• Title/Summary/Keyword: Occlusion type

Search Result 291, Processing Time 0.032 seconds

Clinical Study about Warning Signs of Patients with Acute Stroke (급성기(急性期) 중풍환자(中風患者)에 대한 중풍전조증(中風前兆症) 조묘(調杳) 연구(硏究))

  • Jung, Jae-Han;Sun, Jong-Joo;Choi, Chang-Min;Kim, Seok-Min;Kim, Chang-Hyun;Min, In-Gyu;Jeong, Dong-Won;Park, Sung-Uk;Jung, Woo-sang;Moon, Sang-Kwan;Park, Jung-Mi;Ko, Chang-Nam;Kim, Young-Suk;Bae, Hyung-Sup;Cho, Ki-Ho
    • The Journal of Internal Korean Medicine
    • /
    • v.28 no.1
    • /
    • pp.47-67
    • /
    • 2007
  • Objectives : This study was aimed to investigated the warning signs and its relationship with the other characteristics in acute stroke patients. Methods : 225 acute stroke patients were recruited at the Department of Cardiovascular and Neurologic Diseases (Stroke Center) of Kyung Hee University Oriental Hospital from October 2005 to September 2006. We evaluated their stroke type with brain MRI, their warning signs, and general characteristics such as age, sex, past history, risk factors, etc. Results : 225 subjects were included in the final analysis. In the subjects' general characteristics, the most common etiology of stroke was small vessel occlusion. In the assessment of the subjects' warning signs, the frequency of tension felt at the cervical area was highest followed by blepharospasm, sensory dysfunction (one side of numbness, tingling sensation, dead sensation), one side paralysis or weakness, etc. After analyzing etiology, cerebral hemorrhage had more facial spasm sign and hypertension than cerebral infarction. On the other hand, cerebral infarction had more diabetes and sensory dysfunction (one side of numbness, tingling sensation, dead sensation) than cerebral hemorrhage. Among stroke locations, subjects with their brain lesion in the cortex had more warning sings of motor dysfunction such as one side paralysis, or weakness. Multiple lesions showed a close relationship with smoking habit and were more common in males than in females. The under 65 years old group were more commonly associated with alcohol consumption, accidental mental stress and blepharospam than the over 65 years old group. In the group of under 65 years old, males more commonly had lesions in occipital lobe, alcohol consumption and smoking habit than females. Otherwise, females more commonly had vision dysfunction and blepharospasm than males. In the group of over 65 years old, males more commonly had cortex lesion than females. On the other hand, Females more commonly had accidental mental stress than males. Conclusions : We observed various warning signs and their distribution in acute stroke patients. The subjects' brainlesions and their etiology seemed to affect the features of the warning signs. Hypertension, diabetes and hyperlipidemia were also related to etiology of stroke and some habitual problems such as smoking and drinking seemed to reduce the age of stroke ictus. Although a concrete conclusion can hardly be drawn from this study, it reminds physicians of the importance of warning signs which appear among their patients.

  • PDF

The Comparison of the Retention of the Full Veneer Casted Gold Crowns with Different Implant Abutment Shapes and Types of Cements (임플란트 지대주 형태와 시멘트 종류에 따른 전부주조금관의 유지력 비교)

  • Jung, Jae-Wook;Kim, Jee-hwan;Kim, Sun-jai;Moon, Hong-suk;Shim, June-sung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.403-415
    • /
    • 2009
  • The purpose of the study is to establish the effect of different abutment shapes and types of cements on the retention of the full veneer casted gold crowns. Metal dies that has the similar shape with the implant abutment were manufactured using a short(5mm) and long(10mm) dies with different convergence angles. Metal dies and gold crowns, which were made from the metal dies, were cemented with Temp-bond, Temp-bond mixed with petroleum jelly, ZPC and Premier implant cement. After that, these were tested for tensile force at the point of separation. The effect of convergence angle changes of different cement types on the retention was studied as well as the effects of the cement type changes with different convergence angles on the retention. In addition, study about the marginal gap of Premier implant cement used for this experiment was conducted. The results are as followed under the in-vitro experimental limits; 1. The retention of the Temp-bond mixed with petroleum jelly decreased as the convergence angle increased, and the retention was weakest among the cements. 2. The retention of ZPC decreased as convergence angle increased. When convergence angle was 5 degrees, ZPC showed stronger retention than Premier implant cement. 3. Premier implant cement had the weakest retention when the convergence angle was 5 degrees but when the convergence angle was 10 degrees, it had the strongest retention. As the angle increased more than 10 degrees, the retention decreased. 4. Premier implant cement showed bigger marginal gap when the convergence angle was 5 degrees than 10 degrees under the experimental condition.

