• 제목/요약/키워드: Occlusions

검색결과 186건 처리시간 0.035초

개방교합자의 설근과 구륜근 활성도에 관한 연구 (AN ELECTROMYOGRAGHIC STUDY OF MUSCULAR ACTIVITIES OF TONGUE AND LIP MUSCLES IN ANTERIOR OPEN-BITE)

  • 최연석;이기수;박영국
    • 대한치과교정학회지
    • /
    • 제24권2호
    • /
    • pp.233-246
    • /
    • 1994
  • The purpose of the present study was to investigate the difference of muscular activities of the tongue and lip muscles between anterior open-bite and normal occlusion during various function. Thirty eight subjects of 12.1-39.6 years were employed in this study : Eighteen subjects were anterior open-bites and tweenty subjects were normal occlusions. During rest position, maximum effort of lip sealing, command swallow of saliva and sucking & swallowing of juice, the electromyographic datas of the genioglossus, superior longitudinal muscle of tongue, upper and lower orbicularis oris were recorded and integrated with Medelec MS 25 electromyographic machine. Lateral cephalometric radiographs were taken on all subjects for the analysis of tongue posture and size. All data were recored and statistically processed. The findings of this study can be summerized as follows : 1. During the rest position, muscular activity of tongue was higher than that of lip muscle in open-bite, but no difference in normal occlusion group. 2. During the swallowing of juice, the activity of orbicularis oris was higher than that of genioglossus in open-bite. But the normal occusion was showed higher activity of tongue during the swallowing of juice. 3. The open-bite, compared to the normal occlusion, had higher value of tongue muscle activity during the rest position. 4. Compared to normal occlusion group, the open-bite had higher value of lip muscle activity during the sucking and swallowing of juice. 5. During the command swallow of saliva, the normal occlusion was showed harmonious swallowing pattern, but the open-bite showed much variation and disharmony in muscular contraction sequence, tended to absent of lip muscle activity. 6. At the lateral cephalometric radiographs, compared to the normal occlusion, the open-bite was showed lower tongue posture. But no difference was found in intermaxillary space. It is suggested that the open-bite, compared to the normal occlusion, had higher muscular activity of tongue during the rest position and various functions, showed lower tongue posture on the lateral cephalogram. In the development of anterior open-bite malocclusion, these factors may be an etiologic factor.

  • PDF

비강수술로 호전된 폐쇄성 수면무호흡증후군 1 례 (One Case of Nasal Surgery in Obstructive Sleep Apnea Syndrome)

  • 최지호;이흥만;권순영;이상학;신철;이승훈
    • 수면정신생리
    • /
    • 제12권1호
    • /
    • pp.64-67
    • /
    • 2005
  • 폐쇄성 수면무호흡증은 이비인후과영역에서 흔하게 관찰되는 질환 중 하나로 수면 중에 상기도의 폐쇄로 인한 호흡정지가 주요한 병인이며 상기도를 구성하는 비강, 구강, 인두, 후두 중 어느 한 부분에서 폐쇄가 일어나도 질환의 원인이 될 수 있다. 비폐색의 가능한 원인들로는 주로 비중격 만곡, 비용, 기포성 갑개, 후비공 폐쇄, 종양, 이물, 술 후 또는 외상 후 발생한 유착, 여러 가지 비염, 기타 질환 등이 있다. 폐쇄성 수면무호흡증의 수술적 치료에는 비강수술, 구개인 두수술, 편도 및 아데노이드 절제술, 설부 축소수술, 기관절개술 등 여러 가지가 있는데 문헌들을 고찰한 결과 지금까지 성인에서 수면무호흡증 치료로 시행한 비강수술의 효과에 대해서는 아직 논란의 여지가 있는 상태이다. 최근 저자들은 비폐색과 동반된 코골이 및 수면무호흡증 환자에서 비폐색과 수면무호흡증의 원인으로 생각되는 비중격 만곡증 및 비후성비염을 교정하기 위해 비중격 교정술 및 하비갑개 절제술을 시행한 결과 수술 전, 후의 증상 및 수면 다원검사 비교에서 뚜렷한 호전을 경험하였기에 보고하는 바이다.

