• Title/Summary/Keyword: Oblique condition

검색결과 148건 처리시간 0.046초

Influence of Difficulty Variation of the Core Stabilization Exercise on Thickness Changes of Abdominal Muscles in Healthy Subjects: A Pilot Study

  • Kang, Jeong-Hyeon;Suh, Hye-Rim;Kim, Chang-Yong;Kim, Hyeong-Dong;Kim, Hyungkun
    • The Journal of Korean Physical Therapy
    • /
    • 제28권2호
    • /
    • pp.112-118
    • /
    • 2016
  • Purpose: This study examined thickness changes in abdominal muscles according to difficulty level of core stabilization exercise in healthy subjects. Methods: Thirty healthy subjects (age range: 21-30 years) volunteered under three conditions. In the first condition, the subjects performed an abdominal draw-in maneuver (ADIM). In the second condition, they performed the ADIM during quadruped exercise using a suspension device without extending their lower limbs. In the third condition, the subjects performed the ADIM during quadruped exercise using a suspension device while extending both lower limbs. The changes in thickness of transverse abdominis (TrA), internal oblique (IO), and external oblique (EO) muscles were measured by ultrasonography (US) imaging during the three experimental conditions, and US was used to measure the improvement ratio of muscle thickness at rest. The interventions were conducted over three trials in each condition, and measurements were performed on each subject by one examiner. Results: Our results showed a significantly greater increase in the muscle thickness of TrA and IO muscles after performance of quadruped exercise using a suspension device without knee extension (p<0.05) compared to the other conditions. The results also showed a significantly greater increase in the thickness changes of EO muscle in those who performed the ADIM during quadruped exercise using a suspension device with knee extension (p<0.05) compared with the ADIM only. Conclusion: These findings demonstrated positive evidence that a low-level core stabilization exercise could improve thickness of abdominal muscles.

An Experimental Study on Hydrodynamic Forces of Korea Autonomous Surface Ship in Various Loading Conditions

  • Nguyen, Thi Thanh Diep;Mai, Van Thuan;Lee, San;Yoon, Hyeon Kyu
    • Journal of Navigation and Port Research
    • /
    • 제46권2호
    • /
    • pp.73-81
    • /
    • 2022
  • Currently, shipping by sea is becoming common because of the low price and the safety of goods. The ship is designed as a larger vessel to meet the need of this development. In the design stage, the investigation of hydrodynamic forces acting on the ship hull is very important in predicting the ship's maneuverability. Given that the ship docks at various ports for loading or discharging goods, the ship usually operates in various loading conditions, depending on the site condition and other various factors. Hence, it is necessary to investigate the effect of the loading condition on the hydrodynamic forces acting on the ship, to most accurately determine the maneuverability of the ship. In this study, an experiment of Korea Autonomous Surface Ship (KASS) was conducted at the towing tank of Changwon National University to measure the hydrodynamic forces acting on the KASS. The loading condition considered in this experiment is determined based on the draft, which was decreased by 5% for each loading condition. The smallest draft is 85% of the design draft. The static test as Oblique Towing Test (OTT), Circular Motion Test (CMT), Circular Motion Test with Drift (CMTD) is performed in the various loading conditions. First, the hydrodynamic forces in the Oblique Towing test (OTT) are compared with the result of other institutes. Second, the hydrodynamic forces in various drift angle, yaw rate and loading conditions are measured. Finally, the influence of the loading conditions on the hydrodynamic coefficient is discussed.

STRESS ANALYSIS OF SUPPORTING TISSUES ACCORDING TO IMPLANT FIXTURE DIAMETER AND RESIDUAL ALVEOLAR BONE WIDTH (치조골 폭경과 임플랜트 고정체의 직경에 따른 지지조직의 응력분포)

