• Title/Summary/Keyword: Occupational health and safety

Search Result 2,906, Processing Time 0.034 seconds

Effect of the Organization's Autonomous Working Environment and Trust among Members on Workers' Job Immersion (조직의 자율적 근로환경과 구성원 간 신뢰가 근로자의 직무몰입에 미치는 영향)

  • Eun-Soo Han;Jong-Hyeon Hwang;Dong-Hyung Lee
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.46 no.2
    • /
    • pp.13-21
    • /
    • 2023
  • In the recent era of the fourth industrial revolution, many industries aim to maximize the efficiency of products and services by introducing cutting-edge technologies such as artificial intelligence and big data. In this situation, organizational culture is changing a lot due to the influx of the MZ generation with strong individualistic tendencies and the decreased face-to-face communication between members. However, active communication with colleagues is still essential to maximize performance, and the margins created by simplifying work processes and automating processes must be used for creating work performance. This requires cooperation and commitment through the job immersion of members who have an active attitude. This study analyzed how the organization's autonomous work environment and trust among members, which are creative work performance conditions, affect job immersion using raw data from the Occupational Safety and Health Research Institute. As a result, it was found that both the organization's autonomous working environment and trust among members significantly effected the members' job immersion. in order to achieve productivity and value improvement in companies, efforts are needed to increase workers' job immersion by building an autonomous working environment and trust among members. The results of this study are expected to contribute significantly to the search for ways to increase workers' job commitment to improve organizational productivity.

A Study on Reliability Flow Diagram Development of Chemical Process Using Directed Graph Analysis Methodology (유향그래프 분석기법을 이용한 화학공정의 신뢰도흐름도 개발에 관한 연구)

  • Byun, Yoon Sup;Hwang, Kyu Suk
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.41-47
    • /
    • 2012
  • There are PFD(Process Flow Diagram) and P&ID(Piping and Instrument Diagram) for designing and managing chemical process efficiently. They provide the operation condition and equipment specifications of chemical process, but they do not provide the reliability of chemical process. Therefore, in this study, Reliability Flow Diagram(RFD) which provide the cycle and time of preventive maintenance has been developed using Directed Graph Analysis methodology. Directed Graph Analysis methodology is capable of assessing the reliability of chemical process. It models chemical process into Directed Graph with nodes and arcs and assesses the reliability of normal operation of chemical process by assessing Directed Graph sequential. In this paper, the chemical process reliability transition according to operation time was assessed. And then, Reliability Flow Diagram has been developed by inserting the result into P&ID. Like PFD and P&ID, Reliability Flow Diagram provide valuable and useful information for the design and management of chemical process.

Study about the Applicable Plan of GIS on Range of Magnetic Field Emitted from 60 Hz Powerline (60Hz 고압 송전선로의 자기장 발생범위에 대한 GIS 적용 방안에 대한 연구)

  • Hong, Seung Cheol;Choi, Seong Ho;Kim, Yoon Shin;Park, Jae Young
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.4
    • /
    • pp.271-277
    • /
    • 2006
  • In this study, we investigated the applicable plan of GIS on the environmental impact assessment of 60 Hz Powerline. So we assessed distance data based on calculations by use of 2D and 3D Geographical information systems(GIS) and distance data based on measurements on 1: 5000 maps accord with on site distance measurements to use input data for calculating magnetic field. One hundred eight of the on site measured addresses were selected from residences. The data were achieved by measuring the distance between residence and power line on maps with scales of 1: 5000. The digital map was obtained from National Geographic Information Institute with scales of 1: 5000, and we made 2D and 3D map. Correlation analyses were performed for statistical analyses. For the 3D GIS versus on site comparison of different exposure categories, 70 of 108 measurements were assigned to the correct category. Similarly for 2D GIS versus on site comparison, 71 of 108 were correctly categorized. When comparing map measurement with on site measurement, 62 of 108 were correctly categorized. When the correlation analysis was performed, best correlation was found between 3D GIS and on site measurements with r = 0.84947 (p<0.0001). The correlation between map and on site measurement yielded an r of 0.76517 (p<0.0001). Since the GIS measurements and map measurement were made from the center point in the building and the on site measurements had to be made from the closest wall on the building, this might introduce and additional error in urban areas. The difference between 2D and 3D calculations were resulted from the height of buildings.

