• 제목/요약/키워드: Observation instrument

검색결과 243건 처리시간 0.03초

해양자원 탐사장비용 자원식별 알고리듬 개발 (A Study on the Detection Algorithm for exploration equipment of marine resources)

  • 김영진;조영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.141-142
    • /
    • 2007
  • The world-wide various nations is doing the development competition of marine resources for solving supply and non balance of the resources in compliance with depleting the land resources. Currently for exploring marine resources, After confirming the location of the resources by controlling search equipment and sensor module in research vessel, the method which collects sample of searched resources and analyzes the quality and a contents of the resources in research vessel is been applying. This search method is structure which analyzes an ingredient in ship and decides the quality of the resources. And real-time processing for an effective resources search is been demanding. Therefore in this paper, we have developed a resources identification algorithm that can display the type feature of resources by real-time 3D Graphic.

  • PDF

Phase dependent disk averaged spectra and light curve of the Earth as an habitable exoplanet : Ray-tracing based simulation using 3D optical earth system model

  • 류동옥;김성환;성세현
    • 천문학회보
    • /
    • 제37권2호
    • /
    • pp.108.1-108.1
    • /
    • 2012
  • Previously we introduced ray-tracing based 3D optical earth system model for specular and scattering properties of all components of the system (i.e. clear-sky atmosphere, land surfaces and an ocean surface). In this study, we enhanced 3-dimensional atmospheric structure with vertical atmospheric profiles for multiple layer and cloud layers using Lambertian and Mie theory. Then the phase dependent disk averaged spectra are calculated. The main results, simulated phase dependent disk averaged spectra and light curves, are compared with the 7 bands(300~1000nm) light curves data of the Earth obtained from High Resolution Instrument(HRI) in Deep Impact spacecraft during Earth flyby in 2008. We note that the results are comparable with the observation.

  • PDF

금속압력용기의 사용 전 음향방출시험 (Pre-service Acoustic Emission Testing for Metal Pressure Vessel)

  • 이종오;윤운하;이태희;이종규
    • 비파괴검사학회지
    • /
    • 제23권3호
    • /
    • pp.280-284
    • /
    • 2003
  • 사용하지 않은 새 금속 압력용기에 대하여, 사용 전 음향방출시험을 수행할 때 장비점검, 탐촉자간 거리, 탐촉자 위치, 전 측정 시스템 점검, 가압방법, 잡음 제거법 및 시험 결과의 평가 등에 대한 절차를 수립하고 현장 응용시험이 수행되었다. 일반적으로 음향방출 시험은 많은 잡음을 포함하는데 시험동안 관찰결과를 기록하여 평가 시 시간 필터링함으로서 잡음을 제거할 수 있었다.

Automatic modal identification and variability in measured modal vectors of a cable-stayed bridge

  • Ni, Y.Q.;Fan, K.Q.;Zheng, G.;Ko, J.M.
    • Structural Engineering and Mechanics
    • /
    • 제19권2호
    • /
    • pp.123-139
    • /
    • 2005
  • An automatic modal identification program is developed for continuous extraction of modal parameters of three cable-supported bridges in Hong Kong which are instrumented with a long-term monitoring system. The program employs the Complex Modal Indication Function (CMIF) algorithm for identifying modal properties from continuous ambient vibration measurements in an on-line manner. By using the LabVIEW graphical programming language, the software realizes the algorithm in Virtual Instrument (VI) style. The applicability and implementation issues of the developed software are demonstrated by using one-year measurement data acquired from 67 channels of accelerometers permanently installed on the cable-stayed Ting Kau Bridge. With the continuously identified results, variability in modal vectors due to varying environmental conditions and measurement errors is observed. Such an observation is very helpful for selection of appropriate measured modal vectors for structural health monitoring use.

Observation of the Bright Spectroscopic Binary Systems with DOAO/eShels Spectrograph

  • Shim, Hyunjin;Lee, Dongseob;Jeong, Yoonji;Kang, Wonseok;Kim, Taewoo
    • 천문학회보
    • /
    • 제43권2호
    • /
    • pp.51.1-51.1
    • /
    • 2018
  • Based on the DOAO/eShels observations, we have derived radial velocity curves of the three Algol-type spectroscopic binary systems : Algol, ${\beta}$ Aur, and ${\varepsilon}$ Per. The radial velocity amplitudes of the primary and the secondary (K1 and K2) were consistent within a few % of the values from the previous studies. Mass ratios between the two stars that constitutes each system ranges ~1 to ~10. In addition to the orbital elements derived, we discuss about the spectroscopic ability of the DOAO/eShels instrument.

