• Title/Summary/Keyword: Occlusion area

Search Result 437, Processing Time 0.032 seconds

Gender Differences in Nasalance Scores in Korean Speaking Adults (비음측정기를 이용한 한국어를 사용하는 정상 성인에서 성별에 따른 비음도의 차이에 관한 연구)

  • Kwon, Ho-Beom;Choi, Song-Un;Chang, Seok-Woo;Lee, Seok-Hyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.1
    • /
    • pp.19-27
    • /
    • 2008
  • The purpose of this study was to obtain normative nasalance scores for adult subjects speaking the Korean language and to determine whether significantly different scores exist for female and male speakers. Mean nasalance scores were obtained for normal speaking Korean adults while they are reading vowels, consonants, no nasal sentence, mild nasal sentence, and high nasal sentence. Thirty adults who had lived in Seoul area with normal articulation, resonance, and voice were included. Among the subjects 15 were male aged 24-38 years and 15 were female aged 19-33. Nasometer data were collected and analyzed using the Kay Nasometer 6400. Nasalance scores were evaluated to investigate the effect of gender by using statistical tests. Nasalance data showed that nasalance values varied accroding to speech stimuli, and there was no significant difference in nasalance scores between male and female speakers in most of the language samples.

Effects of Dipsaci Radix on Muscle Fiber Atrophy and MyoD Expression in Gastrocnemius of MeAO Rats (속단(續斷)이 중풍모델 흰쥐 비목근의 근섬유위축 및 MyoD 발현에 미치는 영향)

  • Han, Sang-Woo;Ryu, Sa-Hyun;Shim, Eun-Sheb;Lee, Dong-Eun;Park, Min-Hee;Kim, Bum-Hoi;Choi, Hyun;Jung, Hyuk-Sang;Sohn, Nak-Won;Sohn, Young-Joo
    • The Korea Journal of Herbology
    • /
    • v.23 no.2
    • /
    • pp.159-168
    • /
    • 2008
  • Objectives : The present study has been undertaken to investigate the effects of Dipsaci Radix on Muscle Fiber Atrophy and MyoD Expression in Gastrocnemius of MCAO Rats Methods : In order to investigate effects of Dipsaci radix on the skeletal muscle atrophy following stroke, cerebral infarct was induced by the middle cerebral artery occlusion (MCAO) in the rats. Water extract of Dipsaci radix (184.4 mg/100 g) was treated for 4 weeks, once a day orally, after the MCAO. Effects were evaluated with muscle fiber type composition and cross-sectioned area of muscle fibers in gastrocnemius of the unaffected & affected hind limbs. And MyoD protein expression in gastrocnemius was demonstrated with immunohistochemistry and western blotting. Results : Obtained results were as follows; 1. Infarct volume was not attenuated by Dipsaci radix treatment in the MCAO rats. 2. At the affected-side hind limb of the MCAO rats, the increase of type-I fibers and the decrease of type-II fibers were induced by Dipsaci radix treatment. 3. At the affected-side hind limb of the MCAO rats, decreases of cross-sectioned areas of type-I and type-II fibers were attenuated by Dipsaci radix treatment. 4. At the affected-side hind limb of the MCAO rats, MyoD positive cells were increased by Dipsaci radix treatment. 5. At the affected-side hind limb of the MCAO rats, MyoD expressions were increased by Dipsaci radix treatment. Conclusions : These results suggest that Dipsaci radix has a protective effect against muscle atrophy, through the inhibition of the muscle cell apoptosis, following the central nervous system demage.

  • PDF

Validity of midsagittal reference planes constructed in 3D CT images (전산화단층사진을 이용한 3차원 영상에서 정중시상기준평면 설정에 관한 연구)