Analysis of Effect and Prognostic Factors Associated with Catheter Intervention on Ascites in Terminal Cancer Patient (복수가 있는 말기 암환자에서 복수 배액관 시술의 효과와 예후요인 분석)

  • Jang, Mungsun;Kim, Chul-Min;Yoon, Johi;Nah, Jung-Ran;Chang, Seung-Nam;Kim, Myung Ok;Lee, Ja Young
    • Journal of Hospice and Palliative Care
    • /
    • v.19 no.4
    • /
    • pp.303-309
    • /
    • 2016
  • Purpose: Malignant ascites is a common complication in terminal cancer patients. Less-invasive pigtail catheter insertion is the most frequent procedure in patients who need repeated ascites drainage. This study investigated effects and adverse events associated with catheter insertion for ascites drainage and evaluated prognostic outcomes. Methods: We reviewed medical records between 2010 and 2013 of hospice and palliative care institutions in Seoul, South Korea. Among 2,608 inpatients, 67 patients received ascites pigtail catheter drainage. We reviewed demographic data, palliative performance scale, laboratory data, duration of catheter insertion, prevalence and type of complications, use and duration of antibiotics, and survival time. Univariate and multivariate Cox regression models were used to evaluate prognostic outcomes related with catheter insertion. Results: Ascites drainage was performed most commonly in hepatobiliary and gastric cancer patients. Ascites symptoms improved in 55 patients after the catheter drainage. Adverse events included pain (19.4%), leakage (14.9%), disconnection (7.5%), catheter occlusion (6%) and fever (4.5%). In Cox regression analysis, survival time from the catheter insertion was significantly associated with Palliative Performance Scale (PPS) (HR 0.73; P value 0.045) and serum sodium level (HR 2.77; P value 0.003) in a multivariate model. Conclusion: Patients' PPS and serum sodium level should be considered before making a decision of pigtail catheter insertion.

A Study of the Comparison of Microleakage according to the Types of Cement on the Cast Post and Core (주조 포스트코아에서 시멘트 종류가 미세누출에 미치는 영향)

  • Nam, Ki-Young;Lee, Cheong-Hee;Cho, Kwang-Hyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.1
    • /
    • pp.51-60
    • /
    • 2000
  • The purpose of this study was to compare the microleakage at the interface of cast post and tooth according to the type of cement. Forty anterior teeth with single root were used. The teeth were cut 2 mm coronal from the cementoeamel junction and chamfer finish line was made on 1 mm coronal from the cementoeamel junction. After the routine endodontic treatment, post space was prepared using #5.5 Parapost drill to a depth of 7 mm. After the pick up impression, core building was made to 3 mm of clinical crown with burnout wax, then post and core was cast with nonprecious metal. The teeth were divided into four groups of ten each. In Group I, post and core were cemented with Fleck's(Zinc phosphate cement) In Group II, post and core were cemented with Fuji I(Glass ionomer cement) In Group III, post and core were cemented with Superbond C & B(Composite resin cement) In Group IV, post and core were cemented with Panavia 21(Composite resin cement) All cemented teeth were stored in normal saline at $37^{\circ}C$ for 7 days and thermocycled from $5^{\circ}C$ to $55^{\circ}C$ for 500 cycles with a dwell time of 30 seconds. After thermocycling, teeth were immersed in 1% Basic fuchsin dye for 48 hours. All 40 teeth were then embedded in the epoxy resin and cut buccolingually with a cutting instrument. The degree of penetration of dye at interface was graded on a scale of 0 to 4 using a stereomicroscope at 25 to 40 times magnification. Through the findings of this study, the following conclusion were obtained. 1. All the groups showed the microleakage at the interface of cast post core and tooth. 2. Group I showed the highest microleakage score among the groups with a significant difference(p<0.05). 3. Group II showed higher microleakage score than Group III and Group IV with a significant difference(p<0.05). 4. Group IV showed the lowest microleakage score but there were no significant difference with Group III(p>0.05).

