• Title/Summary/Keyword: Obstacle Installation

Search Result 50, Processing Time 0.022 seconds

Variation of Hydraulic Characteristics around a Cylindrical Bridge Pier with Circular Collar (원환 설치에 의한 원형교각 주위의 수리특성변화)

  • Jin, Byoung-Ho;Sim, Ou-Bae;Song, Jai-Woo
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.3 no.2 s.9
    • /
    • pp.147-154
    • /
    • 2003
  • In this study, hydraulic characteristics around bridge piers were analyzed with and without collar through a hydraulic model experiment. The analysis of stage variation in front and back side of pier showed that collar installation did not function as obstacle to the stream flow. Little variation of water level between front and back sides of pier was observed before and after collar installation(0.2cm in front side and 0.1cm in back side of pier). Also, result that analyze velocity variation in front and back side of pier, lateral velocity(u) and transverse(v) before and after collar installation exhibited no alteration in the front and back side of pier. About 16.72% and 15.83% of vertical velocities(w) were reduced for the condition of y/d=0.33 in the front side of pier and y/d=0.67 in the back side of pier, respectively. This experimental results suggest that the collar installation around pier can minimize the local scouring depth by preventing the downflow that cause the pier scour.

A Study on Comparison of the Characteristic Test of Discharge Water Flowmeters (Electromagnetic Flowmeter, Parshall Flume) (방류수 유량계(전자기유량계, 파샬플룸)의 특성평가 연구)

  • An, Yang-ki;Kim, Jee-young;Kim, Kum-hee;Jang, Hee-soo;Jung, Jung-pil;Choi, Jong-woo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.6
    • /
    • pp.57-62
    • /
    • 2015
  • The test of comparing liquid flow calibration system (approved by KOLAS) for accuracy and structure change test was performed in the test bed in order to evaluate the typical characteristics of the electromagnetic flow meters and parshall flume that are generally used in the water discharging facilities. The results of the accuracy comparing test with liquid flow calibration system showed the error of less than 2%. Pharshall plume got error up to -8.3% (low flow) from the flow rate test, but less than 4% from the accumulated flow test because of offset error at high flow rate and low flow rate. Evaluation of structual change test was tested with only parshall flume using structure and it consisted of installation angle (parshall flume and level sensor) and position change. Installation angle, water level sensor angle and position changing test for parshall flume had errors of 3.1%~-9.2%, 0.4%~-5.6% and 0.2%~1.3% respectively. Especially, the error showed the largest increase when the water level sensor measured the point of decreased flow by the structure change. Therefore, error factors (change of straight pipe length, installation of obstacle or effect of foreign substances on water level sensor) that can often occur in the field should be derived and the research for optimized installation method should be carried out continuously.

Navigation of Autonomous Mobile Robot using Fuzzy Neural Network (퍼지-뉴럴 네트워크를 이용한 자율 이동로봇의 운항)

  • Choi, Jeong-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.19-25
    • /
    • 2008
  • This paper proposes a hierarchically structured navigation algorithm for autonomous mobile robot under unknown environment based on fuzzy-neal network. The proposed algorithm consists of two basic layers as follows. The lower layer consists of two parts such as fuzzy algorithm for goal approach and fuzzy-neural algorithm for obstacle avoidance. The upper layer which is basically fuzzy algorithm adjusts the magnitude of the weighting factor depending on the environmental situation. The proposed algorithm provides an efficient method to escape local mimimum points as shown in the simulation result. Most simulation results show that this algorithm is very effective for autonomous mobile robots' traveling in unknown field.

A Study About Fact Influence on Performance at Indoor Visible Light Communication (실내 가시광 통신 시스템에서 성능에 영향을 주는 요인에 관한 연구)

  • Yi, Chang-Woo;Choi, Deok-Jai;Kim, Han-Pil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.10
    • /
    • pp.1-8
    • /
    • 2013
  • Wireless Visible Light Communication is the technology that enables communication using LED illumination Infrastructure instead of existing illumination such as incandescent lamp or fluorescent light. Because VLC uses light for communication, it has no problem of frequency permission and is harmless to human body. It is also possible to check the communication through eye. So VLC can be used as a supplement to the Radio Frequency communication, Infrared in indoor environment. So far, researchers on the LED Visible light communication have focused on the increasing transmission speed, transmission distance, modulation method. However, there is few research of main factors that influence on system performance. System performance has been mainly predicted through simulation. In this paper, I recognized that these factors such as outside light noise, obstacle, LED panel position or emitted angle have a great impact on wireless communication system. So I experimented VLC system by changing distance and position to discover location suitable for BER regulation.

