Journal of Dental Rehabilitation and Applied Science
/
v.28
no.2
/
pp.213-221
/
2012
The purpose of this study was to evaluate the stability of external stain that long term attrition caused by tooth brushing affected the color variation of external stain of IPS e.max Press Porcelain. The specimen was made by IPS e.max Press LT ingots, and treated the shade of external staning as Orange, A, B, C, D After conducting horizontal toothbrush strokes about 11,000 / 22,000 / 44,000 / 66,000 / 88,000, Color changers of the external stained layer was measured with SpectroShade$^{tm}$ MICRO(MHT, Italy). The result of this study was obtained as follows: 1. After 11,000 strokes, the color changes of shade were greater in Orange shade than the other 4 shade groups. And even though toothbrush strokes were increased until 88,000, there were no statistical significant color changes about the external stain shade variation. 2. The amount of color variation about increasing of toothbrushing strokes was irregular(no consistent increasing, or decreasing), and it was no statistical significant changes According to these results, the long term tooth-brushing doesn't affect the changes of external stain about IPS e.max press porcelain. And it doesn't reduce the stability of external stain clinically. Later, it will be needed to study other factors affecting the external stain.
Jo, Yun-Sung;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee
Journal of Dental Rehabilitation and Applied Science
/
v.28
no.1
/
pp.57-66
/
2012
The purpose of this study was to evaluate the relation between intentionally induced internal stress and cyclic fatigue failure of ProTaper Universal. ProTaper Universal (Dentsply Maillefer) S1, S2, F1, F2, F3, F4 and F5 (25 mm length) were used in this study. To give the internal stress, the ProTaper Universal were put into the .02 taper Endo-Training-Bloc (Dentsply Maillefer) until auto-stop by torque controlled motor. The rotation speed was 300 rpm and torque value was 1.0 Ncm. ProTaper Universal were grouped by the induced number of internal stress and randomly distributed among one control group and three experimental groups (n=10). The four groups were Stress 0 (control), Stress 1, Stress 2 and Stress 3. These instruments were rotated until separation. For cyclic fatigue measurement, inclined plane was used and time for separation was recorded. It was statistically analyzed using two-way ANOVA and Duncan post-hoc test at 95% confidential level. In all ProTaper Universal, there was statistically significant decrease on time for separation in Stress 3. In F2 and F3, there were statistically significant difference between control group and all experimental groups. And in F4 and F5, Stress 2 and 3 groups showed significantly lower cyclic fatigue resistance from Stress 0 group. In the limitation of this study, cyclic fatigue failure of ProTaper Universal is influenced by accumulated internal stress.
Journal of Dental Rehabilitation and Applied Science
/
v.25
no.2
/
pp.157-169
/
2009
The aim of this study was to evaluate effect of implant abutment screw coating treatment on joint stability, investigating mechanical properties of these. For this study used $ExFeel^{(R)}$ external hexed implant system and $15mm{\times}1mm$ discs. Experimental group was $1{\mu}m$ TiN, TiCN, TiC coated abutment screws and discs. To know mechanical property, i evaluated adhesion strength, surface hardness, using disc, corrosion test using screw. The results were as follows : rotation angle of coated screws increased than that of non-coated screw because of lower friction coefficient, especially TiC coated screw group had the largest value, but removal torque decreased in all coated screws (p<0.05). Torque loss before and after fatigue test was the smallest in TiC-coated screws, and the largest in non-coated screws (p<0.05), and there was no statistically significant difference between dry condition and wet condition of screws because of higher surface hardness and lower friction coefficient. From the above results, TiN, TiCN, TiC coating group had high abrasion resistance, especially TiC coated group which had low torque-consuming, high rotation angle as low friction coefficient will be considered to influence on implant abutment screw joint stability positively.
Journal of Dental Rehabilitation and Applied Science
/
v.30
no.2
/
pp.102-111
/
2014
Purpose: Surface damage and bonding strength difference after micromechanical treatment of zirconia surface are to be studied yet. The aim of this study was to evaluate the difference of fracture resistance and bonding strength between more surface-damaged group from higher air-blasting particle size and pressure, and less damaged group. Materials and Methods: Disk shape zirconia ($LAVA^{TM}$) was sintered and air-blasted with $30{\mu}m$ particle size (Cojet), under 2.8 bar for 15 seconds, $110{\mu}m$ particle size (Rocatec), under 2.8 bar for 15 seconds, and $110{\mu}m$ particle size (Rocatec), under 3.8 bar for 30 seconds respectively. Biaxial flexure test and bonding failure load test were performed serially (n = 10 per group). For bonding test, specimens were bonded on the base material having similar modulus of elasticity of dentin with $200{\mu}m$-thick resin cement for tension of surface damage. Failure load of bonding was detected with acoustic emission (AE) sensor. Results: There were no significant differences both in the biaxial flexure test and bonding failure load test between groups (P > 0.05). Sub-surface cracks were all radial cracks except for two specimens. Conclusion: Within the limitations of no aging under monotonic load test, surface damage from higher air-blasting particle size and pressure was not significant. Evaluations of failure load with bonded zirconia disks was clinically relevant modality for surface damage and bonding strength, simultaneously.