  • PDF

유아관찰기록척도(K-COR-II) 타당화 연구 (A Study for Validation of the Preschool Child Observation Record (COR) for Korean Children)

  • 신나리;오정순
    • 한국보육지원학회지
    • /
    • 제9권6호
    • /
    • pp.309-337
    • /
    • 2013
  • 본 연구는 루브릭 형태로 개발된 유아 평가 중 타당성과 신뢰성을 검증받은 미국 하이스코프 재단의 유아용 Child Observation Record-II를 국내 유아를 대상으로 사용할 수 있도록 타당화하여 유아관찰기록척도(K-COR-II)로 명명하는데 있다. 이를 위해 서울, 인천, 대전, 경기 및 충북에 소재한 8개 어린이집의 만 3세부터 만 6세 유아 255명과 담임교사 32명을 대상으로 2개월 이상의 관찰 후 K-COR-II를 사용하여 평정을 실시하였고, 공인타당도 확보를 위하여 K-CDI를 함께 실시하였다. 신뢰도와 문항양호도 검중 및 타당도 검증을 위해 상관분석과 탐색적, 확인적 요인분석 및 AVE와 개념신뢰도 지수를 산출하였다. 그 결과 K-COR-II 각 항목의 내용타당도는 높게 나타났으나, 판별타당도 분석 결과 하위영역 간의 차별성은 떨어지는 것으로 밝혀졌다. 확인적 요인분석과 AVE 및 개념신뢰도 지수 산출 검토 결과 집중타당도는 만족스러운 것으로 나타났으며, K-CDI를 이용한 공인타당도 결과 각 영역 간 상관은 통계적으로 유의미한 수준으로 나타났다. 관찰자간 신뢰도와 영역별 항목간 내적합치도 또한 만족스러운 수준으로 판단되어 신뢰도 또한 확보되었으며, 각 문항별로 상 하 집단 간의 유의한 평균 차이가 있는지를 알아본 결과, 문항변별도 또한 만족스러운 것으로 판단되었다. 이에 타당화된 K-COR-II가 유아교육 및 보육현장에서 유아의 발달 수준을 가늠하는데 활용가능한 신뢰롭고 타당한 도구로 판단되었다.

한국인 영아초기 수유시 모아상호작용 행동형태에 관한 현상학적 연구 (A Phenomenological Study on Mother-Infant Interacting Behavior Patterns Related to Newborn Infant Feeding in Korea)

  • 한경자
    • 대한간호학회지
    • /
    • 제21권1호
    • /
    • pp.89-116
    • /
    • 1991
  • The purpose of this study was to describe mother -infant interacting behavior patterns related to newborn infant feeding and to explore the mother's cultural belief about their infant. The data collection was conducted by observation and interview. Twenty-five mothers and their newborn infants who were normally delivered and were also planned to breast feed were comprised as the subjects of this study. All subjects were interviewed and observed individuaily at 1 to 5 days after the delivery at the hospital, mid -wife's clinic, Maternal Child Health Center and their home throughout the country from remote area to big city, The observation data were recorded with symbolic letter on a recording sheet newly developed as a result of preliminary study. The interview data were taperecorded and then recorded in narrative form. Mother - infant interaction behaviors in early feeding period were analyzed based on 19 analytic sub-categories and their composing elements. Unit of analysis were mother, infant and mother -infant dyad. 8 analytic categories draw from the data. Each were preparation, instrument, interaction inducing, evaluation referred to mother's behavior, preparation, instrument, interaction inducing referred to infant's behavior and synchronic behaviors referred to mother - infant dyad. Frequencies of behavior items based on the categories were converted to percent. The result showed that in mother's preparation behavior, the breast condition of Korean mother can be an affecting factor for mother - infant interaction during feeding, and vocalization behavior was observed most frequently in interaction inducing behavior while the least frequent behavior observed was contacting. Subcultural characteristics of mother - infant interaction behaviors were analyzed for their relationships between groups of mothers who have lived in remote area vs urban area, and who were multipara vs primipara. Using a chi -square test, there were statistically significant relationships in the activity of psychological readiness in preparation behavior and the movement of extremities for the position of instrumental behavior in both groups. However, interaction inducing behaviors were not related with statistical significance in any set of groups. Accomplishment of marriage, bonding and emotional mediation of family members were the categories related to mother's cultural belief about the infant in aspect of functional values. Infant at birth is considered little more than a biological organism without social capabilities. Although the newborn infant is still be attached to his mother, he makes his mother extend her territoriality. The mother's interacting behavior toward her infant based on those beliefs appeared task oriented, separative behavioral series. On the other hand, it was seen that infant reacted independently to his mother's behavior by the in-nate perceptual abilities. Those independent behavioral series of mother and infant on the feeding situation were synchronized at any moment. Nurses are In a unique position to teach mothers about their infant's capabilities and help reducing some of uncertainty about infant's behaviors. Study results indicated that the informations infant's social capabilities and breast feeding should be given to the mothers. The results of this study have several implications for nursing. First, the study results will be used as fundamental resources for the development of the assessment tool about the early mother - infant interaction. Second, the results could be a relevant information in the fied. I of maternal child nursing education as real and useful data. Third, the behavioral patterns of early mother - infant interaction which were classified based on the qualitative analysis could be used for nursing theory development as very fundamental data.