  • PDF

Retention of CAD/CAM Metal Copings Cemented on Short Titanium Abutments with Different Cements (짧은 티타늄 지대주에 합착된 CAD/CAM 금속 코핑의 시멘트 종류에 따른 유지력 비교)

  • Kim, Hyo-Jung;Song, Eun-Young;Yoon, Ji-Young;Lee, Si-Ho;Lee, Yong-Keun;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.119-126
    • /
    • 2012
  • State of problem: Cement-retained implant-supported prostheses are routinely used in dentistry. The use of high strength cements has become more popular with the increasing confidence in the stability of the implant-abutment screw connection and the high survival rates of osseointegrated implants. No clinical data on retention of metal copings using CAD/CAM. To evaluate retention of metal copings using CAD/CAM system bonded to short titanium abutment with four different cements and compare retentive strength of metal copings with sandblasting or without sandblasting before cementation. Forty titanium abutment blocks were fabricated and divided into 4 groups of 10 samples each. Forty metal copings with occlusal hole to allow for retention testing were fabricated using CAD/CAM technology. The four cements were Fujicem(Fuji, Japan), Maxcem Elite(Kerr, USA), Panavia F2.0(Kurarary, Japan) and Superbond C&B(Sunmedical, Japan). The copings were cemented on the titanium abutment according to manufacture's recommendation. All samples were stored for 24h at 37oC in 100% humidity and tested for retention using universal testing machine(Instron) at a crosshead speed of 1.0mm/min. Force at retentive failure was recorded in Newton. The mode of failure was also recorded. Means and standard deviations of loads at failure were analyzed using ANOVA and Paired t-test. Statistical significance was set at P<0.05. Panavia F2.0 provided significantly higher retentive strength than Fujicem, Maxcem Elite(P<0.05). Sandblasting significantly increased bond strength(P<0.05). The mode of failure was cement remaining principally on metal copings. Within the limitation of this study, Panavia F2.0 showed significantly stronger retentive strength than Fujicem, Maxcem Elite(p<0.05). The Ranking order of the cements to retain the copings was Panavia F2.0, Fujicem = Maxcem Elite. Sandblasting significantly increased bond strength(P<0.05). The retentive strength of metal copings on implant abutment were influenced by surface roughness and type of cements.

A Study on the Status of Recognition and Practical Application of Oral Hygiene Devices : with outpatient as the central figure (치과병·의원 내원환자의 구강위생용품에 대한 인지도 및 사용실태에 관한 연구)

  • Kim, Soo-Kyung
    • Journal of dental hygiene science
    • /
    • v.2 no.2
    • /
    • pp.95-103
    • /
    • 2002
  • This study was carried out to investigate recognition level and practical application status of oral hygiene devices through making a survey of Seoul inhabitants. And survey was implemented in order to propose oral hygiene device for household health care activities. The following results were obtained by analyzing personal interviews of 347 commuting patients at two university hospitals and seven dental clinics. 1) The average length of toothbrush head was estimated as 22.3 mm and average changing cycle was 2.3 months. The user ratio of flat-headed brush was estimated as 51.9% and 46.7% were using fluoridated toothpaste. 2) Generally the ratio of toothpick users was higher than other device users. But the user ratio of dental floss was higher than toothpick in case of patients under orthodontic treatment. 3) The patients under orthodontic treatment were not familiar with handling orthodontic toothbrush. Though 45.8% among orthodontic patients recognized this type of toothbrush, only 25.4% of them knew how exactly to use it. 4) It was shown very low user ratio of oral hygiene devices that the patients who had periodontal problem, hypersensitive trouble, halitosis, implant or denture 5) The patients who had halitosis showed the highest user ratio of toothpick. The patients who had separation of teeth showed the highest user ratio of dental floss. The patients who're under orthodontic treatment showed the highest user ratio of interproximal brush and motorized brush. 6) In response to the most interesting dental disease, it's surveyed as follows; 60.3% of dental caries, 24.0% of periodontal disease, 14.8% of false occlusion and 0.9% of oral cancer. 7) Regarding the motivation of using those oral hygiene devices, 45% responded that it was because of recommendation by dental clinics. Among the negative answers, 38.6% responded that it was because of no selection guidance. 31.3% answered that they didn't use hygiene device because it's inconvenient. 12.0% answered that it's difficult to buy and expensive. 7.8% responded that they didn't feel significant improvement. 4.8% answered that dental hospitals and clinics didn't even introduce those hygiene devices. Therefore efficient campaign for those hygiene devices over all Korea nation should be developed and education program must be prepared for each case of patients in every dental hospitals and clinics.