Measurement of Autoignition Temperature of n-Propanol and Formic acid System (n-Propanol과 Formic acid계의 최소자연발화온도의 측정)

  • Cho, Young-Se;Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.64-69
    • /
    • 2013
  • The autoignition temperatures (AITs) of solvent mixture was important index for the safe handling of flammable liquids which constitute the solvent mixtures. This study measured the AITs and ignition delay time for n-propanol and formic acid system by using ASTM E659 apparatus. The AITs of n-Propanol and Formic acid which constituted binary system were $435^{\circ}C$ and $498^{\circ}C$, respectively. The experimental AITs of n-propanol and formic acid system were a good agreement with the calculated AITs by the proposed equations with a few A.A.D. (average absolute deviation). And n- Propanol and formic acid system was shown the minimum autoignition temperature behavior (MAITB).

Measurement and Prediction of Combustuion Properties of di-n-Buthylamine (디노말부틸아민의 연소특성치 측정 및 예측)

  • Ha, Dong-Myeong
    • Journal of Energy Engineering
    • /
    • v.28 no.4
    • /
    • pp.42-47
    • /
    • 2019
  • In this study, combustion characteristics were measured by selecting di-n-buthylamine, which is widely used as an emulsifier, insecticide, additive, rubber vulcanization accelerator, corrosion inhibitor, and raw material for dye production. The flash point of the di-n-buthylamine was measured by Setaflash, Pensky-Martens, Tag, and Cleveland testers. And the AIT of the di-n-buthylamine was measured by ASTM 659E. The explosion limits of the di-n-buthylamine was calculated using the measured flash points by Setaflash tester. The flash point of the di-n-buthylamine by using Setaflash and Pensky-Martens closed-cup testers were experimented at 38 ℃ and 43 ℃, respectively. The flash points of the di-n-buthylamine by Tag and Cleveland open cup testers were experimented at 48 ℃. The AIT of the di-n-buthylamine was experimented at 247 ℃. The LEL and UEL calculated by using lower and upper flash points of Setaflash tester were calculated at 0.69 vol% and 7.7 vol%, respectively. The measurement of the flash point measurement and the calculation method of the explosion limit prediction presented in this study can be used to study the fire and explosion characteristics of the other combustible liquids.

The Measurement of Combustible Characteristics of n-Undecane (노말언데칸의 연소특성치의 측정)

  • Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.11-17
    • /
    • 2013
  • For the safe handling of n-undecane, the lower flash points and the upper flash point, fire point, AITs (auto-ignition temperatures) by ignition delay time were experimented. Also lower and upper explosion limits by using measured the lower and upper flash points for n-undecane were calculated. The lower flash points of n-undecane by using closed-cup tester were measured $59^{\circ}C$ and $67^{\circ}C$. The lower flash points of n-undecane by using open cup tester were measured $67^{\circ}C$ and $72^{\circ}C$, respectively. The fire point of n-undecane by using Cleveland open cup tester was measured $74^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus for n-undecane. The experimental AIT of n-undecane was $198^{\circ}C$. The estimated lower and upper explosion limit by using measured lower flash point $59^{\circ}C$ and upper flash point $83^{\circ}C$ for n-undecane were 0.65 Vol.% and 2.12 Vol.%.

