Aspiration-Retriever Technique for Stroke with Large Bore Intermediate Catheter : A Single Center Experience

  • Nam, Ji Won (Department of Neurological Surgery, Ulsan University Hospital, University of Ulsan College of Medicine) ;
  • Jung, Na Young (Department of Neurological Surgery, Ulsan University Hospital, University of Ulsan College of Medicine) ;
  • Park, Eun Suk (Department of Neurological Surgery, Ulsan University Hospital, University of Ulsan College of Medicine) ;
  • Kwon, Soon Chan (Department of Neurological Surgery, Ulsan University Hospital, University of Ulsan College of Medicine)
  • Received : 2020.10.29
  • Accepted : 2021.03.26
  • Published : 2021.09.01

Abstract

Objective : Early successful reperfusion is associated with favorable outcomes in acute ischemic stroke (AIS). The purpose of this study was to achieve successful recanalization by a combined mechanical thrombectomy technique, the Aspiration-Retriever Technique for Stroke (ARTS), which is composed of a flexible large lumen distal access catheter and a retrievable stent as the first-line strategy of mechanical thrombectomy. Methods : We retrospectively reviewed 62 patients with AIS who underwent mechanical thrombectomy from 2018 to 2019 at our institute by a senior neurointerventionalist. Among them, patients who were treated using the ARTS technique with the soft torqueable catheter optimized for intracranial access (SOFIA®; MicroVention-Terumo, Tustin, CA, USA) as the first-line treatment were included. Patients who had tandem occlusions or underlying intracranial artery stenosis were excluded. The angiographic and clinical outcomes were evaluated. The angiographic outcome was analyzed by the rate of successful recanalization, defined as a Thrombolysis in Cerebral Infarction score of 2b or 3 at the end of all procedures and the rate of successfully achieving the first pass effect (FPE), defined as complete recanalization with a single pass of the device. The clinical outcomes included the National Institutes of Health Stroke Scale (NIHSS) score, modified Rankin Scale (mRS), and mortality. Results : A total of 27 patients (mean age, 59.3 years) fulfilled the inclusion criteria. The successful recanalization rate was 96% (n=26) while the FPE rate was 41% (n=11). The mean post-procedural NIHSS change was -3.0. Thirteen patients (48%) showed good clinical outcomes after thrombectomy with the ARTS technique (mRS at 90 days ≤2). Postoperative complications occurred in seven of 25 patients : hemorrhagic transformation in six patients (22%) and distal embolization in one patient (4%). Mortality was 15% (n=4). Conclusion : Although the clinical outcomes using the ARTS technique with a flexible large lumen distal access catheter performed as the frontline thrombectomy in patients with AIS were not significantly superior than those of other studies, this study showed a high rate of successful endovascular recanalization which was comparable to that of other studies. Therefore, ARTS using the SOFIA® catheter can be considered as the first choice of treatment for AIS due to large vessel occlusion.