  • Jeon, Ye-Na;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.37 no.3 s.122
    • /
    • pp.182-191
    • /
    • 2007
  • Objective: The purpose of this study was to evaluate the validity of midsagittal reference (MSR) planes constructed in maxillofacial 3D images. Methods: Maxillofacial computed tomography (CT) images were obtained in 36 normal occlusion individuals who did not have apparent facial asymmetry, and 3D images were reconstructed using a computer software. Six MSR planes (Cg-ANS-Ba, Cg-ANS-Op, Cg-PNS-Ba, Cg-PNS-OP, FH${\perp}$(Cg, Ba), FH${\perp}$(Cg, Op)) were constructed using the landmarks located in the midsagittal area of the maxillofacial structure, such as Cg, ANS, PNS, Ba and Op, and FH plane constructed with Po and Or. The six pairs of landmarks (Z, Fr, Fs, Zy, Mx, Ms), which represent right and left symmetry in the maxillofacial structure, were selected. Statistically significant differences of the right and the left measurements were examined through t-test, and the difference of the right and the left measurement was compared among the six MSR planes. Results: The distances from the right and the left landmarks in each pair to each MSR plane did not show a statistically significant difference. The reproducibility of the landmark identification was excellent. Conclusion: All the six planes constructed in this study can be used as a MSR plane in maxillofacial 3D analysis, particularly, the planes including Cg and ANS.

A Study on Surface Characteristics and Stability of Implants Treated with Anodic Oxidation and Fluoride Incorporation (양극 산화와 불소 화합물로 처리한 임플랜트의 표면 특성 및 골유착 안정성에 관한 연구)

  • Lim, Jae-Bin;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.4
    • /
    • pp.349-365
    • /
    • 2006
  • State of problem : A number of investigation about increase of surface area via various surface treatments and modification of surface constituent have been carried out. Purpose : The surface characteristics and stability of implants treated with anodic oxidation, fluoride ion incorporation, and groups treated with both methods were evaluated. Material and method : Specimens were divided into six groups, group 1 was the control group with machined surface implants, groups 2 and 3 were anodic oxidized implants (group 2 was treated with 1M $H_2SO_4$ and 185V, group 3 was treated with 0.25M $H_2SO_4$ and $H_3PO_4$ and 300V). Groups 4, 5 and 6 were treated with fluoride. Group 4 was machined implants treated with 0.1% HF, and groups 5 and 6 were groups 2 and 3 treated with 10% NaF respectively. Using variable methods, implant surface characteristics were observed, and the implant stability was evaluated on rabbit tibia at 0, 4, 8 and 12 weeks. Result : 1. In comparison of the surface characteristics of anodic oxidized groups, group 2 displayed delicate and uniform oxidation layer with small pore size containing Ti, C, O and showed mainly rutile, but group 3 displayed large pore size and irregular oxidation layer with many crators. 2. In comparison of the surface characteristics of fluoride treated groups 4, 5, 6 and non-fluoride treated groups 1, 2, 3, the configurations were similar but the fluoride treated groups displayed rougher surfaces and composition analysis revealed fluoride in groups 4, 5, 6. 3. The fluoride incorporated anodic oxidized groups showed the highest resonance frequency values and removal torque values, and the values decreased in the order of anodic oxidized groups, fluoride treated group, control group. 4. According to implant stability tests, group 2 and 3 showed significantly higher values than the control group (P<.05). The fluoride treated groups showed relatively higher values than the non fluoride treated groups and there were significant difference between group 4 and group 1 (P<.05). Conclusion : From the results above, it can be considered that the anodic oxidation method is an effective method to increase initial bone stability and osseointegration and fluoride containing implant surfaces enhance new bone formation. Implants containing both of these methods should increase osseointegration, and reduce the healing period.

Stress Analysis on the Supporting Bone around the Implant According to the Vertical Bone Level (치조골 높이가 다른 임프란트 주위 지지골 응력분석)

  • Boo, Soo-Boong;Jeung, Jei-Ok;Lee, Seung-Hoon;Kim, Chang-Hyun;Lee, Seung-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.1
    • /
    • pp.55-68
    • /
    • 2007
  • The purpose of this study was to analyze the distribution of stress in the surrounding bone around implant placed in the first and second molar region. Two different three-dimensional finite element model were designed according to vertical bone level around fixture ($4.0mm{\times}11.5mm$) on the second molar region. A mandibular segment containing two implant-abutments and a two-unit bridge system was molded as a cancellous core surrounded by a 2mm cortical layer. The mesial and distal section planes of the model were not covered by cortical bone and were constrained in all directions at the nodes. Two vertical loads and oblique loads of 200 N were applied at the center of occlusal surface (load A) or at a position of 2mm apart buccally from the center (load B). Von-Mises stresses were analyzed in the supporting bone. The results were as follows; 1. With the vertical load at the center of occlusal surface, the stress pattern on the cortical and cancellous bones around the implant on model 1 and 2 was changed, while the stress pattern on the cancellous bone with oblique load was not. 2. With the vertical load at the center of occlusal surface, the maximum von-Mises stress appeared in the outer distal side of the cortical bone on Model 1 and 2, while the maximum von-Mises stress appeared in the distal and lingual distal side of the cortical bone with oblique load. 3. With the vertical load at a position of 2 mm apart buccally from the center, there was the distribution of stress on the upper portion of the implant-bone interface and the cortical bone except for the cancellous bone, while there was a distribution of stress on the cancellous bones at the apical and lingual sides around the fixture and on the cortical bone with oblique load. 4. With the changes of the supporting bone on the second molar area, the stress pattern on the upper part of the cortical bone between two implants was changed, while the stress pattern on the cancellous bone was not. The results of this study suggest that establishing the optimum occlusal contact considering the direction and position of the load from the standpoint of stress distribution of surrounding bone will be clinically useful.