  • PDF

노인의 섬망 사정을 위한 도구의 임상적 사용 용이성에 관한 연구 (Comparison of Delirium Screening Instruments for the Elderly)

  • 이영휘;장성옥;공은숙;김남초;김춘길;김희경;송미순;안수연;조명옥;최경숙
    • 성인간호학회지
    • /
    • 제25권6호
    • /
    • pp.655-664
    • /
    • 2013
  • Purpose: This study was undertaken to identify which delirium screening instrument would be more useful in clinical practice. Methods: Data were collected from 118 nurses from six hospitals in five provinces in Korea. For the delirium screening three instruments were compared: NEECHAM Confusion Scale (NEECHAM), Nursing Delirium Screening Scale (Nu-DESC), Delirium Observation Scale (DOS). The MMSE-K was used for concurrent validity. The nurse subjects were surveyed as to the practical clinical value of each instrument. Cronbach's ${\alpha}$ coefficient and Kuder-Richardson 20 were used to confirm the reliability. Results: The range of three scales reliability was .70~.82 and the range of correlation coefficient was .63~.82 with MMSE-K. For sensitivity of NEECHAM, Nu-DESC and DOS was 1.00, 1.00 and 0.81 respectively and specificity NEECHAM, Nu-DESC and DOS was 0.88, 0.89 and 0.89 respectively. Nurses rated the practical use of the DOS scale as significantly easier to use than the NEECHAM and Nu-DESC. Conclusion: NEECHAM, Nu-DESC and DOS scales were acceptable in terms of reliability, validity, sensitivity and specificity. However, nurses rated the DOS scale as easier scale to use and had more relevance to their practice.

Gracey curet과 Ultrasonic scaler 사용 시의 치면 특성의 주사현미경적 연구 (Scanning electron microscopic study on characteristics of tooth surface when using gracey curet and ultrasonic scaler)

  • 남용옥;이화정;최미혜
    • 한국치위생학회지
    • /
    • 제16권4호
    • /
    • pp.635-641
    • /
    • 2016
  • Objectives: The purpose of this study is to assess the characteristics of tooth surface after using Gracy curet and Ultrasonic scaler Methods: In this study, 12 teeth extracted were used. 12 specimens were divided into three groups with the same numbers, which were classified into Control group, Gracy curet use group, and Ultrasonic scaler use group, and after performing instrument operation, we measured the roughness and the loss degree of tooth surface by using SEM. Results: In groups using Gracy curet and Ultrasonic scaler, the roughness and the loss of tooth surface increased significantly(p<0.05). In the roughness of groups using Gracy curet and Ultrasonic scaler, Ultrasonic scaler group was higher in crown, but Gracy curet group was higher in root. As a result of observation through SEM, the roughness and the loss degree increased in order of Control group, Ultrasonic scaler use group, and Gracy curet use group. Conclusions: Taken together above results, both hand instrument and ultrasound equipment create roughness and loss in crown and in root, and hand instruments makes rougher than ultrasonic instruments in root, so it is thought to require thorough and accurate technical application not to damage tooth surface when removing plaque.

KSR-III 과학 관측 로켓 자력계(MAG/AIM & SIM)의 초기 시험 모델 개발 (DESIGN AND PRELIMINARY TEST RESULTS OF MAGNETOMETERS (MAG/AIM & SIM) FOR SOUNDING ROCKET KSR-III)

  • 김효민;장민환;손대락;이동훈;김선미;황승현
    • 천문학논총
    • /
    • 제15권spc2호
    • /
    • pp.57-64
    • /
    • 2000
  • It is realized that the extraterrestrial matter is in ionized state, plasma, so the matter of this kind behaves as not expected because of its sensitiveness to electric and magnetic fields and its ability to carry electric currents. This kind of subtle change can be observed by an instrument for the magnetic field measurement, the magnetometer usually mounted on the rocket and the satellite, and based on the ground observatory. The magnetometer is a useful instrument for the spacecraft attitude control and the Earth's magnetic field measurements for the scientific purpose. In this paper, we present the preliminary design and the test results of the two onboard magnetometers of KARl's (Korea Aerospace Research Institute) sounding rocket, KSR­III, which will be launched during the period of 2001-02. The KSR-III magnetometers consist of the fluxgate magnetometer, MAG/AIM (Attitude Information Magnetometer) for acquiring the rocket flight attitude information, and of the search-coil magnetometer, MAG/SIM (Scientific Investigation Magnetometer) for the observation of the Earth's magnetic field fluctuations. With the MAG/AIM, the 3-axis attitude information can be acquired by the comparison of the resulting dc magnetic vector fields with the IGRF (International Geomagnetic Reference Field). The Earth's magnetic field fluctuations ranging from 10 to 1,000 Hz can also be observed with the MAG/SIM measurement.

  • PDF