  • PDF

실시간 얼굴 검출을 위한 Cascade CNN의 CPU-FPGA 구조 연구 (Cascade CNN with CPU-FPGA Architecture for Real-time Face Detection)

  • 남광민;정용진
    • 전기전자학회논문지
    • /
    • 제21권4호
    • /
    • pp.388-396
    • /
    • 2017
  • 얼굴 검출에는 다양한 포즈, 빛의 세기, 얼굴이 가려지는 현상 등의 많은 변수가 존재하므로, 높은 성능의 검출 시스템이 요구된다. 이에 영상 분류에 뛰어난 Convolutional Neural Network (CNN)이 적절하나, CNN의 많은 연산은 고성능 하드웨어 자원을 필요로한다. 그러나 얼굴 검출을 위한 소형, 모바일 시스템의 개발에는 저가의 저전력 환경이 필수적이고, 이를 위해 본 논문에서는 소형의 FPGA를 타겟으로, 얼굴 검출에 적절한 3-Stage Cascade CNN 구조를 기반으로하는 CPU-FPGA 통합 시스템을 설계 구현한다. 가속을 위해 알고리즘 단계에서 Adaptive Region of Interest (ROI)를 적용했으며, Adaptive ROI는 이전 프레임에 검출된 얼굴 영역 정보를 활용하여 CNN이 동작해야 할 횟수를 줄인다. CNN 연산 자체를 가속하기 위해서는 FPGA Accelerator를 이용한다. 가속기는 Bottleneck에 해당하는 Convolution 연산의 가속을 위해 FPGA 상에 다수의 FeatureMap을 한번에 읽어오고, Multiply-Accumulate (MAC) 연산을 병렬로 수행한다. 본 시스템은 Terasic사의 DE1-SoC 보드에서 ARM Cortex A-9와 Cyclone V FPGA를 이용하여 구현되었으며, HD ($1280{\times}720$)급 입력영상에 대해 30FPS로 실시간 동작하였다. CPU-FPGA 통합 시스템은 CPU만을 이용한 시스템 대비 8.5배의 전력 효율성을 보였다.

잔존치조제 형태 및 총의치 인공치 크기가 무치하악 응력발생에 미치는 영향에 관한 3차원적 광탄성응력분석 (THREE DIMENSIONAL PHOTOELASTIC ANALYSIS OF STRESS OF EDENTULOUS MANDIBULE ACCORDING TO VARIOUS RIDGE SHAPES AND ARTIFICIAL TEETH SIZES)

  • 최창덕;유광희
    • 대한치과보철학회지
    • /
    • 제30권3호
    • /
    • pp.457-478
    • /
    • 1992
  • Electrical resistance strain gauges, brittle-coatings, Moir'e fringe analysis, photoelasticity methods, etc, have been employed in the study of stress analysis and three-dimensional photoelasticity method used in this experiment. The author fabricated a total of 24 samples of maxillary and mandibular edentulous ridges with normal and sharp shapes using epoxy resin, one of the photoelastic materials. In addition, complete denture made from artificial resin teeth in other twoo sizes, large and medium size, were affixed to the specimens and attached to an articulator. The following results were attained by cutting 9 slice specimens into 6mm thick portions, in accordance with the three dimensional photoelastic stress freezing method, to analyze stress distribution status under specific static loading in the central, lateral and protrusive occlusions of the shape of edentulous ridge. 1. In the case of central occlusion, when complete resin artificial teeth in large and medium sizes were used on normal and sharp alveolar ridges, high stress distribution was broadly shown in the labio-buccal sides, and low and concentrated in the lingual sides, in all cases. Generally, the highest stresses were shown at the top of the alveolus, or at 2mm below the top of the alveolus, particularly in the specimen 2, 3, and stresses were more or less the same in the symmetrical right and left sides. 2. In the case of lateral occlusion, when the same load was applied, high stresses were shown broadly at the working sides in both the labio-buccal and lingual sides, and low and concentrated at the balanced sides. The highest stresses were shown in the top of the alveolus on the working sides in specimen 2 portion, and the lowest stresses at the balanced sides in specimen 6, slightly higher stresses were shown at retromolar parts in the balanced sides. 3. In the case of protrusive occlusion, high stresses were broadly shown at the labio-buccal sides, and slightly higher stresses at the top 2, 4, and 6mm parts of the alveolus with concentration. The highest stresses were shown in specimen No. 5 and the lowes stresses in specimen 1, 9 and stresses were more of less the same at the symmetrical right and left sides.