The Measurement and Prediction of Combustible Properties for Ethylbenzene (에틸벤젠의 연소특성치 측정 및 예측)

  • Ha, Dong-Myeong
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.169-175
    • /
    • 2014
  • For the safe handling of ethylbenzene, this study was investigated the explosion limits of ethylbenzene in the reference data. And the lower flash points, upper flash points and AITs(auto-ignition temperatures) by ignition delay time were experimented. The lower flash points of ethylbenzene by using Setaflash closed-cup and Pensky-Martens closed-cup testers were experimented $20^{\circ}C$ and $22^{\circ}C$, respectively. The lower flash points ethylbenzene by using Tag and Cleveland open cup testers were experimented $25^{\circ}C$ and $28^{\circ}C$, respectively. Also, this study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for ethylbnezene. The experimental AIT of ethylbenzene was $430^{\circ}C$. The calculated LEL and UEL by using the measured lower flash point and upper flash point were 0.93 Vol.% and 7.96 Vol.%, respectively.

The Study on Measurement and Prediction of Combustible Properties for Aniline (아닐린의 연소특성치의 측정 및 예측에 관한 연구)

  • Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.4
    • /
    • pp.44-50
    • /
    • 2014
  • For the safe handling of aniline, this study was investigated the explosion limits of aniline in the reference data. And the lower flash points, upper flash points and AITs(auto-ignition temperatures) by ignition delay time were experimented. The lower flash point of aniline by using Setaflash and Penski-Martens closed-cup testers were experimented $66^{\circ}C$ and $73^{\circ}C$, respectively. The lower flash point aniline by using Tag and Cleveland open cup testers were experimented $72^{\circ}C$ and $78^{\circ}C$, respectively. Also, this study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for aniline. The experimental AIT of aniline was $590^{\circ}C$. The calculated LEL and UEL by using the measured low flash point and upper flash point were 1.16 Vol.% and 8.36 Vol.%, respectively.

Association between Employment Status and the Prevalence of COPD for Manufacturing and Construction Workers (제조업 및 건설업 근로자들의 근로 형태와 COPD발생 간의 연관성)

  • Kim, Jennifer Ivy;Seo, Hyekyung;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.4
    • /
    • pp.365-373
    • /
    • 2018
  • Objective: This study aims to analyze the relationship between employment status and the prevalence of chronic obstructive pulmonary disease (COPD) for manufacturing and construction workers. Methods: Subjects, who had or have worked as temporary workers in manufacturing or construction worksites for the longest career years, were extracted from the KNHANES(2007-2009) database. Characteristics of demographical, socio-economic, and smoking history were treated as independent variables. Considering that smoking experience and age are significantly influential in the prevalence of COPD, logistic regressions were analyzed after stratifying subjects according to their smoking experience and age. A two-stage stratified systematic sampling method was applied for the logistic regression analysis. Results: Age, gender, and household income level were associated with the prevalence of COPD in both smoking and non-smoking groups. However, employment status was only significant among smoking group. Smoking experience and age were significantly related to the prevalence of COPD among all age groups. In addition, employment status and household income level were also associated with the prevalence of COPD in young aged group. But gender was the only significant factor among the elder group. Conclusions: This study confirmed that employment status was a major social factor which may be related to the prevalence of COPD. Proper supports such as providing safety measures should be provided to temporary workers to manage their respiratory health.

A Study on Job Hazard Factors through Analysis of Musculoskeletal Diseases and Job Stress of Teachers (교사의 근골격계 질환 및 직무 스트레스의 분석을 통한 직무 유해요인에 관한 연구)

  • Kim, Seung-yeon;Jeong, Myeongjin;Seo, Ye-seul;Yoon, Eun-been
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.163-170
    • /
    • 2021
  • The purpose of this study is to identify the harmful factors of teacher's job stress and occupational-related musculoskeletal diseases, and to investigate according to job types to seek solutions and improvement measures for removing harmful factors. A total of 168 elementary and high school teachers in Seoul were surveyed. As a result, the average RULA score of the teacher was 4.2 points, and the average RULA score of the teacher who did not complain of musculoskeletal diseases was 4.3 points. In addition, the average job stress score of the teacher was 58.9 points, and the stress score by factor was in the order of student guidance, work burden, loss of authority, organizational structure and curriculum, treatment and welfare, human relations. As a result of analyzing the teacher's RULA score and job stress, it was possible to derive a correlation between musculoskeletal disorders and job stress caused by occupation.