Evaluation of the Volume Changes of Grafted Bone Materials in Sinus Augmentation Procedure Using Dental Cone-beam CT (치과용 Cone-beam CT를 이용한 상악동 골 이식 후 나타난 골 이식재의 부피 변화평가)

  • Ohn, Byung-Hun;Seon, Hwa-Kyeong;Chee, Young-Deok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.23-36
    • /
    • 2013
  • To evaluate the 3-dimensional features of the grafted bone with maxillary sinus augmentation and to assess the relation between the degree of bone resorption and the type of bone grafting source and implant, and the operation method. A retrospective chart review of patients receiving sinus augmentation procedures for implant positioning was conducted: radiographic analysis of the volume and area of bone grafts was performed. The volumetric remodeling.measured at 6 months after implant positioning as the percentage of residual bone graft.was correlated to type of graft materials and operation methods. 53 dental implants positioned with sinus bone graft in 15 patients at Wonkwang University Sanbon Dental Hospital. Computed tomography scans,taken implant positioning after 6 months, showed greater resorption values for the group of $Puros^{(R)}$ graft alone from the group of mixed with $Puros^{(R)}$ and various bone graft (P<0.05, respectively). And resorption values according to operation methods have statistically significant difference(P<0.05). Volume change ratio of bone graft showed greater values for the group of delayed implant position from the group of simultaneously implant placement with bone graft. Retrospective data analysis shows that the method of graft with $Puros^{(R)}$ alone may occur greater resorption of graft materials than mixed graft material with $Puros^{(R)}$ and other graft materials. The group of simultaneously implant placement with bone graft also display smaller resorption ratio of bone graft than the group of delayed implant placement.

The efficacy of ultrasonic irrigation technique on debris removal during root canal treatment (근관치료 시 초음파 세정 기술을 이용한 잔사 제거의 효율성)

  • Kim, Jeong-Hyeon;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.2
    • /
    • pp.97-105
    • /
    • 2017
  • Purpose: The purpose of this study was comparing the efficacy of passive irrigation (PI) and passive ultrasonic irrigation (PUI) for ability to remove debriment of canals. Materials and Methods: Mandibular premolars were decoronated and standardized to 16 mm length. After root canal enlargement and half separating longitudinally, standardized groove of 4 mm length, 0.2 mm width and 0.5 mm depth were formed on the dentin wall of one half. Three depressions in the canal wall of the opposite half, 0.3 mm in diameter and 0.5 mm in depth, were formed. After each groove and depression was filled with dentin debris, two sections of each half were reassembled using impression putty material. In group 1 the canals were irrigated with 2.5% NaOCl by PI. In group 2 the canals were irrigated with 2.5% NaOCl by PUI. Before and after root canal irrigation, the root canal wall of the section was taken with a microscope and a digital camera as images. The amount of dentin debris remaining in grooves and depressions was assessed using a scoring system. Results: There was no significant difference between PI and PUI except for the middle 1/3 of the root canal (P = 0.004). Conclusion: At the middle 1/3 of the root canal, PUI removed more dentine debris than PI. But the removal efficiency of dentin debris is not significantly different between the PUI and PI at the apical area of root canal in mandibular premolars.