A Design of Insulted Diagnosis Sensor and the Characteristics of Frequency Spectrum from the Radiated Electromagnetic Waves according to Surface Discharge (GIS 절연진단센서 설계와 연면방전에 따른 방사전자파 특성)

  • Park, Sung-Gyu;Choi, Eun-Hyeok;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.10
    • /
    • pp.27-34
    • /
    • 2012
  • If obstacle in GIS(Gas Insulted Switchgear), its affects are great are on the community and it is consequently demanded lots of difficulities to recover and repair. Accordingly, diagnosis techniques, that are able to prevent from accidents before they happen by providing more stable and highly reliable power effectively and finding sign of the accidents is very important. A novel UHF(Ultra High Frequency)-microstrip antenna is presented. The measured impedance bandwidth of the proposed antenna is from 0.5GHz to 15GHz with the stop band from 0.5GHz to 10.7GHz for VSWR<2. Form results of this study, The antenna is will play an important role for the senser for insulation diagnosis system by UHF method of real site GIS and power equipment using $SF_6$ gas.

A Study on the Design and Chracteristic Analysis for Noise Cut Transformer (NCT 설계 및 특성 분석에 관한 연구)

  • 이재복;허창수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.146-154
    • /
    • 1998
  • Broadband noise with frequency components in the range from several kHz up the tens of MHz is a major obstacle factor in normal operation of the AC line to supply the power to electrical and electronic control equipments. Because this kind of noise could damage the device or could be a source of malfunction, many devices such as filter and surge suppressor are used to cut off the noise. But those devices could not disconnected from the power line, so they result in poor common-mode of NCT as well as insulation characteristics as a isolation transformer in addition faraday shielding and proposed analysis model of NCT having tow functions of surge and noise reduction. The simulated and experimental results for the surge suppression characteristics are compared and evaluated for designed protype 1[kVA] NCT.

  • PDF

The Needs for Training Manpower and the Change in Construction Environment by Equipment Based BIM Design (설비분야 BIM 설계에 따른 건축환경 변화와 인재양성의 필요성)

  • Kim, Jong-Hwan
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.14 no.4
    • /
    • pp.157-165
    • /
    • 2011
  • The study figures out the alternatives of training BIM design experts which is the biggest obstacle in training manpower of professional BIM designer, the largest problem when the plant introduce BIM design about the change in Construction Environment by Equipment Based BIM Design in reality of design followed by equipment based BIM design, education institution plan. BIM is the system which is built to make these information be used easier and technique which enables design construction and maintenance in 3-dimensional virtual space by designing buildings in 3-dimensional space, and by data-basing the generated information of every life-cycle information. As the essential contents of the study, educational institutions with the public authority should invest the opening of educational programs, recruit of experts and development of textbooks from a long-term perspective. And also, the role of public institution is important above all for the development of construction industry.

Evaluation of Inverter DSM Program in KEPCO and Market Diffusion (인버터 DSM 프로그램 보급과 시장 전망)

  • Lee, Hak-Ju;Park, Jae-Duck;Kim, Yong-Jin;Yi, Sue-Muk
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.370-371
    • /
    • 2006
  • The electric demand increase, financial need for new power plant constructions and environmental problem have led to search for more efficient energy Production and energy conservation technology. To minimize the construction of power plants and reduce total power consumption include installation of inverters to motors used for pumps and fans. However, the high price of inverters is the biggest obstacle to their wide use. Accordingly, to maximize the effect of energy saving by the expanded use of inverters, governmental economic support as ell as the analysis of energy saving effect. his paper presents he present state analysis of inverter DSM program and propose he improvement for activation of inverter DSM program.

  • PDF

Economic Analysis of Inverter DSM Program for Inverter (인버터 DSM 프로그램의 경제성평가)

  • Lee, Hak-Ju;Kwon, Seong-Chul;Choi, Byoung-Yun;Lee, Seung-Yun
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.521-523
    • /
    • 2001
  • The electric demand increase, financial need for new power plant constructions and environmental problem have led to search for more efficient energy production and energy conservation technology. To minimize the construction of power plants and reduce total power consumption include installation of inverters to motors used for pumps and fans. However, the high price of Inverters is the biggest obstacle to their wide use. Accordingly, to maximize the effect of energy saving by the expanded use of inverters, governmental economic support as well as the analysis of energy saving effect. This paper presents the cost-effectiveness analysis for DSM program evaluation and case study to analyze inverter DSM program.

  • PDF

Rail Intruder and Obstacle Detection System for Railway Platform (철도 승강장 선로의 침입자 및 장애물 검지시스템에 관한 연구)

  • Kim, You-Ho;Kim, Jin-Cheol;Choi, Kwon-Hee;Pyeon, Seon-Ho;Hwang, Jong-Gyu
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.872-878
    • /
    • 2009
  • Passenger safety is a primary concern of the railway system. However, dozens of people are killed every year when they accidently fall on to the track from the boarding platform. This is one of the most urgent issues to solve regarding the railway platform. The installation environment, and the blind area problems as well as maintenance and operating costs which are not efficient have to be looked at. To solve these problems, we propose a 3D laser radar sensor based monitoring system for the railway platform. This paper introduces an overview, the detecting method, and the interface with the signalling system in detecting a fallen passenger from the platform using the 3D laser radar sensor.

  • PDF