Keywords

References

  1. Berkhemer OA, Fransen PS, Beumer D, van den Berg LA, Lingsma HF, Yoo AJ, et al. : A randomized trial of intraarterial treatment for acute ischemic stroke. N Engl J Med 372 : 11-20, 2015 https://doi.org/10.1056/NEJMoa1411587
  2. Brinjikji W, Raz E, De Leacy R, Meila D, Mokin M, Samaniego EA, et al. : MRS SOFIA: a multicenter retrospective study for use of Sofia for revascularization of acute ischemic stroke. J Neurointerv Surg, 2021 [Epub ahead of print]
  3. Campbell BC, Mitchell PJ, Kleinig TJ, Dewey HM, Churilov L, Yassi N, et al. : Endovascular therapy for ischemic stroke with perfusion-imaging selection. N Engl J Med 372 : 1009-1018, 2015 https://doi.org/10.1056/NEJMoa1414792
  4. Delgado Almandoz JE, Kayan Y, Young ML, Fease JL, Scholz JM, Milner AM, et al. : Comparison of clinical outcomes in patients with acute ischemic strokes treated with mechanical thrombectomy using either Solumbra or ADAPT techniques. J Neurointerv Surg 8 : 1123-1128, 2016 https://doi.org/10.1136/neurintsurg-2015-012122
  5. Deng L, Qiu S, Wang L, Li Y, Wang D, Liu M : Comparison of four food and drug administration-approved mechanical thrombectomy devices for acute ischemic stroke: a network meta-analysis. World Neurosurg 127 : e49-e57, 2019 https://doi.org/10.1016/j.wneu.2019.02.011
  6. Goyal M, Demchuk AM, Menon BK, Eesa M, Rempel JL, Thornton J, et al. : Randomized assessment of rapid endovascular treatment of ischemic stroke. N Engl J Med 372 : 1019-1030, 2015 https://doi.org/10.1056/NEJMoa1414905
  7. Hesse AC, Behme D, Kemmling A, Zapf A, Grosse Hokamp N, Frischmuth I, et al. : Comparing different thrombectomy techniques in five largevolume centers: a 'real world' observational study. J Neurointerv Surg 10 : 525-529, 2018 https://doi.org/10.1136/neurintsurg-2017-013394
  8. Kim YW, Hwang YH, Kim YS, Kang DH : Frontline contact aspiration thrombectomy using SOFIA catheter for acute ischemic stroke: periodto-period comparison with Penumbra catheter. Acta Neurochir (Wien) 161 : 1197-1204, 2019 https://doi.org/10.1007/s00701-019-03914-4
  9. Lapergue B, Blanc R, Gory B, Labreuche J, Duhamel A, Marnat G, et al. : Effect of endovascular contact aspiration vs stent retriever on revascularization in patients with acute ischemic stroke and large vessel occlusion: the ASTER randomized clinical trial. JAMA 318 : 443-452, 2017 https://doi.org/10.1001/jama.2017.9644
  10. Linfante I, Walker GR, Castonguay AC, Dabus G, Starosciak AK, Yoo AJ, et al. : Predictors of mortality in acute ischemic stroke intervention: analysis of the North American solitaire acute stroke registry. Stroke 46 : 2305-2308, 2015 https://doi.org/10.1161/STROKEAHA.115.009530
  11. Long TD, Kallmes DF, Hanel R, Shigematsu T, Halaszyn AM, Wolter J, et al. : Novel aspiration catheter design for acute stroke thrombectomy. J Neurointerv Surg 11 : 190-195, 2019 https://doi.org/10.1136/neurintsurg-2017-013702
  12. Marnat G, Barreau X, Detraz L, Bourcier R, Gory B, Sgreccia A, et al. : First-line sofia aspiration thrombectomy approach within the endovascular treatment of ischemic stroke multicentric registry: efficacy, safety, and predictive factors of success. AJNR Am J Neuroradiol 40 : 1006-1012, 2019 https://doi.org/10.3174/ajnr.A6074
  13. Massari F, Henninger N, Lozano JD, Patel A, Kuhn AL, Howk M, et al. : ARTS (aspiration-retriever technique for stroke): initial clinical experience. Interv Neuroradiol 22 : 325-332, 2016 https://doi.org/10.1177/1591019916632369
  14. Mohlenbruch MA, Kabbasch C, Kowoll A, Broussalis E, Sonnberger M, Muller M, et al. : Multicenter experience with the new SOFIA plus catheter as a primary local aspiration catheter for acute stroke thrombectomy. J Neurointerv Surg 9 : 1223-1227, 2017 https://doi.org/10.1136/neurintsurg-2016-012812
