three frequency channels. The lowest channel is responsive to bio-potentials resulting from an eye motion, and second channel is the band pass derived between 0.5 and 45Hz, falling within the accepted Electroencephalographic(EEG) range. A digital processing station subdivides this region into eleven components frequency bands using FFT algorithm. The third channel is defined as an Electromyographic(EMG) signal. It responds to contractions of facial muscles and is well suited to discrete on/off switch closures, keyboard commands. These signals are transmitted to a PC that analyzes in a time series and a frequency region and discriminates user's intentions. That software graphically displays user's bio-potential signals in the real time, therefore user can see their own bio-potentials and control their physiological signals little by little after some training sessions. As a result, we confirmed the performance and availability of the developed system with experimental user's bio-potentials.

The Correlation of Refractive Error and Ocular Dimensions in Older Age (고령의 연령에서 굴절이상과 안광학 성분들의 연관성 분석)

  • Lim, Byung Kwan;Jeon, Soon-Woo;Jeong, Youn Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.293-297
    • /
    • 2011
  • Purpose: This study was to know the correlation among refractive error and the dimensions of ocular components on older adults. Methods: The subjects were 95 older age who had no eye diseases. The refractive error, corneal radius, corneal diopter, axial length, anterior chamber depth and lens thickness were measured and analysed. Results: The axial length(AL)/corneal radius(CR) ratio was positively correlated with the corneal diopter, axial length, the anterior chamber depth. Then it was negatively correlated with corneal radius. It was shown that the highest correlation was between the corneal diopter and axial length (r = -0.545, p = 0.000). The spherical equivalent of the refractive error was negatively correlated with the AL/CR ratio. Conclusions: It was shown that the AL/CR ratio was a very important indicator for diagnosing the refractive error of the old age.

Suggestion of a Basis Color and Standardization for Observing a Person's Face Color of Ocular Inspection (한방 망진의 찰색을 위한 표준화 및 색 기준 설정안의 제안)

  • Lee, Se-Hwan;Kim, Bong-Hyun;Cho, Dong-Uk
    • The KIPS Transactions:PartB
    • /
    • v.15B no.5
    • /
    • pp.397-406
    • /
    • 2008
  • Despite the effectiveness of oriental medical practice in the diagnosis of symptoms and providing cure to it, the preferences in western medicinal values is socially prevalent. The diagnosis of a disease using western medicinal practices provides us with an objective diagnostic result, however, decisions by oriental doctors are based on their heuristic intuitions developed by practice and experience. Objective solutions for the cure of symptoms using oriental medical therapy can have a high impact on the world market. Therefore, development of diagnostic machines based on oriental therapy can enhance the Ocular Inspection which is evaluated as one of the best diagnostic treatment among Oriental Medical Science, is not researched much compared to other diagnoses. Because there is no color diagnosis rules for digital machines to analyze the actual color, looking at the person's face color is one of the most important components to diagnose the disease or illness. The thesis proposes the implementation of absolute observing a person's face color standards of the color settings for objective diagnosis. As a results, comparative digital color analysis for observing a person's face color can be the most effective rule based Color scheme system to diagnose disease. A standard solution for the researching conditions is suggested to reduce the variable which may occur depending on the differences between the researching conditions.

Sex Steroid Hormone and Ophthalmic Disease (성호르몬과 안질환)

  • Kim, Jin-Ju;Yu, Hyeong-Gon;Ku, Seung-Yup
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.37 no.2
    • /
    • pp.89-98
    • /
    • 2010
  • Sex and its tropic hormones influence the lacrimal system, corneal anatomy and disease, aqueous humor dynamics and glaucoma, crystalline lens and cataract, and retinal disease. Dry eye occurs especially frequently during pregnancy, oral contraceptive use, and after menopause, during which androgen levels decrease. Androgen control development, differentiation, and lipid production of sebaceous glands throughout the body, and androgen deficiency also leads to meibomian gland dysfunction and evaporative dry eye. On the other hand, estrogen causes a reduction in size, activity, and lipid production of sebaceous glands. Sex and its tropic hormones also influence the corneal anatomy and disease, and corneal thickening occurred on the second day of the menstrual cycle and around the time of ovulation and appeared to be related to estrogen levels. Fuchs' dystrophy is more commonly seen in postmenopausal women than men and may be linked to hormonal changes that occur with aging. In addition, overexpression of estrogen and progesterone receptors in the conjunctiva of vernal keratoconjunctivitis patients. Serum progesterone levels also may be associated with intraocular pressure especially in pregnant women, and for the women. For women with cataracts, hormone levels were typical of menopause, and there was a significant negative correlation between estradiol and follicular stimulating hormone levels. In addition, serum testosterone levels are associated with the development of diabetic retinopathy. Although the role of sex hormones on the eye is largely unknown, and the results should be interpreted with caution until replicated, the functions of sex hormones in ocular disease remains to be investigated, because they may be involved in structure and function of the ocular components, which are important in the pathogenesis of ocular disease.

Study of the Correlation and Ocular Components in Preschool Children (취학전 어린이들의 안광학 성분 측정 및 상관성 분석)

  • Jeon, Soon-Woo;Hwang, Hye-Kyung;Lee, Sun Haeng;Park, Chun-Man
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.201-206
    • /
    • 2010
  • Purpose: This study was to know the correlation among the dimensions of ocular components and refractive error on kindergarten children. Methods: The subjects were 80 preschool students who had no eye diseases. The refraction, corneal diopter, corneal radius, inter-pupillary distance, axial length, anterior chamber depth and dominant eye were measured and analysed. Results: It was shown that the highest correlation was between the axial length and the corneal diopter (r=-0.674, p=0.000). The ratio of height, weight and axial length (AL) to Corneal radius (CR) ratio were positively correlated with the axial length (r=0.351, r=0.408, r=0.488). The spherical equivalent of the refractive error and the corneal diopter were negatively correlated with the axial length (r=-0.302, r=-0.674). The anterior chamber depth and the corneal diopter were positively correlated with the AL/CR ratio (r=0.422, r=0.280). The spherical equivalent of the refractive error and the corneal radius were negatively correlated with the AL/CR ratio. Conclusions: It was shown that the AL/CR ratio was a very important indicator for diagnosing the refractive error of the preschoolers.

Study of the Axial Length/Corneal Radius Ratio in Determining the Refractive State of the Eye (굴절이상과 안축장/각막곡률반경 비와의 관계에 관한 연구)

  • Seo, Y.W.;Choe, Y.J.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.23-31
    • /
    • 1999
  • The purpose of this study is to evaluate the relationship between axial length/corneal radius ratio and refractive error for human eye. Ocular components were measured Baush & Lomb keratometer, Holden-Payor pachometer, and Stoz Compuscan. Refractive error was measured by subjective refraction. The results were as follows; 1) Spherical equivalent refractive error and axial length/corneal radius ratio was very highly correlated with the correlation coefficient for -0.89. 2) Axial length/corneal radius ratio and axial length, vitreous chamber depth were highly correlated that the correlation coefficients were 0.82, 0.80 respectively. 3) Axial length/corneal radius ratio and anterior chamber depth, corneal power, corneal radius, lens power were correlated with the correlation coefficients for 0.57, 0.40, -0.39, -0.35 respectively. 4) There were no significant correlation between axial length/corneal radius ratio and lens thickness, and corneal thickness.

  • PDF