• Title/Summary/Keyword: Occupational Radiation Exposure

Search Result 116, Processing Time 0.019 seconds

Discussion of Exposure Evaluation Associated with Extremely Low Frequency-magnetic Field in the Case of Portable Hand-held Fans (휴대용 손 선풍기의 극저주파 자기장 발생 수준 평가와 쟁점 고찰)

  • Park, Dong-Uk;Yi, Seongjin;Kim, So-Youn;Bae, Seo-Youn;Choi, Sangjun;Kim, Won;Min, Sung Hyon;Park, Jihoon;Ahn, Jongju
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.5
    • /
    • pp.480-490
    • /
    • 2018
  • Objective: This study aimed to report the level of extremely low frequency-magnetic field (ELF-MF) emitted by portable hand-held fans (HHF) and to discuss the methodologies for determining the health risk of ELF-MF for HHF products. Method: ELF-MF was monitored at eight locations by distances in the vicinity of HHFs. A total of 13 HHF brands on the market were randomly selected. A portable ELF-MF monitor MDEX II was used to measure the ELF-MF level in the range of 40-800 Hz with a resolution of $0.01{\mu}T$. This study also examined the frequency results of a total of 45 HHF products investigated by the Korean Ministry of Science and ICT (KMSICT). Results: ELF-MF higher than $0.3{\mu}T$ was found to be emitted at a distance of less than 20 cm from 12 HHF. ELF-MF emitted from four products was found to exceed the reference level ($83.3{\mu}T$ based on 60 Hz) recommended by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). KMSIT reported that the principle frequency emitted from the HHFs ranged from 54 Hz to 284 kHz, without the level of LEF-MF. Unscientifically, the KMSICT used the reference level by ICNIRP as the chronic level and concluded that all HHFs are safe with a basis of 1.2-36.0% less than the reference level. Conclusion: The HHF emitted much higher levels of ELF-MF than $0.3-0.4{\mu}T$, which is regarded as the reference level for childhood leukemia. The risk of HHF should be examined in terms of whether they can be used by the general public, including children and pregnant woman.

Comparison of Lens Dose in accordance with Bismuth shielding and Patient position in Brain perfusion CT (Brain Perfusion CT에서 Bismuth 차폐와 환자의 자세 변화에 따른 수정체 선량 비교 연구)

  • Gang, Eun Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.47-52
    • /
    • 2018
  • Brain perfusion CT scanning is often employed usefully in clinical conditions as it accurately and promptly provides information about the perfusion state of patients having acute ischemic stroke with a lot of time constraints and allows them to receive proper treatment. Despite those strengths of it, it also has a serious weakness that Lens may be exposed to a lot of dose of radiation in it. In this study, as a way to reduce the dose of radiation to Lens in brain perfusion CT scanning, this researcher conducted an experiment with Bismuth shielding and change of patients' position. TLD (TLD-100) was placed on both lens using the phantom (PBU-50), and then, in total 4 positions, parallel to IOML, parallel to IOML (Bismuth shielding), parallel to SOML, and parallel to SOML (Bismuth shielding), brain perfusion scanning was done 5 times for each position, and dose to Lens were measured. Also, to examine how the picture quality changed in different positions, 4 areas of interest were designated in 4 spots, and then, CT number and noise changes were measured and compared. According to the results of conducting one-way ANOVA on the doses measured, as the significance probability was found to be 0.000, so there was difference found in the doses of radiation to crystalline lenses. According to the results of Duncan's post-hoc test, with the scanning of being parallel to IOML as the reference, the reduction of 89.16% and 89.66% was observed in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding) respectively, so the doses to Lens reduced significantly. Next, in the scanning of being parallel to IOML (Bismuth shielding), the reduction of 37.12% was found. According to the results, reduction in the doses of radiation was found the most significantly both in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding). With the limit of the equivalent dose to Lens as the reference, this researcher conducted comparison with the dose to occupational exposure and dose to Public exposure in the scanning of being parallel to IOML and found 39.47% and 394.73% respectively; however in the scanning of being parallel to SOML (Bismuth shielding), considerable reduction was found as 4.08% and 40.8% respectively. According to the results of evaluation on picture quality, every image was found to meet the evaluative standards of phantom scanning in terms of the measurement of CT numbers and noise. In conclusion, it would be the most useful way to reduce the dose of radiation to Lens to use shields in brain perfusion CT scanning and adjust patients' position so that their lens will not be in the field of radiation.