  • Han, Sang-Un;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제45권4호
    • /
    • pp.506-521
    • /
    • 2007
  • Statement of problem: The cumulative success rate of wide implant is still controversial. Some previous reports have shown high success rate, and some other reports shown high failure rate. Purpose: The aim of this study was to analyze, and compare the biomechanics in wide implant system embeded in different width of crestal bone under different occlusal forces by finite element approach. Material and methods: Three-dimensional finite element models were created based on tracing of CT image of second premolar section of mandible with one implant embedded. One standard model (6mm-crestal bone width, 4.0mm implant diameter central position) was created. Varied crestal dimension(4, 6, 8 mm), different diameter of implants(3.3, 4.0, 5.5, 6.0mm), and buccal position implant models were generated. A 100-N vertical(L1) and 30 degree oblique load from lingual(L2) and buccal(L3) direction were applied to the occlusal surface of the crown. The analysis was performed for each load by means of the ANSYS V.9.0 program. Conclusion: 1. In all cases, maximum equivalent stress that applied $30^{\circ}$ oblique load around the alveolar bone crest was larger than that of the vertical load. Especially the equivalent stress that loaded obliquely in buccal side was larger. 2. In study of implant fixture diameter, stress around alveolar bone was decreased with the increase of implant diameter. In the vertical load, as the diameter of implant increased the equivalent stress decreased, but equivalent stress increased in case of the wide implant that have a little cortical bone in the buccal side. In the lateral oblique loading condition, the diameter of implant increased the equivalent stress decreased, but in the buccal oblique load, there was not significant difference between the 5.5mm and 6.0mm as the wide diameter implant. 3. In study of alveolar bone width, equivalent stress was decreased with the increase of alveolar bone width. In the vertical and oblique loading condition, the width of alveolar bone increased 6.0mm the equivalent stress decreased. But in the oblique loading condition, there was not a difference equivalent stress at more than 6.0mm of alveolar bone width. 4. In study of insertion position of implant fixture, even though the insertion position of implant fixture move there was not a difference equivalent stress, but in the case of little cortical bone in the buccal side, value of the equivalent stress was most unfavorable. 5. In all cases, it showed high stress around the top of fixture that contact cortical bone, but there was not a portion on the bottom of fixture that concentrate highly stress and play the role of stress dispersion. These results demonstrated that obtaining the more contact from the bucco-lingual cortical bone by installing wide diameter implant plays an important role in biomechanics.

Numerical Simulation of Convection-dominated Flow Using SU/PG Scheme (SU/PG 기법을 이용한 이송이 지배적인 흐름 수치모의)

  • Song, Chang Geun;Seo, Il Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • 제32권3B호
    • /
    • pp.175-183
    • /
    • 2012
  • In this study, Galerkin scheme and SU/PG scheme of Petrov-Galerkin family were applied to the shallow water equations and a finite element model for shallow water flow was developed. Numerical simulations were conducted in several flumes with convection-dominated flow condition. Flow simulation of channel with slender structure in the water course revealed that Galerkin and SU/PG schemes showed similar results under very low Fr number and Re number condition. However, when the Fr number increased up to 1.58, Galerkin scheme did not converge while SU/PG scheme produced stable solutions after 5 iterations by Newton-Raphson method. For the transcritical flow simulation in diverging channel, the present model predicted the hydraulic jump accurately in terms of the jump location, the depth slope, and the flow depth after jump, and the numerical results showed good agreements with the hydraulic experiments carried out by Khalifa(1980). In the oblique hydraulic jump simulation, in which convection-dominated supercritical flow (Fr=2.74) evolves, Galerkin scheme blew up just after the first iteration of the initial time step. However, SU/PG scheme captured the boundary of oblique hydraulic jump accurately without numerical oscillation. The maximum errors quantified with exact solutions were less than 0.2% in water depth and velocity calculations, and thereby SU/PG scheme predicted the oblique hydraulic jump phenomena more accurately compared with the previous studies (Levin et al., 2006; Ricchiuto et al., 2007).

ACCURACY IMPROVEMENT OF THE BLEED BOUNDARY CONDITION WITH THE EFFECTS OF POROSITY VARIATIONS AND EXPANSION WAVES (다공도 및 팽창파의 영향을 고려한 BLEED 경계조건 수치 모델링의 정확도 향상 연구)

  • Kim, G.;Choe, Y.;Kim, C.
    • Journal of computational fluids engineering
    • /
    • 제21권1호
    • /
    • pp.94-102
    • /
    • 2016
  • The present paper deals with accuracy improvement of a bleed boundary condition model used to improve the performance of supersonic inlets. In order to accurately predict the amount of bleed mass flow rates, this study performs a scaling of sonic flow coefficient data for 90-degree bleed holes in consideration of Prandtl-Meyer expansion theory. Furthermore, it is assumed that porosity varies with stream-wise location of the porous bleed plate to accurately predict downstream boundary layer profiles. The bleed boundary condition model is demonstrated through Computational Fluid Dynamics(CFD) simulations of bleed flows on a flat plate with/without an oblique shock. As a result, the bleed model shows the improved accuracy of bleed mass rates and downstream boundary layer profiles.