  • PDF

Deviations of Implant Position between Pre- and Post-operation in Computer-guided Template-based Implant Placement (Computer-guided template를 이용한 임플란트 식립에서 술 전과 술 후 사이의 임플란트 위치에 따른 변위량 검사)

  • Kim, Won;Kim, Seung-Mi;Kim, Hyo-Jung;Song, Eun-Young;Lee, Si-Ho;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.175-184
    • /
    • 2011
  • With a development of implant restoration technique, there are increasing use of computer-guided system for edentulous patients. It was carried out simulated operation based on CT information about patient's bone quantity, quality and anatomical landmark. However, there are some difference between the programmed implant and post-operative implant about it's position. If the deviation was severe, it could happen a failure of 'passive fit' and not suited for path of implant restoration. The aim of this presentation is to evaluate about a degree of deviations between programmed implant and post-operative implant. Five patients treated by 'NobelGuide' system (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden) in Department of Prosthodontics, Inha University were included in this study. The patients were performed CT radiograph taking and intra-oral impression taking at pre-operation. Based on CT images and study model, surgical stent was produced by NobelBiocareTM. To fabricated a pre-operative study model, after connected lab analog to surgical template, accomplished a pre-operative model using type 4 dental stone. At final impression, a post-operative study model was fabricated in the conventional procedures. Each study model was performed CT radiograph taking. Based on CT images, each implant was simulated in three dimensional position using $Procera^{(R)}$ software (Procera Software Clinical Design Premium, version 1.5; Nobel Biocare AB). In 3D simulated model, length and angulation between each implant of both pre- and post-operative implants were measured and recorded about linear and angular deviation between pre-and post-operative implants. A total of 24 implants were included in this study and 58 inter-implant sites between each implant were measured about linear and angular deviations. In the linear deviation a mean deviation of 0.41 mm (range 0~1.7 mm) was reported. In the angular deviation, a mean deviation was $1.99^{\circ}$ (range $0^{\circ}{\sim}6.7^{\circ}$). It appears that the both linear and angular mean deviation value were well acceptable to application of computer-guided implant system.

Marginal and internal fit of interim crowns fabricated with 3D printing and milling method (3D 프린팅 및 밀링 방법으로 제작된 임시 보철물 적합도 비교 분석)

  • Son, Young-Tak;Son, KeunBaDa;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.254-261
    • /
    • 2020
  • Purpose: The purpose of this study was to assess the marginal and internal fit of interim crowns fabricated by two different manufacturing method (subtractive manufacturing technology and additive manufacturing technology). Materials and Methods: Forty study models were fabricated with plasters by making an impression of a master model of the maxillary right first molar for ceramic crown. On each study model, interim crowns (n = 40) were fabricated using three types of 3D printers (Meg-printer 2; Megagen, Zenith U; Dentis, and Zenith D; Dentis) and one type milling machine (imes-icore 450i; imes-icore GmbH). The internal of the interim crowns were filled with silicon and fitted to the study model. Internal scan data was obtained using an intraoral scanner. The fit of interim crowns were evaluated in the margin, absolute margin, axial, cusp, and occlusal area by using the superimposition of 3D scan data (Geomagic control X; 3D Systems). The Kruskal-wallis test, Mann-Whitney U test and Bonferroni correction method were used to compare the results among groups (α = 0.05). Results: There was no significant difference in the absolute marginal discrepancy of the temporary crown manufactured by three 3D printers and one milling machine (P = 0.812). There was a significant difference between the milling machine and the 3D printer in the axial and occlusal area (P < 0.001). The temporary crown with the milling machine showed smaller axial gap and higher occlusal gap than 3D printer. Conclusion: Since the marginal fit of the temporary crown produced by three types of 3D printers were all with in clinically acceptable range (< 120 ㎛), it can be sufficiently used for the fabrication of the temporary crown.