Evaluation of the stability of sandblasted, large-grit, acid-etched implants with tapered straight body design (테이퍼드 직선형 SLA 임플란트의 안정성 평가)

  • Kim, Yong-Gun;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.80-88
    • /
    • 2018
  • Purpose: Implant surface modification and implant design are the principle targets for achieving successful primary stability. The aim of this study was to measure implant stability quotient (ISQ) values of sandblasted, large-grit, acid-etched (SLA) implants with tapered straight body design during the healing period, and to determine the various factors affecting implant stability. Materials and Methods: To measure implant stability, resonance frequency analysis (RFA) was performed in 26 patients (13 women and 13 men) with 44 SLA implants with tapered straight body design. Implant stability (ISQ values) was evaluated at baseline and healing abutment connection (12 weeks), and the correlations between RFA and insertion torque (IT), bone quality, and jawbone were determined. Results: The mean ISQ value of the implants was $69.4{\pm}10.2$ at the time of implant placement (baseline) and $81.4{\pm}6.9$ at the time of healing abutment connection (P < 0.05). Significant differences were found between RFA and bone quality and between RFA and jawbone (P < 0.05). No significant differences were found between RFA and IT, insertion area, fixture diameter, and implant length (P > 0.05). Conclusion: ISQ values of SLA implants with tapered straight body design were high at baseline and healing abutment connection. It was concluded that SLA implants with tapered straight body design show improved primary and secondary stability, and that immediate or early loading may be applicable.

Debris removal efficiency depend on different ultrasonic irrigation protocols (초음파 세정 프로토콜에 따른 근관 내 잔사 제거의 효율성 비교)

  • Heo, Gun;Kim, Jin-Woo;Cho, Kyung-Mo;Enkhbileg, Nyamsuren;Lee, Eun-Hye;Park, Se-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.104-111
    • /
    • 2020
  • Purpose: The purpose of this study is comparing the efficiency of debris removal of passive ultrasonic irrigation depend on different protocols. Materials and Methods: Forty-eight mandibular premolars were randomly divided into 2 groups depend on vibration power (Weak and Strong, n = 24). And then two groups were subdivided into 3 groups depend on the number of times that PUI used (1, 2 and 3, n = 8). After standardization, teeth were split into two halves. On the wall of one half of root canal, three depressions were cut at 1, 3 and 5 mm from the apex and in the same way two depressions were cut on the other half of root canal at 2, 4 mm from the apex. Each depression was filled with mixture of dentine and NaOCl. After irrigation, images of the root canal wall were taken, and then the amount of remaining dentine debris was evaluated. Results: There was no significant difference between weak and strong power of vibration groups. Weak vibration groups did not show significant difference depend on the different number of times PUI used. But in the strong vibration groups, twice and three times used groups show better removal efficiency. Conclusion: The removal efficiency of dentine debris is not significantly different depend on the power of vibration. And multiple use of PUI could have better irrigating effects at the apical third area in the strong vibration group.

Central Giant Cell Granuloma of the Mandible: A Case Report (하악에 발생한 중심성 거대세포육아종의 치험례)

  • Chung, Jin-Wook;Oh, Deuk-Young;Seo, Je-Won;Moon, Suk-Ho;Lee, Jung-Ho;Rhie, Jong-Won;Ahn, Sang-Tae;Kim, Chang-Hyun
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.691-694
    • /
    • 2010
  • Purpose: Central giant cell granuloma is a rare, benign giant cell tumor which commonly develops in areas near the teeth. It accounts for approximately less than 7% of benign tumors of the mandible. Clinically, central giant cell granuloma is classifed into aggressive and non-aggressive type, and usually requires surgical treatment. There has been no report of central giant cell granuloma in plastic surgery field of the country, and we report a case with a brief review of the diagnosis and treatment of the disease. Methods: A 23-year-old male presented with a hard, non-tender, growing mass with the size of $4.0{\times}3.0\;cm$ on mandible for several months. Computed tomography scan showed a solid mass within thinned outer cortex on mandible. The thinned outer cortex was excised with the mass and the inner cortex was partially removed burring. After the tumor removal, mandible was fixed by reconstruction plate. Results: Pathologic report showed numerous large multinucleated giant cells, diffusely distributed in a background of ovoid-to-spindle-shaped mononuclear cells. There was no evidence of recurrence after 1 year follow up. Bony defect was regenerated and we removed the reconstruction plate. Conclusion: Removal of central giant cell granuloma results in defect of outer cortex, which can be reconstructed by using reconstruction plate, autologous bone graft or bone cement. We used reconstruction plate as a conservative method to induce secondary healing of the outer cortical defect area, which resulted in normal mastication and occlusion with no recurrence.