  • PDF

정맥 내 980-nm 다이오드 레이저를 이용한 대복재정맥 역류의 치료 (Endovenous 980-nm Diode Laser Treatment of Incompetent Great Saphenous Vein)

  • 김건일;조태준;이재웅;홍기우;이원용
    • Journal of Chest Surgery
    • /
    • 제40권2호
    • /
    • pp.97-102
    • /
    • 2007
  • 배경 : 최근 하지 정맥류 치료에 정맥 내 레이저 치료가 도입되어 비침습적이면서도 좋은 치료 결과들이 많이 보고되고 있다. 저자들은 대복재정맥 역류로 인한 하지 정맥류 환자에서 980-nm 다이오드레이저를 이용하여 대복재정맥 폐쇄술을 시행하였으며 그 치료 효과를 분석하였다. 대상 및 방법: 2003년 9월부터 2006년 2월까지 대복재정맥 역류로 인한 하지 정맥류 환자 238명(332예)을 대상으로 980-nm 다이오드 레이저를 이용하여 정맥 내 레이저 치료를 시행하였다. 수술은 레이저 치료와 동시에 보행적 정맥류 제거술을 시행하였다. 수술 전 임상 양상과 수술 합병증, 그리고 수술 후 1개월과 3개월의 추적 듀플렉스 초음파 검사 결과를 분석하였다. 결과 : 수술 후 합병증으로는 대부분의 환자에서 반상 출혈이 발생하였고, 감각 이상이 68예(20.5%), 피부화상이 3예(0.9%) 발생하였다. 추적 초음파 검사에서 수술 1개월 후 26예, 3개월 후에는 10예에서 추가로 대복재 정맥 역류 혹은 부분 혈류재개가 확인되어 치료성공률은 각각 91.3%, 87.9%였다. 결론: 레이저를 이용한 대복재정맥 폐쇄술이 기존의 대복재정맥 발거술에 비하여 비침습적이기는 하지만 저자들은 다소 높은 대복재정맥의 재개통을 경험하였다. 이는 적절치 않은 레이저 강도나 적용 시간(속도), 과도하게 확장된 대복재정맥 등이 원인일 것으로 생각되며 시술 후 정맥의 재개통을 줄이기 위한 많은 연구 노력과 함께 초음파 검사를 통한 정확한 추적 관찰이 필요할 것으로 생각한다.

적외선 카메라를 이용한 비제약적 환경에서의 얼굴 인증 (Face Identification Using a Near-Infrared Camera in a Nonrestrictive In-Vehicle Environment)

  • 기민송;최영우
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제10권3호
    • /
    • pp.99-108
    • /
    • 2021
  • 차량 내부에는 조명 변화, 부분적인 가림 및 운전자의 상태 변화와 같은 제한되지 않은 조건들이 존재한다. 본 논문에서는 비 제약적인 차량 환경에서의 운전자 얼굴 인증 시스템을 제안한다. 제안한 방법은 차량 내부 및 외부의 조명 변화에 따라 발생하는 얼굴 이미지의 변화를 최소화하기 위해서 근적외선(NIR) 카메라를 사용한다. 특히 정면에서의 강한 빛에 노출된 얼굴 이미지를 처리하기 위해서, 학습 이미지의 평균과 분산을 사용하여 정상적인 얼굴 이미지로부터 빛에 과다하게 노출된 이미지로 변환하여 사용한다. 따라서 정상적인 조명에서의 얼굴 분류기와 강한 정면광에서의 얼굴 분류기를 각각 동시에 만들어진다. 제안하는 얼굴 분류기는 얼굴 랜드마크를 추출하고 각 랜드마크의 신뢰도 점수를 합산하여 얼굴을 최종적으로 식별한다. 특히 각 랜드마크를 인식하여 부분적인 얼굴 가림에 강하기 때문에 안경이나 선글라스를 착용하는 상황에서도 높은 성능 향상이 가능하다. 즉 가려지지 않은 남은 랜드마크의 점수를 사용하여 운전자를 인식할 수 있다. 또한 등록 운전자와 미등록 운전자 간의 관계를 고려한 새로운 인식 거부 방법과 새로운 평가 방법을 논문에서 제안한다. 자체 취득한 데이터 셋, 공인된 PolyU 및 ORL 데이터 셋으로 실험한 결과 제안한 방법이 효과적임을 확인할 수 있었다.