Comparison of capsule type resin modified glass ionomer porosity according to mixing methods (혼합방법에 따른 캡슐형 광중합글라스아이노머의 공극률 비교)

  • Kim, Jung-min;Kim, Jin-Woo;Cho, Kyung-Mo;Lee, Yoon;Kim, Eung-Hyun;Park, Se-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.4
    • /
    • pp.217-224
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the porosity of resin modified glass ionomer (RMGI) by different mixing methods. Materials and Methods: Five specimens were prepared for each groups according to capsules and mixing methods. Two RMGI capsule and two mixing machines were used for this study. One resin-modified glass ionomer cement is Fuji II LC (F2LC) and the other is Photac Fil Quick Aplicap (PFQ). For Mixing of RMGI capsule, Rotomix using rotating motion and CM-II using shaking motion were used. After measuring height, radius and mass of specimens, Density was calculated. And porosity was measured using micro-computed tomography (micro-CT). All data were statistically analyzed using T-test, two-way ANOVA to compare between groups at 95% significance level to evaluate the affect of capsule and mixing method on the porosity. Results: The porosity was observed in all specimens generally. And there is significant differece between porosities according to RMGI capsule and Mixing method. The porosity of PFQ was lower than that of F2LC and the porosity of Rotomix was lower than that of CM-II. Conclusion: There was a difference of porosity according to kind of capsules and mixing methods. When using same capsule, less porosity was observed on PFQ than F2LC. When using same mixing mehod, less porosity was observed on Rotomix than CM-II. Using mixing machine of same coporation as that of RMGI capsule did not lead to lower porosity. Therefore, Selecting optimal mixing machine is important.

Effect of surface sealant on surface roughness of dental composite with different surface roughness (서로 다른 거칠기의 복합레진에 표면 강화제 도포시 표면 거칠기의 변화)

  • Dong-Ah Shin;Seon-Ju Jin;Kkot-Byeol Bae;In-Nam Hwang
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.195-203
    • /
    • 2023
  • Purpose: This study aimed to evaluate the influence of surface sealants on the surface roughness of composite resins. Materials and Methods: The study used microfilled composite resin (Metafil CX, Sun Medical Co.) and hybrid composite resin (AeliteTM LS posterior, Bisco). Sixty specimens (8 mm in diameter and 4 mm in height) of each composite resin type were prepared and divided into 3 groups. Each specimen was ground with 600, 1000, and 2000-grit sandpaper. The Surface roughness (Ra) values were measured using a surface roughness tester (SJ-301, Mytutoyo) before and after surface sealant application. Surface sealants, BisCoverTM LV (Bisco), Optiguard® (Kerr), and Seal-n-ShineTM (Pulpdent), were applied to the specimens, as instructed and observed by scanning electron microscope (JSM-7500, JEOL) and atomic force microscope (MultiMode IV, Veeco Instruments). Results: Specimens ground with 600-grit sandpaper coated with surface sealants exhibited significantly lower Ra values than the untreated group (P < 0.05). Specimens ground with 1000 and 2000-grit sandpaper showed statistically no difference. There was no significant difference in surface roughness among BisCoverTM LV, Optiguard®, and Seal-n-ShineTM. SEM and AFM revealed remarkably decreased microdefects on the surfaces of composite resins after surface sealant application. Conclusion: Surface sealants can influence surface roughness when applied on the rough surface of composite resins but not on highly polished composite resins.