Journal of Dental Rehabilitation and Applied Science
/
v.30
no.2
/
pp.145-151
/
2014
Purpose: The purpose of this study was to investigate the microleakage in class II cavity resin restorations used with resin-modified glass ionomer (RMGI) lining material depending on two different applying methods; classical delivery method using a dental explorer and a specially designed rotating bur. Materials and Methods: A total thirty-six extracted teeth were prepared with a class II proximal box, and randomly divided into three groups: 1) control group with no lining added and the proximal box restored (Group I), 2) the second group used RMGI as a lining material which was spread with an explorer (Group II), 3) the third group used a specially designed rotating bur to thin out RMGI (Group III). All teeth were restored with the same manner using incrementally placed resin composite. All 36 teeth were prepared and sectioned for the dye penetration test, and observed with a stereomicroscope for scoring the dye penetration. Results: When RMGI liners were used, both groups using an explorer and the special bur with the liner had significantly less microleakage than the control group with no liner (P < 0.05). The 50% of the group with RMGI liner using the bur showed no microleakage under a dye penetration test whereas all the teeth in control group showed microleakage of different degrees. However, there was no statistically significant difference between Group II and Group III. Conclusion: RMGI is an effective lining material to decrease microleakage in class II composite resin restorations regardless of applying methods.
Journal of Dental Rehabilitation and Applied Science
/
v.30
no.2
/
pp.138-144
/
2014
Purpose: This study examined the water sorption of commonly used dual-cure resin cements and compared the change in the micro-hardness among the cements. Materials and Methods: Five types of dual-cure resin cements (Maxcem, Duo-link, Panavia F, Variolink II, Rely X Unicem) were selected. Fifty specimens were classified into five groups containing ten specimens in each group. The water sorption of the five specimens in each group was evaluated after being immersed in distilled water (DDW) for seven days. The following results were obtained by comparing the specimens immersed in DDW with those not immersed in DDW. Results: 1. The water sorption of Maxcem showed the highest score, followed by Panavia F. These two cements were followed by Duo-link and Rely X Unicem. The water sorption of Variolink II showed the lowest score among the cements used in this study. 2. Among the specimens not immersed in DDW, the micro-hardness of Rely X Unicem showed the highest score followed by Panavia F and Variolink II. These cements were followed in order by Duo-link and Maxcem. 3. Among the specimens immersed in DDW, the microhardness of Rely X Unicem showed the highest score followed by Maxcem, Panavia F and Variolink II. Duo-link shoed the lowest score among the cements used in this study. 4. Maxcem, Duo-link, Panavia F and Rely X Unicem showed significant differences in micro-hardness due to water resorption but Variolink II was unaffected by immersion in water. Conclusion: Using the resin cement which has lower water sorption and higher micro-hardness is recommended.
Journal of Dental Rehabilitation and Applied Science
/
v.29
no.3
/
pp.249-258
/
2013
The purpose of this study was to investigate how image magnification in dental panoramic radiography is influenced by object position. Five metal balls (4 mm in diameter, 2 for the anterior and 3 for the posterior region on the right side) were placed above alveolar crest of dry skull considering extraction socket and dental arch. Dry skull was radiographed using OP-100D (Instrumentarium Imaging Co., Tuusula, Finland) at proper and displaced position along the sagittal and transverse plane at 3 mm, 6 mm, 9 mm, 12 mm and 15 mm using special mount which can control precise movement. Images were stored in DICOM files and were measured by ruler equipped within INFINITT PACS software (Infinitt Co., Ltd., Seoul, Korea). The mean horizontal magnification was 1.224-1.439 and mean vertical magnification was 1.286 - 1.345 at proper position. Vertical magnification resulted in less variation (1.245-1.418) than horizontal magnification (0.798-6.297) according to the sagittal and transverse displacements. Head positioning is important for linear measurement on panoramic radiography and inclusion of standard object (for instance, metal ball) is helpful to anticipate exact magnification of panoramic radiographs at various location.