Aspiration-Retriever Technique for Stroke with Large Bore Intermediate Catheter : A Single Center Experience

  • Nam, Ji Won;Jung, Na Young;Park, Eun Suk;Kwon, Soon Chan
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권5호
    • /
    • pp.732-739
    • /
    • 2021
  • Objective : Early successful reperfusion is associated with favorable outcomes in acute ischemic stroke (AIS). The purpose of this study was to achieve successful recanalization by a combined mechanical thrombectomy technique, the Aspiration-Retriever Technique for Stroke (ARTS), which is composed of a flexible large lumen distal access catheter and a retrievable stent as the first-line strategy of mechanical thrombectomy. Methods : We retrospectively reviewed 62 patients with AIS who underwent mechanical thrombectomy from 2018 to 2019 at our institute by a senior neurointerventionalist. Among them, patients who were treated using the ARTS technique with the soft torqueable catheter optimized for intracranial access (SOFIA®; MicroVention-Terumo, Tustin, CA, USA) as the first-line treatment were included. Patients who had tandem occlusions or underlying intracranial artery stenosis were excluded. The angiographic and clinical outcomes were evaluated. The angiographic outcome was analyzed by the rate of successful recanalization, defined as a Thrombolysis in Cerebral Infarction score of 2b or 3 at the end of all procedures and the rate of successfully achieving the first pass effect (FPE), defined as complete recanalization with a single pass of the device. The clinical outcomes included the National Institutes of Health Stroke Scale (NIHSS) score, modified Rankin Scale (mRS), and mortality. Results : A total of 27 patients (mean age, 59.3 years) fulfilled the inclusion criteria. The successful recanalization rate was 96% (n=26) while the FPE rate was 41% (n=11). The mean post-procedural NIHSS change was -3.0. Thirteen patients (48%) showed good clinical outcomes after thrombectomy with the ARTS technique (mRS at 90 days ≤2). Postoperative complications occurred in seven of 25 patients : hemorrhagic transformation in six patients (22%) and distal embolization in one patient (4%). Mortality was 15% (n=4). Conclusion : Although the clinical outcomes using the ARTS technique with a flexible large lumen distal access catheter performed as the frontline thrombectomy in patients with AIS were not significantly superior than those of other studies, this study showed a high rate of successful endovascular recanalization which was comparable to that of other studies. Therefore, ARTS using the SOFIA® catheter can be considered as the first choice of treatment for AIS due to large vessel occlusion.

UKF와 연동된 입자필터를 이용한 실시간 단안시 카메라 추적 기법 (Real-time Monocular Camera Pose Estimation using a Particle Filiter Intergrated with UKF)

  • 이석한
    • 한국정보전자통신기술학회논문지
    • /
    • 제16권5호
    • /
    • pp.315-324
    • /
    • 2023
  • 본 논문에서는 UKF(unscented Kalman filter)와 연동된 입자필터를 이용한 단안시 카메라의 실시간 자세추정 기법을 제안한다. 단안시 카메라 자세 추정 기법에는 주로 카메라 영상과 자이로스코프, 가속도센서 데이터 등을 연동하는 방법이 많이 이용되고 있으나 본 논문에서 제안하는 방법은 별도의 센서 없이 카메라 영상에서 취득되는 2차원 시각 정보만을 이용하는 것을 목표로 한다. 제안된 방법은 카메라 영상 이외의 부가적인 장비를 이용하지 않고 별도의 센싱 정보 없이 2차원 영상만으로 카메라 추적이 가능하며, 따라서 기존에 비해 하드웨어 구성이 단순해질수 있다는 장점을 갖고 있다. 제안된 방법은 UKF와 연동된 입자필터를 기반으로 한다. 입자필터의 각 입자마다 개별적으로 정의된 UKF로부터 카메라의 상태를 추정한 다음 입자필터의 전체 입자로부터 카메라 상태에 대한 통계데이터를 산출하고 이로부터 카메라의 실시간 자세정보를 계산한다. 기존의 방법과 달리 제안된 방법은 카메라의 급격한 흔들림이 발생하는 경우에도 카메라 추적이 가능함을 보여주며, 영상 내의 특징점 대다수가 가려지는 환경에서도 카메라 추적에 실패하지 않음을 실험을 통하여 확인하였다. 또한 입자의 개수가 35개인 경우 프레임 당 소요 시간이 약 25ms이며 이로부터 실시간 처리에 문제가 없음을 확인할 수 있었다.