A Clinical Experience of Total Scalp Avulsion in a Male (남성에서 두피 전층 결출 손상의 치험례)

  • Song, JenniferKim;Kim, Min-Wook;Hwang, So-Min;Lim, Kwang-Ryeol;Jung, Yong-Hui;Ahn, Sung-Min
    • Archives of Reconstructive Microsurgery
    • /
    • 제20권1호
    • /
    • pp.74-77
    • /
    • 2011
  • Total scalp avulsion is rare but a devastating injury. This condition burdens the patient with disfigured cosmetic appearance and permanent psychosocial trauma. Throughout history, this condition has been favored in women working with mechanics since the long hair function as a vector appliance for oblique pull of the hair into a stationary torque. We present our experience of the replantation of the total avulsed scalp in male, first to be reported in Korea. Warm ischemic time was exceeding 16 hours along with severe crushed condition of the detached margin, a relatively satisfactory result was obtained.

  • PDF

A Numerical Study on Flow and Heat Transfer Characteristics for an Oblique Impingement Jet Using $k-{\varepsilon}-\bar{\upsilon{'}^2}$ Model ($k-{\varepsilon}-\bar{\upsilon{'}^2}$모델을 이용한 경사진 충돌제트의 유동 및 열전달 특성에 대한 수치해석적 연구)

  • Choe, Yeong-Gi;Choe, Bong-Jun;Lee, Jeong-Hui
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제25권9호
    • /
    • pp.1183-1192
    • /
    • 2001
  • The numerical simulation has been conducted for the investigation of flow and heat transfer characteristics of an oblique impingement jet injected to a flat plate. The finite volume method was used to discretize the governing equations based on the non-orthogonal coordinate with non-staggered variable arrangement. The $textsc{k}$-$\varepsilon$-ν(sup)'2 turbulence model was employed to consider the consider the anisotropic flow characteristics generated by the impingement jet flow. The predicted results were compared with the experimental data and those of the standard $textsc{k}$-$\varepsilon$ turbulence model. The results of the $textsc{k}$-$\varepsilon$-ν(sup)'2 model showed better agreement with the experimental data than those of the standard $textsc{k}$-$\varepsilon$ model. In order to get the optimum condition, the flow and temperature fields were calculated with a variation of inclined angle($\alpha$=30$^{\circ}$~90$^{\circ}$) and the distance between the jet exit and impingement plate-to-diameter (L/D=4~10) at a fixed Reynolds number(Re=20,000). For a small L/D, the near-peak Nusselt numbers were not significantly effected by the inclined angle. The near-peak Nusselt numbers were not significantly affected by the L/D in the case of a large $\alpha$. The overall shape of the local Nusselt numbers was influenced by both the jet orifice-to-plate spacing and the jet angle.

Finite Element Analysis of Stress Distribution on Supporting Bone of Cement Retained Implant by Oblique Loading (경사하중에 따른 시멘트 유지형 임플란트 지지골의 유한요소법 응력 분포)

  • Lee, Myung-Kon
    • The Journal of the Korea Contents Association
    • /
    • 제14권9호
    • /
    • pp.343-349
    • /
    • 2014
  • The dental osseointegration implant should be enough to endure occlusion load and it's required to have efficient design and use of implant to disperse the stress into bones properly. Solidworks as a finite element analysis program for modeling and analysis of stress distribution was used for the research. The simple crown model was designed on applying conjoined condition with tightening torque of 20 Ncm of a abutment screw between a cement retained implant abutment and a fixture. A $45^{\circ}$ oblique loading from lingual to buccal side on buccal cusps of crown and performed finite element analysis by 100 N of external load. The results by a analysis for stress distribution of supporting bones of fixture were as below. The von Mises stress was concentrated on the upper side of supporting compact bone regardless of the diameters and lengths of fixture, and the efficiency result of stress reduction was increase of fixture's diameter than it's length. Therefore, it's effective to use wider fixture as possible to the conditions of supporting jaw bone.