A Case of Non-cardiogenic Pulmonary Edema caused by Nitrogen Dioxide Poisoning after Cutting Copper Pipe with an Oxyethylene Torch (산소 에틸렌 토치로 동파이프 절단작업 후 발생한 이산화질소 중독에 의한 비심인성 폐부종 1례)

  • JeGal, Yang-Jin;Ahn, Jong-Joon;Seo, Kwang-Won;Cha, Hee-Jeong;Kwon, Woon-Jung;Kim, Yang-Ho
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.4 no.2
    • /
    • pp.175-179
    • /
    • 2006
  • Welders are exposed to a number of hazards including metal fumes, toxic gases, electricity, heat, noise, and radiation such as ultraviolet and infrared light. We encountered a patient who developed non-cardiogenic pulmonary edema within a day after cutting copper pipe with an oxyethylene torch. The patient was a 26-year-old welder. He complained of dyspnea, generalized myalgia, and febrile sensation the following morning. The patient's chest X-ray and chest CT scan showed extensively distributed and ill-defined centrilobular nodules. Both his symptoms and chest X-ray abnormalities improved spontaneously. We attributed the patient's symptoms to non-cardiogenic pulmonary edema due to nitrogen dioxide, reasoning that: 1) the pipe consisted only of copper, according to material safety data sheet (MSDS); 2) a previous report in the literature demonstrated increased nitrogen dioxide levels under similar conditions; 3) the patient's clinical course and radiologic findings were very reminiscent of non-cardiogenic pulmonary edema following accidental exposure to nitrogen dioxide.

  • PDF

A Study on the Removal Method of Radioactive Corrosion Product using its Magnetic Property (방사성 부식생성물의 자기적 성질을 이용한 제거방법에 대한 연구)

  • 송민철;공태영;이건재
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.1 no.1
    • /
    • pp.73-79
    • /
    • 2003
  • In a pressurized water reactor, radioactive corrosion products (CRUD) in primary coolant system are one of the major sources for the occupational radiation exposure of the personnel in a nuclear power plant. Through the recent trend of long term fuel cycle in a nuclear power Plant, radioactive corrosion products deposited in reactor core for a long time are also the cause of Axial Offset Anomaly (AOA) having m effect on reactor power by the hideout of boron. CRUD consist primarily of magnetite, nickel ferrite, cobalt ferrite, and so on. They have the characteristic of strong magnetism. Therefore it is performed the conceptual design to develop the filter which removes the CRUD by magnetic field that is generated by an arrangement of permanent and electric magnets. Contrary to the conventional filter, the proposed filter does not interrupt the fluid flow, so there is little pressure drop and it can be used continuously. It is expected to be applied as one of the technologies for removal of the CRUB.

  • PDF

Conceptual Design of the Filter using Electromagnet and Permanent Magnets for Removal of Radioactive Corrosion Products (방사성 부식생성물 제거를 위한 전자석 및 영구자석을 이용한 필터의 개념설계)

  • 송민철;공태영;이건재
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.38-42
    • /
    • 2003
  • In a pressurized water reactor, radioactive corrosion products (CRUD) in primary coolant system are one of the major sources for the occupational radiation exposure of the personnel in a nuclear power plant. Through the recent trend of long term fuel cycle in a nuclear power plant, radioactive corrosion products deposited in reactor core for a long time are also the cause of Axial Offset Anomaly (AOA) having an effect on reactor power by the hideout of boron. CRUD consist primarily of magnetite, nickel ferrite, cobalt ferrite, and so on. They have the characteristic of strong magnetism. Therefore it is peformed the conceptual design to develop the filter which removes the CRUD by magnetic field that is generated by an arrangement of permanent and electric magnets. Contrary to the conventional filter, the proposed filter does not interrupt the fluid flow, so there is little pressure drop and it can be used continuously. It is expected to be applied as one of the technologies for removal of the CRUD.

  • PDF

The Relationship between Behavior of Radiographic Safety Control and Job Stress in Dental Hygienist (치과위생사의 방사선안전관리 행위와 직무스트레스와의 관계)

  • Jang, Jong-Hwa;Hwang, Su-Lyun;Jung, Hong-ryang
    • Journal of dental hygiene science
    • /
    • v.10 no.4
    • /
    • pp.265-271
    • /
    • 2010
  • This study was to investigate the level of knowledge, recognition, behavior of radiographic safety control and job stress in dental hygienists and to determine the relationship among variables. The subjects were 256(56.9%), who were worked in dental hospital and clinic with mean age of $29.59{\pm}7.30$. Data was collected using a self administrated questionnaire from April 4 to May 15, 2010. Behavior of radiographic safety control was measured using the 15-items and job stress was measured using the 5-items with 5-point likert scale. The data were analyzed with t-test, one-way ANOVA and pearson correlation coefficient using the SPSS WIN 17.0 program. Regarding job stress, the subjects was a mean of 2.63 out of a maximum 5 points. The level of knowledge, recognition, behavior of radiographic safety control a mean of 3.11, 4.08 and 3.43 out of a maximum 5 points. Recognition and behavior of radiographic safety control was negative related job stress in this study. Based on the findings, behavior of radiographic safety control is associated with job stress. These results suggest that various program should be considered for radiation safety control of dental hygienists.