Safety and Effectiveness of Passeo-18 Lux Drug-Coated Balloon Catheter in Infrainguinal Endovascular Revascularization in the Korean Population: A Multicenter Post-Market Surveillance Study

  • Tae Won Choi;Je Hwan Won;Hwan Jun Jae;Yong Sun Jeon;Sang Woo Park;Gi-Young Ko;Nam Yeol Yim;Jong Yun Won;Chang Won Kim;Jinoo Kim
    • Korean Journal of Radiology
    • /
    • 제25권6호
    • /
    • pp.565-574
    • /
    • 2024
  • Objective: To evaluate the safety and clinical outcomes of the Passeo-18 Lux drug-coated balloon (DCB) in endovascular revascularization procedures under real-world conditions in a Korean population with atherosclerotic disease of the infrainguinal arteries, including below-the-knee (BTK) arteries. Materials and Methods: Eight institutions in the Republic of Korea participated in this prospective, multicenter, single-arm, post-market surveillance study. Two hundred patients with Rutherford class 2-5 peripheral arterial disease and infrainguinal lesions suitable for endovascular treatment were competitively enrolled. Data were collected at baseline, the time of intervention, discharge, and 1-, 6-, 12-, and 24-month follow-up visits. The primary safety endpoint was freedom from major adverse events (MAE) within 6 months (except when limiting the time frame for procedure- or device-related mortality to within 30 days), and the primary effectiveness endpoint was freedom from clinically driven target lesion revascularization (CD-TLR) within 12 months after the procedure. Results: A total of 197 patients with 332 target lesions were analyzed. Two-thirds of the patients had diabetes mellitus, and 41.6% had chronic limb-threatening ischemia. The median target lesion length was 100 mm (interquartile range: 56-133 mm). Of the target lesions, 35.2% were occlusions, and 14.8% were located in the BTK arteries. Rate of freedom from MAE was 97.9% at 6 months, and the rate of freedom from CD-TLR was 95.0% and 92.2% at 12 and 24 months, respectively. Subgroup analysis of 43 patients and 49 target lesions involving the BTK arteries showed rate of freedom from MAE of 92.8% at 6 months and rates of freedom from CD-TLR of 88.8% and 84.4% at 12 and 24 months, respectively. Conclusion: The results of the present study, including the BTK subgroup analysis, showed outcomes comparable to those of other DCB studies, confirming the safety and effectiveness of Passeo-18 Lux DCB in the Korean population.

Feasibility of Single-Shot Whole Thoracic Time-Resolved MR Angiography to Evaluate Patients with Multiple Pulmonary Arteriovenous Malformations

  • Jihoon Hong;Sang Yub Lee;Jae-Kwang Lim;Jongmin Lee;Jongmin Park;Jung Guen Cha;Hui Joong Lee;Donghyeon Kim
    • Korean Journal of Radiology
    • /
    • 제23권8호
    • /
    • pp.794-802
    • /
    • 2022
  • Objective: To evaluate the feasibility of single-shot whole thoracic time-resolved MR angiography (TR-MRA) to identify the feeding arteries of pulmonary arteriovenous malformations (PAVMs) and reperfusion of the lesion after embolization in patients with multiple PAVMs. Materials and Methods: Nine patients (8 females and 1 male; age range, 23-65 years) with a total of 62 PAVMs who underwent percutaneous embolization for multiple PAVMs and were subsequently followed up using TR-MRA and CT obtained within 6 months from each other were retrospectively reviewed. All imaging analyses were performed by two independent readers blinded to clinical information. The visibility of the feeding arteries on maximum intensity projection (MIP) reconstruction and multiplanar reconstruction (MPR) TR-MRA images was evaluated by comparing them to CT as a reference. The accuracy of TR-MRA for diagnosing reperfusion of the PAVM after embolization was assessed in a subgroup with angiographic confirmation. The reliability between the readers in interpreting the TR-MRA results was analyzed using kappa (κ) statistics. Results: Feeding arteries were visible on the original MIP images of TR-MRA in 82.3% (51/62) and 85.5% (53/62) of readers 1 and 2, respectively. Using the MPR, the rates increased to 93.5% (58/62) and 95.2% (59/62), respectively (κ = 0.760 and 0.792, respectively). Factors for invisibility were the course of feeding arteries in the anteroposterior plane, proximity to large enhancing vessels, adjacency to the chest wall, pulsation of the heart, and small feeding arteries. Thirty-seven PAVMs in five patients had angiographic confirmation of reperfusion status after embolization (32 occlusions and 5 reperfusions). TR-MRA showed 100% (5/5) sensitivity and 100% (32/32, including three cases in which the feeding arteries were not visible on TR-MRA) specificity for both readers. Conclusion: Single-shot whole thoracic TR-MRA with MPR showed good visibility of the feeding arteries of PAVMs and high accuracy in diagnosing reperfusion after embolization. Single-shot whole thoracic TR-MRA may be a feasible method for the follow-up of patients with multiple PAVMs.