Properties of TiN Films Fabricated by Oblique Angle Deposition (빗각 증착으로 제조된 TiN 박막의 특성)

  • Jung, Jae-Hun;Yang, Ji-Hoon;Park, Hye-Sun;Song, Min-A;Jeong, Jae-In
    • Journal of the Korean institute of surface engineering
    • /
    • 제45권3호
    • /
    • pp.106-110
    • /
    • 2012
  • Oblique angle deposition (OAD) is a physical vapor deposition where incident vapor flux arrives at non-normal angles. It has been known that tilting the substrate changes the properties of the film, which is thought to be a result of morphological change of the film. In this study, OAD has been applied to prepare single and multilayer TiN films by cathodic arc deposition. TiN films have been deposited on cold-rolled steel sheets and stainless steel sheet. The deposition angle as well as substrate temperature and substrate bias was changed to investigate their effects on the properties of TiN films. TiN films were analyzed by color difference meter, scanning electron microscopy, nanoindenter and x-ray diffraction. The color of TiN films was not much changed according to the deposition conditions. The slanted and zigzag structures were observed from the single and multilayer films. The relation between substrate tilting angle (${\alpha}$) and the growth column angle (${\beta}$) followed the equation of $tan{\alpha}=2tan{\beta}$. The indentation hardness of TiN films deposited by OAD was low compared with the ones prepared at normal angle. However, it has been found that $H^3/E^2$ ratio of 3-layer TiN films prepared at OAD condition was a little higher than the ones prepared at normal angle, which can confirm the robustness of prepared films.

A Study on the Stress Distribution of Condylar Region and Edentulous Mandible with Implant-Supported Cantilever Fixed Prostheses by using 3-Dimensional Finite Element Method (임플란트 지지 캔틸레버 고정성 보철물 장착시 과두와 하악골의 응력 분포에 관한 3차원 유한요소법적 연구)

  • Kim, Yeon-Soo;Lee, Sung-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • 제17권4호
    • /
    • pp.283-305
    • /
    • 2001
  • The purpose of this study was to analyze the stress distribution of condylar regions and edentulous mandible with implant-supported cantilever prostheses on the certain conditions, such as amount of load, location of load, direction of load, fixation or non-fixation on the condylar regions. Three dimensional finite element analysis was used for this study. FEM model was created by using commercial software, ANSYS(Swanson, Inc., U.S.A.). Fixed model which was fixed on the condylar regions was modeled with 74323 elements and 15387 nodes and spring model which was sprung on the condylar regions was modeled with 75020 elements and 15887 nodes. Six Br${\aa}$nemark implants with 3.75 mm diameter and 13 mm length were incorporated in the models. The placement was 4.4 mm from the midline for the first implant; the other two in each quardrant were 6.5 mm apart. The stress distribution on each model through the designed mandible was evaluated under 500N vertical load, 250N horizontal load linguobuccally, buccal 20 degree 250N oblique load and buccal 45 degree 250N oblique load. The load points were at 0 mm, 10 mm, 20 mm along the cantilever prostheses from the center of the distal fixture. The results were as follows; 1. The stress distribution of condylar regions between two models showed conspicuous differences. Fixed model showed conspicuous stress concentration on the condylar regions than spring model under vertical load only. On the other hand, spring model showed conspicuous stress concentration on the condylar regions than fixed model under 250N horizontal load linguobuccally, buccal 20 degree 250N oblique load and buccal 45 degree 250N oblique load. 2. Fixed model showed stress concentration on the posterior and mesial side of working and balancing condylar necks but spring model showed stress concentration on the posterior and mesial side of working condylar neck and the posterior and lateral side of balancing condylar neck under vertical load. 3. Fixed model showed stress concentration on the posterior and lateral side of working condylar neck and the anterior and mesial side of balancing condylar neck but spring model showed stress concentration on the anterior sides of working and balancing condylar necks under horizontal load linguobuccally. 4. Fixed model showed stress concentration on the posterior side of working condylar neck and the posterior and lateral side of balancing condylar neck but spring model showed stress concentration on the anterior side of working condylar neck and the anterior and lateral side of balancing condylar neck under buccal 20 degree oblique load. 5. Fixed model showed stress concentration on the anterior and lateral side of working condylar neck and the posterior and mesial side of balancing condylar neck but spring model showed stress concentration on the anterior side of working condylar neck and the anterior and lateral side of balancing condylar neck under buccal 45 degree oblique load.. 6. The stress distribution of bone around implants between two models revealed difference slightly. In general, magnitude of Von Mises stress was the greatest at the bone around the most distal implant and the progressive decrease more and more mesially. Under vertical load, the stress values were similar between implant neck and superstructure vertically, besides the greatest on the distal side horizontally. 7. Under horizontal load linguobuccally, buccal 20 degree oblique load and buccal 45 degree oblique load, the stress values were the greatest on the implant neck vertically, and great on the labial and lingual sides horizontally. After all, it was considered that spring model was an indispensable condition for the comprehension of the stress distributions of condylar regions.

  • PDF