  15. Nouri N, Ferrigno M, Personnic T, Bala F, Bretzner M, Estrade L, et al. : Real-world thrombectomy using the sofia catheter. World Neurosurg 122 : e1247-e1251, 2019 https://doi.org/10.1016/j.wneu.2018.11.023
  16. Powers WJ, Rabinstein AA, Ackerson T, Adeoye OM, Bambakidis NC, Becker K, et al. : Guidelines for the farly management of patients with acute ischemic stroke: 2019 update to the 2018 guidelines for the early management of acute ischemic stroke: a guideline for healthcare professionals from the American Heart Association/American Stroke Association. Stroke 50 : e344-e418, 2019
  17. Rennert RC, Wali AR, Steinberg JA, Santiago-Dieppa DR, Olson SE, Pannell JS, et al. : Epidemiology, natural history, and clinical presentation of large vessel ischemic stroke. Neurosurgery 85 : S4-S8, 2019
  18. Rha JH, Saver JL : The impact of recanalization on ischemic stroke outcome: a meta-analysis. Stroke 38 : 967-973, 2007 https://doi.org/10.1161/01.STR.0000258112.14918.24
  19. Saver JL : Time is brain--quantified. Stroke 37 : 263-266, 2006 https://doi.org/10.1161/01.STR.0000196957.55928.ab
  20. Saver JL, Jahan R, Levy EI, Jovin TG, Baxter B, Nogueira RG, et al. : Solitaire flow restoration device versus the merci retriever in patients with acute ischaemic stroke (SWIFT): a randomised, parallel-group, noninferiority trial. Lancet 380 : 1241-1249, 2012 https://doi.org/10.1016/S0140-6736(12)61384-1
  21. Saver JL, Goyal M, Bonafe A, Diener HC, Levy EI, Pereira VM, et al. : Stent-retriever thrombectomy after intravenous t-PA vs. t-PA alone in stroke. N Engl J Med 372 : 2285-2295, 2015 https://doi.org/10.1056/NEJMoa1415061
  22. Shallwani H, Shakir HJ, Rangel-Castilla L, Davies JM, Sonig A, Sattur MG, et al. : Safety and efficacy of the sofia (6F) PLUS distal access reperfusion catheter in the endovascular treatment of acute ischemic stroke. Neurosurgery 82 : 312-321, 2018 https://doi.org/10.1093/neuros/nyx169
  23. Stampfl S, Kabbasch C, Muller M, Mpotsaris A, Brockmann M, Liebig T, et al. : Initial experience with a new distal intermediate and aspiration catheter in the treatment of acute ischemic stroke: clinical safety and efficacy. J Neurointerv Surg 8 : 714-718, 2016 https://doi.org/10.1136/neurintsurg-2015-011801
  24. Turk AS, Frei D, Fiorella D, Mocco J, Baxter B, Siddiqui A, et al. : ADAPT FAST study: a direct aspiration first pass technique for acute stroke thrombectomy. J Neurointerv Surg 6 : 260-264, 2014 https://doi.org/10.1136/neurintsurg-2014-011125
  25. Wardlaw JM, Murray V, Berge E, del Zoppo G, Sandercock P, Lindley RL, et al. : Recombinant tissue plasminogen activator for acute ischaemic stroke: an updated systematic review and meta-analysis. Lancet 379 : 2364-2372, 2012 https://doi.org/10.1016/S0140-6736(12)60738-7
  26. Wong JHY, Do HM, Telischak NA, Moraff AM, Dodd RL, Marks MP, et al. : Initial experience with SOFIA as an intermediate catheter in mechanical thrombectomy for acute ischemic stroke. J Neurointerv Surg 9 : 1103-1106, 2017 https://doi.org/10.1136/neurintsurg-2016-012750
  27. Writing Group Members, Mozaffarian D, Benjamin EJ, Go AS, Arnett DK, Blaha MJ, et al. : Executive summary: heart disease and stroke statistics--2016 update: a report from the American Heart Association. Circulation 133 : 447-454, 2016 https://doi.org/10.1161/CIR.0000000000000366
  28. Zaidat OO, Castonguay AC, Linfante I, Gupta R, Martin CO, Holloway WE, et al. : First pass effect: a new measure for stroke thrombectomy devices. Stroke 49 : 660-666, 2018 https://doi.org/10.1161/STROKEAHA.117.020315