• Title/Summary/Keyword: Occurrence of fires

Search Result 104, Processing Time 0.027 seconds

How to Reduce Fire Fatalities in Residential Occupancies on the Way to a Rapidly Aging Society?

  • Sekizawa, Ai
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2006.04a
    • /
    • pp.29-40
    • /
    • 2006
  • Everybody may be vulnerable to fires depending on the time, place, and circumstances. Fire statistics show that the occurrence of fire death depends not only on the severity of a fire itself, but also largely on the conditions of occupants such as physical functions, the environment around occupants, and the type of facility where are fire occurs. The review of fire safety from the viewpoint of vulnerable populations does not simply mean additional special attention and care only to high risk groups, but instead it means significant review of fire safety design and systems for all people from a more universal standpoint. Therefore, in order to examine the strategies of a fire death-reduction program, safety measures suitable for the relevant high-risk groups considering the type of vulnerable person, the type of fire, and the type of building in residential occupancies. Solutions will require strenuous multilateral effort and flexibility.

  • PDF

An Experimental Study on the Effect of Rotation Strength on Fire Whirl Characteristics (회전강도가 Fire Whirl의 특성에 미치는 영향에 관한 실험연구)

  • Choi Sang-Yeol;Ryou Hong-Sun
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.2 s.70
    • /
    • pp.11-17
    • /
    • 2005
  • Rotational motion in the atmosphere around a fire may have a profound influence on the fire plume. This process underlies the occurrence of fire whirls. Fire whirls are rare but highly destructive phenomenon which were observed in a large forest, urban and building fires. The present study aims to investigate of the effect of rotation Strength on the fire whirl characteristics expeimentally. Experiments are performed for various sizes of fire source with different rotation strength. From the experimental observations, it is noted that the mean centerline temperature is gradually increased and mean radial temperature is decreased as increases rotation strength. The characteristic mean flame height of fire based on the visible observation is increased as increases of dimensionless swirl parameter, $\Omega/\alpha$, represented by swirl induced motion to buoyancy driven motion.

Breakdown voltage characteristics of air with vertical arranged electrodes due to flame (화염에 의한 수직배치전극에서 공기의 절연파괴전압특성)

  • Kim, C.N.;Jee, S.W.;Lee, K.S.;Lee, D.I.;Kim, I.S.;Kim, L.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1735-1737
    • /
    • 2001
  • The occurrence of fires under transmission lines is responsible for a great number of power line outages. In this paper, the ac flashover voltages and the corona onset voltages of a needle-plane electrode gap of vertical arrangement in the presence of flame were investigated. We also observed the corona discharge current and variation of shapes in flame with increasing the applied voltages. We found that the corona onset voltages and the flashover voltages were drastically decreased with the position of flames and gap length of electrodes, and observed that the deflection or fluctuation phenomena in the shape of flames.

  • PDF

The Applicability Analysis of Life Safety Codes for High Fire Risk Building Applications (화재 위험성을 중심으로 한 건축물 용도별 한국형인명안전기준의 적용성 검토에 관한 연구)

  • Koo, In-hyuk;Kim, Hye-Won;Jin, Seung-Hyeon;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.103-104
    • /
    • 2022
  • In Korea, the occurrence and risk of similar fires are high, so setting up fire prevention measures through fire case investigation is considered the most basic measure in securing human safety. In particular, calculation of evacuation capacity in evacuation safety design of buildings is the most important factor that directly affects evacuation safety performance. However domestic standards is not consider about occupant characteristics. also the case of domestic, it has the problem that the law is partially applied when the fire safety design of buildings. Therefore, the purpose of this study is to study the current status and related regulations of the life safety code for the application of high fire risk buildings, and to analyze the difference in evacuation time through Case Study.

  • PDF

Influence of flame on flashover characteristics of model transmission line (모의 송전선로의 섬락특성에 미치는 화염의 영향)

  • Kim, I.S.;Kim, C.N.;Jee, S.W.;Lee, S.W.;Lee, K.S.;Lee, D.I.;Kim, L.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1738-1740
    • /
    • 2001
  • The occurrence of fires under transmission lines is responsible for a great number of power line outages. In this paper, the ac flashover voltages and the corona onset voltages of a model transmission line in the presence of flame were investigated. We found that the corona onset voltages and the flashover voltages were varied with the position of flames. Flashover voltages of vertical arranged electrodes with flame appeared to decrease 43[%] lower than those of same conditions with no flame.