Journal of Dental Rehabilitation and Applied Science
/
v.29
no.3
/
pp.308-316
/
2013
The purpose of this study is to investigate the production method of posterior bridges pontic ridge lap type which prevents the infection in bridge pontic base and is able to cleanse itself, in the process of producing final prothesis that maintains healthy mucous membrane of oral cavity and interproximal papilla, minimizing diastema, is aesthetic and has no effect on pronunciation. New technology is applied to make optimal pontic base which prevent inflammation and clean itself and its products were clinically evaluated in 10 places of dental clinics in busan and gyeongnam. The making of posterior 3 unit bridge pontic base, it was presented as the new technology of forming ridge lab type and to carry out clinical validation, existing conventional method and the new technology were compared. Pontic base made with the existing conventional method cause infection and other periodontal disease by 96% but the pontic base made with the new technology cause infection and other periodontal disease by 3%. Remains of food cause infection and other periodontal disease 100% by the existing conventional method and 91% by the new technology, showing a distinct difference. However, after a gargle, the new technology had low 13%. Additionally, the pontic base made with the existing conventional method showed 71% of chance, the new technology method showed 8% of chance in terms of self-cleansing.
Purpose : The objective of this study is to serve guidelines for the investigation and management of uterine myomas with KM therapies. Methods : English-language articles from PubMed and Korean-language articles from the database of the journal of oriental gynecology were reviewed from 2000 to 2005, using the key words 'uterine myoma', 'uterine leiomyoma', 'fibroid', 'uterine artery embolization', 'endometrial ablation', 'myomectomy', and jagungguenjong(子宮筋腫)'. Results and Limits : The areas of clinical practices considered in formulating this guideline are assessment, KM therapies, medical treatments, myolysis, selective artery occlusion, endometrial ablation and surgical therapies including myomectomy and hysterectomy. Implementation of this guideline would optimize the decision-making process of women with uterine myomas and further investigation or therapy of their KM doctors. But we don't have abundant evidences of clinical trials of uterine myoma treated with KM therapy, though we treat or manage that with every-day clinical practices. Moreover cultural gaps between Korea and other western countries make many differences in the attitude to surgical therapies, especially hysterectomy. So it is very difficult to compare W therapies with other therapies. Moreover it is much difficult to estimate cost-effectiveness and benefit of those therapies in QOL. Conclusions : The majority of uterine myoma is asymptomatic and will not require any intervention or further investigation. But unmarried women who wish to marry and get pregnant want to find safe therapy for their asymptomatic uterine myomas. In that case, most of the patients prefer non-surgical therapy to surgical therapy. So KM herbal medicinal therapy is a good alternative method for those patients. For the symptomatic myomas, hysterectomy offers a definitive solution. However, it is not the best solution for women who wish to preserve their uterus. So KM therapy is a good alternative for them. But the predicted benefits of alternative therapies including KM therapy must be carefully weighed against the Possible risks of these therapies. To improve the quality of life of both women with asymptomatic and symptomatic myomas, selecting and treating patients should be done carefully. Moreover, the effect of KM therapy has to evaluated, comparing the possible situation without treatment and the benefit of constant treatment as a health-care system.
Kim, Kyung-Sun;Youn, Dae-Hwan;Hong, Seok;Na, Chang-Su
Korean Journal of Acupuncture
/
v.22
no.3
/
pp.137-156
/
2005
Objectives : Cnidium officinale(CO) has been used for medication for stroke in the Oriental Medicine. So this study was planned to investigate the effects of CO on the focal ischemia-induced by Middle Cerebral Artery Occlusion(MCAO) in rats Materials and methods : The focal ischemia was induced by MCAO. CO extracts through oral administration and herbal acupuncture at GB2l was carried out during 3 weeks after focal ischemia-induced. Eight-arm radial maze was used for the behavioral task. For the neuroprotective effect of CO, we investigated AchE, ChAT, and NGF-expression by immnohistochemical method. Results : The error rate in the eight-arm radial maze task was significantly decreased in normal group compared to control group on 1-6days, OA-CO1(CO oral administration, 0.8g/kg) group on 1-6days, OA-CO2(CO oral administration, 1.6g/kg) group on 1-3,5,6days, HA-CO1(CO herbal acupuncture, 0.016g/kg) group on 2,3,6days, HA-CO2(CO herbal acupuncture, 0.008g/kg) group on 1-3,5,6days. The rate of correct choice was significantly increased in OA-CO1, HA-CO2. The density of neurons in the hippocampal CA1 was the most increased in OA-CO1, HA-CO1, HA-CO2. The density of ChAT in the hippocampal CA1 was increased in OA-CO1, HA-CO2. The density of ChAT in the hippocampal CA1 was significantly increased in OA-CO1, HA-CO2. The density of NGE in the hippocampal CAI was significantly increased in OA-CO1, OA-CO2, HA-CO2. Conclusions : These results suggest that CO oral administration with 0.8g/kg and CO herbal acupuncture with 0.008g/kg might be used as a regulator of cell death of cholinergic system induced by stroke.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.