  • PDF

Establishment of the Method for Evaluating the Risk of Fire Spread to the Upper Floors due to Ejected Flame from an Opening in the Building Fires (건축물 화재시 개구분출화염으로 인한 상층부로의 화재확대 위험성평가 방법 구축)

  • Shin, Yi-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.216-217
    • /
    • 2020
  • As the fire inside the building grows rapidly, ejected flame from an opening occurs due to flashover. As a result, the number of cases where the flame spreads to the exterior of the building and rapidly expands to the upper floor is increasing. In particular, in the case of the fire in the Daebong Green Apartment, Uijeongbu in 2015, it was a case where the flame spread to adjacent buildings due to the opening eruption flame from the first ignited building, causing great damage to three apartments. Therefore, this study is to introduce an international standard under development that estimates the shape and properties of the ejected flame from an opening and quantitatively evaluates the radiant heat flux received by the exterior wall of the building by assuming the occurrence of the ejected flame from an opening.

  • PDF

Development of a Tool for Predicting the Occurrence Time of BLEVE in Small LPG Storage Tanks (LPG소형저장탱크 BLEVE 발생 시점 예측 툴 개발)

  • Chae, Chung Keun;Lee, Jae Hun;Chae, Seung Been;Kim, Yong Gyu;Han, Shin Tak
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.4
    • /
    • pp.74-83
    • /
    • 2020
  • In Korea, about 110,000 LPG small storage tanks of less than three tons have been installed in restaurants, houses and factories, and are used as LPG supply facilities for cooking, heating and industrial use. In the case of combustible liquefied gas storage tanks, the tank may rupture due to the temperature increase of the tank steel plate (approximately 600℃) even when the safety valve is operating normally, causing large-scale damage in an instant. Therefore, in the event of a fire near the LPG small storage tank, it is necessary to accurately predict the timing of the BLEVE(Boiling Liquid Expanding Vapour Explosion) outbreak in order to secure golden time for lifesaving and safely carry out fire extinguishing activities. In this study, we have first investigated the results of a prior study on the prediction of the occurrence of BLEVE in the horizontal tanks. And we have developed thermodynamic models and simulation program on the prediction of BLEVE that can be applied to vertical tanks used in Korea, have studied the effects of the safety valve's ability to vent, heat flux strength of external fires, size of tanks, and gas remaining in tanks on the time of BLEVE occurrence and have suggested future utilization measures.

Development of Forest Fire Occurrence Probability Model Using Logistic Regression (로지스틱 회귀모형을 이용한 산불발생확률모형 개발)

  • Lee, Byungdoo;Ryu, Gyesun;Kim, Seonyoung;Kim, Kyongha
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • To achieve the forest fire management goals such as early detection and quick suppression, fire resources should be allocated at high probability area where forest fires occur. The objective of this study was to develop and validate models to estimate spatially distributed probabilities of occurrence of forest fire. The models were builded by exploring relationships between fire ignition location and forest, terrain and anthropogenic factors using logistic regression. Distance to forest, cemetery, fire history, forest type, elevation, slope were chosen as the significant factors to the model. The model constructed had a good fit and classification accuracy of the model was 63%. This model and map can support the allocation optimization of forest fire resources and increase effectiveness in fire prevention and planning.

A Study on the Correlation between Fire Statistics and GNI(Gross National Income) (국민소득과 화재발생 건수의 상관관계에 관한 연구)

  • Choi, Jin-Man;Choi, Jae-Sung;Choi, Don-Mook
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.4
    • /
    • pp.147-152
    • /
    • 2009
  • As a results of comparing with fire occurrences and gross national income(GNI), annual fire increasing rate has been 5.6%, and that of GNI has been 11% for the past 55 years. As GNI shows 5.4% higher than fire occurrences, economy growing rate is faster than that of fires. In addition, study has been done every 10 years from 1950's to 2000's. Fire occurrences increase twice as much annually and GNI increases above 3.3 times as much.

A Study on the Improvement of Life Safety Codes for High Fire Risk Building Applications (II) (화재 위험성을 중심으로 한 건축물 용도별 한국형인명안전기준의 개선안 도출에 관한 연구(II))

  • Koo, In-hyuk;Kim, Hye-Won;Jin, Seung-Hyeon;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.75-76
    • /
    • 2022
  • In Korea, the occurrence and risk of similar fires are high, so setting up fire prevention measures through fire case investigation is considered the most basic measure in securing human safety. Therefore, the purpose of this study is to research status and related regulations of Life Safety Codes for High Fire Risk Building Applications In the future, using this as basic data, it is considered that additional research is need to development Human Safety Standards in Korea.

  • PDF